{"title":"Goodman, 3 Ton Systems, 15.0 SEER2","description":null,"products":[{"product_id":"goodman-gzv7sa3610-capea4830c3-217577966","title":"Goodman | 3 Ton | 15.0 SEER2 | R-32 | Heat Pump Condenser and Evaporator Coil System | GZV7SA3610 | CAPEA4830C3 | 21\" Cabinet Width | Upflow\/Downflow | Coil","description":"\u003cp\u003eThis Goodman Heat Pump Condenser and Evaporator Coil System pairs the GZV7SA3610 3-Ton R-32 variable-speed heat pump condenser with the CAPEA4830C3 cased evaporator coil. Rated at 15.0 SEER2, 8.0 HSPF2, and 10.0 EER2, this AHRI-certified combination (Certificate #217577966) provides efficient all-electric heating and cooling. This system uses R-32 refrigerant (GWP 675), a lower-GWP alternative that supports the EPA’s AIM Act phase-down schedule. It qualifies for ENERGY STAR® Cold Climate certification and may be eligible for federal tax credits under the Inflation Reduction Act (IRA) — consult a qualified tax professional for details.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the ‘Resources (System Manuals and Warranty)’ Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGZV7SA3610 — Goodman 3-Ton, Variable-Speed, Inverter-Driven, Side-Discharge R-32 Heat Pump Condenser (208-230V\/1Ph\/60Hz)\u003c\/li\u003e\n\u003cli\u003eCAPEA4830C3 — Goodman Cased Upflow\/Downflow Evaporator Coil with EEV (21\" W × 21\" D × 30\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background-color:#f7f7f7;border-left:4px solid #d35400;padding:15px;margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Coil-Only Heat Pump Configuration\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e A standalone coil paired directly with the GZV7SA3610 heat pump condenser requires a separate air-moving device (existing furnace blower, fan coil, or AHU) that is not included in this matchup. The coil must be properly oriented — CAPEA models in upflow\/downflow position, CHPEA models in horizontal position — and the existing air mover must deliver adequate CFM (approximately 1,200 CFM for 3 tons) against the coil’s pressure drop. Verify the existing blower’s motor can handle the added static.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After connecting the coil, run the system and measure total external static pressure. If the existing blower is a standard PSC motor, it may not compensate for the coil’s resistance, resulting in reduced airflow and poor dehumidification within the first cooling season. Documenting the airflow and static at startup provides a baseline for future service calls.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Verify refrigerant charge using the GZV7S subcooling method (target 9±1°F for the 3-ton unit with ⅜” liquid line). Use a calibrated digital manifold with R-32 profiles. Confirm the EEV in the coil is receiving proper control signal from the outdoor unit’s inverter board via the communicating connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e Even in coil-only configurations, R-32 charge limits per ASHRAE 15 apply. The indoor coil does not include a refrigerant sensor — confirm whether your local jurisdiction requires one based on the total system charge and the smallest room volume served. Document EPA Section 608 certification and system charge weight on the installation permit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Rated Performance:\u003c\/strong\u003e This AHRI-certified system achieves 15.0 SEER2 and 8.0 HSPF2, delivering measurable energy savings compared to minimum-efficiency (14.3 SEER2) systems. The variable-speed inverter compressor in the GZV7SA3610 modulates capacity to match the actual load, reducing short-cycling and improving humidity control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2,088). This supports compliance with EPA AIM Act phase-down requirements and positions this system for long-term refrigerant availability. R-32 also has higher volumetric cooling capacity, meaning smaller charge quantities for equivalent performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR® Cold Climate Certified:\u003c\/strong\u003e This combination meets the stringent ENERGY STAR Cold Climate criteria, verifying effective heating performance at outdoor temperatures down to 5°F. The GZV7SA3610 delivers 22,000 BTU\/h at 5°F, maintaining heat pump operation well below typical balance points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation with Sound Control:\u003c\/strong\u003e The GZV7SA3610 features a high-density compressor sound blanket, quiet digitally commutated fan motor, and field-selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA). The side-discharge cabinet design with grille-style sound control further reduces perceived noise at the property line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Intelligence \u0026amp; Communicating Control:\u003c\/strong\u003e The system includes a 7-segment LED display with fault code storage, proprietary Inside Intelligence for diagnostics, and full communicating capability requiring only two low-voltage wires between indoor and outdoor units. Compatible with the Goodman