{"title":"Goodman, 5 Ton Systems, 15.2 SEER2","description":null,"products":[{"product_id":"goodman-gzv7sa6010-chpea6030c3-gdvt960804cn","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV7SA6010 | CHPEA6030C3 | GDVT960804CN | 24½\" Cabinet Depth Horizontal Coil | 80,000 BTU\/h 96.0% AFUE Downflow\/Horizontal Natural Gas Two-Stage Furnace","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif; line-height:1.6; color:#333;\"\u003e\n\n\u003ch2 style=\"color:#005a9c;\"\u003eSystem Overview\u003c\/h2\u003e\n\u003cp\u003eThis Goodman 5-Ton Dual Fuel System pairs the GZV7SA6010 variable-speed, inverter-driven R-32 heat pump condenser with the CHPEA6030C3 cased evaporator coil and the GDVT960804CN 96.0% AFUE gas furnace. The system is AHRI certified (Certificate #216835335) and rated at 15.2 SEER2 \/ 9.8 EER2 \/ 8.5 HSPF2, qualifying for the ENERGY STAR Cold Climate Certified designation.\u003c\/p\u003e\n\u003cp\u003eDual fuel operation automatically switches between electric heat pump heating and gas furnace heating based on outdoor temperature, optimizing both comfort and operating cost across a wide range of climate conditions.\u003c\/p\u003e\n\u003cp style=\"font-style:italic; color:#555;\"\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA6010\u003c\/strong\u003e — Goodman 5-Ton Variable-Speed Inverter-Driven R-32 Side-Discharge Heat Pump Condenser (52,000 BTU\/h Cooling \/ 54,000 BTU\/h Heating @ 47°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030C3\u003c\/strong\u003e — Goodman 5-Ton Cased Horizontal Evaporator Coil, Horizontal, 24½\" Cabinet Depth, Internal EEV, All-Aluminum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT960804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h Input 96.0% AFUE Two-Stage Downflow\/Horizontal Gas Furnace, Variable-Speed ECM, Natural Gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #005a9c; padding:15px; margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip: Dual Fuel Changeover and Line Set Considerations\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e On 5-ton dual fuel installations with R-32 refrigerant, the GZV7SA6010 uses front-and-back sealing service valves with ⅞\" suction valve ports but requires 1⅛\" suction line sets. Installers will need to supply ⅞\" to 1⅛\" adapters for suction line connections. Confirm the furnace’s downflow\/horizontal configuration does not conflict with coil orientation or drain routing before committing to ductwork connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Set the dual fuel changeover (balance point) based on local utility rate structures and climate data, not factory defaults. A misconfigured balance point leads to unnecessary gas consumption in mild shoulder seasons or over-reliance on the heat pump at sub-optimal outdoor temperatures, resulting in nuisance high-pressure lockouts after 6–12 months.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e After final charge, use a digital manifold gauge with R-32 pressure-temperature charts to verify 11±1°F subcooling at the service valve. R-32’s higher operating pressures require careful leak testing with an electronic leak detector rated for A2L (mildly flammable) refrigerants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified as A2L (mildly flammable, GWP 675). All installations must comply with EPA Section 608 certification requirements and ASHRAE 15\/34 safety standards. Ensure adequate ventilation in confined installation spaces per local mechanical code and the unit’s installation instructions. The lower GWP of R-32 compared to R-410A supports AIM Act compliance targets.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Technology:\u003c\/strong\u003e The GZV7SA6010 uses a variable-speed swing compressor with inverter drive, modulating capacity from partial load to full output. This reduces short-cycling, lowers sound levels (as low as 45 dBA in Quiet Mode), and improves humidity control compared to single-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR Cold Climate Certified:\u003c\/strong\u003e This system meets the EPA’s stringent Cold Climate Heat Pump criteria, meaning it maintains effective heating capacity at temperatures well below freezing—delivering 46,000 BTU\/h at 5°F and supporting operation down to -10°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential of 675, approximately 68% lower than R-410A (GWP 2,088). This supports AIM Act and EPA Phasedown compliance while delivering improved thermodynamic efficiency per pound of refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Expansion Valve (EEV) Metering:\u003c\/strong\u003e Both the outdoor unit and the indoor coil utilize EEV technology for precise superheat and subcooling control across all operating conditions, reducing energy waste at part-load compared to fixed-orifice systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Economy:\u003c\/strong\u003e Automatic switchover between heat pump and gas furnace heating based on outdoor temperature balance point. The heat pump handles moderate-weather heating at higher efficiency, while the 96.0% AFUE furnace takes over during extreme cold when electric resistance supplemental heat would be cost-prohibitive.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Architecture:\u003c\/strong\u003e When paired with a Goodman GTST connected thermostat, the system uses two-wire communicating protocol between indoor and outdoor components for coordinated staging, fault diagnostics, and field-selectable boost mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\" border=\"1\" cellpadding=\"8\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005a9c; color:#fff;\"\u003e\n\u003cth style=\"text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e216835335\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e9.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32 (Charge: 162 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eee;font-weight:bold;\"\u003eOutdoor Unit — GZV7SA6010\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e52,000 BTU\/h @ 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity\u003c\/td\u003e\n\u003ctd\u003e54,000 BTU\/h @ 47°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (Low Temp)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h @ 5°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\"W x 12⅝\"D x 56⁵⁄₁₆\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e236 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Range (Cooling)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Range (Heating)\u003c\/td\u003e\n\u003ctd\u003e-10°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eee;font-weight:bold;\"\u003eEvaporator Coil — CHPEA6030C3\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Material\u003c\/td\u003e\n\u003ctd\u003eAll-Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eee;font-weight:bold;\"\u003eGas Furnace — GDVT960804CN\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-style:italic; color:#555;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eCompliance \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\" border=\"1\" cellpadding=\"8\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005a9c; color:#fff;\"\u003e\n\u003cth style=\"text-align:left;\"\u003eRequirement\u003c\/th\u003e\n\u003cth style=\"text-align:left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGWP (Global Warming Potential)\u003c\/td\u003e\n\u003ctd\u003e675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIM Act Compliance\u003c\/td\u003e\n\u003ctd\u003eR-32 supports EPA HFC phasedown targets (GWP well below the 700 threshold for residential AC\/HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR®\u003c\/td\u003e\n\u003ctd\u003eENERGY STAR Cold Climate Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions (A-Rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting the highest efficiency tier (CEE) may qualify for federal tax credits under the Inflation Reduction Act (25C). Verify current requirements at energystar.gov.