{"title":"Goodman, 3 Ton Systems, 16.6 SEER2","description":null,"products":[{"product_id":"goodman-gzv6sa3610-capea3626c3-grvt801005cx","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626C3 + GRVT801005CX | 21\" Cabinet Width | Upflow\/Downflow | Coil | 100,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Low NOx | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626C3) and a 100,000 BTU\/h 80% AFUE downflow gas furnace (GRVT801005CX). The system is AHRI certified (Certificate #215447197) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626C3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 21\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT801005CX\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 100,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Low NOx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447197\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e21\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Low NOx model complies with California SCAQMD Rule 1111 (≤40 NG\/J NOx). Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT801005CX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884442452288,"sku":"GM-GZV6SA3610-CAPEA3626C3-GRVT801005CX","price":6628.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-capea3626d3-grvt800805dx","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626D3 + GRVT800805DX | 24½\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Low NOx | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626D3) and a 80,000 BTU\/h 80% AFUE downflow gas furnace (GRVT800805DX). The system is AHRI certified (Certificate #215447198) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626D3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 24½\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT800805DX\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 24½\" cabinet width, Low NOx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447198\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e24½\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Low NOx model complies with California SCAQMD Rule 1111 (≤40 NG\/J NOx). Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT800805DX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884442648896,"sku":"GM-GZV6SA3610-CAPEA3626D3-GRVT800805DX","price":6518.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-chpea3626c3-gcvc800805cx","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CHPEA3626C3 + GCVC800805CX | Communicating | 26\" Cabinet Width | Horizontal | Coil | 80,000 BTU\/h | Downflow\/Horizontal | Two-Stage | Variable-Speed ECM | Low NOx | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a horizontal evaporator coil (CHPEA3626C3) and a 80,000 BTU\/h 80% AFUE downflow\/horizontal gas furnace (GCVC800805CX). The system is AHRI certified (Certificate #215488228) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic. Compatible with Goodman GTST connected thermostat and communicating equipment (ComfortBridge™ technology).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA3626C3\u003c\/strong\u003e — Goodman Horizontal Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 26\" W x 21\" D x 21\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVC800805CX\u003c\/strong\u003e — Goodman Downflow\/Horizontal Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Low NOx. Features integrated ComfortBridge™ communicating technology and CoolCloud™ Bluetooth diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e ComfortBridge™ technology enables full system communication between the outdoor unit, furnace, and compatible thermostat for optimized performance, streamlined installation, and advanced diagnostic capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215488228\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e26\" W x 21\" D x 21\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eYes (ComfortBridge™)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Low NOx model complies with California SCAQMD Rule 1111 (≤40 NG\/J NOx). Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GCVC800805CX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884443140416,"sku":"GM-GZV6SA3610-CHPEA3626C3-GCVC800805CX","price":6183.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/NEWNEWEHEFBEled_3.jpg?v=1777779429"},{"product_id":"goodman-gzv6sa3610-chpea3626c3-gdvt801005cx","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CHPEA3626C3 + GDVT801005CX | 26\" Cabinet Width | Horizontal | Coil | 100,000 BTU\/h | Downflow\/Horizontal | Two-Stage | Variable-Speed ECM | Low NOx | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a horizontal evaporator coil (CHPEA3626C3) and a 100,000 BTU\/h 80% AFUE downflow\/horizontal gas furnace (GDVT801005CX). The system is AHRI certified (Certificate #215447196) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA3626C3\u003c\/strong\u003e — Goodman Horizontal Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 26\" W x 21\" D x 21\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT801005CX\u003c\/strong\u003e — Goodman Downflow\/Horizontal Two-Stage Variable-Speed ECM gas furnace. 100,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Low NOx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447196\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e26\" W x 21\" D x 21\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Low NOx model complies with California SCAQMD Rule 1111 (≤40 NG\/J NOx). Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GDVT801005CX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884443435328,"sku":"GM-GZV6SA3610-CHPEA3626C3-GDVT801005CX","price":6591.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-capea3626d3-grvm971205dn","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626D3 + GRVM971205DN | 24½\" Cabinet Width | Upflow\/Downflow | Coil | 120,000 BTU\/h | Upflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626D3) and a 120,000 BTU\/h 97% AFUE upflow\/horizontal gas furnace (GRVM971205DN). The system is AHRI certified (Certificate #215447217) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626D3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 24½\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM971205DN\u003c\/strong\u003e — Goodman Upflow\/Horizontal Modulating Variable-Speed ECM gas furnace. 120,000 BTU\/h input, 97% AFUE. 24½\" cabinet width, Natural Gas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447217\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e24½\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e120,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVM971205DN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884443533632,"sku":"GM-GZV6SA3610-CAPEA3626D3-GRVM971205DN","price":8024.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-capea3626d3-grvt800804cn","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626D3 + GRVT800804CN | 24½\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626D3) and a 80,000 BTU\/h 80% AFUE downflow gas furnace (GRVT800804CN). The system is AHRI certified (Certificate #215447202) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626D3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 24½\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT800804CN\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Natural Gas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e24½\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT800804CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884443828544,"sku":"GM-GZV6SA3610-CAPEA3626D3-GRVT800804CN","price":6439.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-chpea3626c3-grvt800804cn","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CHPEA3626C3 + GRVT800804CN | 26\" Cabinet Width | Horizontal | Coil | 80,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a horizontal evaporator coil (CHPEA3626C3) and a 80,000 BTU\/h 80% AFUE downflow gas furnace (GRVT800804CN). The system is AHRI certified (Certificate #215447201) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA3626C3\u003c\/strong\u003e — Goodman Horizontal Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 26\" W x 21\" D x 21\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT800804CN\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Natural Gas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e26\" W x 21\" D x 21\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT800804CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884444320064,"sku":"GM-GZV6SA3610-CHPEA3626C3-GRVT800804CN","price":6323.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-capea3626c3-grvt800805cx","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626C3 + GRVT800805CX | 21\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Low NOx | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626C3) and a 80,000 BTU\/h 80% AFUE downflow gas furnace (GRVT800805CX). The system is AHRI certified (Certificate #215447200) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626C3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 21\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT800805CX\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Low NOx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e21\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Low NOx model complies with California SCAQMD Rule 1111 (≤40 NG\/J NOx). Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT800805CX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884444516672,"sku":"GM-GZV6SA3610-CAPEA3626C3-GRVT800805CX","price":6488.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-chpea3626c3-grvt801005cx","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CHPEA3626C3 + GRVT801005CX | 26\" Cabinet Width | Horizontal | Coil | 100,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Low NOx | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a horizontal evaporator coil (CHPEA3626C3) and a 100,000 BTU\/h 80% AFUE downflow gas furnace (GRVT801005CX). The system is AHRI certified (Certificate #215447196) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA3626C3\u003c\/strong\u003e — Goodman Horizontal Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 26\" W x 21\" D x 21\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT801005CX\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 100,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Low NOx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447196\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e26\" W x 21\" D x 21\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Low NOx model complies with California SCAQMD Rule 1111 (≤40 NG\/J NOx). Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT801005CX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884444877120,"sku":"GM-GZV6SA3610-CHPEA3626C3-GRVT801005CX","price":6521.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-capea3626c3-grvt801005cn","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626C3 + GRVT801005CN | 21\" Cabinet Width | Upflow\/Downflow | Coil | 100,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626C3) and a 100,000 BTU\/h 80% AFUE downflow gas furnace (GRVT801005CN). The system is AHRI certified (Certificate #215447197) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626C3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 21\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT801005CN\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 100,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Natural Gas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447197\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e21\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT801005CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884445204800,"sku":"GM-GZV6SA3610-CAPEA3626C3-GRVT801005CN","price":6628.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-capea3626d3-grvt800805cn","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626D3 + GRVT800805CN | 24½\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626D3) and a 80,000 BTU\/h 80% AFUE downflow gas furnace (GRVT800805CN). The system is AHRI certified (Certificate #215447200) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626D3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 24½\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT800805CN\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Natural Gas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e24½\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT800805CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884445794624,"sku":"GM-GZV6SA3610-CAPEA3626D3-GRVT800805CN","price":6497.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-chpea3626c3-grvt800804cx","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CHPEA3626C3 + GRVT800804CX | 26\" Cabinet Width | Horizontal | Coil | 80,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Low NOx | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a horizontal evaporator coil (CHPEA3626C3) and a 80,000 BTU\/h 80% AFUE downflow gas furnace (GRVT800804CX). The system is AHRI certified (Certificate #215447201) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA3626C3\u003c\/strong\u003e — Goodman Horizontal Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 26\" W x 21\" D x 21\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT800804CX\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Low NOx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e26\" W x 21\" D x 21\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Low NOx model complies with California SCAQMD Rule 1111 (≤40 NG\/J NOx). Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT800804CX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884446024000,"sku":"GM-GZV6SA3610-CHPEA3626C3-GRVT800804CX","price":6323.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-capea3626c3-gdvt801005cx","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626C3 + GDVT801005CX | 21\" Cabinet Width | Upflow\/Downflow | Coil | 100,000 BTU\/h | Downflow\/Horizontal | Two-Stage | Variable-Speed ECM | Low NOx | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626C3) and a 100,000 BTU\/h 80% AFUE downflow\/horizontal gas furnace (GDVT801005CX). The system is AHRI certified (Certificate #215447197) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626C3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 21\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT801005CX\u003c\/strong\u003e — Goodman Downflow\/Horizontal Two-Stage Variable-Speed ECM gas furnace. 