GTST connected thermostat for enhanced monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;max-width:700px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#333;color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217577966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eHeat Pump Condenser and Evaporator Coil System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton (36,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e34,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 47°F\u003c\/td\u003e\n\u003ctd\u003e34,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd\u003e22,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit: GZV7SA3610\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e37” × 12⅝” × 39”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \/ Phase\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge (Factory)\u003c\/td\u003e\n\u003ctd\u003e100 oz (⅜” liquid line, 15 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil: CAPEA4830C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e21\" × 21\" × 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e68 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ ⅞\" or 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See ‘Resources (System Manuals and Warranty)’ Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;max-width:700px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — 68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirement\u003c\/td\u003e\n\u003ctd\u003eTechnician certification required for handling R-32. Recovery equipment must be A2L-rated.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions (DOE 2023 minimum efficiency standards met). Verify local A2L adoption status with your AHJ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR® Status\u003c\/td\u003e\n\u003ctd\u003eCold Climate Certified; Most Efficient 2025 (when matched per ENERGY STAR system requirements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility (IRA)\u003c\/td\u003e\n\u003ctd\u003eMay qualify for federal energy efficiency tax credits under 25C. Consult IRS guidance and a qualified tax professional for current eligibility and caps.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (applies to A2L refrigerant systems); ETL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eCertificate #217577966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA3610 Heat Pump Condenser:\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when registered online within 60 days of installation at www.goodmanmfg.com. If the compressor fails within the first 10 years, Goodman will furnish a new equivalent outdoor unit (one-time replacement). Without registration, warranty coverage is limited to 5 years on all parts. One-time Compressor Replacement coverage is available for years 11–99 through an ASURE Extend Service Plan (available from ASURE dealers). Online registration is not required in California, Florida, or Québec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA4830C3 Evaporator Coil:\u003c\/strong\u003e 10-Year Parts Limited Warranty when registered online within 60 days of installation at www.goodmanmfg.com. Without registration, warranty coverage is limited to 5 years on all parts. Registration is not required in California, Florida, or Québec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties provided by Daikin Comfort Technologies Manufacturing, Inc. Warranty applies to heating and air conditioning units installed in owner-occupied residences. Labor, refrigerant, freight, and associated installation costs are not covered. Refer to full warranty documents for complete terms, conditions, and exclusions.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658771169600,"sku":"GZV7SA3610-CAPEA4830C3-217577966","price":4918.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/uhjhluulled.jpg?v=1777747334"},{"product_id":"goodman-gzv7sa3610-capea4830d3-217577966","title":"Goodman | 3 Ton | 15.0 SEER2 | R-32 | Heat Pump Condenser and Evaporator Coil System | GZV7SA3610 | CAPEA4830D3 | 24½\" Cabinet Width | Upflow\/Downflow | Coil","description":"\u003cp\u003eThis Goodman Heat Pump Condenser and Evaporator Coil System pairs the GZV7SA3610 3-Ton R-32 variable-speed heat pump condenser with the CAPEA4830D3 cased evaporator coil. Rated at 15.0 SEER2, 8.0 HSPF2, and 10.0 EER2, this AHRI-certified combination (Certificate #217577966) provides efficient all-electric heating and cooling. This system uses R-32 refrigerant (GWP 675), a lower-GWP alternative that supports the EPA’s AIM Act phase-down schedule. It qualifies for ENERGY STAR® Cold Climate certification and may be eligible for federal tax credits under the Inflation Reduction Act (IRA) — consult a qualified tax professional for details.