{"title":"Goodman, 4 Ton Systems, 17.5 SEER2","description":null,"products":[{"product_id":"goodman-gzv7sa4810-4-ton-17-5-seer2-high-efficiency-variable-speed-inverter-heat-pump-side-discharge-condenser-r-32","title":"Goodman GZV7SA4810 4 Ton 17.5 SEER2 High-Efficiency Variable-Speed Inverter Heat Pump Side Discharge Condenser - R-32","description":"\u003ch3\u003e\u003cstrong\u003eGoodman GZV7SA4810 4 Ton 17.5 SEER2 High-Efficiency Variable-Speed Inverter Heat Pump Side Discharge Condenser - R-32\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMaximize comfort and efficiency with the \u003cstrong\u003eGoodman GZV7SA4810 4 Ton 17.5 SEER2 High-Efficiency Variable-Speed Inverter Heat Pump Side Discharge Condenser - R-32\u003c\/strong\u003e. Engineered for superior performance, this split system heat pump condenser delivers up to 17.5 SEER2 cooling efficiency and 8.8 HSPF2 heating efficiency. Its variable-speed inverter compressor optimizes energy use, offering quieter operation (as low as 45 dB) and enhanced temperature control. Built with high-density sound insulation, a digitally commutated fan motor, and diagnostic LED display alerts, it’s also compatible with Goodman’s GTST communicating thermostat systems for simplified connectivity. Backed by a 10-year unit replacement limited warranty and 10-year parts limited warranty when registered, the GZV7S SD is ideal for homeowners seeking a dependable, high-efficiency side discharge heat pump solution.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eQuick Facts:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGoodman SD (Side Discharge) High-Efficiency\u003c\/li\u003e\n\u003cli\u003eCommunicating, Variable-Speed, Inverter Driven\u003c\/li\u003e\n\u003cli\u003eR-32 Split System Heat Pump\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eStandard Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVariable-speed swing compressors\u003c\/li\u003e\n\u003cli\u003eStrong heating capacity\u003c\/li\u003e\n\u003cli\u003eQuiet digitally commutated fan motor\u003c\/li\u003e\n\u003cli\u003eHigh-density compressor sound blanket\u003c\/li\u003e\n\u003cli\u003eCompatible with Goodman GTST connected thermostat and other Goodman communicating equipment\u003c\/li\u003e\n\u003cli\u003eProprietary control algorithmic logic\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIn communicating mode, only two lowvoltage wires to outdoor unit required\u003c\/li\u003e\n\u003cli\u003eDiagnostic indicator lights, seven-segment LED display, and fault code storage\u003c\/li\u003e\n\u003cli\u003ePropietary Inside intelligence for diagnostics\u003c\/li\u003e\n\u003cli\u003eQuiet-mode - provides enhanced acoustical comfort, up to 3 different sound levels (as low as 45dBA)\u003c\/li\u003e\n\u003cli\u003eField-selectable boost mode increases compressor speed during unusually high loads\u003c\/li\u003e\n\u003cli\u003eField-installed bi-flow filter drier\u003c\/li\u003e\n\u003cli\u003eCoil and ambient temperature sensors\u003c\/li\u003e\n\u003cli\u003eSuction pressure transducer\u003c\/li\u003e\n\u003cli\u003eSweat connection service valves with easy access to gauge ports\u003c\/li\u003e\n\u003cli\u003eAHRI Certified; ETL Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCabinet Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy-gauge galvanized steel cabinet with grille-style sound control side design\u003c\/li\u003e\n\u003cli\u003eCustom Ivory white powder-paint finish\u003c\/li\u003e\n\u003cli\u003eHigh corrosion (ZAM®), unpainted steel bottom frame and legs\u003c\/li\u003e\n\u003cli\u003e500-hour salt-spray tested\u003c\/li\u003e\n\u003cli\u003eWire fan discharge grille\u003c\/li\u003e\n\u003cli\u003eTop and side maintenance access\u003c\/li\u003e\n\u003cli\u003eWhen properly anchored, meets the 2023 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10-Year Unit Replacement Limited Warranty\u003c\/li\u003e\n\u003cli\u003e10-Year Parts Limited Warranty\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSee\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/pwgachpmtsdb.pdf?v=1758718104\"\u003e Full Warranty Details\u003c\/a\u003e here for complete warranty information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGoodman GZV7SA4810 4 Ton 17.5 SEER2 High-Efficiency Variable-Speed Inverter Heat Pump Side Discharge Condenser - R-32 Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 105.41%; border-collapse: collapse; height: 1351.72px;\" width=\"100%\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2998%; height: 19.5938px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 60.8131%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2998%; height: 19.5938px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 60.8131%; height: 19.5938px;\"\u003e\u003cstrong\u003eGZV7SA4810\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.2998%; height: 39.1875px;\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"width: 60.8131%; height: 39.1875px;\"\u003e\u003cstrong\u003eR-32\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 106.781px;\"\u003e\n\u003ctd style=\"width: 39.2998%; height: 106.781px;\"\u003eCapacities (AHRI Rated)\u003c\/td\u003e\n\u003ctd style=\"width: 60.8131%; height: 106.781px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMax. Cooling (BTU\/h)-95F\u003c\/strong\u003e: 46,500\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMax. Heating (BTU\/h)-47F\u003c\/strong\u003e: 47,500\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMax. Heating (BTU\/h)-5F\u003c\/strong\u003e: 33,600\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 71.1875px;\"\u003e\n\u003ctd style=\"height: 71.1875px; width: 39.2998%;\"\u003eAmbient Operation Range\u003c\/td\u003e\n\u003ctd style=\"height: 71.1875px; width: 60.8131%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCooling (°FDB(°CDB))\u003c\/strong\u003e: 0 to 115 (-17.8 to 46.1)²\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHeating (°FDB(°CDB))\u003c\/strong\u003e: 10 to 70 (-23.3 to 21.1)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px; width: 39.2998%;\"\u003eCompressor\u003c\/td\u003e\n\u003ctd style=\"height: 10px; width: 60.8131%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Swing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"height: 35.5938px; width: 39.2998%;\"\u003eCondenser Fan Motor\u003c\/td\u003e\n\u003ctd style=\"height: 35.5938px; width: 60.8131%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eHorsepower\u003c\/strong\u003e: 0.36\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 343.531px;\"\u003e\n\u003ctd style=\"height: 343.531px; width: 39.2998%;\"\u003eRefrigeration System\u003c\/td\u003e\n\u003ctd style=\"height: 343.531px; width: 60.8131%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eRefrigerant Line Size¹\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin: 0 0 8px 18px; padding: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Line Size (“O.D.)\u003c\/strong\u003e: 3\/8\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuction Line Size (“O.D.)\u003c\/strong\u003e: 1-1\/8\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRefrigerant Connection Size\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin: 0 0 8px 18px; padding: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Valve Size (“O.D.)\u003c\/strong\u003e: 3\/8\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuction Valve Size (“O.D.)\u003c\/strong\u003e: 7\/8\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eValve Connection Type\u003c\/strong\u003e: Front and Back Sealing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRefrigerant Charge (oz.)\u003c\/strong\u003e: 118\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Device\u003c\/strong\u003e: EEV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuperheat at Service Valve\u003c\/strong\u003e: Auto-control\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubcooling at Service Valve\u003c\/strong\u003e: 9±1°F\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 213.562px;\"\u003e\n\u003ctd style=\"height: 213.562px; width: 39.2998%;\"\u003eElectrical Data\u003c\/td\u003e\n\u003ctd style=\"height: 213.562px; width: 60.8131%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage \/ Phase (60 Hz)\u003c\/strong\u003e: 208-230\/1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFan \/ Compressor Inverter Drive Input\u003c\/strong\u003e: 30\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Circuit Ampacity²\u003c\/strong\u003e: 37.5\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMax. Overcurrent Protection³\u003c\/strong\u003e: 40\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMin\/Max Volts\u003c\/strong\u003e: 197\/253\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Conduit Size\u003c\/strong\u003e: 1\/2\" or 3\/4\"\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.2998%; height: 35.5938px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"height: 35.5938px; width: 60.8131%;\"\u003e\n\u003cp\u003e37\" x 12-5\/8\" x 39\" (W x D x H)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 145.969px;\"\u003e\n\u003ctd style=\"height: 145.969px; width: 39.2998%;\"\u003eGeneral Specs\u003c\/td\u003e\n\u003ctd style=\"height: 145.969px; width: 60.8131%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEquipment Weight (lbs)\u003c\/strong\u003e: 179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShip Weight (lbs)\u003c\/strong\u003e: 198\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Star Certified\u003c\/strong\u003e: Energy Star Certified with Cold Climate Designation\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eSound Level\u003c\/strong\u003e: 45 - 73 (dBA)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 126.375px;\"\u003e\n\u003ctd style=\"height: 126.375px; width: 39.2998%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"height: 126.375px; width: 60.8131%;\"\u003e\n\u003cp\u003e10-Year Unit Replacement Limited Warranty\u003c\/p\u003e\n\u003cp\u003e10-Year Parts Limited Warranty\u003c\/p\u003e\n\u003cp\u003eSee \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/pwgachpmtsdb.pdf?v=1758718104\"\u003eFull Warranty Details\u003c\/a\u003e here for complete warranty information\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 145.562px;\"\u003e\n\u003ctd style=\"height: 145.562px; width: 39.2998%;\"\u003eResources\u003c\/td\u003e\n\u003ctd style=\"height: 145.562px; width: 60.8131%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/AG-TP-110.pdf?v=1758718977\"\u003eApplication Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/IM-3P761829-3B_EM23A026A_24071_compressed.pdf?v=1758718904\"\u003eInstallation Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/ss-gzv7s-r32.pdf?v=1758718046\"\u003eSpecifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/PM-RP-G4351.pdf?v=1758899583\"\u003eParts Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/SM-SiUS612414E_compressed_2.pdf?v=1758899738\"\u003eService Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/pwgachpmtsdb.pdf?v=1758718104\"\u003eWarranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.2998%; height: 39.1875px;\"\u003eProposition 65 Label\u003c\/td\u003e\n\u003ctd style=\"width: 60.8131%; height: 39.