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV7SA6010):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty. With online registration within 60 days of installation: 10-Year Unit Replacement Limited Warranty (if compressor fails, entire outdoor unit is replaced, one time) and 10-Year Parts Limited Warranty for the original registered homeowner. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty. With online registration within 60 days of installation: 10-Year Parts Limited Warranty for the original registered homeowner. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GDVT960804CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (with registration, good for as long as you own your home). 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty with online registration within 60 days of installation. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em; color:#555;\"\u003eWarranty terms vary by state and province. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. Complete warranty details are available at www.goodmanmfg.com. A licensed contractor must install the system for warranty eligibility.\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658783129920,"sku":"GZV7SA6010-CHPEA6030C3-GDVT960804CN","price":10215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/NFGNFGNFGNd.jpg?v=1777341191"},{"product_id":"goodman-gzv7sa6010-chpea6030d3-grvt960804cn","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV7SA6010 | CHPEA6030D3 | GRVT960804CN | 21\" Cabinet Depth Horizontal Coil | 80,000 BTU\/h 96.0% AFUE Downflow Natural Gas Two-Stage Furnace","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif; line-height:1.6; color:#333;\"\u003e\n\n\u003ch2 style=\"color:#005a9c;\"\u003eSystem Overview\u003c\/h2\u003e\n\u003cp\u003eThis Goodman 5-Ton Dual Fuel System pairs the GZV7SA6010 variable-speed, inverter-driven R-32 heat pump condenser with the CHPEA6030D3 cased evaporator coil and the GRVT960804CN 96.0% AFUE gas furnace. The system is AHRI certified (Certificate #216835335) and rated at 15.2 SEER2 \/ 9.8 EER2 \/ 8.5 HSPF2, qualifying for the ENERGY STAR Cold Climate Certified designation.\u003c\/p\u003e\n\u003cp\u003eDual fuel operation automatically switches between electric heat pump heating and gas furnace heating based on outdoor temperature, optimizing both comfort and operating cost across a wide range of climate conditions.\u003c\/p\u003e\n\u003cp style=\"font-style:italic; color:#555;\"\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA6010\u003c\/strong\u003e — Goodman 5-Ton Variable-Speed Inverter-Driven R-32 Side-Discharge Heat Pump Condenser (52,000 BTU\/h Cooling \/ 54,000 BTU\/h Heating @ 47°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e — Goodman 5-Ton Cased Horizontal Evaporator Coil, Horizontal, 21\" Cabinet Depth, Internal EEV, All-Aluminum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT960804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h Input 96.0% AFUE Two-Stage Downflow Gas Furnace, Variable-Speed ECM, Natural Gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #005a9c; padding:15px; margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip: Dual Fuel Changeover and Line Set Considerations\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e On 5-ton dual fuel installations with R-32 refrigerant, the GZV7SA6010 uses front-and-back sealing service valves with ⅞\" suction valve ports but requires 1⅛\" suction line sets. Installers will need to supply ⅞\" to 1⅛\" adapters for suction line connections. Confirm the furnace’s downflow configuration does not conflict with coil orientation or drain routing before committing to ductwork connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Set the dual fuel changeover (balance point) based on local utility rate structures and climate data, not factory defaults. A misconfigured balance point leads to unnecessary gas consumption in mild shoulder seasons or over-reliance on the heat pump at sub-optimal outdoor temperatures, resulting in nuisance high-pressure lockouts after 6–12 months.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e After final charge, use a digital manifold gauge with R-32 pressure-temperature charts to verify 11±1°F subcooling at the service valve. R-32’s higher operating pressures require careful leak testing with an electronic leak detector rated for A2L (mildly flammable) refrigerants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified as A2L (mildly flammable, GWP 675). All installations must comply with EPA Section 608 certification requirements and ASHRAE 15\/34 safety standards. Ensure adequate ventilation in confined installation spaces per local mechanical code and the unit’s installation instructions. The lower GWP of R-32 compared to R-410A supports AIM Act compliance targets.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Technology:\u003c\/strong\u003e The GZV7SA6010 uses a variable-speed swing compressor with inverter drive, modulating capacity from partial load to full output. This reduces short-cycling, lowers sound levels (as low as 45 dBA in Quiet Mode), and improves humidity control compared to single-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR Cold Climate Certified:\u003c\/strong\u003e This system meets the EPA’s stringent Cold Climate Heat Pump criteria, meaning it maintains effective heating capacity at temperatures well below freezing—delivering 46,000 BTU\/h at 5°F and supporting operation down to -10°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential of 675, approximately 68% lower than R-410A (GWP 2,088). This supports AIM Act and EPA Phasedown compliance while delivering improved thermodynamic efficiency per pound of refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Expansion Valve (EEV) Metering:\u003c\/strong\u003e Both the outdoor unit and the indoor coil utilize EEV technology for precise superheat and subcooling control across all operating conditions, reducing energy waste at part-load compared to fixed-orifice systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Economy:\u003c\/strong\u003e Automatic switchover between heat pump and gas furnace heating based on outdoor temperature balance point. The heat pump handles moderate-weather heating at higher efficiency, while the 96.0% AFUE furnace takes over during extreme cold when electric resistance supplemental heat would be cost-prohibitive.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Architecture:\u003c\/strong\u003e When paired with a Goodman GTST connected thermostat, the system uses two-wire communicating protocol between indoor and outdoor components for coordinated staging, fault diagnostics, and field-selectable boost mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\" border=\"1\" cellpadding=\"8\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005a9c; color:#fff;\"\u003e\n\u003cth style=\"text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e216835335\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e9.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32 (Charge: 162 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eee;font-weight:bold;\"\u003eOutdoor Unit — GZV7SA6010\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e52,000 BTU\/h @ 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity\u003c\/td\u003e\n\u003ctd\u003e54,000 BTU\/h @ 47°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (Low Temp)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h @ 5°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\"W x 12⅝\"D x 56⁵⁄₁₆\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e236 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Range (Cooling)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Range (Heating)\u003c\/td\u003e\n\u003ctd\u003e-10°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eee;font-weight:bold;\"\u003eEvaporator Coil — CHPEA6030D3\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Material\u003c\/td\u003e\n\u003ctd\u003eAll-Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eee;font-weight:bold;\"\u003eGas Furnace — GRVT960804CN\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-style:italic; color:#555;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eCompliance \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\" border=\"1\" cellpadding=\"8\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005a9c; color:#fff;\"\u003e\n\u003cth style=\"text-align:left;\"\u003eRequirement\u003c\/th\u003e\n\u003cth style=\"text-align:left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGWP (Global Warming Potential)\u003c\/td\u003e\n\u003ctd\u003e675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIM Act Compliance\u003c\/td\u003e\n\u003ctd\u003eR-32 supports EPA HFC phasedown targets (GWP well below the 700 threshold for residential AC\/HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR®\u003c\/td\u003e\n\u003ctd\u003eENERGY STAR Cold Climate Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions (A-Rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting the highest efficiency tier (CEE) may qualify for federal tax credits under the Inflation Reduction Act (25C). Verify current requirements at energystar.gov.