100,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Low NOx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447197\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e21\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Low NOx model complies with California SCAQMD Rule 1111 (≤40 NG\/J NOx). Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GDVT801005CX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884446155072,"sku":"GM-GZV6SA3610-CAPEA3626C3-GDVT801005CX","price":6698.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-chpea3626c3-grvt801005cn","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CHPEA3626C3 + GRVT801005CN | 26\" Cabinet Width | Horizontal | Coil | 100,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a horizontal evaporator coil (CHPEA3626C3) and a 100,000 BTU\/h 80% AFUE downflow gas furnace (GRVT801005CN). The system is AHRI certified (Certificate #215447196) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA3626C3\u003c\/strong\u003e — Goodman Horizontal Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 26\" W x 21\" D x 21\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT801005CN\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 100,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Natural Gas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447196\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e26\" W x 21\" D x 21\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT801005CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884446417216,"sku":"GM-GZV6SA3610-CHPEA3626C3-GRVT801005CN","price":6521.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-capea3626d3-gdvt801005cx","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626D3 + GDVT801005CX | 24½\" Cabinet Width | Upflow\/Downflow | Coil | 100,000 BTU\/h | Downflow\/Horizontal | Two-Stage | Variable-Speed ECM | Low NOx | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626D3) and a 100,000 BTU\/h 80% AFUE downflow\/horizontal gas furnace (GDVT801005CX). The system is AHRI certified (Certificate #215447197) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626D3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 24½\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT801005CX\u003c\/strong\u003e — Goodman Downflow\/Horizontal Two-Stage Variable-Speed ECM gas furnace. 100,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Low NOx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447197\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e24½\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Low NOx model complies with California SCAQMD Rule 1111 (≤40 NG\/J NOx). Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GDVT801005CX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884446646592,"sku":"GM-GZV6SA3610-CAPEA3626D3-GDVT801005CX","price":6707.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-capea3626c3-grvt800805cn","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626C3 + GRVT800805CN | 21\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626C3) and a 80,000 BTU\/h 80% AFUE downflow gas furnace (GRVT800805CN). The system is AHRI certified (Certificate #215447200) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626C3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 21\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT800805CN\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Natural Gas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e21\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT800805CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884446908736,"sku":"GM-GZV6SA3610-CAPEA3626C3-GRVT800805CN","price":6488.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-capea3626d3-grvt961205dn","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626D3 + GRVT961205DN | 24½\" Cabinet Width | Upflow\/Downflow | Coil | 120,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626D3) and a 120,000 BTU\/h 96% AFUE downflow gas furnace (GRVT961205DN). The system is AHRI certified (Certificate #215447184) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626D3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 24½\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961205DN\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 120,000 BTU\/h input, 96% AFUE. 24½\" cabinet width, Natural Gas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447184\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e24½\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e120,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT961205DN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884447039808,"sku":"GM-GZV6SA3610-CAPEA3626D3-GRVT961205DN","price":7531.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-capea3626d3-grvt800805cx","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626D3 + GRVT800805CX | 24½\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Low NOx | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626D3) and a 80,000 BTU\/h 80% AFUE downflow gas furnace (GRVT800805CX). The system is AHRI certified (Certificate #215447200) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626D3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 24½\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT800805CX\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Low NOx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e24½\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Low NOx model complies with California SCAQMD Rule 1111 (≤40 NG\/J NOx). Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT800805CX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884447138112,"sku":"GM-GZV6SA3610-CAPEA3626D3-GRVT800805CX","price":6497.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-capea3626d3-grvt801005cn","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626D3 + GRVT801005CN | 24½\" Cabinet Width | Upflow\/Downflow | Coil | 100,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626D3) and a 100,000 BTU\/h 80% AFUE downflow gas furnace (GRVT801005CN). The system is AHRI certified (Certificate #215447197) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626D3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 24½\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT801005CN\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 100,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Natural Gas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447197\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e24½\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT801005CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884447465792,"sku":"GM-GZV6SA3610-CAPEA3626D3-GRVT801005CN","price":6637.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-capea3626c3-grvt800804cn","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626C3 + GRVT800804CN | 21\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626C3) and a 80,000 BTU\/h 80% AFUE downflow gas furnace (GRVT800804CN). The system is AHRI certified (Certificate #215447202) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626C3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 21\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT800804CN\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Natural Gas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e21\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT800804CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884448284992,"sku":"GM-GZV6SA3610-CAPEA3626C3-GRVT800804CN","price":6430.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-chpea3626c3-grvt800805cx","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CHPEA3626C3 + GRVT800805CX | 26\" Cabinet Width | Horizontal | Coil | 80,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Low NOx | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a horizontal evaporator coil (CHPEA3626C3) and a 80,000 BTU\/h 80% AFUE downflow gas furnace (GRVT800805CX). The system is AHRI certified (Certificate #215447199) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA3626C3\u003c\/strong\u003e — Goodman Horizontal Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 26\" W x 21\" D x 21\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT800805CX\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Low NOx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e26\" W x 21\" D x 21\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Low NOx model complies with California SCAQMD Rule 1111 (≤40 NG\/J NOx). Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT800805CX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884448383296,"sku":"GM-GZV6SA3610-CHPEA3626C3-GRVT800805CX","price":6381.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-capea3626c3-grvt800804cx","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626C3 + GRVT800804CX | 21\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Low NOx | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626C3) and a 80,000 BTU\/h 80% AFUE downflow gas furnace (GRVT800804CX). The system is AHRI certified (Certificate #215447202) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626C3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 21\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT800804CX\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Low NOx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e21\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Low NOx model complies with California SCAQMD Rule 1111 (≤40 NG\/J NOx). Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT800804CX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884448678208,"sku":"GM-GZV6SA3610-CAPEA3626C3-GRVT800804CX","price":6430.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-capea3626d3-grvt800804cx","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626D3 + GRVT800804CX | 24½\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Low NOx | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow\/downflow evaporator coil (CAPEA3626D3) and a 80,000 BTU\/h 80% AFUE downflow gas furnace (GRVT800804CX). The system is AHRI certified (Certificate #215447202) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626D3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 24½\" W x 21\" D x 26\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT800804CX\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Low NOx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e24½\" W x 21\" D x 26\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Low NOx model complies with California SCAQMD Rule 1111 (≤40 NG\/J NOx). Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT800804CX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884449333568,"sku":"GM-GZV6SA3610-CAPEA3626D3-GRVT800804CX","price":6439.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-chpea3626c3-grvt800805cn","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CHPEA3626C3 + GRVT800805CN | 26\" Cabinet Width | Horizontal | Coil | 80,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a horizontal evaporator coil (CHPEA3626C3) and a 80,000 BTU\/h 80% AFUE downflow gas furnace (GRVT800805CN). The system is AHRI certified (Certificate #215447199) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA3626C3\u003c\/strong\u003e — Goodman Horizontal Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 26\" W x 21\" D x 21\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT800805CN\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Natural Gas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e26\" W x 21\" D x 21\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT800805CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884449661248,"sku":"GM-GZV6SA3610-CHPEA3626C3-GRVT800805CN","price":6381.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779"},{"product_id":"goodman-gzv6sa3610-chpea3626c3-gmvc800804cx","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CHPEA3626C3 + GMVC800804CX | Communicating | 26\" Cabinet Width | Horizontal | Coil | 80,000 BTU\/h | Upflow\/Horizontal | Two-Stage | Variable-Speed ECM | Low NOx | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a horizontal evaporator coil (CHPEA3626C3) and a 80,000 BTU\/h 80% AFUE upflow\/horizontal gas furnace (GMVC800804CX). The system is AHRI certified (Certificate #215488230) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic. Compatible with Goodman GTST connected thermostat and communicating equipment (ComfortBridge™ technology).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA3626C3\u003c\/strong\u003e — Goodman Horizontal Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 26\" W x 21\" D x 21\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVC800804CX\u003c\/strong\u003e — Goodman Upflow\/Horizontal Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Low NOx. Features integrated ComfortBridge™ communicating technology and CoolCloud™ Bluetooth diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e ComfortBridge™ technology enables full system communication between the outdoor unit, furnace, and compatible thermostat for optimized performance, streamlined installation, and advanced diagnostic capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215488230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e26\" W x 21\" D x 21\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eYes (ComfortBridge™)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Low NOx model complies with California SCAQMD Rule 1111 (≤40 NG\/J NOx). Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVC800804CX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884449825088,"sku":"GM-GZV6SA3610-CHPEA3626C3-GMVC800804CX","price":6070.