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51082107814208,"sku":"GZV7SA4810","price":4481.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Goodman-GZV7SA3610-3-Ton-17-5-SEER2-High-Efficiency-Variable-Speed-Inverter-Heat-Pump-Side-Discharge-Condenser-R32-GZV7SA3610-Mini-Split-Systems-Direct-41115933016384.jpg?v=1775132667"},{"product_id":"gzv9sa4810-capea6030d3-gmvm971205dn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GMVM971205DN | Communicating | 24½\" Upflow\/Downflow Coil | 120,000 BTU Upflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GMVM971205DN modulating gas furnace (97% AFUE, 120,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989230. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM971205DN\u003c\/strong\u003e — Goodman 120,000 BTU 97% AFUE Modulating Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Modulating gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 97% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GMVM971205DN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e120,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eModulating \/ Modulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets 16+ SEER2 \/ 9+ HSPF2 and furnace meets 97%+ AFUE thresholds. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM971205DN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657833283904,"sku":"GZV9SA4810-CAPEA6030D3-GMVM971205DN","price":11063.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030d3-gdvt961005cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GDVT961005CN | 24½\" Upflow\/Downflow Coil | 100,000 BTU Downflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GDVT961005CN two-stage gas furnace (96% AFUE, 100,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989214. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT961005CN\u003c\/strong\u003e — Goodman 100,000 BTU 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace. Downflow\/Horizontal configuration, Two-Stage gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GDVT961005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage \/ Two-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT961005CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657833513280,"sku":"GZV9SA4810-CAPEA6030D3-GDVT961005CN","price":10853.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/NFGNFGNFGNd.jpg?v=1777341191"},{"product_id":"gzv9sa4810-capea6030d3-grvm971205dn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GRVM971205DN | 24½\" Upflow\/Downflow Coil | 120,000 BTU Upflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GRVM971205DN modulating gas furnace (97% AFUE, 120,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989230. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM971205DN\u003c\/strong\u003e — Goodman 120,000 BTU 97% AFUE Modulating Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Modulating gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 97% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GRVM971205DN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e120,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eModulating \/ Modulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets 16+ SEER2 \/ 9+ HSPF2 and furnace meets 97%+ AFUE thresholds. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM971205DN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657833873728,"sku":"GZV9SA4810-CAPEA6030D3-GRVM971205DN","price":11396.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030d3-grvt961205dn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GRVT961205DN | 24½\" Upflow\/Downflow Coil | 120,000 BTU Downflow Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GRVT961205DN two-stage gas furnace (96% AFUE, 120,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989210. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961205DN\u003c\/strong\u003e — Goodman 120,000 BTU 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace. Downflow configuration, Two-Stage gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GRVT961205DN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e120,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage \/ Two-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961205DN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657833972032,"sku":"GZV9SA4810-CAPEA6030D3-GRVT961205DN","price":10903.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030d3-gmvs960805cu","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GMVS960805CU | Communicating | 24½\" Upflow\/Downflow Coil | 80,000 BTU Upflow\/Horizontal Single-Stage Variable-Speed ECM Ultra Low NOx Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GMVS960805CU single-stage gas furnace (96% AFUE, 80,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989226. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVS960805CU\u003c\/strong\u003e — Goodman 80,000 BTU 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Single-Stage gas valve, Ultra Low NOx. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989226\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GMVS960805CU\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage \/ Single-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eUltra Low NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVS960805CU (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657834135872,"sku":"GZV9SA4810-CAPEA6030D3-GMVS960805CU","price":11212.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030d3-gcvm970804cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GCVM970804CN | Communicating | 24½\" Upflow\/Downflow Coil | 80,000 BTU Downflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GCVM970804CN modulating gas furnace (97% AFUE, 80,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989234. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU 97% AFUE Modulating Variable-Speed ECM Gas Furnace. Downflow\/Horizontal configuration, Modulating gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 97% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GCVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eModulating \/ Modulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets 16+ SEER2 \/ 9+ HSPF2 and furnace meets 97%+ AFUE thresholds. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM970804CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657834168640,"sku":"GZV9SA4810-CAPEA6030D3-GCVM970804CN","price":10794.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Untitngnghnghn.jpg?v=1777796556"},{"product_id":"gzv9sa4810-capea6030c3-gmvm970804cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030C3 + GMVM970804CN | Communicating | 21\" Upflow\/Downflow Coil | 80,000 BTU Upflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GMVM970804CN modulating gas furnace (97% AFUE, 80,000 BTU) and a CAPEA6030C3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989234. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 21\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU 97% AFUE Modulating Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Modulating gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 97% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GMVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eModulating \/ Modulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets 16+ SEER2 \/ 9+ HSPF2 and furnace meets 97%+ AFUE thresholds. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM970804CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657834266944,"sku":"GZV9SA4810-CAPEA6030C3-GMVM970804CN","price":10556.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030c3-gcvm970804cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030C3 + GCVM970804CN | Communicating | 21\" Upflow\/Downflow Coil | 80,000 BTU Downflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GCVM970804CN modulating gas furnace (97% AFUE, 80,000 BTU) and a CAPEA6030C3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989234. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 21\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU 97% AFUE Modulating Variable-Speed ECM Gas Furnace. Downflow\/Horizontal configuration, Modulating gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 97% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GCVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eModulating \/ Modulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets 16+ SEER2 \/ 9+ HSPF2 and furnace meets 97%+ AFUE thresholds. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM970804CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657834365248,"sku":"GZV9SA4810-CAPEA6030C3-GCVM970804CN","price":10784.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Untitngnghnghn.jpg?v=1777796556"},{"product_id":"gzv9sa4810-capea6030d3-grvt961005dn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GRVT961005DN | 24½\" Upflow\/Downflow Coil | 100,000 BTU Downflow Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GRVT961005DN two-stage gas furnace (96% AFUE, 100,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989212. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961005DN\u003c\/strong\u003e — Goodman 100,000 BTU 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace. Downflow configuration, Two-Stage gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GRVT961005DN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage \/ Two-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961005DN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657834430784,"sku":"GZV9SA4810-CAPEA6030D3-GRVT961005DN","price":10875.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030d3-grvt961005cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GRVT961005CN | 24½\" Upflow\/Downflow Coil | 100,000 BTU Downflow Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GRVT961005CN two-stage gas furnace (96% AFUE, 100,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989214. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961005CN\u003c\/strong\u003e — Goodman 100,000 BTU 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace. Downflow configuration, Two-Stage gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GRVT961005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage \/ Two-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961005CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657834496320,"sku":"GZV9SA4810-CAPEA6030D3-GRVT961005CN","price":10764.