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the ‘Resources (System Manuals and Warranty)’ Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGZV7SA3610 — Goodman 3-Ton, Variable-Speed, Inverter-Driven, Side-Discharge R-32 Heat Pump Condenser (208-230V\/1Ph\/60Hz)\u003c\/li\u003e\n\u003cli\u003eCAPEA4830D3 — Goodman Cased Upflow\/Downflow Evaporator Coil with EEV (24½\" W × 21\" D × 30\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background-color:#f7f7f7;border-left:4px solid #d35400;padding:15px;margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Coil-Only Heat Pump Configuration\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e A standalone coil paired directly with the GZV7SA3610 heat pump condenser requires a separate air-moving device (existing furnace blower, fan coil, or AHU) that is not included in this matchup. The coil must be properly oriented — CAPEA models in upflow\/downflow position, CHPEA models in horizontal position — and the existing air mover must deliver adequate CFM (approximately 1,200 CFM for 3 tons) against the coil’s pressure drop. Verify the existing blower’s motor can handle the added static.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After connecting the coil, run the system and measure total external static pressure. If the existing blower is a standard PSC motor, it may not compensate for the coil’s resistance, resulting in reduced airflow and poor dehumidification within the first cooling season. Documenting the airflow and static at startup provides a baseline for future service calls.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Verify refrigerant charge using the GZV7S subcooling method (target 9±1°F for the 3-ton unit with ⅜” liquid line). Use a calibrated digital manifold with R-32 profiles. Confirm the EEV in the coil is receiving proper control signal from the outdoor unit’s inverter board via the communicating connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e Even in coil-only configurations, R-32 charge limits per ASHRAE 15 apply. The indoor coil does not include a refrigerant sensor — confirm whether your local jurisdiction requires one based on the total system charge and the smallest room volume served. Document EPA Section 608 certification and system charge weight on the installation permit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Rated Performance:\u003c\/strong\u003e This AHRI-certified system achieves 15.0 SEER2 and 8.0 HSPF2, delivering measurable energy savings compared to minimum-efficiency (14.3 SEER2) systems. The variable-speed inverter compressor in the GZV7SA3610 modulates capacity to match the actual load, reducing short-cycling and improving humidity control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2,088). This supports compliance with EPA AIM Act phase-down requirements and positions this system for long-term refrigerant availability. R-32 also has higher volumetric cooling capacity, meaning smaller charge quantities for equivalent performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR® Cold Climate Certified:\u003c\/strong\u003e This combination meets the stringent ENERGY STAR Cold Climate criteria, verifying effective heating performance at outdoor temperatures down to 5°F. The GZV7SA3610 delivers 22,000 BTU\/h at 5°F, maintaining heat pump operation well below typical balance points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation with Sound Control:\u003c\/strong\u003e The GZV7SA3610 features a high-density compressor sound blanket, quiet digitally commutated fan motor, and field-selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA). The side-discharge cabinet design with grille-style sound control further reduces perceived noise at the property line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Intelligence \u0026amp; Communicating Control:\u003c\/strong\u003e The system includes a 7-segment LED display with fault code storage, proprietary Inside Intelligence for diagnostics, and full communicating capability requiring only two low-voltage wires between indoor and outdoor units. Compatible with the Goodman GTST connected thermostat for enhanced monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;max-width:700px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#333;color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217577966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eHeat Pump Condenser and Evaporator Coil System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton (36,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e34,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 47°F\u003c\/td\u003e\n\u003ctd\u003e34,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd\u003e22,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit: GZV7SA3610\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e37” × 12⅝” × 39”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \/ Phase\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge (Factory)\u003c\/td\u003e\n\u003ctd\u003e100 oz (⅜” liquid line, 15 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil: CAPEA4830D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e24½\" × 21\" × 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e70 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ ⅞\" or 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See ‘Resources (System Manuals and Warranty)’ Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;max-width:700px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — 68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirement\u003c\/td\u003e\n\u003ctd\u003eTechnician certification required for handling R-32. Recovery equipment must be A2L-rated.