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/GHCYUKCJHVKJtitled.jpg?v=1777345299"},{"product_id":"goodman-gzv6sa3610-ahve36cp0300-215429786","title":"Goodman 3 Ton 16.6 SEER2 R-32 Central Heat Pump Split System | GZV6SA3610 + AHVE36CP0300 | 21\" Cabinet Width, Multi-Positional Air Handler","description":"\u003cp\u003eThis Goodman 3-Ton Central Heat Pump Split System combines the GZV6SA3610* variable-speed heat pump condenser with the AHVE36CP0300 variable-speed air handler. AHRI-certified (Certificate #215429786) at 16.6 SEER2 and 8.5 HSPF2, this matched system uses R-32 low-GWP refrigerant and provides both heating and cooling from a single all-electric platform. The air handler features an integrated EEV and communicating variable-speed ECM blower for precise airflow and humidity management.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump Condenser:\u003c\/strong\u003e Goodman GZV6SA3610* — 3-Ton variable-speed inverter-driven R-32 heat pump with swing compressor, EEV metering, and digitally commutated condenser fan motor. Sound power as low as 45 dBA in quiet mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Handler:\u003c\/strong\u003e Goodman AHVE36CP0300A* — 3-Ton Multi-Positional variable-speed ECM air handler (115V) with integrated EEV, all-aluminum evaporator coil, factory-installed R-32 sensor, and SmartFrame cabinet with less than 2% air leakage. 21\" depth for attic access compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The AHVE air handler's 21\" cabinet depth enables attic installations, but the 53-7\/16\" overall height requires careful verification of available vertical clearance, especially under low-pitch rafters. The coil mounting track allows repositioning, but suction and liquid line routing must accommodate the final coil orientation without kinking.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After positioning the air handler, install the condensate drain trap before running the system. The thermoplastic drain pan includes secondary drain connections — always pipe the secondary to a visible location (like over a window) as an overflow indicator. This single step prevents 90% of water-damage callbacks within the first year.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use the CoolCloud app during commissioning to verify the communicating link between the outdoor unit and air handler. Confirm the EEV superheat is auto-controlled and the subcooling at the outdoor service valve reads 15 +\/- 1 deg.F using a digital manifold gauge.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e Verify the return air duct connections meet the ASHRAE 193 cabinet air leakage standard (less than 2% at 1.0\" w.c.). Apply UL-listed mastic sealant at all duct-to-cabinet joints. In jurisdictions requiring Manual J load calculations, confirm the selected tonnage matches the calculated cooling load to avoid oversizing, which degrades dehumidification performance.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Electric Operation:\u003c\/strong\u003e No combustion, no flue venting, and no gas line required — this all-electric heat pump system simplifies installation and eliminates carbon monoxide risk in the conditioned space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Seasonal Efficiency:\u003c\/strong\u003e 16.6 SEER2 cooling and 8.5 HSPF2 heating ratings deliver substantial energy savings over standard-efficiency equipment, potentially qualifying for federal tax credits under the Inflation Reduction Act.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The outdoor inverter compressor and indoor ECM blower motor modulate to match the actual load, reducing temperature swings, improving humidity removal, and lowering sound levels during part-load operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a 68% lower global warming potential than R-410A and provides higher volumetric cooling capacity, supporting compliance with the AIM Act refrigerant phasedown schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated EEV Metering:\u003c\/strong\u003e The factory-installed electronic expansion valve in the air handler provides precise refrigerant flow control across all operating conditions, eliminating the need for field-installed metering devices and piston kits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The outdoor unit operates as low as 45 dBA in quiet mode, and the variable-speed air handler reduces blower noise at part-load by running at lower speeds.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance (AHRI Certificate #215429786)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA3610*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @17°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 71 dBA (as low as 45 dBA in quiet mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e36-5\/8\" x 13-3\/4\" x 27-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e137 lbs \/ 151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e83 oz (factory charge for 15' line set)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eAir Handler — AHVE36CP0300A*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3-Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 53-7\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e3\/4 HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e10.4A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e140 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane) — A2L (mildly flammable) classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eEPA-certified technician required for refrigerant handling; R-32 requires A2L-rated recovery equipment and leak detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll-region sales designation (Region A); verify local A2L refrigerant installation codes and charge density limits per ASHRAE 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eHeat pump systems meeting efficiency thresholds may qualify for federal tax credits under the Inflation Reduction Act (25C) — consult a qualified tax professional for current eligibility requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAHRI Certified; ETL Listed; ENERGY STAR (when matched with qualifying indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Goodman will furnish a new replacement outdoor unit (one time). Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Handler (AHVE36CP0300A*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties apply to owner-occupied residential installations only. Different terms apply to commercial and rental properties. Labor, refrigerant, freight, and other service costs are not covered. Complete warranty details are available at goodmanmfg.com.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884451397952,"sku":"GZV6SA3610-AHVE36CP0300-215429786","price":5452.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/jtyjyjtyjytled.jpg?v=1777777375"},{"product_id":"goodman-gzv6sa3610-ahve36cp1300-215429193","title":"Goodman 3 Ton 16.6 SEER2 R-32 Central Heat Pump Split System | GZV6SA3610 + AHVE36CP1300 | 21\" Cabinet Width, Multi-Positional Air Handler","description":"\u003cp\u003eThis Goodman 3-Ton Central Heat Pump Split System combines the GZV6SA3610* variable-speed heat pump condenser with the AHVE36CP1300 variable-speed air handler. AHRI-certified (Certificate #215429193) at 16.6 SEER2 and 8.5 HSPF2, this matched system uses R-32 low-GWP refrigerant and provides both heating and cooling from a single all-electric platform. The air handler features an integrated EEV and communicating variable-speed ECM blower for precise airflow and humidity management.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump Condenser:\u003c\/strong\u003e Goodman GZV6SA3610* — 3-Ton variable-speed inverter-driven R-32 heat pump with swing compressor, EEV metering, and digitally commutated condenser fan motor. Sound power as low as 45 dBA in quiet mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Handler:\u003c\/strong\u003e Goodman AHVE36CP1300A* — 3-Ton Multi-Positional variable-speed ECM air handler (208\/230V) with integrated EEV, all-aluminum evaporator coil, factory-installed R-32 sensor, and SmartFrame cabinet with less than 2% air leakage. 21\" depth for attic access compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The AHVE air handler's 21\" cabinet depth enables attic installations, but the 53-7\/16\" overall height requires careful verification of available vertical clearance, especially under low-pitch rafters. The coil mounting track allows repositioning, but suction and liquid line routing must accommodate the final coil orientation without kinking.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After positioning the air handler, install the condensate drain trap before running the system. The thermoplastic drain pan includes secondary drain connections — always pipe the secondary to a visible location (like over a window) as an overflow indicator. This single step prevents 90% of water-damage callbacks within the first year.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use the CoolCloud app during commissioning to verify the communicating link between the outdoor unit and air handler. Confirm the EEV superheat is auto-controlled and the subcooling at the outdoor service valve reads 15 +\/- 1 deg.F using a digital manifold gauge.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e Verify the return air duct connections meet the ASHRAE 193 cabinet air leakage standard (less than 2% at 1.0\" w.c.). Apply UL-listed mastic sealant at all duct-to-cabinet joints. In jurisdictions requiring Manual J load calculations, confirm the selected tonnage matches the calculated cooling load to avoid oversizing, which degrades dehumidification performance.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Electric Operation:\u003c\/strong\u003e No combustion, no flue venting, and no gas line required — this all-electric heat pump system simplifies installation and eliminates carbon monoxide risk in the conditioned space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Seasonal Efficiency:\u003c\/strong\u003e 16.6 SEER2 cooling and 8.5 HSPF2 heating ratings deliver substantial energy savings over standard-efficiency equipment, potentially qualifying for federal tax credits under the Inflation Reduction Act.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The outdoor inverter compressor and indoor ECM blower motor modulate to match the actual load, reducing temperature swings, improving humidity removal, and lowering sound levels during part-load operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a 68% lower global warming potential than R-410A and provides higher volumetric cooling capacity, supporting compliance with the AIM Act refrigerant phasedown schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated EEV Metering:\u003c\/strong\u003e The factory-installed electronic expansion valve in the air handler provides precise refrigerant flow control across all operating conditions, eliminating the need for field-installed metering devices and piston kits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The outdoor unit operates as low as 45 dBA in quiet mode, and the variable-speed air handler reduces blower noise at part-load by running at lower speeds.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance (AHRI Certificate #215429193)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA3610*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @17°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 71 dBA (as low as 45 dBA in quiet mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e36-5\/8\" x 13-3\/4\" x 27-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e137 lbs \/ 151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e83 oz (factory charge for 15' line set)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eAir Handler — AHVE36CP1300A*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3-Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 53-7\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e3\/4 HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e6.5A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e140 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane) — A2L (mildly flammable) classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eEPA-certified technician required for refrigerant handling; R-32 requires A2L-rated recovery equipment and leak detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll-region sales designation (Region A); verify local A2L refrigerant installation codes and charge density limits per ASHRAE 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eHeat pump systems meeting efficiency thresholds may qualify for federal tax credits under the Inflation Reduction Act (25C) — consult a qualified tax professional for current eligibility requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAHRI Certified; ETL Listed; ENERGY STAR (when matched with qualifying indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Goodman will furnish a new replacement outdoor unit (one time). Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Handler (AHVE36CP1300A*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties apply to owner-occupied residential installations only. Different terms apply to commercial and rental properties. Labor, refrigerant, freight, and other service costs are not covered. Complete warranty details are available at goodmanmfg.com.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884451496256,"sku":"GZV6SA3610-AHVE36CP1300-215429193","price":5452.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/jtyjyjtyjytled.jpg?v=1777777375"},{"product_id":"goodman-gzv6sa3610-ahve42cp0300-215429788","title":"Goodman 3 Ton 16.6 SEER2 R-32 Central Heat Pump Split System | GZV6SA3610 + AHVE42CP0300 | 21\" Cabinet Width, Multi-Positional Air Handler","description":"\u003cp\u003eThis Goodman 3-Ton Central Heat Pump Split System combines the GZV6SA3610* variable-speed heat pump condenser with the AHVE42CP0300 variable-speed air handler. AHRI-certified (Certificate #215429788) at 16.6 SEER2 and 8.5 HSPF2, this matched system uses R-32 low-GWP refrigerant and provides both heating and cooling from a single all-electric platform. The air handler features an integrated EEV and communicating variable-speed ECM blower for precise airflow and humidity management.