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV7SA6010):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty. With online registration within 60 days of installation: 10-Year Unit Replacement Limited Warranty (if compressor fails, entire outdoor unit is replaced, one time) and 10-Year Parts Limited Warranty for the original registered homeowner. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty. With online registration within 60 days of installation: 10-Year Parts Limited Warranty for the original registered homeowner. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT960804CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (with registration, good for as long as you own your home). 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty with online registration within 60 days of installation. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em; color:#555;\"\u003eWarranty terms vary by state and province. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. Complete warranty details are available at www.goodmanmfg.com. A licensed contractor must install the system for warranty eligibility.\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658783555904,"sku":"GZV7SA6010-CHPEA6030D3-GRVT960804CN","price":10036.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"goodman-gzv7sa6010-chpea6030d3-gdvt960804cn","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV7SA6010 | CHPEA6030D3 | GDVT960804CN | 21\" Cabinet Depth Horizontal Coil | 80,000 BTU\/h 96.0% AFUE Downflow\/Horizontal Natural Gas Two-Stage Furnace","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif; line-height:1.6; color:#333;\"\u003e\n\n\u003ch2 style=\"color:#005a9c;\"\u003eSystem Overview\u003c\/h2\u003e\n\u003cp\u003eThis Goodman 5-Ton Dual Fuel System pairs the GZV7SA6010 variable-speed, inverter-driven R-32 heat pump condenser with the CHPEA6030D3 cased evaporator coil and the GDVT960804CN 96.0% AFUE gas furnace. The system is AHRI certified (Certificate #216835335) and rated at 15.2 SEER2 \/ 9.8 EER2 \/ 8.5 HSPF2, qualifying for the ENERGY STAR Cold Climate Certified designation.\u003c\/p\u003e\n\u003cp\u003eDual fuel operation automatically switches between electric heat pump heating and gas furnace heating based on outdoor temperature, optimizing both comfort and operating cost across a wide range of climate conditions.\u003c\/p\u003e\n\u003cp style=\"font-style:italic; color:#555;\"\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA6010\u003c\/strong\u003e — Goodman 5-Ton Variable-Speed Inverter-Driven R-32 Side-Discharge Heat Pump Condenser (52,000 BTU\/h Cooling \/ 54,000 BTU\/h Heating @ 47°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e — Goodman 5-Ton Cased Horizontal Evaporator Coil, Horizontal, 21\" Cabinet Depth, Internal EEV, All-Aluminum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT960804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h Input 96.0% AFUE Two-Stage Downflow\/Horizontal Gas Furnace, Variable-Speed ECM, Natural Gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #005a9c; padding:15px; margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip: Dual Fuel Changeover and Line Set Considerations\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e On 5-ton dual fuel installations with R-32 refrigerant, the GZV7SA6010 uses front-and-back sealing service valves with ⅞\" suction valve ports but requires 1⅛\" suction line sets. Installers will need to supply ⅞\" to 1⅛\" adapters for suction line connections. Confirm the furnace’s downflow\/horizontal configuration does not conflict with coil orientation or drain routing before committing to ductwork connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Set the dual fuel changeover (balance point) based on local utility rate structures and climate data, not factory defaults. A misconfigured balance point leads to unnecessary gas consumption in mild shoulder seasons or over-reliance on the heat pump at sub-optimal outdoor temperatures, resulting in nuisance high-pressure lockouts after 6–12 months.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e After final charge, use a digital manifold gauge with R-32 pressure-temperature charts to verify 11±1°F subcooling at the service valve. R-32’s higher operating pressures require careful leak testing with an electronic leak detector rated for A2L (mildly flammable) refrigerants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified as A2L (mildly flammable, GWP 675). All installations must comply with EPA Section 608 certification requirements and ASHRAE 15\/34 safety standards. Ensure adequate ventilation in confined installation spaces per local mechanical code and the unit’s installation instructions. The lower GWP of R-32 compared to R-410A supports AIM Act compliance targets.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Technology:\u003c\/strong\u003e The GZV7SA6010 uses a variable-speed swing compressor with inverter drive, modulating capacity from partial load to full output. This reduces short-cycling, lowers sound levels (as low as 45 dBA in Quiet Mode), and improves humidity control compared to single-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR Cold Climate Certified:\u003c\/strong\u003e This system meets the EPA’s stringent Cold Climate Heat Pump criteria, meaning it maintains effective heating capacity at temperatures well below freezing—delivering 46,000 BTU\/h at 5°F and supporting operation down to -10°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential of 675, approximately 68% lower than R-410A (GWP 2,088). This supports AIM Act and EPA Phasedown compliance while delivering improved thermodynamic efficiency per pound of refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Expansion Valve (EEV) Metering:\u003c\/strong\u003e Both the outdoor unit and the indoor coil utilize EEV technology for precise superheat and subcooling control across all operating conditions, reducing energy waste at part-load compared to fixed-orifice systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Economy:\u003c\/strong\u003e Automatic switchover between heat pump and gas furnace heating based on outdoor temperature balance point. The heat pump handles moderate-weather heating at higher efficiency, while the 96.0% AFUE furnace takes over during extreme cold when electric resistance supplemental heat would be cost-prohibitive.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Architecture:\u003c\/strong\u003e When paired with a Goodman GTST connected thermostat, the system uses two-wire communicating protocol between indoor and outdoor components for coordinated staging, fault diagnostics, and field-selectable boost mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\" border=\"1\" cellpadding=\"8\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005a9c; color:#fff;\"\u003e\n\u003cth style=\"text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e216835335\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e9.