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions (DOE 2023 minimum efficiency standards met). Verify local A2L adoption status with your AHJ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR® Status\u003c\/td\u003e\n\u003ctd\u003eCold Climate Certified; Most Efficient 2025 (when matched per ENERGY STAR system requirements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility (IRA)\u003c\/td\u003e\n\u003ctd\u003eMay qualify for federal energy efficiency tax credits under 25C. Consult IRS guidance and a qualified tax professional for current eligibility and caps.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (applies to A2L refrigerant systems); ETL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eCertificate #217577966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA3610 Heat Pump Condenser:\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when registered online within 60 days of installation at www.goodmanmfg.com. If the compressor fails within the first 10 years, Goodman will furnish a new equivalent outdoor unit (one-time replacement). Without registration, warranty coverage is limited to 5 years on all parts. One-time Compressor Replacement coverage is available for years 11–99 through an ASURE Extend Service Plan (available from ASURE dealers). Online registration is not required in California, Florida, or Québec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA4830D3 Evaporator Coil:\u003c\/strong\u003e 10-Year Parts Limited Warranty when registered online within 60 days of installation at www.goodmanmfg.com. Without registration, warranty coverage is limited to 5 years on all parts. Registration is not required in California, Florida, or Québec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties provided by Daikin Comfort Technologies Manufacturing, Inc. Warranty applies to heating and air conditioning units installed in owner-occupied residences. Labor, refrigerant, freight, and associated installation costs are not covered. Refer to full warranty documents for complete terms, conditions, and exclusions.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658771202368,"sku":"GZV7SA3610-CAPEA4830D3-217577966","price":4932.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/uhjhluulled.jpg?v=1777747334"},{"product_id":"goodman-gzv7sa3610-capea6030c3-217577967","title":"Goodman | 3 Ton | 15.0 SEER2 | R-32 | Heat Pump Condenser and Evaporator Coil System | GZV7SA3610 | CAPEA6030C3 | 21\" Cabinet Width | Upflow\/Downflow | Coil","description":"\u003cp\u003eThis Goodman Heat Pump Condenser and Evaporator Coil System pairs the GZV7SA3610 3-Ton R-32 variable-speed heat pump condenser with the CAPEA6030C3 cased evaporator coil. Rated at 15.0 SEER2, 8.0 HSPF2, and 10.0 EER2, this AHRI-certified combination (Certificate #217577967) provides efficient all-electric heating and cooling. This system uses R-32 refrigerant (GWP 675), a lower-GWP alternative that supports the EPA’s AIM Act phase-down schedule. It qualifies for ENERGY STAR® Cold Climate certification and may be eligible for federal tax credits under the Inflation Reduction Act (IRA) — consult a qualified tax professional for details.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the ‘Resources (System Manuals and Warranty)’ Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGZV7SA3610 — Goodman 3-Ton, Variable-Speed, Inverter-Driven, Side-Discharge R-32 Heat Pump Condenser (208-230V\/1Ph\/60Hz)\u003c\/li\u003e\n\u003cli\u003eCAPEA6030C3 — Goodman Cased Upflow\/Downflow Evaporator Coil with EEV (21\" W × 21\" D × 30\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background-color:#f7f7f7;border-left:4px solid #d35400;padding:15px;margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Coil-Only Heat Pump Configuration\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e A standalone coil paired directly with the GZV7SA3610 heat pump condenser requires a separate air-moving device (existing furnace blower, fan coil, or AHU) that is not included in this matchup. The coil must be properly oriented — CAPEA models in upflow\/downflow position, CHPEA models in horizontal position — and the existing air mover must deliver adequate CFM (approximately 1,200 CFM for 3 tons) against the coil’s pressure drop. Verify the existing blower’s motor can handle the added static.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After connecting the coil, run the system and measure total external static pressure. If the existing blower is a standard PSC motor, it may not compensate for the coil’s resistance, resulting in reduced airflow and poor dehumidification within the first cooling season. Documenting the airflow and static at startup provides a baseline for future service calls.