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030d3-grvm970804cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GRVM970804CN | 24½\" Upflow\/Downflow Coil | 80,000 BTU Upflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GRVM970804CN modulating gas furnace (97% AFUE, 80,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989234. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU 97% AFUE Modulating Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Modulating gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 97% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GRVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eModulating \/ Modulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets 16+ SEER2 \/ 9+ HSPF2 and furnace meets 97%+ AFUE thresholds. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM970804CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657834561856,"sku":"GZV9SA4810-CAPEA6030D3-GRVM970804CN","price":10851.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030c3-gmvs960805cu","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030C3 + GMVS960805CU | Communicating | 21\" Upflow\/Downflow Coil | 80,000 BTU Upflow\/Horizontal Single-Stage Variable-Speed ECM Ultra Low NOx Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GMVS960805CU single-stage gas furnace (96% AFUE, 80,000 BTU) and a CAPEA6030C3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989226. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 21\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVS960805CU\u003c\/strong\u003e — Goodman 80,000 BTU 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Single-Stage gas valve, Ultra Low NOx. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989226\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GMVS960805CU\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage \/ Single-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eUltra Low NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVS960805CU (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657834856768,"sku":"GZV9SA4810-CAPEA6030C3-GMVS960805CU","price":11202.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030d3-gmvm970804cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GMVM970804CN | Communicating | 24½\" Upflow\/Downflow Coil | 80,000 BTU Upflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GMVM970804CN modulating gas furnace (97% AFUE, 80,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989234. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU 97% AFUE Modulating Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Modulating gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 97% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GMVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eModulating \/ Modulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets 16+ SEER2 \/ 9+ HSPF2 and furnace meets 97%+ AFUE thresholds. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM970804CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657834889536,"sku":"GZV9SA4810-CAPEA6030D3-GMVM970804CN","price":10566.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030c3-grvt960804cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030C3 + GRVT960804CN | 21\" Upflow\/Downflow Coil | 80,000 BTU Downflow Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GRVT960804CN two-stage gas furnace (96% AFUE, 80,000 BTU) and a CAPEA6030C3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989216. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 21\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT960804CN\u003c\/strong\u003e — Goodman 80,000 BTU 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace. Downflow configuration, Two-Stage gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GRVT960804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage \/ Two-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT960804CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657835086144,"sku":"GZV9SA4810-CAPEA6030C3-GRVT960804CN","price":10500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030c3-gcvm971005cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030C3 + GCVM971005CN | Communicating | 21\" Upflow\/Downflow Coil | 100,000 BTU Downflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GCVM971005CN modulating gas furnace (97% AFUE, 100,000 BTU) and a CAPEA6030C3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989232. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 21\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM971005CN\u003c\/strong\u003e — Goodman 100,000 BTU 97% AFUE Modulating Variable-Speed ECM Gas Furnace. Downflow\/Horizontal configuration, Modulating gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 97% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GCVM971005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eModulating \/ Modulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets 16+ SEER2 \/ 9+ HSPF2 and furnace meets 97%+ AFUE thresholds. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM971005CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657835118912,"sku":"GZV9SA4810-CAPEA6030C3-GCVM971005CN","price":10925.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Untitngnghnghn.jpg?v=1777796556"},{"product_id":"gzv9sa4810-capea6030d3-gdvt961205dn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GDVT961205DN | 24½\" Upflow\/Downflow Coil | 120,000 BTU Downflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GDVT961205DN two-stage gas furnace (96% AFUE, 120,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989210. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT961205DN\u003c\/strong\u003e — Goodman 120,000 BTU 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace. Downflow\/Horizontal configuration, Two-Stage gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GDVT961205DN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e120,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage \/ Two-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT961205DN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657835184448,"sku":"GZV9SA4810-CAPEA6030D3-GDVT961205DN","price":10991.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/NFGNFGNFGNd.jpg?v=1777341191"},{"product_id":"gzv9sa4810-capea6030d3-grvs960805cu","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GRVS960805CU | 24½\" Upflow\/Downflow Coil | 80,000 BTU Upflow\/Horizontal Single-Stage Variable-Speed ECM Ultra Low NOx Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GRVS960805CU single-stage gas furnace (96% AFUE, 80,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989226. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVS960805CU\u003c\/strong\u003e — Goodman 80,000 BTU 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Single-Stage gas valve, Ultra Low NOx. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989226\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GRVS960805CU\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage \/ Single-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eUltra Low NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVS960805CU (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657835249984,"sku":"GZV9SA4810-CAPEA6030D3-GRVS960805CU","price":11295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030c3-grvs960805cu","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030C3 + GRVS960805CU | 21\" Upflow\/Downflow Coil | 80,000 BTU Upflow\/Horizontal Single-Stage Variable-Speed ECM Ultra Low NOx Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GRVS960805CU single-stage gas furnace (96% AFUE, 80,000 BTU) and a CAPEA6030C3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989226. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 21\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVS960805CU\u003c\/strong\u003e — Goodman 80,000 BTU 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Single-Stage gas valve, Ultra Low NOx. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989226\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GRVS960805CU\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage \/ Single-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eUltra Low NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVS960805CU (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657835315520,"sku":"GZV9SA4810-CAPEA6030C3-GRVS960805CU","price":11285.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030c3-gdvt961005cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030C3 + GDVT961005CN | 21\" Upflow\/Downflow Coil | 100,000 BTU Downflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GDVT961005CN two-stage gas furnace (96% AFUE, 100,000 BTU) and a CAPEA6030C3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989214. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 21\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT961005CN\u003c\/strong\u003e — Goodman 100,000 BTU 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace. Downflow\/Horizontal configuration, Two-Stage gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GDVT961005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage \/ Two-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT961005CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657835348288,"sku":"GZV9SA4810-CAPEA6030C3-GDVT961005CN","price":10843.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/NFGNFGNFGNd.jpg?v=1777341191"},{"product_id":"gzv9sa4810-capea6030c3-grvt961005cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030C3 + GRVT961005CN | 21\" Upflow\/Downflow Coil | 100,000 BTU Downflow Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GRVT961005CN two-stage gas furnace (96% AFUE, 100,000 BTU) and a CAPEA6030C3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989214. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 21\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961005CN\u003c\/strong\u003e — Goodman 100,000 BTU 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace. Downflow configuration, Two-Stage gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GRVT961005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage \/ Two-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961005CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657835381056,"sku":"GZV9SA4810-CAPEA6030C3-GRVT961005CN","price":10754.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030d3-gmvc961205dn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GMVC961205DN | Communicating | 24½\" Upflow\/Downflow Coil | 120,000 BTU Upflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GMVC961205DN two-stage gas furnace (96% AFUE, 120,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 218003039. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVC961205DN\u003c\/strong\u003e — Goodman 120,000 BTU 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Two-Stage gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e218003039\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GMVC961205DN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e120,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage \/ Two-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVC961205DN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657835446592,"sku":"GZV9SA4810-CAPEA6030D3-GMVC961205DN","price":10614.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030c3-gdvt960804cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030C3 + GDVT960804CN | 21\" Upflow\/Downflow Coil | 80,000 BTU Downflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GDVT960804CN two-stage gas furnace (96% AFUE, 80,000 BTU) and a CAPEA6030C3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989216. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 21\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT960804CN\u003c\/strong\u003e — Goodman 80,000 BTU 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace. Downflow\/Horizontal configuration, Two-Stage gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GDVT960804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage \/ Two-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT960804CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657835512128,"sku":"GZV9SA4810-CAPEA6030C3-GDVT960804CN","price":10687.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/NFGNFGNFGNd.jpg?v=1777341191"},{"product_id":"gzv9sa4810-capea6030d3-grvt960804cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GRVT960804CN | 24½\" Upflow\/Downflow Coil | 80,000 BTU Downflow Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GRVT960804CN two-stage gas furnace (96% AFUE, 80,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989216. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT960804CN\u003c\/strong\u003e — Goodman 80,000 BTU 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace. Downflow configuration, Two-Stage gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GRVT960804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage \/ Two-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT960804CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657835577664,"sku":"GZV9SA4810-CAPEA6030D3-GRVT960804CN","price":10510.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030d3-gcvm971005cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GCVM971005CN | Communicating | 24½\" Upflow\/Downflow Coil | 100,000 BTU Downflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GCVM971005CN modulating gas furnace (97% AFUE, 100,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989232. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM971005CN\u003c\/strong\u003e — Goodman 100,000 BTU 97% AFUE Modulating Variable-Speed ECM Gas Furnace. Downflow\/Horizontal configuration, Modulating gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 97% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GCVM971005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eModulating \/ Modulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets 16+ SEER2 \/ 9+ HSPF2 and furnace meets 97%+ AFUE thresholds. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM971005CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657835708736,"sku":"GZV9SA4810-CAPEA6030D3-GCVM971005CN","price":10935.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Untitngnghnghn.jpg?v=1777796556"},{"product_id":"gzv9sa4810-capea6030d3-gcvc961205dn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GCVC961205DN | Communicating | 24½\" Upflow\/Downflow Coil | 120,000 BTU Downflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GCVC961205DN two-stage gas furnace (96% AFUE, 120,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 218003039. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVC961205DN\u003c\/strong\u003e — Goodman 120,000 BTU 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace. Downflow\/Horizontal configuration, Two-Stage gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e218003039\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GCVC961205DN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e120,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage \/ Two-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVC961205DN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657835839808,"sku":"GZV9SA4810-CAPEA6030D3-GCVC961205DN","price":10693.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Untitngnghnghn.jpg?v=1777796556"},{"product_id":"gzv9sa4810-capea6030c3-grvm970804cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030C3 + GRVM970804CN | 21\" Upflow\/Downflow Coil | 80,000 BTU Upflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GRVM970804CN modulating gas furnace (97% AFUE, 80,000 BTU) and a CAPEA6030C3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989234. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 21\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU 97% AFUE Modulating Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Modulating gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 97% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GRVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eModulating \/ Modulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets 16+ SEER2 \/ 9+ HSPF2 and furnace meets 97%+ AFUE thresholds. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM970804CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657835872576,"sku":"GZV9SA4810-CAPEA6030C3-GRVM970804CN","price":10841.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030d3-gmvm971005cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GMVM971005CN | Communicating | 24½\" Upflow\/Downflow Coil | 100,000 BTU Upflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GMVM971005CN modulating gas furnace (97% AFUE, 100,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989232. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM971005CN\u003c\/strong\u003e — Goodman 100,000 BTU 97% AFUE Modulating Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Modulating gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 97% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GMVM971005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eModulating \/ Modulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets 16+ SEER2 \/ 9+ HSPF2 and furnace meets 97%+ AFUE thresholds. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM971005CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657835905344,"sku":"GZV9SA4810-CAPEA6030D3-GMVM971005CN","price":10808.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030d3-gdvt960804cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GDVT960804CN | 24½\" Upflow\/Downflow Coil | 80,000 BTU Downflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GDVT960804CN two-stage gas furnace (96% AFUE, 80,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989216. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT960804CN\u003c\/strong\u003e — Goodman 80,000 BTU 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace. Downflow\/Horizontal configuration, Two-Stage gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GDVT960804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage \/ Two-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets threshold. Furnace AFUE may or may not meet current IRS minimum. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT960804CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657836036416,"sku":"GZV9SA4810-CAPEA6030D3-GDVT960804CN","price":10697.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/NFGNFGNFGNd.jpg?v=1777341191"},{"product_id":"gzv9sa4810-capea6030d3-grvm971005cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030D3 + GRVM971005CN | 24½\" Upflow\/Downflow Coil | 100,000 BTU Upflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GRVM971005CN modulating gas furnace (97% AFUE, 100,000 BTU) and a CAPEA6030D3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989232. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM971005CN\u003c\/strong\u003e — Goodman 100,000 BTU 97% AFUE Modulating Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Modulating gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 97% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GRVM971005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eModulating \/ Modulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets 16+ SEER2 \/ 9+ HSPF2 and furnace meets 97%+ AFUE thresholds. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM971005CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657836331328,"sku":"GZV9SA4810-CAPEA6030D3-GRVM971005CN","price":11117.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030c3-gmvm971005cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030C3 + GMVM971005CN | Communicating | 21\" Upflow\/Downflow Coil | 100,000 BTU Upflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GMVM971005CN modulating gas furnace (97% AFUE, 100,000 BTU) and a CAPEA6030C3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989232. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 21\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM971005CN\u003c\/strong\u003e — Goodman 100,000 BTU 97% AFUE Modulating Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Modulating gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 97% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GMVM971005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eModulating \/ Modulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets 16+ SEER2 \/ 9+ HSPF2 and furnace meets 97%+ AFUE thresholds. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM971005CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657836396864,"sku":"GZV9SA4810-CAPEA6030C3-GMVM971005CN","price":10798.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-capea6030c3-grvm971005cn","title":"Goodman 4 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CAPEA6030C3 + GRVM971005CN | 21\" Upflow\/Downflow Coil | 100,000 BTU Upflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GRVM971005CN modulating gas furnace (97% AFUE, 100,000 BTU) and a CAPEA6030C3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 9.0 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989232. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman 5 Ton Cased Upflow\/Downflow Indoor Coil. Upflow\/Downflow configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 21\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM971005CN\u003c\/strong\u003e — Goodman 100,000 BTU 97% AFUE Modulating Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Modulating gas valve, Natural Gas. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 97% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GRVM971005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eModulating \/ Modulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Heat pump meets 16+ SEER2 \/ 9+ HSPF2 and furnace meets 97%+ AFUE thresholds. Verify current IRS guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM971005CN (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657836429632,"sku":"GZV9SA4810-CAPEA6030C3-GRVM971005CN","price":11107.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"gzv9sa4810-chpea4830d3-mbvk20dp1x00","title":"Goodman 4 Ton 17.5 SEER2 R-32 Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower | GZV9SA4810 + CHPEA4830D3 + MBVK20DP1X00 | 24½\" Horizontal Coil | 24½\" Multi-Positional Modular Blower","description":"\u003cp\u003eThis Goodman 4 Ton 17.5 SEER2 Central Heat Pump Split System with Evaporator Coil and Modular Blower pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the CHPEA4830D3 evaporator coil and MBVK20DP1X00 modular blower for all-electric heating and cooling using R-32 refrigerant. The system achieves up to 17.5 SEER2 \/ 11.0 EER2 in cooling and 8.5 HSPF2 in heating. AHRI Certificate Number: 217989205. Energy Star Cold Climate Certified.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830D3\u003c\/strong\u003e — Goodman 4 Ton Cased Horizontal Indoor Coil. Horizontal configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 30\" W x 21\" D x 24½\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMBVK20DP1X00\u003c\/strong\u003e — Goodman Multi-Position Variable-Speed ECM Modular Blower. Multi-Positional configuration, ¾ HP ECM motor, 208\/230V. Cabinet: 24½\" W x 21\" D x 30\" H.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Coil-Blower Stack Height \u0026amp; Refrigerant Line Sizing\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e When stacking the evaporator coil on a modular blower, total assembled height must be verified against available closet or attic clearance before finalizing the install. The GZV9S condenser ships with ⅞\" suction service valves — field-supplied ⅞\" to 1⅛\" adapters are required for the line set connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F using the factory charge (162 oz R-32 for 15 ft of ⅜\" liquid line). Adjust charge per the installation manual's final charge procedure for actual line set length. Improper charge leads to reduced capacity and compressor wear, often manifesting as performance complaints 6–12 months post-install.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge calibrated for R-32 and a pipe-clamp thermometer at the liquid service valve. Confirm EEV superheat is in auto-control mode via the CoolCloud™ app.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable) under ASHRAE 34. EPA Section 608 certification is required. Follow local mechanical codes for charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) aligns with EPA AIM Act phase-down schedules.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 17.5 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eCentral Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e45,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e46,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e29,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA4830D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eModular Blower — MBVK20DP1X00\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e¾ HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e208\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e86 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Consult IRS Form 5695 and EnergyStar.gov for current SEER2\/HSPF2\/AFUE thresholds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830D3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMBVK20DP1X00 (Modular Blower):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCAHPQK. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657836790080,"sku":"GZV9SA4810-CHPEA4830D3-MBVK20DP1X00","price":8555.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/dtdyjdfuitled.jpg?v=1777814513"},{"product_id":"gzv7sa4810-ahve60dp0300-215429752","title":"Goodman | 4 Ton | 17.5 SEER2 | R-32 | Central Heat Pump Split System | GZV7SA4810 | AHVE60DP0300 | 24½\" Multi-Positional Air Handler","description":"\u003cp\u003eThis Goodman 4-Ton Central Heat Pump Split System pairs the GZV7SA4810 variable-speed, inverter-driven R-32 heat pump condenser with the AHVE60DP0300 multi-positional air handler. AHRI certified under #215429752, this matched system achieves up to 17.5 SEER2 and 8.8 HSPF2.\u003c\/p\u003e\n\u003cp\u003eThis system is ENERGY STAR® Most Efficient certified and qualifies as a Cold Climate Heat Pump.\u003c\/p\u003e\n\u003cp\u003eR-32 refrigerant offers a 67.5% lower Global Warming Potential (GWP of 675) compared to R-410A (GWP of 2,088), aligning with EPA regulations and the AIM Act phase-down schedule.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA4810\u003c\/strong\u003e — Goodman GZV7S Series 4-Ton Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser. Features variable-speed swing compressor, EEV metering, and communicating capability. Rated up to 46,500 BTU\/h cooling and 47,500 BTU\/h heating at 47°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHVE60DP0300\u003c\/strong\u003e — Goodman AHVE Series Multi-Positional Air Handler with variable-speed ECM blower motor and factory-installed electronic expansion valve (EEV). All-aluminum evaporator coil optimized for R-32. Cabinet width: 24½\"; depth: 21\".\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background-color:#f0f7ff;border-left:4px solid #0066cc;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e The AHVE air handler's 21\" cabinet depth is designed for attic access, but verify ceiling joist spacing accommodates the full footprint before positioning. Route the condensate drain with proper P-trap and slope to prevent standing water in the secondary drain pan.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e Commission the system in communicating mode to enable full variable-speed modulation. Set the correct tonnage and airflow parameters through the connected thermostat — incorrect setup defaults to legacy mode and sacrifices the efficiency gains that justify the SEER2 rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e After evacuation, confirm the system holds below 500 microns for a minimum of 10 minutes using a digital micron gauge. Verify subcooling at the service valve reads 9±1°F per GZV7S specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 installations require EPA Section 608 certification and compliance with ASHRAE 34 A2L safety classifications. Check local mechanical code requirements for refrigerant detector placement in confined spaces.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 17.5 SEER2 and 8.8 HSPF2 — AHRI-certified matched system efficiency reduces operating costs compared to minimum-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant with GWP of 675 — a 67.5% reduction from R-410A, supporting EPA AIM Act compliance and reducing environmental impact without sacrificing performance.\u003c\/li\u003e\n\u003cli\u003eVariable-speed inverter-driven compressor adjusts capacity continuously to match load, reducing temperature swings, improving dehumidification, and lowering sound levels in part-load conditions.\u003c\/li\u003e\n\u003cli\u003eENERGY STAR® Most Efficient and Cold Climate Heat Pump certified — may qualify for federal tax credits up to $2,000 under the Inflation Reduction Act (IRA) Section 25C for qualifying heat pump systems.\u003c\/li\u003e\n\u003cli\u003eQuiet-mode operation reduces outdoor sound levels to as low as 45 dBA (sound pressure at 3 feet), equivalent to a quiet library environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eAHRI-Certified System Ratings\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215429752\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (M1)\u003c\/td\u003e\n\u003ctd\u003e46,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity – High (M1) @ 47°F\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd\u003e29,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eOutdoor Unit — GZV7SA4810\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e37\" × 12⅝\" × 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230\/1\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Overcurrent Protection (MOCP)\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line Size\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line Size\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Rating (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e73\/73 dBA (Sound Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eAir Handler — AHVE60DP0300\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W × D)\u003c\/td\u003e\n\u003ctd\u003e24½\" × 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM (1 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e167 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-size:0.9em;font-style:italic;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eCompliance \u0026amp; Environmental Data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (67.5% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnician certification required for handling R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIM Act Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets HFC phase-down requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR®\u003c\/td\u003e\n\u003ctd\u003eMost Efficient \/ Cold Climate Heat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eMay qualify for up to $2,000 federal tax credit under IRA Section 25C for heat pump systems meeting CEE highest efficiency tier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 regional efficiency standards for all U.S. regions. Verify local mechanical permit and refrigerant detection requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV7SA4810):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered online at goodmanmfg.com within 60 days of installation: 10-Year Registered Parts Limited Warranty plus 10-Year Unit Replacement Limited Warranty for compressor failure (one-time replacement of entire unit). Registration required in most states. Warranty applies to owner-occupied residences only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Handler (AHVE60DP0300):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Registered Parts Limited Warranty for all parts. Applies to owner-occupied residential installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegistration Deadline:\u003c\/strong\u003e Online registration must be completed within 60 days of installation at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003ewww.goodmanmfg.com\u003c\/a\u003e. Registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e All warranty coverage requires installation by a licensed HVAC contractor adhering to federal, state, and local codes. Warranty does not cover units installed in non-owner-occupied residences or commercial properties. Units ordered online must be installed by a qualifying dealer.