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32 (Charge: 162 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eee;font-weight:bold;\"\u003eOutdoor Unit — GZV7SA6010\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e52,000 BTU\/h @ 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity\u003c\/td\u003e\n\u003ctd\u003e54,000 BTU\/h @ 47°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (Low Temp)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h @ 5°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\"W x 12⅝\"D x 56⁵⁄₁₆\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e236 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Range (Cooling)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Range (Heating)\u003c\/td\u003e\n\u003ctd\u003e-10°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eee;font-weight:bold;\"\u003eEvaporator Coil — CHPEA6030D3\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Material\u003c\/td\u003e\n\u003ctd\u003eAll-Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eee;font-weight:bold;\"\u003eGas Furnace — GDVT960804CN\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-style:italic; color:#555;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eCompliance \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\" border=\"1\" cellpadding=\"8\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005a9c; color:#fff;\"\u003e\n\u003cth style=\"text-align:left;\"\u003eRequirement\u003c\/th\u003e\n\u003cth style=\"text-align:left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGWP (Global Warming Potential)\u003c\/td\u003e\n\u003ctd\u003e675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIM Act Compliance\u003c\/td\u003e\n\u003ctd\u003eR-32 supports EPA HFC phasedown targets (GWP well below the 700 threshold for residential AC\/HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR®\u003c\/td\u003e\n\u003ctd\u003eENERGY STAR Cold Climate Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions (A-Rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting the highest efficiency tier (CEE) may qualify for federal tax credits under the Inflation Reduction Act (25C). Verify current requirements at energystar.gov.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV7SA6010):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty. With online registration within 60 days of installation: 10-Year Unit Replacement Limited Warranty (if compressor fails, entire outdoor unit is replaced, one time) and 10-Year Parts Limited Warranty for the original registered homeowner. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty. With online registration within 60 days of installation: 10-Year Parts Limited Warranty for the original registered homeowner. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GDVT960804CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (with registration, good for as long as you own your home). 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty with online registration within 60 days of installation. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em; color:#555;\"\u003eWarranty terms vary by state and province. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. Complete warranty details are available at www.goodmanmfg.com. A licensed contractor must install the system for warranty eligibility.\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658783654208,"sku":"GZV7SA6010-CHPEA6030D3-GDVT960804CN","price":10223.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/NFGNFGNFGNd.jpg?v=1777341191"},{"product_id":"goodman-gzv7sa6010-chpea6030c3-grvt960804cn","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV7SA6010 | CHPEA6030C3 | GRVT960804CN | 24½\" Cabinet Depth Horizontal Coil | 80,000 BTU\/h 96.0% AFUE Downflow Natural Gas Two-Stage Furnace","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif; line-height:1.6; color:#333;\"\u003e\n\n\u003ch2 style=\"color:#005a9c;\"\u003eSystem Overview\u003c\/h2\u003e\n\u003cp\u003eThis Goodman 5-Ton Dual Fuel System pairs the GZV7SA6010 variable-speed, inverter-driven R-32 heat pump condenser with the CHPEA6030C3 cased evaporator coil and the GRVT960804CN 96.0% AFUE gas furnace. The system is AHRI certified (Certificate #216835335) and rated at 15.2 SEER2 \/ 9.8 EER2 \/ 8.5 HSPF2, qualifying for the ENERGY STAR Cold Climate Certified designation.\u003c\/p\u003e\n\u003cp\u003eDual fuel operation automatically switches between electric heat pump heating and gas furnace heating based on outdoor temperature, optimizing both comfort and operating cost across a wide range of climate conditions.\u003c\/p\u003e\n\u003cp style=\"font-style:italic; color:#555;\"\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA6010\u003c\/strong\u003e — Goodman 5-Ton Variable-Speed Inverter-Driven R-32 Side-Discharge Heat Pump Condenser (52,000 BTU\/h Cooling \/ 54,000 BTU\/h Heating @ 47°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030C3\u003c\/strong\u003e — Goodman 5-Ton Cased Horizontal Evaporator Coil, Horizontal, 24½\" Cabinet Depth, Internal EEV, All-Aluminum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT960804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h Input 96.0% AFUE Two-Stage Downflow Gas Furnace, Variable-Speed ECM, Natural Gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #005a9c; padding:15px; margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip: Dual Fuel Changeover and Line Set Considerations\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e On 5-ton dual fuel installations with R-32 refrigerant, the GZV7SA6010 uses front-and-back sealing service valves with ⅞\" suction valve ports but requires 1⅛\" suction line sets. Installers will need to supply ⅞\" to 1⅛\" adapters for suction line connections. Confirm the furnace’s downflow configuration does not conflict with coil orientation or drain routing before committing to ductwork connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Set the dual fuel changeover (balance point) based on local utility rate structures and climate data, not factory defaults. A misconfigured balance point leads to unnecessary gas consumption in mild shoulder seasons or over-reliance on the heat pump at sub-optimal outdoor temperatures, resulting in nuisance high-pressure lockouts after 6–12 months.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e After final charge, use a digital manifold gauge with R-32 pressure-temperature charts to verify 11±1°F subcooling at the service valve. R-32’s higher operating pressures require careful leak testing with an electronic leak detector rated for A2L (mildly flammable) refrigerants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified as A2L (mildly flammable, GWP 675). All installations must comply with EPA Section 608 certification requirements and ASHRAE 15\/34 safety standards. Ensure adequate ventilation in confined installation spaces per local mechanical code and the unit’s installation instructions. The lower GWP of R-32 compared to R-410A supports AIM Act compliance targets.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Technology:\u003c\/strong\u003e The GZV7SA6010 uses a variable-speed swing compressor with inverter drive, modulating capacity from partial load to full output. This reduces short-cycling, lowers sound levels (as low as 45 dBA in Quiet Mode), and improves humidity control compared to single-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR Cold Climate Certified:\u003c\/strong\u003e This system meets the EPA’s stringent Cold Climate Heat Pump criteria, meaning it maintains effective heating capacity at temperatures well below freezing—delivering 46,000 BTU\/h at 5°F and supporting operation down to -10°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential of 675, approximately 68% lower than R-410A (GWP 2,088). This supports AIM Act and EPA Phasedown compliance while delivering improved thermodynamic efficiency per pound of refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Expansion Valve (EEV) Metering:\u003c\/strong\u003e Both the outdoor unit and the indoor coil utilize EEV technology for precise superheat and subcooling control across all operating conditions, reducing energy waste at part-load compared to fixed-orifice systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Economy:\u003c\/strong\u003e Automatic switchover between heat pump and gas furnace heating based on outdoor temperature balance point. The heat pump handles moderate-weather heating at higher efficiency, while the 96.0% AFUE furnace takes over during extreme cold when electric resistance supplemental heat would be cost-prohibitive.