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Verify refrigerant charge using the GZV7S subcooling method (target 9±1°F for the 3-ton unit with ⅜” liquid line). Use a calibrated digital manifold with R-32 profiles. Confirm the EEV in the coil is receiving proper control signal from the outdoor unit’s inverter board via the communicating connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e Even in coil-only configurations, R-32 charge limits per ASHRAE 15 apply. The indoor coil does not include a refrigerant sensor — confirm whether your local jurisdiction requires one based on the total system charge and the smallest room volume served. Document EPA Section 608 certification and system charge weight on the installation permit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Rated Performance:\u003c\/strong\u003e This AHRI-certified system achieves 15.0 SEER2 and 8.0 HSPF2, delivering measurable energy savings compared to minimum-efficiency (14.3 SEER2) systems. The variable-speed inverter compressor in the GZV7SA3610 modulates capacity to match the actual load, reducing short-cycling and improving humidity control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2,088). This supports compliance with EPA AIM Act phase-down requirements and positions this system for long-term refrigerant availability. R-32 also has higher volumetric cooling capacity, meaning smaller charge quantities for equivalent performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR® Cold Climate Certified:\u003c\/strong\u003e This combination meets the stringent ENERGY STAR Cold Climate criteria, verifying effective heating performance at outdoor temperatures down to 5°F. The GZV7SA3610 delivers 22,000 BTU\/h at 5°F, maintaining heat pump operation well below typical balance points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation with Sound Control:\u003c\/strong\u003e The GZV7SA3610 features a high-density compressor sound blanket, quiet digitally commutated fan motor, and field-selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA). The side-discharge cabinet design with grille-style sound control further reduces perceived noise at the property line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Intelligence \u0026amp; Communicating Control:\u003c\/strong\u003e The system includes a 7-segment LED display with fault code storage, proprietary Inside Intelligence for diagnostics, and full communicating capability requiring only two low-voltage wires between indoor and outdoor units. Compatible with the Goodman GTST connected thermostat for enhanced monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;max-width:700px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#333;color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217577967\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eHeat Pump Condenser and Evaporator Coil System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton (36,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e34,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 47°F\u003c\/td\u003e\n\u003ctd\u003e34,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd\u003e22,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit: GZV7SA3610\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e37” × 12⅝” × 39”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \/ Phase\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge (Factory)\u003c\/td\u003e\n\u003ctd\u003e100 oz (⅜” liquid line, 15 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil: CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e21\" × 21\" × 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ ⅞\" or 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See ‘Resources (System Manuals and Warranty)’ Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;max-width:700px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — 68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirement\u003c\/td\u003e\n\u003ctd\u003eTechnician certification required for handling R-32. Recovery equipment must be A2L-rated.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions (DOE 2023 minimum efficiency standards met). Verify local A2L adoption status with your AHJ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR® Status\u003c\/td\u003e\n\u003ctd\u003eCold Climate Certified; Most Efficient 2025 (when matched per ENERGY STAR system requirements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility (IRA)\u003c\/td\u003e\n\u003ctd\u003eMay qualify for federal energy efficiency tax credits under 25C. Consult IRS guidance and a qualified tax professional for current eligibility and caps.