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump Condenser:\u003c\/strong\u003e Goodman GZV6SA3610* — 3-Ton variable-speed inverter-driven R-32 heat pump with swing compressor, EEV metering, and digitally commutated condenser fan motor. Sound power as low as 45 dBA in quiet mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Handler:\u003c\/strong\u003e Goodman AHVE42CP0300A* — 3.5-Ton Multi-Positional variable-speed ECM air handler (115V) with integrated EEV, all-aluminum evaporator coil, factory-installed R-32 sensor, and SmartFrame cabinet with less than 2% air leakage. 21\" depth for attic access compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The AHVE air handler's 21\" cabinet depth enables attic installations, but the 53-7\/16\" overall height requires careful verification of available vertical clearance, especially under low-pitch rafters. The coil mounting track allows repositioning, but suction and liquid line routing must accommodate the final coil orientation without kinking.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After positioning the air handler, install the condensate drain trap before running the system. The thermoplastic drain pan includes secondary drain connections — always pipe the secondary to a visible location (like over a window) as an overflow indicator. This single step prevents 90% of water-damage callbacks within the first year.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use the CoolCloud app during commissioning to verify the communicating link between the outdoor unit and air handler. Confirm the EEV superheat is auto-controlled and the subcooling at the outdoor service valve reads 15 +\/- 1 deg.F using a digital manifold gauge.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e Verify the return air duct connections meet the ASHRAE 193 cabinet air leakage standard (less than 2% at 1.0\" w.c.). Apply UL-listed mastic sealant at all duct-to-cabinet joints. In jurisdictions requiring Manual J load calculations, confirm the selected tonnage matches the calculated cooling load to avoid oversizing, which degrades dehumidification performance.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Electric Operation:\u003c\/strong\u003e No combustion, no flue venting, and no gas line required — this all-electric heat pump system simplifies installation and eliminates carbon monoxide risk in the conditioned space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Seasonal Efficiency:\u003c\/strong\u003e 16.6 SEER2 cooling and 8.5 HSPF2 heating ratings deliver substantial energy savings over standard-efficiency equipment, potentially qualifying for federal tax credits under the Inflation Reduction Act.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The outdoor inverter compressor and indoor ECM blower motor modulate to match the actual load, reducing temperature swings, improving humidity removal, and lowering sound levels during part-load operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a 68% lower global warming potential than R-410A and provides higher volumetric cooling capacity, supporting compliance with the AIM Act refrigerant phasedown schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated EEV Metering:\u003c\/strong\u003e The factory-installed electronic expansion valve in the air handler provides precise refrigerant flow control across all operating conditions, eliminating the need for field-installed metering devices and piston kits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The outdoor unit operates as low as 45 dBA in quiet mode, and the variable-speed air handler reduces blower noise at part-load by running at lower speeds.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance (AHRI Certificate #215429788)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA3610*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @17°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 71 dBA (as low as 45 dBA in quiet mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e36-5\/8\" x 13-3\/4\" x 27-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e137 lbs \/ 151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e83 oz (factory charge for 15' line set)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eAir Handler — AHVE42CP0300A*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3.5-Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 53-7\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e3\/4 HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e10.4A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e140 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane) — A2L (mildly flammable) classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eEPA-certified technician required for refrigerant handling; R-32 requires A2L-rated recovery equipment and leak detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll-region sales designation (Region A); verify local A2L refrigerant installation codes and charge density limits per ASHRAE 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eHeat pump systems meeting efficiency thresholds may qualify for federal tax credits under the Inflation Reduction Act (25C) — consult a qualified tax professional for current eligibility requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAHRI Certified; ETL Listed; ENERGY STAR (when matched with qualifying indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Goodman will furnish a new replacement outdoor unit (one time). Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Handler (AHVE42CP0300A*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties apply to owner-occupied residential installations only. Different terms apply to commercial and rental properties. Labor, refrigerant, freight, and other service costs are not covered. Complete warranty details are available at goodmanmfg.com.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884451561792,"sku":"GZV6SA3610-AHVE42CP0300-215429788","price":5534.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/jtyjyjtyjytled.jpg?v=1777777375"},{"product_id":"goodman-gzv6sa3610-ahve42cp1300-215429787","title":"Goodman 3 Ton 16.6 SEER2 R-32 Central Heat Pump Split System | GZV6SA3610 + AHVE42CP1300 | 21\" Cabinet Width, Multi-Positional Air Handler","description":"\u003cp\u003eThis Goodman 3-Ton Central Heat Pump Split System combines the GZV6SA3610* variable-speed heat pump condenser with the AHVE42CP1300 variable-speed air handler. AHRI-certified (Certificate #215429787) at 16.6 SEER2 and 8.5 HSPF2, this matched system uses R-32 low-GWP refrigerant and provides both heating and cooling from a single all-electric platform. The air handler features an integrated EEV and communicating variable-speed ECM blower for precise airflow and humidity management.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump Condenser:\u003c\/strong\u003e Goodman GZV6SA3610* — 3-Ton variable-speed inverter-driven R-32 heat pump with swing compressor, EEV metering, and digitally commutated condenser fan motor. Sound power as low as 45 dBA in quiet mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Handler:\u003c\/strong\u003e Goodman AHVE42CP1300A* — 3.5-Ton Multi-Positional variable-speed ECM air handler (208\/230V) with integrated EEV, all-aluminum evaporator coil, factory-installed R-32 sensor, and SmartFrame cabinet with less than 2% air leakage. 21\" depth for attic access compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The AHVE air handler's 21\" cabinet depth enables attic installations, but the 53-7\/16\" overall height requires careful verification of available vertical clearance, especially under low-pitch rafters. The coil mounting track allows repositioning, but suction and liquid line routing must accommodate the final coil orientation without kinking.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After positioning the air handler, install the condensate drain trap before running the system. The thermoplastic drain pan includes secondary drain connections — always pipe the secondary to a visible location (like over a window) as an overflow indicator. This single step prevents 90% of water-damage callbacks within the first year.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use the CoolCloud app during commissioning to verify the communicating link between the outdoor unit and air handler. Confirm the EEV superheat is auto-controlled and the subcooling at the outdoor service valve reads 15 +\/- 1 deg.F using a digital manifold gauge.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e Verify the return air duct connections meet the ASHRAE 193 cabinet air leakage standard (less than 2% at 1.0\" w.c.). Apply UL-listed mastic sealant at all duct-to-cabinet joints. In jurisdictions requiring Manual J load calculations, confirm the selected tonnage matches the calculated cooling load to avoid oversizing, which degrades dehumidification performance.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Electric Operation:\u003c\/strong\u003e No combustion, no flue venting, and no gas line required — this all-electric heat pump system simplifies installation and eliminates carbon monoxide risk in the conditioned space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Seasonal Efficiency:\u003c\/strong\u003e 16.6 SEER2 cooling and 8.5 HSPF2 heating ratings deliver substantial energy savings over standard-efficiency equipment, potentially qualifying for federal tax credits under the Inflation Reduction Act.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The outdoor inverter compressor and indoor ECM blower motor modulate to match the actual load, reducing temperature swings, improving humidity removal, and lowering sound levels during part-load operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a 68% lower global warming potential than R-410A and provides higher volumetric cooling capacity, supporting compliance with the AIM Act refrigerant phasedown schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated EEV Metering:\u003c\/strong\u003e The factory-installed electronic expansion valve in the air handler provides precise refrigerant flow control across all operating conditions, eliminating the need for field-installed metering devices and piston kits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The outdoor unit operates as low as 45 dBA in quiet mode, and the variable-speed air handler reduces blower noise at part-load by running at lower speeds.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance (AHRI Certificate #215429787)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA3610*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @17°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 71 dBA (as low as 45 dBA in quiet mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e36-5\/8\" x 13-3\/4\" x 27-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e137 lbs \/ 151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e83 oz (factory charge for 15' line set)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eAir Handler — AHVE42CP1300A*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3.5-Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 53-7\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e3\/4 HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e6.5A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e140 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane) — A2L (mildly flammable) classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eEPA-certified technician required for refrigerant handling; R-32 requires A2L-rated recovery equipment and leak detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll-region sales designation (Region A); verify local A2L refrigerant installation codes and charge density limits per ASHRAE 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eHeat pump systems meeting efficiency thresholds may qualify for federal tax credits under the Inflation Reduction Act (25C) — consult a qualified tax professional for current eligibility requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAHRI Certified; ETL Listed; ENERGY STAR (when matched with qualifying indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Goodman will furnish a new replacement outdoor unit (one time). Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Handler (AHVE42CP1300A*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties apply to owner-occupied residential installations only. Different terms apply to commercial and rental properties. Labor, refrigerant, freight, and other service costs are not covered. Complete warranty details are available at goodmanmfg.com.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884451660096,"sku":"GZV6SA3610-AHVE42CP1300-215429787","price":5534.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/jtyjyjtyjytled.jpg?v=1777777375"},{"product_id":"goodman-gzv6sa3610-capea3626b3-mbvk12bp1x00-215447183","title":"Goodman 3 Ton 16.6 SEER2 R-32 Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower | GZV6SA3610 + CAPEA3626B3 + MBVK12BP1X00 | 21\" Depth, Upflow\/Downflow Coil","description":"\u003cp\u003eThis Goodman 3-Ton Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower pairs the GZV6SA3610* variable-speed heat pump with the CAPEA3626B3 evaporator coil and MBVK12BP1X00 communicating modular blower. AHRI-certified (Certificate #215447183) at 16.6 SEER2 and 8.5 HSPF2, this configuration uses R-32 low-GWP refrigerant and provides efficient all-electric heating and cooling. The modular blower and coil design offers flexible installation options in both vertical and horizontal orientations.