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Architecture:\u003c\/strong\u003e When paired with a Goodman GTST connected thermostat, the system uses two-wire communicating protocol between indoor and outdoor components for coordinated staging, fault diagnostics, and field-selectable boost mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\" border=\"1\" cellpadding=\"8\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005a9c; color:#fff;\"\u003e\n\u003cth style=\"text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e216835335\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e9.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32 (Charge: 162 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eee;font-weight:bold;\"\u003eOutdoor Unit — GZV7SA6010\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e52,000 BTU\/h @ 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity\u003c\/td\u003e\n\u003ctd\u003e54,000 BTU\/h @ 47°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (Low Temp)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h @ 5°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\"W x 12⅝\"D x 56⁵⁄₁₆\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e236 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Range (Cooling)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Range (Heating)\u003c\/td\u003e\n\u003ctd\u003e-10°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eee;font-weight:bold;\"\u003eEvaporator Coil — CHPEA6030C3\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Material\u003c\/td\u003e\n\u003ctd\u003eAll-Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eee;font-weight:bold;\"\u003eGas Furnace — GRVT960804CN\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-style:italic; color:#555;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eCompliance \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\" border=\"1\" cellpadding=\"8\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005a9c; color:#fff;\"\u003e\n\u003cth style=\"text-align:left;\"\u003eRequirement\u003c\/th\u003e\n\u003cth style=\"text-align:left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGWP (Global Warming Potential)\u003c\/td\u003e\n\u003ctd\u003e675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIM Act Compliance\u003c\/td\u003e\n\u003ctd\u003eR-32 supports EPA HFC phasedown targets (GWP well below the 700 threshold for residential AC\/HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR®\u003c\/td\u003e\n\u003ctd\u003eENERGY STAR Cold Climate Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions (A-Rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting the highest efficiency tier (CEE) may qualify for federal tax credits under the Inflation Reduction Act (25C). Verify current requirements at energystar.gov.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV7SA6010):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty. With online registration within 60 days of installation: 10-Year Unit Replacement Limited Warranty (if compressor fails, entire outdoor unit is replaced, one time) and 10-Year Parts Limited Warranty for the original registered homeowner. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty. With online registration within 60 days of installation: 10-Year Parts Limited Warranty for the original registered homeowner. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT960804CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (with registration, good for as long as you own your home). 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty with online registration within 60 days of installation. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em; color:#555;\"\u003eWarranty terms vary by state and province. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. Complete warranty details are available at www.goodmanmfg.com. A licensed contractor must install the system for warranty eligibility.\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658793419072,"sku":"GZV7SA6010-CHPEA6030C3-GRVT960804CN","price":10028.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281"},{"product_id":"goodman-gzv6sa6010-capea6030d3-grvt961005cn-ahri-215447298","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 Heat Pump + CAPEA6030D3 24-1\/2\" Cabinet Width Upflow\/Downflow Coil + GRVT961005CN 100,000 BTU Downflow Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447298) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GRVT961005CN 100,000 BTU\/h 96% AFUE gas furnace and the CAPEA6030D3 cased upflow\/downflow evaporator coil. Rated at 15.2 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V\/1Ph\/60Hz electrical. Dimensions: 37\" W x 12-5\/8\" D x 39\" H. Equipment Weight: 168 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — 5-Ton R-32 Cased Upflow\/Downflow Cased Evaporator Coil with EEV expansion device. Upflow\/Downflow configuration. Cabinet Dimensions: 24-1\/2\" W x 21\" D x 30\" H. Ship Weight: 78 lbs. Aluminum coil construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961005CN\u003c\/strong\u003e — 100,000 BTU\/h Input (96,100 BTU\/h Output) 96% AFUE Two-Stage Natural Gas Gas Furnace. Variable-Speed ECM circulator blower motor. Downflow configuration. Cabinet Dimensions: 21\" W x 28-7\/8\" D x 34-1\/2\" H. Direct Vent (Category IV) venting (2\"-3\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #c62828;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#c62828;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Downflow furnace installations with this 100,000 BTU two-stage gas furnace require careful attention to combustion air routing and condensate management. In tight closet or garage applications, the 21\" cabinet width can create clearance conflicts with the R-32 refrigerant line connections on the CAPEA6030D3 evaporator coil above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e Verify the condensate trap is installed per manufacturer instructions and confirm the drain slope before startup. R-32 systems operating at higher discharge pressures than R-410A predecessors will produce more condensate at peak cooling. A failed drain in a downflow application means water damage to the heat exchanger and burner assembly — the most expensive callback in HVAC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manometer to confirm negative pressure in the combustion chamber during operation. Target -0.02\" to -0.10\" W.C. at the draft inducer outlet. Document this reading on the commissioning report alongside your micron gauge evacuation record (500 microns or below, held for 10 minutes minimum with R-32).