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (applies to A2L refrigerant systems); ETL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eCertificate #217577967\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA3610 Heat Pump Condenser:\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when registered online within 60 days of installation at www.goodmanmfg.com. If the compressor fails within the first 10 years, Goodman will furnish a new equivalent outdoor unit (one-time replacement). Without registration, warranty coverage is limited to 5 years on all parts. One-time Compressor Replacement coverage is available for years 11–99 through an ASURE Extend Service Plan (available from ASURE dealers). Online registration is not required in California, Florida, or Québec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3 Evaporator Coil:\u003c\/strong\u003e 10-Year Parts Limited Warranty when registered online within 60 days of installation at www.goodmanmfg.com. Without registration, warranty coverage is limited to 5 years on all parts. Registration is not required in California, Florida, or Québec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties provided by Daikin Comfort Technologies Manufacturing, Inc. Warranty applies to heating and air conditioning units installed in owner-occupied residences. Labor, refrigerant, freight, and associated installation costs are not covered. Refer to full warranty documents for complete terms, conditions, and exclusions.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658771235136,"sku":"GZV7SA3610-CAPEA6030C3-217577967","price":4951.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/uhjhluulled.jpg?v=1777747334"},{"product_id":"goodman-gzv7sa3610-capea6030d3-217577967","title":"Goodman | 3 Ton | 15.0 SEER2 | R-32 | Heat Pump Condenser and Evaporator Coil System | GZV7SA3610 | CAPEA6030D3 | 24½\" Cabinet Width | Upflow\/Downflow | Coil","description":"\u003cp\u003eThis Goodman Heat Pump Condenser and Evaporator Coil System pairs the GZV7SA3610 3-Ton R-32 variable-speed heat pump condenser with the CAPEA6030D3 cased evaporator coil. Rated at 15.0 SEER2, 8.0 HSPF2, and 10.0 EER2, this AHRI-certified combination (Certificate #217577967) provides efficient all-electric heating and cooling. This system uses R-32 refrigerant (GWP 675), a lower-GWP alternative that supports the EPA’s AIM Act phase-down schedule. It qualifies for ENERGY STAR® Cold Climate certification and may be eligible for federal tax credits under the Inflation Reduction Act (IRA) — consult a qualified tax professional for details.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the ‘Resources (System Manuals and Warranty)’ Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGZV7SA3610 — Goodman 3-Ton, Variable-Speed, Inverter-Driven, Side-Discharge R-32 Heat Pump Condenser (208-230V\/1Ph\/60Hz)\u003c\/li\u003e\n\u003cli\u003eCAPEA6030D3 — Goodman Cased Upflow\/Downflow Evaporator Coil with EEV (24½\" W × 21\" D × 30\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background-color:#f7f7f7;border-left:4px solid #d35400;padding:15px;margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Coil-Only Heat Pump Configuration\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e A standalone coil paired directly with the GZV7SA3610 heat pump condenser requires a separate air-moving device (existing furnace blower, fan coil, or AHU) that is not included in this matchup. The coil must be properly oriented — CAPEA models in upflow\/downflow position, CHPEA models in horizontal position — and the existing air mover must deliver adequate CFM (approximately 1,200 CFM for 3 tons) against the coil’s pressure drop. Verify the existing blower’s motor can handle the added static.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After connecting the coil, run the system and measure total external static pressure. If the existing blower is a standard PSC motor, it may not compensate for the coil’s resistance, resulting in reduced airflow and poor dehumidification within the first cooling season. Documenting the airflow and static at startup provides a baseline for future service calls.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Verify refrigerant charge using the GZV7S subcooling method (target 9±1°F for the 3-ton unit with ⅜” liquid line). Use a calibrated digital manifold with R-32 profiles. Confirm the EEV in the coil is receiving proper control signal from the outdoor unit’s inverter board via the communicating connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e Even in coil-only configurations, R-32 charge limits per ASHRAE 15 apply. The indoor coil does not include a refrigerant sensor — confirm whether your local jurisdiction requires one based on the total system charge and the smallest room volume served. Document EPA Section 608 certification and system charge weight on the installation permit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Rated Performance:\u003c\/strong\u003e This AHRI-certified system achieves 15.0 SEER2 and 8.0 HSPF2, delivering measurable energy savings compared to minimum-efficiency (14.3 SEER2) systems. The variable-speed inverter compressor in the GZV7SA3610 modulates capacity to match the actual load, reducing short-cycling and improving humidity control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2,088). This supports compliance with EPA AIM Act phase-down requirements and positions this system for long-term refrigerant availability. R-32 also has higher volumetric cooling capacity, meaning smaller charge quantities