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump Condenser:\u003c\/strong\u003e Goodman GZV6SA3610* — 3-Ton variable-speed inverter-driven R-32 heat pump with swing compressor, EEV metering, and digitally commutated condenser fan motor. Sound power as low as 45 dBA in quiet mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil:\u003c\/strong\u003e Goodman CAPEA3626B3A* — 3-Ton cased Upflow\/Downflow all-aluminum evaporator coil with integrated EEV, factory-installed R-32 sensor, and thermoplastic drain pan with secondary drain connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower:\u003c\/strong\u003e Goodman MBVK12BP1X00AA — 1200-CFM variable-speed ECM communicating modular blower (17-1\/2\") with SmartFrame cabinet, integrated ComfortBridge technology, and built-in dehumidification feature. Compatible with R-32 refrigerant with integration kit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The two-piece coil-and-blower configuration offers installation flexibility, but the coil width must match the blower cabinet width for a proper seal. Mismatched widths create air bypass around the coil face, reducing system capacity and triggering low-superheat fault codes from the outdoor unit's EEV controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After mounting the coil on the blower, verify the drain pan rail alignment and apply foil-faced tape at the coil-to-blower junction seam. Pressure-test the completed assembly with a duct leakage tester — total air leakage should remain below 2% at 1.0\" w.c. per ASHRAE 193. This prevents efficiency loss and condensation issues that often surface 6-8 months after installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Verify the communicating connection between the MBVK blower, the evaporator coil's EEV, and the outdoor unit through the CoolCloud app. Confirm the blower is configured for the correct tonnage setting and that the EEV superheat is auto-controlled, with subcooling reading 15 +\/- 1 deg.F at the outdoor unit's service valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e The R-32 integration kit must be installed on the blower for R-32 compatibility. Verify the R-32 leak sensor on the coil is functional before sealing the access panel. In jurisdictions enforcing ASHRAE 15 or state-level A2L refrigerant handling requirements, ensure the installation meets maximum charge density limits for the occupied space.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Installation Flexibility:\u003c\/strong\u003e The separate coil and blower design allows each component to be positioned independently, accommodating tight mechanical closets, attics, and crawl spaces where a single-piece air handler may not fit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Seasonal Efficiency:\u003c\/strong\u003e 16.6 SEER2 cooling and 8.5 HSPF2 heating ratings maximize energy savings across both seasons, potentially qualifying for federal tax credits and utility rebates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The variable-speed outdoor compressor and communicating ECM blower motor work together to modulate airflow and capacity, delivering consistent temperatures and improved dehumidification at part-load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a 68% lower global warming potential than R-410A and offers higher volumetric cooling capacity, supporting the industry transition under the AIM Act phasedown schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating Integration:\u003c\/strong\u003e The MBVK blower's ComfortBridge technology communicates directly with the outdoor unit and compatible thermostat, enabling automated airflow configuration, tonnage matching, and diagnostic reporting through the CoolCloud app.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance (AHRI Certificate #215447183)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA3610*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @17°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 71 dBA (as low as 45 dBA in quiet mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e36-5\/8\" x 13-3\/4\" x 27-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e137 lbs \/ 151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e83 oz (factory charge for 15' line set)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CAPEA3626B3A*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e17-1\/2\" x 21\" x 26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e5\/16\" or 3\/8\" \/ 3\/4\" or 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e54 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eModular Blower — MBVK12BP1X00AA\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional (Vertical \/ Horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003eUp to 1200 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e17-1\/2\" x 21\" x 26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e4.9A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e67 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane) — A2L (mildly flammable) classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eEPA-certified technician required for refrigerant handling; R-32 requires A2L-rated recovery equipment and leak detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll-region sales designation (Region A); verify local A2L refrigerant installation codes and charge density limits per ASHRAE 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eHeat pump systems meeting efficiency thresholds may qualify for federal tax credits under the Inflation Reduction Act (25C) — consult a qualified tax professional for current eligibility requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAHRI Certified; ETL Listed; ENERGY STAR (when matched with qualifying indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Goodman will furnish a new replacement outdoor unit (one time). Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626B3A*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower (MBVK12BP1X00AA):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties apply to owner-occupied residential installations only. Different terms apply to commercial and rental properties. Labor, refrigerant, freight, and other service costs are not covered. Complete warranty details are available at goodmanmfg.com.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884451725632,"sku":"GZV6SA3610-CAPEA3626B3-MBVK12BP1X00-215447183","price":5157.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/btnfthgytjtyjtyjed.jpg?v=1777798322"},{"product_id":"goodman-gzv6sa3610-capea3626c3-mbvk12bp1x00-215447183","title":"Goodman 3 Ton 16.6 SEER2 R-32 Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower | GZV6SA3610 + CAPEA3626C3 + MBVK12BP1X00 | 21\" Depth, Upflow\/Downflow Coil","description":"\u003cp\u003eThis Goodman 3-Ton Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower pairs the GZV6SA3610* variable-speed heat pump with the CAPEA3626C3 evaporator coil and MBVK12BP1X00 communicating modular blower. AHRI-certified (Certificate #215447183) at 16.6 SEER2 and 8.5 HSPF2, this configuration uses R-32 low-GWP refrigerant and provides efficient all-electric heating and cooling. The modular blower and coil design offers flexible installation options in both vertical and horizontal orientations.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump Condenser:\u003c\/strong\u003e Goodman GZV6SA3610* — 3-Ton variable-speed inverter-driven R-32 heat pump with swing compressor, EEV metering, and digitally commutated condenser fan motor. Sound power as low as 45 dBA in quiet mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil:\u003c\/strong\u003e Goodman CAPEA3626C3A* — 3-Ton cased Upflow\/Downflow all-aluminum evaporator coil with integrated EEV, factory-installed R-32 sensor, and thermoplastic drain pan with secondary drain connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower:\u003c\/strong\u003e Goodman MBVK12BP1X00AA — 1200-CFM variable-speed ECM communicating modular blower (17-1\/2\") with SmartFrame cabinet, integrated ComfortBridge technology, and built-in dehumidification feature. Compatible with R-32 refrigerant with integration kit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The two-piece coil-and-blower configuration offers installation flexibility, but the coil width must match the blower cabinet width for a proper seal. Mismatched widths create air bypass around the coil face, reducing system capacity and triggering low-superheat fault codes from the outdoor unit's EEV controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After mounting the coil on the blower, verify the drain pan rail alignment and apply foil-faced tape at the coil-to-blower junction seam. Pressure-test the completed assembly with a duct leakage tester — total air leakage should remain below 2% at 1.0\" w.c. per ASHRAE 193. This prevents efficiency loss and condensation issues that often surface 6-8 months after installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Verify the communicating connection between the MBVK blower, the evaporator coil's EEV, and the outdoor unit through the CoolCloud app. Confirm the blower is configured for the correct tonnage setting and that the EEV superheat is auto-controlled, with subcooling reading 15 +\/- 1 deg.F at the outdoor unit's service valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e The R-32 integration kit must be installed on the blower for R-32 compatibility. Verify the R-32 leak sensor on the coil is functional before sealing the access panel. In jurisdictions enforcing ASHRAE 15 or state-level A2L refrigerant handling requirements, ensure the installation meets maximum charge density limits for the occupied space.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Installation Flexibility:\u003c\/strong\u003e The separate coil and blower design allows each component to be positioned independently, accommodating tight mechanical closets, attics, and crawl spaces where a single-piece air handler may not fit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Seasonal Efficiency:\u003c\/strong\u003e 16.6 SEER2 cooling and 8.5 HSPF2 heating ratings maximize energy savings across both seasons, potentially qualifying for federal tax credits and utility rebates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The variable-speed outdoor compressor and communicating ECM blower motor work together to modulate airflow and capacity, delivering consistent temperatures and improved dehumidification at part-load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a 68% lower global warming potential than R-410A and offers higher volumetric cooling capacity, supporting the industry transition under the AIM Act phasedown schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating Integration:\u003c\/strong\u003e The MBVK blower's ComfortBridge technology communicates directly with the outdoor unit and compatible thermostat, enabling automated airflow configuration, tonnage matching, and diagnostic reporting through the CoolCloud app.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance (AHRI Certificate #215447183)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA3610*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @17°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 71 dBA (as low as 45 dBA in quiet mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e36-5\/8\" x 13-3\/4\" x 27-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e137 lbs \/ 151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e83 oz (factory charge for 15' line set)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CAPEA3626C3A*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e5\/16\" or 3\/8\" \/ 3\/4\" or 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e57 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eModular Blower — MBVK12BP1X00AA\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional (Vertical \/ Horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003eUp to 1200 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e17-1\/2\" x 21\" x 26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e4.9A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e67 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane) — A2L (mildly flammable) classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eEPA-certified technician required for refrigerant handling; R-32 requires A2L-rated recovery equipment and leak detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll-region sales designation (Region A); verify local A2L refrigerant installation codes and charge density limits per ASHRAE 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eHeat pump systems meeting efficiency thresholds may qualify for federal tax credits under the Inflation Reduction Act (25C) — consult a qualified tax professional for current eligibility requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAHRI Certified; ETL Listed; ENERGY STAR (when matched with qualifying indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Goodman will furnish a new replacement outdoor unit (one time). Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626C3A*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower (MBVK12BP1X00AA):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties apply to owner-occupied residential installations only. Different terms apply to commercial and rental properties. Labor, refrigerant, freight, and other service costs are not covered. Complete warranty details are available at goodmanmfg.com.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884451856704,"sku":"GZV6SA3610-CAPEA3626C3-MBVK12BP1X00-215447183","price":5183.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/btnfthgytjtyjtyjed.jpg?v=1777798322"},{"product_id":"goodman-gzv6sa3610-capea3626c3-mbvk16cp1x00-215447181","title":"Goodman 3 Ton 16.6 SEER2 R-32 Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower | GZV6SA3610 + CAPEA3626C3 + MBVK16CP1X00 | 21\" Depth, Upflow\/Downflow Coil","description":"\u003cp\u003eThis Goodman 3-Ton Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower pairs the GZV6SA3610* variable-speed heat pump with the CAPEA3626C3 evaporator coil and MBVK16CP1X00 communicating modular blower. AHRI-certified (Certificate #215447181) at 16.6 SEER2 and 8.5 HSPF2, this configuration uses R-32 low-GWP refrigerant and provides efficient all-electric heating and cooling. The modular blower and coil design offers flexible installation options in both vertical and horizontal orientations.