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e This system uses R-32 refrigerant (GWP 675), which is classified as A2L (mildly flammable). Ensure compliance with ASHRAE 15 and local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions now require leak detection equipment for A2L installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Combines 15.2 SEER2 \/ 8.2 HSPF2 heat pump performance with 96% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Airflow Management:\u003c\/strong\u003e The Variable-Speed ECM blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot\/cold spots and lowering operating noise compared to PSC motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Gas Valve:\u003c\/strong\u003e Two-stage gas valve operates at 70% capacity on low fire for most heating demand, reducing temperature swings and gas consumption while reserving full output for the coldest conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified Match:\u003c\/strong\u003e All components are AHRI-certified as a matched system (Certificate #215447298), ensuring rated performance is achieved when installed according to manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance Ratings (AHRI #215447298)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Heating Capacity (HP @ 47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Furnace Fit\u003c\/td\u003e\n\u003ctd\u003e1.75\" Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA6010\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs \/ 198 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CAPEA6030D3\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24-1\/2\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eGas Furnace — GRVT961005CN\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28-7\/8\" x 34-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e143 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect Vent (Category IV) — 2\"-3\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eNatural Gas — Standard NOx emissions; verify local air quality district requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotentially eligible — consult IRS guidelines and a qualified tax professional for current 25C\/25D credit requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447298\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star (Heat Pump)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA6010):\u003c\/strong\u003e 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT961005CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRefer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884530696512,"sku":"GZV6SA6010-CAPEA6030D3-GRVT961005CN","price":8690.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-chpea4830c3-grvt961005cn-ahri-215447283","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 Heat Pump + CHPEA4830C3 21\" Cabinet Height Horizontal Coil + GRVT961005CN 100,000 BTU Downflow Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447283) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GRVT961005CN 100,000 BTU\/h 96% AFUE gas furnace and the CHPEA4830C3 cased horizontal evaporator coil. Rated at 15.2 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V\/1Ph\/60Hz electrical. Dimensions: 37\" W x 12-5\/8\" D x 39\" H. Equipment Weight: 168 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830C3\u003c\/strong\u003e — 4-Ton R-32 Cased Horizontal Cased Evaporator Coil with EEV expansion device. Horizontal configuration. Cabinet Dimensions: 30\" W x 21\" D x 21\" H. Ship Weight: 76 lbs. Aluminum coil construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961005CN\u003c\/strong\u003e — 100,000 BTU\/h Input (96,100 BTU\/h Output) 96% AFUE Two-Stage Natural Gas Gas Furnace. Variable-Speed ECM circulator blower motor. Downflow configuration. Cabinet Dimensions: 21\" W x 28-7\/8\" D x 34-1\/2\" H. Direct Vent (Category IV) venting (2\"-3\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #c62828;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#c62828;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Downflow furnace installations with this 100,000 BTU two-stage gas furnace require careful attention to combustion air routing and condensate management. In tight closet or garage applications, the 21\" cabinet width can create clearance conflicts with the R-32 refrigerant line connections on the CHPEA4830C3 evaporator coil above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e Verify the condensate trap is installed per manufacturer instructions and confirm the drain slope before startup. R-32 systems operating at higher discharge pressures than R-410A predecessors will produce more condensate at peak cooling. A failed drain in a downflow application means water damage to the heat exchanger and burner assembly — the most expensive callback in HVAC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manometer to confirm negative pressure in the combustion chamber during operation. Target -0.02\" to -0.10\" W.C. at the draft inducer outlet. Document this reading on the commissioning report alongside your micron gauge evacuation record (500 microns or below, held for 10 minutes minimum with R-32).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e This system uses R-32 refrigerant (GWP 675), which is classified as A2L (mildly flammable). Ensure compliance with ASHRAE 15 and local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions now require leak detection equipment for A2L installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Combines 15.2 SEER2 \/ 8.2 HSPF2 heat pump performance with 96% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Airflow Management:\u003c\/strong\u003e The Variable-Speed ECM blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot\/cold spots and lowering operating noise compared to PSC motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Gas Valve:\u003c\/strong\u003e Two-stage gas valve operates at 70% capacity on low fire for most heating demand, reducing temperature swings and gas consumption while reserving full output for the coldest conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified Match:\u003c\/strong\u003e All components are AHRI-certified as a matched system (Certificate #215447283), ensuring rated performance is achieved when installed according to manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance Ratings (AHRI #215447283)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Heating Capacity (HP @ 47°F)\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Furnace Fit\u003c\/td\u003e\n\u003ctd\u003eFlush-Fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA6010\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs \/ 198 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CHPEA4830C3\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eGas Furnace — GRVT961005CN\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28-7\/8\" x 34-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e143 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect Vent (Category IV) — 2\"-3\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eNatural Gas — Standard NOx emissions; verify local air quality district requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotentially eligible — consult IRS guidelines and a qualified tax professional for current 25C\/25D credit requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447283\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star (Heat Pump)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA6010):\u003c\/strong\u003e 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT961005CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRefer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884530958656,"sku":"GZV6SA6010-CHPEA4830C3-GRVT961005CN","price":8554.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-chpea6030d3-gdvt961005cn-ahri-215447268","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 Heat Pump + CHPEA6030D3 21\" Cabinet Height Horizontal Coil + GDVT961005CN 100,000 BTU Downflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447268) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GDVT961005CN 100,000 BTU\/h 96% AFUE gas furnace and the CHPEA6030D3 cased horizontal evaporator coil. Rated at 15.2 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V\/1Ph\/60Hz electrical. Dimensions: 37\" W x 12-5\/8\" D x 39\" H. Equipment Weight: 168 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e — 5-Ton R-32 Cased Horizontal Cased Evaporator Coil with EEV expansion device. Horizontal configuration. Cabinet Dimensions: 30\" W x 21\" D x 21\" H. Ship Weight: 76 lbs. Aluminum coil construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT961005CN\u003c\/strong\u003e — 100,000 BTU\/h Input (96,100 BTU\/h Output) 96% AFUE Two-Stage Natural Gas Gas Furnace. Variable-Speed ECM circulator blower motor. Downflow\/Horizontal configuration. Cabinet Dimensions: 21\" W x 28-7\/8\" D x 34-1\/2\" H. Direct Vent (Category IV) venting (2\"-3\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #c62828;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#c62828;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e The downflow\/horizontal furnace configuration with a horizontal coil requires precise ductwork transitions. The 21\" furnace cabinet mated to the 30\" wide CHPEA6030D3 horizontal coil may require adapter plates or field-fabricated transitions, especially in crawlspace or attic installations where access is limited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e In dual fuel mode, the system alternates between heat pump heating and gas furnace heating based on outdoor temperature. Verify the outdoor ambient temperature sensor is positioned away from direct sunlight, exhaust vents, and radiant heat sources. A sensor reading 5°F too high will cause premature gas furnace engagement, negating heat pump efficiency savings at moderate temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e After brazing the R-32 refrigerant connections, pressure test with dry nitrogen to 600 PSI and hold for 15 minutes. R-32 operates at slightly higher pressures than R-410A, making leak-tight connections critical. Document the standing pressure test result and evacuation micron reading on your commissioning checklist.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e This system uses R-32 (A2L, GWP 675), requiring compliance with ASHRAE 15 charge limits and local mechanical code provisions for mildly flammable refrigerants. EPA Section 608 certification is mandatory for handling R-32. Some jurisdictions may require additional training or certification specific to A2L refrigerants.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Combines 15.2 SEER2 \/ 8.2 HSPF2 heat pump performance with 96% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Airflow Management:\u003c\/strong\u003e The Variable-Speed ECM blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot\/cold spots and lowering operating noise compared to PSC motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Gas Valve:\u003c\/strong\u003e Two-stage gas valve operates at 70% capacity on low fire for most heating demand, reducing temperature swings and gas consumption while reserving full output for the coldest conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified Match:\u003c\/strong\u003e All components are AHRI-certified as a matched system (Certificate #215447268), ensuring rated performance is achieved when installed according to manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance Ratings (AHRI #215447268)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Heating Capacity (HP @ 47°F)\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Furnace Fit\u003c\/td\u003e\n\u003ctd\u003e1.75\" Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA6010\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs \/ 198 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CHPEA6030D3\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eGas Furnace — GDVT961005CN\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28-7\/8\" x 34-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e145 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect Vent (Category IV) — 2\"-3\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eNatural Gas — Standard NOx emissions; verify local air quality district requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotentially eligible — consult IRS guidelines and a qualified tax professional for current 25C\/25D credit requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447268\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star (Heat Pump)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA6010):\u003c\/strong\u003e 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GDVT961005CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRefer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884531155264,"sku":"GZV6SA6010-CHPEA6030D3-GDVT961005CN","price":8667.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-chpea6030d3-grvt961005cn-ahri-215447268","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 Heat Pump + CHPEA6030D3 21\" Cabinet Height Horizontal Coil + GRVT961005CN 100,000 BTU Downflow Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447268) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GRVT961005CN 100,000 BTU\/h 96% AFUE gas furnace and the CHPEA6030D3 cased horizontal evaporator coil. Rated at 15.2 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V\/1Ph\/60Hz electrical. Dimensions: 37\" W x 12-5\/8\" D x 39\" H. Equipment Weight: 168 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e — 5-Ton R-32 Cased Horizontal Cased Evaporator Coil with EEV expansion device. Horizontal configuration. Cabinet Dimensions: 30\" W x 21\" D x 21\" H. Ship Weight: 76 lbs. Aluminum coil construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961005CN\u003c\/strong\u003e — 100,000 BTU\/h Input (96,100 BTU\/h Output) 96% AFUE Two-Stage Natural Gas Gas Furnace. Variable-Speed ECM circulator blower motor. Downflow configuration. Cabinet Dimensions: 21\" W x 28-7\/8\" D x 34-1\/2\" H. Direct Vent (Category IV) venting (2\"-3\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #c62828;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#c62828;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Downflow furnace installations with this 100,000 BTU two-stage gas furnace require careful attention to combustion air routing and condensate management. In tight closet or garage applications, the 21\" cabinet width can create clearance conflicts with the R-32 refrigerant line connections on the CHPEA6030D3 evaporator coil above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e Verify the condensate trap is installed per manufacturer instructions and confirm the drain slope before startup. R-32 systems operating at higher discharge pressures than R-410A predecessors will produce more condensate at peak cooling. A failed drain in a downflow application means water damage to the heat exchanger and burner assembly — the most expensive callback in HVAC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manometer to confirm negative pressure in the combustion chamber during operation. Target -0.02\" to -0.10\" W.C. at the draft inducer outlet. Document this reading on the commissioning report alongside your micron gauge evacuation record (500 microns or below, held for 10 minutes minimum with R-32).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e This system uses R-32 refrigerant (GWP 675), which is classified as A2L (mildly flammable). Ensure compliance with ASHRAE 15 and local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions now require leak detection equipment for A2L installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Combines 15.2 SEER2 \/ 8.2 HSPF2 heat pump performance with 96% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Airflow Management:\u003c\/strong\u003e The Variable-Speed ECM blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot\/cold spots and lowering operating noise compared to PSC motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Gas Valve:\u003c\/strong\u003e Two-stage gas valve operates at 70% capacity on low fire for most heating demand, reducing temperature swings and gas consumption while reserving full output for the coldest conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified Match:\u003c\/strong\u003e All components are AHRI-certified as a matched system (Certificate #215447268), ensuring rated performance is achieved when installed according to manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance Ratings (AHRI #215447268)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Heating Capacity (HP @ 47°F)\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Furnace Fit\u003c\/td\u003e\n\u003ctd\u003e1.75\" Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA6010\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs \/ 198 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CHPEA6030D3\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eGas Furnace — GRVT961005CN\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28-7\/8\" x 34-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e143 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect Vent (Category IV) — 2\"-3\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eNatural Gas — Standard NOx emissions; verify local air quality district requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotentially eligible — consult IRS guidelines and a qualified tax professional for current 25C\/25D credit requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447268\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star (Heat Pump)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA6010):\u003c\/strong\u003e 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT961005CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRefer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884531515712,"sku":"GZV6SA6010-CHPEA6030D3-GRVT961005CN","price":8578.