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658770612544,"sku":"GZV7SA4810-AHVE60DP0300-215429752","price":6880.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/BMitled.jpg?v=1777641264"},{"product_id":"gzv7sa4810-ahve60dp1300-215429199","title":"Goodman | 4 Ton | 17.5 SEER2 | R-32 | Central Heat Pump Split System | GZV7SA4810 | AHVE60DP1300 | 21\" Multi-Positional Air Handler","description":"\u003cp\u003eThis Goodman 4-Ton Central Heat Pump Split System pairs the GZV7SA4810 variable-speed, inverter-driven R-32 heat pump condenser with the AHVE60DP1300 multi-positional air handler. AHRI certified under #215429199, this matched system achieves up to 17.5 SEER2 and 8.8 HSPF2.\u003c\/p\u003e\n\u003cp\u003eThis system is ENERGY STAR® Most Efficient certified and qualifies as a Cold Climate Heat Pump.\u003c\/p\u003e\n\u003cp\u003eR-32 refrigerant offers a 67.5% lower Global Warming Potential (GWP of 675) compared to R-410A (GWP of 2,088), aligning with EPA regulations and the AIM Act phase-down schedule.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA4810\u003c\/strong\u003e — Goodman GZV7S Series 4-Ton Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser. Features variable-speed swing compressor, EEV metering, and communicating capability. Rated up to 46,500 BTU\/h cooling and 47,500 BTU\/h heating at 47°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHVE60DP1300\u003c\/strong\u003e — Goodman AHVE6 Series Cased Multi-Positional Evaporator Coil with expansion device. All-aluminum coil optimized for R-32 refrigerant. Cabinet width: 21\"; depth: 21.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background-color:#f0f7ff;border-left:4px solid #0066cc;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e The AHVE air handler's 21\" cabinet depth is designed for attic access, but verify ceiling joist spacing accommodates the full footprint before positioning. Route the condensate drain with proper P-trap and slope to prevent standing water in the secondary drain pan.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e Commission the system in communicating mode to enable full variable-speed modulation. Set the correct tonnage and airflow parameters through the connected thermostat — incorrect setup defaults to legacy mode and sacrifices the efficiency gains that justify the SEER2 rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e After evacuation, confirm the system holds below 500 microns for a minimum of 10 minutes using a digital micron gauge. Verify subcooling at the service valve reads 9±1°F per GZV7S specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 installations require EPA Section 608 certification and compliance with ASHRAE 34 A2L safety classifications. Check local mechanical code requirements for refrigerant detector placement in confined spaces.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 17.5 SEER2 and 8.8 HSPF2 — AHRI-certified matched system efficiency reduces operating costs compared to minimum-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant with GWP of 675 — a 67.5% reduction from R-410A, supporting EPA AIM Act compliance and reducing environmental impact without sacrificing performance.\u003c\/li\u003e\n\u003cli\u003eVariable-speed inverter-driven compressor adjusts capacity continuously to match load, reducing temperature swings, improving dehumidification, and lowering sound levels in part-load conditions.\u003c\/li\u003e\n\u003cli\u003eENERGY STAR® Most Efficient and Cold Climate Heat Pump certified — may qualify for federal tax credits up to $2,000 under the Inflation Reduction Act (IRA) Section 25C for qualifying heat pump systems.\u003c\/li\u003e\n\u003cli\u003eQuiet-mode operation reduces outdoor sound levels to as low as 45 dBA (sound pressure at 3 feet), equivalent to a quiet library environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eAHRI-Certified System Ratings\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215429199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (M1)\u003c\/td\u003e\n\u003ctd\u003e46,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity – High (M1) @ 47°F\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd\u003e29,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eOutdoor Unit — GZV7SA4810\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e37\" × 12⅝\" × 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230\/1\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Overcurrent Protection (MOCP)\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line Size\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line Size\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Rating (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e73\/73 dBA (Sound Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eEvaporator Coil — AHVE60DP1300\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e21\" × 21 × 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION] lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-size:0.9em;font-style:italic;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eCompliance \u0026amp; Environmental Data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (67.5% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnician certification required for handling R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIM Act Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets HFC phase-down requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR®\u003c\/td\u003e\n\u003ctd\u003eMost Efficient \/ Cold Climate Heat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eMay qualify for up to $2,000 federal tax credit under IRA Section 25C for heat pump systems meeting CEE highest efficiency tier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 regional efficiency standards for all U.S. regions. Verify local mechanical permit and refrigerant detection requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV7SA4810):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered online at goodmanmfg.com within 60 days of installation: 10-Year Registered Parts Limited Warranty plus 10-Year Unit Replacement Limited Warranty for compressor failure (one-time replacement of entire unit). Registration required in most states. Warranty applies to owner-occupied residences only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Handler (AHVE60DP1300):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Registered Parts Limited Warranty for all parts. Applies to owner-occupied residential installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegistration Deadline:\u003c\/strong\u003e Online registration must be completed within 60 days of installation at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003ewww.goodmanmfg.com\u003c\/a\u003e. Registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e All warranty coverage requires installation by a licensed HVAC contractor adhering to federal, state, and local codes. Warranty does not cover units installed in non-owner-occupied residences or commercial properties. Units ordered online must be installed by a qualifying dealer.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658770645312,"sku":"GZV7SA4810-AHVE60DP1300-215429199","price":6880.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/BMitled.jpg?v=1777641264"},{"product_id":"gzv7sa4810-capea6030d3-mbvk20dp1x00-215433960","title":"Goodman | 4 Ton | 17.5 SEER2 | R-32 | Central Heat Pump Split System with Evaporator Coil \u0026 Modular Blower | GZV7SA4810 | CAPEA6030D3 | MBVK20DP1X00 | 24½\" Upflow\/Downflow Coil | 24½\" Multi-Positional Modular Blower","description":"\u003cp\u003eThis Goodman 4-Ton system pairs the GZV7SA4810 variable-speed, inverter-driven R-32 heat pump with the CAPEA6030D3 evaporator coil and MBVK20DP1X00 modular blower. AHRI certified under #215433960, this configuration delivers up to 17.5 SEER2 and 8.8 HSPF2.\u003c\/p\u003e\n\u003cp\u003eThis system is ENERGY STAR® Most Efficient certified and qualifies as a Cold Climate Heat Pump.\u003c\/p\u003e\n\u003cp\u003eR-32 refrigerant offers a 67.5% lower Global Warming Potential (GWP of 675) compared to R-410A (GWP of 2,088), aligning with EPA regulations and the AIM Act phase-down schedule.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA4810\u003c\/strong\u003e — Goodman GZV7S Series 4-Ton Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser. Features variable-speed swing compressor, EEV metering, and communicating capability. Rated up to 46,500 BTU\/h cooling and 47,500 BTU\/h heating at 47°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman CAPEA Series Cased Upflow\/Downflow Evaporator Coil with factory-installed EEV. All-aluminum coil optimized for R-32. Cabinet width: 24½\"; depth: 21\"\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMBVK20DP1X00\u003c\/strong\u003e — Goodman MBVK Series Multi-Position Variable-Speed ECM Modular Blower. 2000 CFM capacity with communicating controls. Cabinet: 24½\" W × 21\" D × 30\" H.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background-color:#f0f7ff;border-left:4px solid #0066cc;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e When connecting the CAPEA6030D3 coil to the GZV7SA4810 outdoor unit, note the suction valve is ⅞\" while the required suction line is 1⅛\" — ⅞\" to 1⅛\" adapters are required. In horizontal attic installations, the 21\" coil depth fits standard joist bays, but confirm clearance for the control box access panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e With EEV metering on both the outdoor unit and indoor coil, the system self-adjusts superheat — but this depends on clean sensor readings. Wrap the coil temperature sensor securely and protect it from contact with the drain pan to prevent erratic EEV behavior that causes short-cycling complaints months after installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Pull the system down below 500 microns and hold for 10+ minutes on a digital micron gauge. Verify subcooling at the service valve reads 9±1°F. The unit ships charged for 15 feet of ⅜\" liquid line — adjust charge per the installation manual for longer runs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified A2L under ASHRAE 34. EPA Section 608 certification is required, and local codes may require refrigerant detection in confined mechanical rooms. Ensure the outdoor unit has proper clearance from property lines for sound compliance (73 dBA at normal mode).