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump Condenser:\u003c\/strong\u003e Goodman GZV6SA3610* — 3-Ton variable-speed inverter-driven R-32 heat pump with swing compressor, EEV metering, and digitally commutated condenser fan motor. Sound power as low as 45 dBA in quiet mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil:\u003c\/strong\u003e Goodman CAPEA3626C3A* — 3-Ton cased Upflow\/Downflow all-aluminum evaporator coil with integrated EEV, factory-installed R-32 sensor, and thermoplastic drain pan with secondary drain connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower:\u003c\/strong\u003e Goodman MBVK16CP1X00AA — 1600-CFM variable-speed ECM communicating modular blower (21\") with SmartFrame cabinet, integrated ComfortBridge technology, and built-in dehumidification feature. Compatible with R-32 refrigerant with integration kit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The two-piece coil-and-blower configuration offers installation flexibility, but the coil width must match the blower cabinet width for a proper seal. Mismatched widths create air bypass around the coil face, reducing system capacity and triggering low-superheat fault codes from the outdoor unit's EEV controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After mounting the coil on the blower, verify the drain pan rail alignment and apply foil-faced tape at the coil-to-blower junction seam. Pressure-test the completed assembly with a duct leakage tester — total air leakage should remain below 2% at 1.0\" w.c. per ASHRAE 193. This prevents efficiency loss and condensation issues that often surface 6-8 months after installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Verify the communicating connection between the MBVK blower, the evaporator coil's EEV, and the outdoor unit through the CoolCloud app. Confirm the blower is configured for the correct tonnage setting and that the EEV superheat is auto-controlled, with subcooling reading 15 +\/- 1 deg.F at the outdoor unit's service valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e The R-32 integration kit must be installed on the blower for R-32 compatibility. Verify the R-32 leak sensor on the coil is functional before sealing the access panel. In jurisdictions enforcing ASHRAE 15 or state-level A2L refrigerant handling requirements, ensure the installation meets maximum charge density limits for the occupied space.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Installation Flexibility:\u003c\/strong\u003e The separate coil and blower design allows each component to be positioned independently, accommodating tight mechanical closets, attics, and crawl spaces where a single-piece air handler may not fit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Seasonal Efficiency:\u003c\/strong\u003e 16.6 SEER2 cooling and 8.5 HSPF2 heating ratings maximize energy savings across both seasons, potentially qualifying for federal tax credits and utility rebates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The variable-speed outdoor compressor and communicating ECM blower motor work together to modulate airflow and capacity, delivering consistent temperatures and improved dehumidification at part-load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a 68% lower global warming potential than R-410A and offers higher volumetric cooling capacity, supporting the industry transition under the AIM Act phasedown schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating Integration:\u003c\/strong\u003e The MBVK blower's ComfortBridge technology communicates directly with the outdoor unit and compatible thermostat, enabling automated airflow configuration, tonnage matching, and diagnostic reporting through the CoolCloud app.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance (AHRI Certificate #215447181)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA3610*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @17°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 71 dBA (as low as 45 dBA in quiet mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e36-5\/8\" x 13-3\/4\" x 27-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e137 lbs \/ 151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e83 oz (factory charge for 15' line set)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CAPEA3626C3A*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e5\/16\" or 3\/8\" \/ 3\/4\" or 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e57 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eModular Blower — MBVK16CP1X00AA\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional (Vertical \/ Horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003eUp to 1600 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e3\/4 HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e6.5A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e80 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane) — A2L (mildly flammable) classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eEPA-certified technician required for refrigerant handling; R-32 requires A2L-rated recovery equipment and leak detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll-region sales designation (Region A); verify local A2L refrigerant installation codes and charge density limits per ASHRAE 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eHeat pump systems meeting efficiency thresholds may qualify for federal tax credits under the Inflation Reduction Act (25C) — consult a qualified tax professional for current eligibility requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAHRI Certified; ETL Listed; ENERGY STAR (when matched with qualifying indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Goodman will furnish a new replacement outdoor unit (one time). Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626C3A*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower (MBVK16CP1X00AA):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties apply to owner-occupied residential installations only. Different terms apply to commercial and rental properties. Labor, refrigerant, freight, and other service costs are not covered. Complete warranty details are available at goodmanmfg.com.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884451922240,"sku":"GZV6SA3610-CAPEA3626C3-MBVK16CP1X00-215447181","price":5259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/btnfthgytjtyjtyjed.jpg?v=1777798322"},{"product_id":"goodman-gzv6sa3610-capea3626d3-mbvk20dp1x00-215447615","title":"Goodman 3 Ton 16.6 SEER2 R-32 Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower | GZV6SA3610 + CAPEA3626D3 + MBVK20DP1X00 | 21\" Depth, Upflow\/Downflow Coil","description":"\u003cp\u003eThis Goodman 3-Ton Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower pairs the GZV6SA3610* variable-speed heat pump with the CAPEA3626D3 evaporator coil and MBVK20DP1X00 communicating modular blower. AHRI-certified (Certificate #215447615) at 16.6 SEER2 and 8.5 HSPF2, this configuration uses R-32 low-GWP refrigerant and provides efficient all-electric heating and cooling. The modular blower and coil design offers flexible installation options in both vertical and horizontal orientations.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump Condenser:\u003c\/strong\u003e Goodman GZV6SA3610* — 3-Ton variable-speed inverter-driven R-32 heat pump with swing compressor, EEV metering, and digitally commutated condenser fan motor. Sound power as low as 45 dBA in quiet mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil:\u003c\/strong\u003e Goodman CAPEA3626D3A* — 3-Ton cased Upflow\/Downflow all-aluminum evaporator coil with integrated EEV, factory-installed R-32 sensor, and thermoplastic drain pan with secondary drain connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower:\u003c\/strong\u003e Goodman MBVK20DP1X00AA — 2000-CFM variable-speed ECM communicating modular blower (24-1\/2\") with SmartFrame cabinet, integrated ComfortBridge technology, and built-in dehumidification feature. Compatible with R-32 refrigerant with integration kit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The two-piece coil-and-blower configuration offers installation flexibility, but the coil width must match the blower cabinet width for a proper seal. Mismatched widths create air bypass around the coil face, reducing system capacity and triggering low-superheat fault codes from the outdoor unit's EEV controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After mounting the coil on the blower, verify the drain pan rail alignment and apply foil-faced tape at the coil-to-blower junction seam. Pressure-test the completed assembly with a duct leakage tester — total air leakage should remain below 2% at 1.0\" w.c. per ASHRAE 193. This prevents efficiency loss and condensation issues that often surface 6-8 months after installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Verify the communicating connection between the MBVK blower, the evaporator coil's EEV, and the outdoor unit through the CoolCloud app. Confirm the blower is configured for the correct tonnage setting and that the EEV superheat is auto-controlled, with subcooling reading 15 +\/- 1 deg.F at the outdoor unit's service valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e The R-32 integration kit must be installed on the blower for R-32 compatibility. Verify the R-32 leak sensor on the coil is functional before sealing the access panel. In jurisdictions enforcing ASHRAE 15 or state-level A2L refrigerant handling requirements, ensure the installation meets maximum charge density limits for the occupied space.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Installation Flexibility:\u003c\/strong\u003e The separate coil and blower design allows each component to be positioned independently, accommodating tight mechanical closets, attics, and crawl spaces where a single-piece air handler may not fit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Seasonal Efficiency:\u003c\/strong\u003e 16.6 SEER2 cooling and 8.5 HSPF2 heating ratings maximize energy savings across both seasons, potentially qualifying for federal tax credits and utility rebates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The variable-speed outdoor compressor and communicating ECM blower motor work together to modulate airflow and capacity, delivering consistent temperatures and improved dehumidification at part-load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a 68% lower global warming potential than R-410A and offers higher volumetric cooling capacity, supporting the industry transition under the AIM Act phasedown schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating Integration:\u003c\/strong\u003e The MBVK blower's ComfortBridge technology communicates directly with the outdoor unit and compatible thermostat, enabling automated airflow configuration, tonnage matching, and diagnostic reporting through the CoolCloud app.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance (AHRI Certificate #215447615)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA3610*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @17°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 71 dBA (as low as 45 dBA in quiet mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e36-5\/8\" x 13-3\/4\" x 27-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e137 lbs \/ 151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e83 oz (factory charge for 15' line set)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CAPEA3626D3A*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24-1\/2\" x 21\" x 26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e5\/16\" or 3\/8\" \/ 3\/4\" or 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e62 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eModular Blower — MBVK20DP1X00AA\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional (Vertical \/ Horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003eUp to 2000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24-1\/2\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e3\/4 HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e6.5A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e86 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane) — A2L (mildly flammable) classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eEPA-certified technician required for refrigerant handling; R-32 requires A2L-rated recovery equipment and leak detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll-region sales designation (Region A); verify local A2L refrigerant installation codes and charge density limits per ASHRAE 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eHeat pump systems meeting efficiency thresholds may qualify for federal tax credits under the Inflation Reduction Act (25C) — consult a qualified tax professional for current eligibility requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAHRI Certified; ETL Listed; ENERGY STAR (when matched with qualifying indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Goodman will furnish a new replacement outdoor unit (one time). Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626D3A*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower (MBVK20DP1X00AA):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties apply to owner-occupied residential installations only. Different terms apply to commercial and rental properties. Labor, refrigerant, freight, and other service costs are not covered. Complete warranty details are available at goodmanmfg.com.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884452020544,"sku":"GZV6SA3610-CAPEA3626D3-MBVK20DP1X00-215447615","price":5311.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/btnfthgytjtyjtyjed.jpg?v=1777798322"},{"product_id":"goodman-gzv6sa3610-capea3626d3-mbvk16cp1x00-215447181","title":"Goodman 3 Ton 16.6 SEER2 R-32 Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower | GZV6SA3610 + CAPEA3626D3 + MBVK16CP1X00 | 21\" Depth, Upflow\/Downflow Coil","description":"\u003cp\u003eThis Goodman 3-Ton Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower pairs the GZV6SA3610* variable-speed heat pump with the CAPEA3626D3 evaporator coil and MBVK16CP1X00 communicating modular blower. AHRI-certified (Certificate #215447181) at 16.6 SEER2 and 8.5 HSPF2, this configuration uses R-32 low-GWP refrigerant and provides efficient all-electric heating and cooling. The modular blower and coil design offers flexible installation options in both vertical and horizontal orientations.