for equivalent performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR® Cold Climate Certified:\u003c\/strong\u003e This combination meets the stringent ENERGY STAR Cold Climate criteria, verifying effective heating performance at outdoor temperatures down to 5°F. The GZV7SA3610 delivers 22,000 BTU\/h at 5°F, maintaining heat pump operation well below typical balance points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation with Sound Control:\u003c\/strong\u003e The GZV7SA3610 features a high-density compressor sound blanket, quiet digitally commutated fan motor, and field-selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA). The side-discharge cabinet design with grille-style sound control further reduces perceived noise at the property line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Intelligence \u0026amp; Communicating Control:\u003c\/strong\u003e The system includes a 7-segment LED display with fault code storage, proprietary Inside Intelligence for diagnostics, and full communicating capability requiring only two low-voltage wires between indoor and outdoor units. Compatible with the Goodman GTST connected thermostat for enhanced monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;max-width:700px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#333;color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217577967\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eHeat Pump Condenser and Evaporator Coil System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton (36,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e34,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 47°F\u003c\/td\u003e\n\u003ctd\u003e34,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd\u003e22,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit: GZV7SA3610\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e37” × 12⅝” × 39”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \/ Phase\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge (Factory)\u003c\/td\u003e\n\u003ctd\u003e100 oz (⅜” liquid line, 15 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil: CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e24½\" × 21\" × 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ ⅞\" or 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See ‘Resources (System Manuals and Warranty)’ Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;max-width:700px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — 68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirement\u003c\/td\u003e\n\u003ctd\u003eTechnician certification required for handling R-32. Recovery equipment must be A2L-rated.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions (DOE 2023 minimum efficiency standards met). Verify local A2L adoption status with your AHJ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR® Status\u003c\/td\u003e\n\u003ctd\u003eCold Climate Certified; Most Efficient 2025 (when matched per ENERGY STAR system requirements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility (IRA)\u003c\/td\u003e\n\u003ctd\u003eMay qualify for federal energy efficiency tax credits under 25C. Consult IRS guidance and a qualified tax professional for current eligibility and caps.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (applies to A2L refrigerant systems); ETL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eCertificate #217577967\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA3610 Heat Pump Condenser:\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when registered online within 60 days of installation at www.goodmanmfg.com. If the compressor fails within the first 10 years, Goodman will furnish a new equivalent outdoor unit (one-time replacement). Without registration, warranty coverage is limited to 5 years on all parts. One-time Compressor Replacement coverage is available for years 11–99 through an ASURE Extend Service Plan (available from ASURE dealers). Online registration is not required in California, Florida, or Québec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 Evaporator Coil:\u003c\/strong\u003e 10-Year Parts Limited Warranty when registered online within 60 days of installation at www.goodmanmfg.com. Without registration, warranty coverage is limited to 5 years on all parts. Registration is not required in California, Florida, or Québec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties provided by Daikin Comfort Technologies Manufacturing, Inc. Warranty applies to heating and air conditioning units installed in owner-occupied residences. Labor, refrigerant, freight, and associated installation costs are not covered. Refer to full warranty documents for complete terms, conditions, and exclusions.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658771267904,"sku":"GZV7SA3610-CAPEA6030D3-217577967","price":4961.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/uhjhluulled.jpg?v=1777747334"}],"url":"https:\/\/minisplitsystemsdirect.com\/collections\/goodman-3-ton-systems-15-0-seer2.oembed","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}