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 17.5 SEER2 and 8.8 HSPF2 — AHRI-certified matched system efficiency reduces operating costs compared to minimum-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant with GWP of 675 — a 67.5% reduction from R-410A, supporting EPA AIM Act compliance and reducing environmental impact without sacrificing performance.\u003c\/li\u003e\n\u003cli\u003eVariable-speed inverter-driven compressor adjusts capacity continuously to match load, reducing temperature swings, improving dehumidification, and lowering sound levels in part-load conditions.\u003c\/li\u003e\n\u003cli\u003eENERGY STAR® Most Efficient and Cold Climate Heat Pump certified — may qualify for federal tax credits up to $2,000 under the Inflation Reduction Act (IRA) Section 25C for qualifying heat pump systems.\u003c\/li\u003e\n\u003cli\u003eQuiet-mode operation reduces outdoor sound levels to as low as 45 dBA (sound pressure at 3 feet), equivalent to a quiet library environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eAHRI-Certified System Ratings\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215433960\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (M1)\u003c\/td\u003e\n\u003ctd\u003e45,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity – High (M1) @ 47°F\u003c\/td\u003e\n\u003ctd\u003e47,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd\u003e29,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eOutdoor Unit — GZV7SA4810\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e37\" × 12⅝\" × 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230\/1\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Overcurrent Protection (MOCP)\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line Size\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line Size\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Rating (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e73\/73 dBA (Sound Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eEvaporator Coil — CAPEA6030D3\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e24½\" × 21\" × 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eModular Blower — MBVK20DP1X00\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e24½\" × 21\" × 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM (¾ HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFM Rating\u003c\/td\u003e\n\u003ctd\u003e2000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e86 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-size:0.9em;font-style:italic;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eCompliance \u0026amp; Environmental Data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (67.5% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnician certification required for handling R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIM Act Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets HFC phase-down requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR®\u003c\/td\u003e\n\u003ctd\u003eMost Efficient \/ Cold Climate Heat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eMay qualify for up to $2,000 federal tax credit under IRA Section 25C for heat pump systems meeting CEE highest efficiency tier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 regional efficiency standards for all U.S. regions. Verify local mechanical permit and refrigerant detection requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV7SA4810):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered online at goodmanmfg.com within 60 days of installation: 10-Year Registered Parts Limited Warranty plus 10-Year Unit Replacement Limited Warranty for compressor failure (one-time replacement of entire unit). Registration required in most states. Warranty applies to owner-occupied residences only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Registered Parts Limited Warranty. Applies to owner-occupied residential installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower (MBVK20DP1X00):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Registered Parts Limited Warranty. Applies to owner-occupied residential installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegistration Deadline:\u003c\/strong\u003e Online registration must be completed within 60 days of installation at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003ewww.goodmanmfg.com\u003c\/a\u003e. Registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e All warranty coverage requires installation by a licensed HVAC contractor adhering to federal, state, and local codes. Warranty does not cover units installed in non-owner-occupied residences or commercial properties. Units ordered online must be installed by a qualifying dealer.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658770776384,"sku":"GZV7SA4810-CAPEA6030D3-MBVK20DP1X00-215433960","price":6615.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Untitled_a85500c2-4ff9-4614-9c22-0187ce6b0e00.jpg?v=1777630374"},{"product_id":"gzv7sa4810-chpea4830d3-mbvk20dp1x00-215433962","title":"Goodman | 4 Ton | 17.5 SEER2 | R-32 | Central Heat Pump Split System with Evaporator Coil \u0026 Modular Blower | GZV7SA4810 | CHPEA4830D3 | MBVK20DP1X00 | 30\" Horizontal Coil | 24½\" Multi-Positional Modular Blower","description":"\u003cp\u003eThis Goodman 4-Ton system pairs the GZV7SA4810 variable-speed, inverter-driven R-32 heat pump with the CHPEA4830D3 evaporator coil and MBVK20DP1X00 modular blower. AHRI certified under #215433962, this configuration delivers up to 17.5 SEER2 and 8.5 HSPF2.\u003c\/p\u003e\n\u003cp\u003eThis system is ENERGY STAR® Most Efficient certified and qualifies as a Cold Climate Heat Pump.\u003c\/p\u003e\n\u003cp\u003eR-32 refrigerant offers a 67.5% lower Global Warming Potential (GWP of 675) compared to R-410A (GWP of 2,088), aligning with EPA regulations and the AIM Act phase-down schedule.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA4810\u003c\/strong\u003e — Goodman GZV7S Series 4-Ton Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser. Features variable-speed swing compressor, EEV metering, and communicating capability. Rated up to 46,500 BTU\/h cooling and 47,500 BTU\/h heating at 47°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830D3\u003c\/strong\u003e — Goodman CHPEA Series Cased Horizontal Evaporator Coil with factory-installed EEV. All-aluminum coil optimized for R-32. Cabinet width: 30\"; depth: 21\"\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMBVK20DP1X00\u003c\/strong\u003e — Goodman MBVK Series Multi-Position Variable-Speed ECM Modular Blower. 2000 CFM capacity with communicating controls. Cabinet: 24½\" W × 21\" D × 30\" H.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background-color:#f0f7ff;border-left:4px solid #0066cc;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e When connecting the CHPEA4830D3 coil to the GZV7SA4810 outdoor unit, note the suction valve is ⅞\" while the required suction line is 1⅛\" — ⅞\" to 1⅛\" adapters are required. In horizontal attic installations, the 21\" coil depth fits standard joist bays, but confirm clearance for the control box access panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e With EEV metering on both the outdoor unit and indoor coil, the system self-adjusts superheat — but this depends on clean sensor readings. Wrap the coil temperature sensor securely and protect it from contact with the drain pan to prevent erratic EEV behavior that causes short-cycling complaints months after installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Pull the system down below 500 microns and hold for 10+ minutes on a digital micron gauge. Verify subcooling at the service valve reads 9±1°F. The unit ships charged for 15 feet of ⅜\" liquid line — adjust charge per the installation manual for longer runs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified A2L under ASHRAE 34. EPA Section 608 certification is required, and local codes may require refrigerant detection in confined mechanical rooms. Ensure the outdoor unit has proper clearance from property lines for sound compliance (73 dBA at normal mode).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 17.5 SEER2 and 8.5 HSPF2 — AHRI-certified matched system efficiency reduces operating costs compared to minimum-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant with GWP of 675 — a 67.5% reduction from R-410A, supporting EPA AIM Act compliance and reducing environmental impact without sacrificing performance.\u003c\/li\u003e\n\u003cli\u003eVariable-speed inverter-driven compressor adjusts capacity continuously to match load, reducing temperature swings, improving dehumidification, and lowering sound levels in part-load conditions.\u003c\/li\u003e\n\u003cli\u003eENERGY STAR® Most Efficient and Cold Climate Heat Pump certified — may qualify for federal tax credits up to $2,000 under the Inflation Reduction Act (IRA) Section 25C for qualifying heat pump systems.\u003c\/li\u003e\n\u003cli\u003eQuiet-mode operation reduces outdoor sound levels to as low as 45 dBA (sound pressure at 3 feet), equivalent to a quiet library environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eAHRI-Certified System Ratings\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215433962\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (M1)\u003c\/td\u003e\n\u003ctd\u003e45,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity – High (M1) @ 47°F\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd\u003e28,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eOutdoor Unit — GZV7SA4810\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e37\" × 12⅝\" × 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230\/1\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Overcurrent Protection (MOCP)\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line Size\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line Size\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Rating (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e73\/73 dBA (Sound Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eEvaporator Coil — CHPEA4830D3\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e30\" × 21\" × 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eModular Blower — MBVK20DP1X00\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e24½\" × 21\" × 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM (¾ HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFM Rating\u003c\/td\u003e\n\u003ctd\u003e2000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e86 