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump Condenser:\u003c\/strong\u003e Goodman GZV6SA3610* — 3-Ton variable-speed inverter-driven R-32 heat pump with swing compressor, EEV metering, and digitally commutated condenser fan motor. Sound power as low as 45 dBA in quiet mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil:\u003c\/strong\u003e Goodman CAPEA3626D3A* — 3-Ton cased Upflow\/Downflow all-aluminum evaporator coil with integrated EEV, factory-installed R-32 sensor, and thermoplastic drain pan with secondary drain connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower:\u003c\/strong\u003e Goodman MBVK16CP1X00AA — 1600-CFM variable-speed ECM communicating modular blower (21\") with SmartFrame cabinet, integrated ComfortBridge technology, and built-in dehumidification feature. Compatible with R-32 refrigerant with integration kit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The two-piece coil-and-blower configuration offers installation flexibility, but the coil width must match the blower cabinet width for a proper seal. Mismatched widths create air bypass around the coil face, reducing system capacity and triggering low-superheat fault codes from the outdoor unit's EEV controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After mounting the coil on the blower, verify the drain pan rail alignment and apply foil-faced tape at the coil-to-blower junction seam. Pressure-test the completed assembly with a duct leakage tester — total air leakage should remain below 2% at 1.0\" w.c. per ASHRAE 193. This prevents efficiency loss and condensation issues that often surface 6-8 months after installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Verify the communicating connection between the MBVK blower, the evaporator coil's EEV, and the outdoor unit through the CoolCloud app. Confirm the blower is configured for the correct tonnage setting and that the EEV superheat is auto-controlled, with subcooling reading 15 +\/- 1 deg.F at the outdoor unit's service valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e The R-32 integration kit must be installed on the blower for R-32 compatibility. Verify the R-32 leak sensor on the coil is functional before sealing the access panel. In jurisdictions enforcing ASHRAE 15 or state-level A2L refrigerant handling requirements, ensure the installation meets maximum charge density limits for the occupied space.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Installation Flexibility:\u003c\/strong\u003e The separate coil and blower design allows each component to be positioned independently, accommodating tight mechanical closets, attics, and crawl spaces where a single-piece air handler may not fit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Seasonal Efficiency:\u003c\/strong\u003e 16.6 SEER2 cooling and 8.5 HSPF2 heating ratings maximize energy savings across both seasons, potentially qualifying for federal tax credits and utility rebates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The variable-speed outdoor compressor and communicating ECM blower motor work together to modulate airflow and capacity, delivering consistent temperatures and improved dehumidification at part-load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a 68% lower global warming potential than R-410A and offers higher volumetric cooling capacity, supporting the industry transition under the AIM Act phasedown schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating Integration:\u003c\/strong\u003e The MBVK blower's ComfortBridge technology communicates directly with the outdoor unit and compatible thermostat, enabling automated airflow configuration, tonnage matching, and diagnostic reporting through the CoolCloud app.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance (AHRI Certificate #215447181)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA3610*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @17°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 71 dBA (as low as 45 dBA in quiet mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e36-5\/8\" x 13-3\/4\" x 27-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e137 lbs \/ 151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e83 oz (factory charge for 15' line set)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CAPEA3626D3A*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24-1\/2\" x 21\" x 26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e5\/16\" or 3\/8\" \/ 3\/4\" or 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e62 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eModular Blower — MBVK16CP1X00AA\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional (Vertical \/ Horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003eUp to 1600 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e3\/4 HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e6.5A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e80 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane) — A2L (mildly flammable) classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eEPA-certified technician required for refrigerant handling; R-32 requires A2L-rated recovery equipment and leak detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll-region sales designation (Region A); verify local A2L refrigerant installation codes and charge density limits per ASHRAE 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eHeat pump systems meeting efficiency thresholds may qualify for federal tax credits under the Inflation Reduction Act (25C) — consult a qualified tax professional for current eligibility requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAHRI Certified; ETL Listed; ENERGY STAR (when matched with qualifying indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Goodman will furnish a new replacement outdoor unit (one time). Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626D3A*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower (MBVK16CP1X00AA):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties apply to owner-occupied residential installations only. Different terms apply to commercial and rental properties. Labor, refrigerant, freight, and other service costs are not covered. Complete warranty details are available at goodmanmfg.com.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884452086080,"sku":"GZV6SA3610-CAPEA3626D3-MBVK16CP1X00-215447181","price":5268.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/btnfthgytjtyjtyjed.jpg?v=1777798322"},{"product_id":"goodman-gzv6sa3610-chpea3626b3-mbvk12bp1x00-215447182","title":"Goodman 3 Ton 16.6 SEER2 R-32 Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower | GZV6SA3610 + CHPEA3626B3 + MBVK12BP1X00 | 26\" Width, Horizontal Coil","description":"\u003cp\u003eThis Goodman 3-Ton Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower pairs the GZV6SA3610* variable-speed heat pump with the CHPEA3626B3 evaporator coil and MBVK12BP1X00 communicating modular blower. AHRI-certified (Certificate #215447182) at 16.6 SEER2 and 8.5 HSPF2, this configuration uses R-32 low-GWP refrigerant and provides efficient all-electric heating and cooling. The modular blower and coil design offers flexible installation options in both vertical and horizontal orientations.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump Condenser:\u003c\/strong\u003e Goodman GZV6SA3610* — 3-Ton variable-speed inverter-driven R-32 heat pump with swing compressor, EEV metering, and digitally commutated condenser fan motor. Sound power as low as 45 dBA in quiet mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil:\u003c\/strong\u003e Goodman CHPEA3626B3A* — 3-Ton cased Horizontal all-aluminum evaporator coil with integrated EEV, factory-installed R-32 sensor, and thermoplastic drain pan with secondary drain connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower:\u003c\/strong\u003e Goodman MBVK12BP1X00AA — 1200-CFM variable-speed ECM communicating modular blower (17-1\/2\") with SmartFrame cabinet, integrated ComfortBridge technology, and built-in dehumidification feature. Compatible with R-32 refrigerant with integration kit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The two-piece coil-and-blower configuration offers installation flexibility, but the coil width must match the blower cabinet width for a proper seal. Mismatched widths create air bypass around the coil face, reducing system capacity and triggering low-superheat fault codes from the outdoor unit's EEV controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After mounting the coil on the blower, verify the drain pan rail alignment and apply foil-faced tape at the coil-to-blower junction seam. Pressure-test the completed assembly with a duct leakage tester — total air leakage should remain below 2% at 1.0\" w.c. per ASHRAE 193. This prevents efficiency loss and condensation issues that often surface 6-8 months after installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Verify the communicating connection between the MBVK blower, the evaporator coil's EEV, and the outdoor unit through the CoolCloud app. Confirm the blower is configured for the correct tonnage setting and that the EEV superheat is auto-controlled, with subcooling reading 15 +\/- 1 deg.F at the outdoor unit's service valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e The R-32 integration kit must be installed on the blower for R-32 compatibility. Verify the R-32 leak sensor on the coil is functional before sealing the access panel. In jurisdictions enforcing ASHRAE 15 or state-level A2L refrigerant handling requirements, ensure the installation meets maximum charge density limits for the occupied space.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Installation Flexibility:\u003c\/strong\u003e The separate coil and blower design allows each component to be positioned independently, accommodating tight mechanical closets, attics, and crawl spaces where a single-piece air handler may not fit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Seasonal Efficiency:\u003c\/strong\u003e 16.6 SEER2 cooling and 8.5 HSPF2 heating ratings maximize energy savings across both seasons, potentially qualifying for federal tax credits and utility rebates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The variable-speed outdoor compressor and communicating ECM blower motor work together to modulate airflow and capacity, delivering consistent temperatures and improved dehumidification at part-load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a 68% lower global warming potential than R-410A and offers higher volumetric cooling capacity, supporting the industry transition under the AIM Act phasedown schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating Integration:\u003c\/strong\u003e The MBVK blower's ComfortBridge technology communicates directly with the outdoor unit and compatible thermostat, enabling automated airflow configuration, tonnage matching, and diagnostic reporting through the CoolCloud app.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance (AHRI Certificate #215447182)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA3610*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @17°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 71 dBA (as low as 45 dBA in quiet mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e36-5\/8\" x 13-3\/4\" x 27-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e137 lbs \/ 151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e83 oz (factory charge for 15' line set)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CHPEA3626B3A*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e26\" x 21\" x 17-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e5\/16\" or 3\/8\" \/ 3\/4\" or 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e68 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eModular Blower — MBVK12BP1X00AA\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional (Vertical \/ Horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003eUp to 1200 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e17-1\/2\" x 21\" x 26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e4.9A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e67 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane) — A2L (mildly flammable) classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eEPA-certified technician required for refrigerant handling; R-32 requires A2L-rated recovery equipment and leak detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll-region sales designation (Region A); verify local A2L refrigerant installation codes and charge density limits per ASHRAE 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eHeat pump systems meeting efficiency thresholds may qualify for federal tax credits under the Inflation Reduction Act (25C) — consult a qualified tax professional for current eligibility requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAHRI Certified; ETL Listed; ENERGY STAR (when matched with qualifying indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Goodman will furnish a new replacement outdoor unit (one time). Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA3626B3A*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower (MBVK12BP1X00AA):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties apply to owner-occupied residential installations only. Different terms apply to commercial and rental properties. Labor, refrigerant, freight, and other service costs are not covered. Complete warranty details are available at goodmanmfg.com.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884452151616,"sku":"GZV6SA3610-CHPEA3626B3-MBVK12BP1X00-215447182","price":5040.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/btnfthgytjtyjtyjed.jpg?v=1777798322"},{"product_id":"goodman-gzv6sa3610-chpea3626c3-mbvk12bp1x00-215447182","title":"Goodman 3 Ton 16.6 SEER2 R-32 Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower | GZV6SA3610 + CHPEA3626C3 + MBVK12BP1X00 | 26\" Width, Horizontal Coil","description":"\u003cp\u003eThis Goodman 3-Ton Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower pairs the GZV6SA3610* variable-speed heat pump with the CHPEA3626C3 evaporator coil and MBVK12BP1X00 communicating modular blower. AHRI-certified (Certificate #215447182) at 16.6 SEER2 and 8.5 HSPF2, this configuration uses R-32 low-GWP refrigerant and provides efficient all-electric heating and cooling. The modular blower and coil design offers flexible installation options in both vertical and horizontal orientations.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump Condenser:\u003c\/strong\u003e Goodman GZV6SA3610* — 3-Ton variable-speed inverter-driven R-32 heat pump with swing compressor, EEV metering, and digitally commutated condenser fan motor. Sound power as low as 45 dBA in quiet mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil:\u003c\/strong\u003e Goodman CHPEA3626C3A* — 3-Ton cased Horizontal all-aluminum evaporator coil with integrated EEV, factory-installed R-32 sensor, and thermoplastic drain pan with secondary drain connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower:\u003c\/strong\u003e Goodman MBVK12BP1X00AA — 1200-CFM variable-speed ECM communicating modular blower (17-1\/2\") with SmartFrame cabinet, integrated ComfortBridge technology, and built-in dehumidification feature. Compatible with R-32 refrigerant with integration kit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The two-piece coil-and-blower configuration offers installation flexibility, but the coil width must match the blower cabinet width for a proper seal. Mismatched widths create air bypass around the coil face, reducing system capacity and triggering low-superheat fault codes from the outdoor unit's EEV controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After mounting the coil on the blower, verify the drain pan rail alignment and apply foil-faced tape at the coil-to-blower junction seam. Pressure-test the completed assembly with a duct leakage tester — total air leakage should remain below 2% at 1.0\" w.c. per ASHRAE 193. This prevents efficiency loss and condensation issues that often surface 6-8 months after installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Verify the communicating connection between the MBVK blower, the evaporator coil's EEV, and the outdoor unit through the CoolCloud app. Confirm the blower is configured for the correct tonnage setting and that the EEV superheat is auto-controlled, with subcooling reading 15 +\/- 1 deg.F at the outdoor unit's service valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e The R-32 integration kit must be installed on the blower for R-32 compatibility. Verify the R-32 leak sensor on the coil is functional before sealing the access panel. In jurisdictions enforcing ASHRAE 15 or state-level A2L refrigerant handling requirements, ensure the installation meets maximum charge density limits for the occupied space.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Installation Flexibility:\u003c\/strong\u003e The separate coil and blower design allows each component to be positioned independently, accommodating tight mechanical closets, attics, and crawl spaces where a single-piece air handler may not fit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Seasonal Efficiency:\u003c\/strong\u003e 16.6 SEER2 cooling and 8.5 HSPF2 heating ratings maximize energy savings across both seasons, potentially qualifying for federal tax credits and utility rebates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The variable-speed outdoor compressor and communicating ECM blower motor work together to modulate airflow and capacity, delivering consistent temperatures and improved dehumidification at part-load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a 68% lower global warming potential than R-410A and offers higher volumetric cooling capacity, supporting the industry transition under the AIM Act phasedown schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating Integration:\u003c\/strong\u003e The MBVK blower's ComfortBridge technology communicates directly with the outdoor unit and compatible thermostat, enabling automated airflow configuration, tonnage matching, and diagnostic reporting through the CoolCloud app.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance (AHRI Certificate #215447182)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA3610*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @17°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 71 dBA (as low as 45 dBA in quiet mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e36-5\/8\" x 13-3\/4\" x 27-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e137 lbs \/ 151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e83 oz (factory charge for 15' line set)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CHPEA3626C3A*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e26\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e5\/16\" or 3\/8\" \/ 3\/4\" or 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e70 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eModular Blower — MBVK12BP1X00AA\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional (Vertical \/ Horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003eUp to 1200 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e17-1\/2\" x 21\" x 26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e4.9A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e67 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane) — A2L (mildly flammable) classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eEPA-certified technician required for refrigerant handling; R-32 requires A2L-rated recovery equipment and leak detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll-region sales designation (Region A); verify local A2L refrigerant installation codes and charge density limits per ASHRAE 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eHeat pump systems meeting efficiency thresholds may qualify for federal tax credits under the Inflation Reduction Act (25C) — consult a qualified tax professional for current eligibility requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAHRI Certified; ETL Listed; ENERGY STAR (when matched with qualifying indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Goodman will furnish a new replacement outdoor unit (one time). Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA3626C3A*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower (MBVK12BP1X00AA):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties apply to owner-occupied residential installations only. Different terms apply to commercial and rental properties. Labor, refrigerant, freight, and other service costs are not covered. Complete warranty details are available at goodmanmfg.com.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884452249920,"sku":"GZV6SA3610-CHPEA3626C3-MBVK12BP1X00-215447182","price":5076.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/btnfthgytjtyjtyjed.jpg?v=1777798322"},{"product_id":"goodman-gzv6sa3610-chpea3626c3-mbvk16cp1x00-215447180","title":"Goodman 3 Ton 16.6 SEER2 R-32 Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower | GZV6SA3610 + CHPEA3626C3 + MBVK16CP1X00 | 26\" Width, Horizontal Coil","description":"\u003cp\u003eThis Goodman 3-Ton Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower pairs the GZV6SA3610* variable-speed heat pump with the CHPEA3626C3 evaporator coil and MBVK16CP1X00 communicating modular blower. AHRI-certified (Certificate #215447180) at 16.6 SEER2 and 8.5 HSPF2, this configuration uses R-32 low-GWP refrigerant and provides efficient all-electric heating and cooling. The modular blower and coil design offers flexible installation options in both vertical and horizontal orientations.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump Condenser:\u003c\/strong\u003e Goodman GZV6SA3610* — 3-Ton variable-speed inverter-driven R-32 heat pump with swing compressor, EEV metering, and digitally commutated condenser fan motor. Sound power as low as 45 dBA in quiet mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil:\u003c\/strong\u003e Goodman CHPEA3626C3A* — 3-Ton cased Horizontal all-aluminum evaporator coil with integrated EEV, factory-installed R-32 sensor, and thermoplastic drain pan with secondary drain connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower:\u003c\/strong\u003e Goodman MBVK16CP1X00AA — 1600-CFM variable-speed ECM communicating modular blower (21\") with SmartFrame cabinet, integrated ComfortBridge technology, and built-in dehumidification feature. Compatible with R-32 refrigerant with integration kit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The two-piece coil-and-blower configuration offers installation flexibility, but the coil width must match the blower cabinet width for a proper seal. Mismatched widths create air bypass around the coil face, reducing system capacity and triggering low-superheat fault codes from the outdoor unit's EEV controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After mounting the coil on the blower, verify the drain pan rail alignment and apply foil-faced tape at the coil-to-blower junction seam. Pressure-test the completed assembly with a duct leakage tester — total air leakage should remain below 2% at 1.0\" w.c. per ASHRAE 193. This prevents efficiency loss and condensation issues that often surface 6-8 months after installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Verify the communicating connection between the MBVK blower, the evaporator coil's EEV, and the outdoor unit through the CoolCloud app. Confirm the blower is configured for the correct tonnage setting and that the EEV superheat is auto-controlled, with subcooling reading 15 +\/- 1 deg.F at the outdoor unit's service valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e The R-32 integration kit must be installed on the blower for R-32 compatibility. Verify the R-32 leak sensor on the coil is functional before sealing the access panel. In jurisdictions enforcing ASHRAE 15 or state-level A2L refrigerant handling requirements, ensure the installation meets maximum charge density limits for the occupied space.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Installation Flexibility:\u003c\/strong\u003e The separate coil and blower design allows each component to be positioned independently, accommodating tight mechanical closets, attics, and crawl spaces where a single-piece air handler may not fit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Seasonal Efficiency:\u003c\/strong\u003e 16.6 SEER2 cooling and 8.5 HSPF2 heating ratings maximize energy savings across both seasons, potentially qualifying for federal tax credits and utility rebates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The variable-speed outdoor compressor and communicating ECM blower motor work together to modulate airflow and capacity, delivering consistent temperatures and improved dehumidification at part-load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a 68% lower global warming potential than R-410A and offers higher volumetric cooling capacity, supporting the industry transition under the AIM Act phasedown schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating Integration:\u003c\/strong\u003e The MBVK blower's ComfortBridge technology communicates directly with the outdoor unit and compatible thermostat, enabling automated airflow configuration, tonnage matching, and diagnostic reporting through the CoolCloud app.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance (AHRI Certificate #215447180)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA3610*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @17°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 71 dBA (as low as 45 dBA in quiet mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e36-5\/8\" x 13-3\/4\" x 27-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e137 lbs \/ 151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e83 oz (factory charge for 15' line set)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CHPEA3626C3A*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e26\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e5\/16\" or 3\/8\" \/ 3\/4\" or 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e70 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eModular Blower — MBVK16CP1X00AA\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional (Vertical \/ Horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003eUp to 1600 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e3\/4 HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e6.5A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e80 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane) — A2L (mildly flammable) classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eEPA-certified technician required for refrigerant handling; R-32 requires A2L-rated recovery equipment and leak detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll-region sales designation (Region A); verify local A2L refrigerant installation codes and charge density limits per ASHRAE 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eHeat pump systems meeting efficiency thresholds may qualify for federal tax credits under the Inflation Reduction Act (25C) — consult a qualified tax professional for current eligibility requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAHRI Certified; ETL Listed; ENERGY STAR (when matched with qualifying indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Goodman will furnish a new replacement outdoor unit (one time). Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA3626C3A*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower (MBVK16CP1X00AA):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties apply to owner-occupied residential installations only. Different terms apply to commercial and rental properties. Labor, refrigerant, freight, and other service costs are not covered. Complete warranty details are available at goodmanmfg.com.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884452315456,"sku":"GZV6SA3610-CHPEA3626C3-MBVK16CP1X00-215447180","price":5152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/btnfthgytjtyjtyjed.jpg?v=1777798322"}],"url":"https:\/\/minisplitsystemsdirect.com\/collections\/goodman-3-ton-systems-16-6-seer2.oembed","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}