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-size:0.9em;font-style:italic;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eCompliance \u0026amp; Environmental Data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (67.5% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnician certification required for handling R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIM Act Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets HFC phase-down requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR®\u003c\/td\u003e\n\u003ctd\u003eMost Efficient \/ Cold Climate Heat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eMay qualify for up to $2,000 federal tax credit under IRA Section 25C for heat pump systems meeting CEE highest efficiency tier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 regional efficiency standards for all U.S. regions. Verify local mechanical permit and refrigerant detection requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV7SA4810):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered online at goodmanmfg.com within 60 days of installation: 10-Year Registered Parts Limited Warranty plus 10-Year Unit Replacement Limited Warranty for compressor failure (one-time replacement of entire unit). Registration required in most states. Warranty applies to owner-occupied residences only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830D3):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Registered Parts Limited Warranty. Applies to owner-occupied residential installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower (MBVK20DP1X00):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Registered Parts Limited Warranty. Applies to owner-occupied residential installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegistration Deadline:\u003c\/strong\u003e Online registration must be completed within 60 days of installation at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003ewww.goodmanmfg.com\u003c\/a\u003e. Registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e All warranty coverage requires installation by a licensed HVAC contractor adhering to federal, state, and local codes. Warranty does not cover units installed in non-owner-occupied residences or commercial properties. Units ordered online must be installed by a qualifying dealer.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658770874688,"sku":"GZV7SA4810-CHPEA4830D3-MBVK20DP1X00-215433962","price":6487.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Untitled_a85500c2-4ff9-4614-9c22-0187ce6b0e00.jpg?v=1777630374"},{"product_id":"gzv7sa4810-chpea6030d3-mbvk20dp1x00-215433964","title":"Goodman | 4 Ton | 17.5 SEER2 | R-32 | Central Heat Pump Split System with Evaporator Coil \u0026 Modular Blower | GZV7SA4810 | CHPEA6030D3 | MBVK20DP1X00 | 30\" Horizontal Coil | 24½\" Multi-Positional Modular Blower","description":"\u003cp\u003eThis Goodman 4-Ton system pairs the GZV7SA4810 variable-speed, inverter-driven R-32 heat pump with the CHPEA6030D3 evaporator coil and MBVK20DP1X00 modular blower. AHRI certified under #215433964, this configuration delivers up to 17.5 SEER2 and 8.5 HSPF2.\u003c\/p\u003e\n\u003cp\u003eThis system is ENERGY STAR® Most Efficient certified and qualifies as a Cold Climate Heat Pump.\u003c\/p\u003e\n\u003cp\u003eR-32 refrigerant offers a 67.5% lower Global Warming Potential (GWP of 675) compared to R-410A (GWP of 2,088), aligning with EPA regulations and the AIM Act phase-down schedule.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA4810\u003c\/strong\u003e — Goodman GZV7S Series 4-Ton Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser. Features variable-speed swing compressor, EEV metering, and communicating capability. Rated up to 46,500 BTU\/h cooling and 47,500 BTU\/h heating at 47°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e — Goodman CHPEA Series Cased Horizontal Evaporator Coil with factory-installed EEV. All-aluminum coil optimized for R-32. Cabinet width: 30\"; depth: 21\"\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMBVK20DP1X00\u003c\/strong\u003e — Goodman MBVK Series Multi-Position Variable-Speed ECM Modular Blower. 2000 CFM capacity with communicating controls. Cabinet: 24½\" W × 21\" D × 30\" H.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background-color:#f0f7ff;border-left:4px solid #0066cc;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e When connecting the CHPEA6030D3 coil to the GZV7SA4810 outdoor unit, note the suction valve is ⅞\" while the required suction line is 1⅛\" — ⅞\" to 1⅛\" adapters are required. In horizontal attic installations, the 21\" coil depth fits standard joist bays, but confirm clearance for the control box access panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e With EEV metering on both the outdoor unit and indoor coil, the system self-adjusts superheat — but this depends on clean sensor readings. Wrap the coil temperature sensor securely and protect it from contact with the drain pan to prevent erratic EEV behavior that causes short-cycling complaints months after installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Pull the system down below 500 microns and hold for 10+ minutes on a digital micron gauge. Verify subcooling at the service valve reads 9±1°F. The unit ships charged for 15 feet of ⅜\" liquid line — adjust charge per the installation manual for longer runs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified A2L under ASHRAE 34. EPA Section 608 certification is required, and local codes may require refrigerant detection in confined mechanical rooms. Ensure the outdoor unit has proper clearance from property lines for sound compliance (73 dBA at normal mode).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 17.5 SEER2 and 8.5 HSPF2 — AHRI-certified matched system efficiency reduces operating costs compared to minimum-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant with GWP of 675 — a 67.5% reduction from R-410A, supporting EPA AIM Act compliance and reducing environmental impact without sacrificing performance.\u003c\/li\u003e\n\u003cli\u003eVariable-speed inverter-driven compressor adjusts capacity continuously to match load, reducing temperature swings, improving dehumidification, and lowering sound levels in part-load conditions.\u003c\/li\u003e\n\u003cli\u003eENERGY STAR® Most Efficient and Cold Climate Heat Pump certified — may qualify for federal tax credits up to $2,000 under the Inflation Reduction Act (IRA) Section 25C for qualifying heat pump systems.\u003c\/li\u003e\n\u003cli\u003eQuiet-mode operation reduces outdoor sound levels to as low as 45 dBA (sound pressure at 3 feet), equivalent to a quiet library environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eAHRI-Certified System Ratings\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215433964\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (M1)\u003c\/td\u003e\n\u003ctd\u003e45,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity – High (M1) @ 47°F\u003c\/td\u003e\n\u003ctd\u003e46,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd\u003e29,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eOutdoor Unit — GZV7SA4810\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e37\" × 12⅝\" × 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230\/1\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Overcurrent Protection (MOCP)\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line Size\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line Size\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Rating (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e73\/73 dBA (Sound Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eEvaporator Coil — CHPEA6030D3\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e30\" × 21\" × 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eModular Blower — MBVK20DP1X00\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e24½\" × 21\" × 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM (¾ HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFM Rating\u003c\/td\u003e\n\u003ctd\u003e2000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e86 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-size:0.9em;font-style:italic;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eCompliance \u0026amp; Environmental Data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (67.5% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnician certification required for handling R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIM Act Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets HFC phase-down requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR®\u003c\/td\u003e\n\u003ctd\u003eMost Efficient \/ Cold Climate Heat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eMay qualify for up to $2,000 federal tax credit under IRA Section 25C for heat pump systems meeting CEE highest efficiency tier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 regional efficiency standards for all U.S. regions. Verify local mechanical permit and refrigerant detection requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV7SA4810):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered online at goodmanmfg.com within 60 days of installation: 10-Year Registered Parts Limited Warranty plus 10-Year Unit Replacement Limited Warranty for compressor failure (one-time replacement of entire unit). Registration required in most states. Warranty applies to owner-occupied residences only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Registered Parts Limited Warranty. Applies to owner-occupied residential installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower (MBVK20DP1X00):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Registered Parts Limited Warranty. Applies to owner-occupied residential installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegistration Deadline:\u003c\/strong\u003e Online registration must be completed within 60 days of installation at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003ewww.goodmanmfg.com\u003c\/a\u003e. Registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e All warranty coverage requires installation by a licensed HVAC contractor adhering to federal, state, and local codes. Warranty does not cover units installed in non-owner-occupied residences or commercial properties. Units ordered online must be installed by a qualifying dealer.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658770940224,"sku":"GZV7SA4810-CHPEA6030D3-MBVK20DP1X00-215433964","price":6503.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Untitled_a85500c2-4ff9-4614-9c22-0187ce6b0e00.jpg?v=1777630374"}],"url":"https:\/\/minisplitsystemsdirect.com\/collections\/goodman-4-ton-systems-17-5-seer2.oembed","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}