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-chpea4830d3-gdvt961005cn-ahri-215447283","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 Heat Pump + CHPEA4830D3 24-1\/2\" Cabinet Height Horizontal Coil + GDVT961005CN 100,000 BTU Downflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447283) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GDVT961005CN 100,000 BTU\/h 96% AFUE gas furnace and the CHPEA4830D3 cased horizontal evaporator coil. Rated at 15.2 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V\/1Ph\/60Hz electrical. Dimensions: 37\" W x 12-5\/8\" D x 39\" H. Equipment Weight: 168 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830D3\u003c\/strong\u003e — 4-Ton R-32 Cased Horizontal Cased Evaporator Coil with EEV expansion device. Horizontal configuration. Cabinet Dimensions: 30\" W x 21\" D x 24-1\/2\" H. Ship Weight: 78 lbs. Aluminum coil construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT961005CN\u003c\/strong\u003e — 100,000 BTU\/h Input (96,100 BTU\/h Output) 96% AFUE Two-Stage Natural Gas Gas Furnace. Variable-Speed ECM circulator blower motor. Downflow\/Horizontal configuration. Cabinet Dimensions: 21\" W x 28-7\/8\" D x 34-1\/2\" H. Direct Vent (Category IV) venting (2\"-3\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #c62828;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#c62828;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e The downflow\/horizontal furnace configuration with a horizontal coil requires precise ductwork transitions. The 21\" furnace cabinet mated to the 30\" wide CHPEA4830D3 horizontal coil may require adapter plates or field-fabricated transitions, especially in crawlspace or attic installations where access is limited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e In dual fuel mode, the system alternates between heat pump heating and gas furnace heating based on outdoor temperature. Verify the outdoor ambient temperature sensor is positioned away from direct sunlight, exhaust vents, and radiant heat sources. A sensor reading 5°F too high will cause premature gas furnace engagement, negating heat pump efficiency savings at moderate temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e After brazing the R-32 refrigerant connections, pressure test with dry nitrogen to 600 PSI and hold for 15 minutes. R-32 operates at slightly higher pressures than R-410A, making leak-tight connections critical. Document the standing pressure test result and evacuation micron reading on your commissioning checklist.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e This system uses R-32 (A2L, GWP 675), requiring compliance with ASHRAE 15 charge limits and local mechanical code provisions for mildly flammable refrigerants. EPA Section 608 certification is mandatory for handling R-32. Some jurisdictions may require additional training or certification specific to A2L refrigerants.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Combines 15.2 SEER2 \/ 8.2 HSPF2 heat pump performance with 96% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Airflow Management:\u003c\/strong\u003e The Variable-Speed ECM blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot\/cold spots and lowering operating noise compared to PSC motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Gas Valve:\u003c\/strong\u003e Two-stage gas valve operates at 70% capacity on low fire for most heating demand, reducing temperature swings and gas consumption while reserving full output for the coldest conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified Match:\u003c\/strong\u003e All components are AHRI-certified as a matched system (Certificate #215447283), ensuring rated performance is achieved when installed according to manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance Ratings (AHRI #215447283)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Heating Capacity (HP @ 47°F)\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Furnace Fit\u003c\/td\u003e\n\u003ctd\u003e1.75\" Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA6010\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs \/ 198 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CHPEA4830D3\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eGas Furnace — GDVT961005CN\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28-7\/8\" x 34-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e145 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect Vent (Category IV) — 2\"-3\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eNatural Gas — Standard NOx emissions; verify local air quality district requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotentially eligible — consult IRS guidelines and a qualified tax professional for current 25C\/25D credit requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447283\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star (Heat Pump)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA6010):\u003c\/strong\u003e 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GDVT961005CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRefer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884531548480,"sku":"GZV6SA6010-CHPEA4830D3-GDVT961005CN","price":8651.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-chpea4830c3-gdvt961005cn-ahri-215447283","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 Heat Pump + CHPEA4830C3 21\" Cabinet Height Horizontal Coil + GDVT961005CN 100,000 BTU Downflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447283) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GDVT961005CN 100,000 BTU\/h 96% AFUE gas furnace and the CHPEA4830C3 cased horizontal evaporator coil. Rated at 15.2 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V\/1Ph\/60Hz electrical. Dimensions: 37\" W x 12-5\/8\" D x 39\" H. Equipment Weight: 168 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830C3\u003c\/strong\u003e — 4-Ton R-32 Cased Horizontal Cased Evaporator Coil with EEV expansion device. Horizontal configuration. Cabinet Dimensions: 30\" W x 21\" D x 21\" H. Ship Weight: 76 lbs. Aluminum coil construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT961005CN\u003c\/strong\u003e — 100,000 BTU\/h Input (96,100 BTU\/h Output) 96% AFUE Two-Stage Natural Gas Gas Furnace. Variable-Speed ECM circulator blower motor. Downflow\/Horizontal configuration. Cabinet Dimensions: 21\" W x 28-7\/8\" D x 34-1\/2\" H. Direct Vent (Category IV) venting (2\"-3\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #c62828;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#c62828;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e The downflow\/horizontal furnace configuration with a horizontal coil requires precise ductwork transitions. The 21\" furnace cabinet mated to the 30\" wide CHPEA4830C3 horizontal coil may require adapter plates or field-fabricated transitions, especially in crawlspace or attic installations where access is limited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e In dual fuel mode, the system alternates between heat pump heating and gas furnace heating based on outdoor temperature. Verify the outdoor ambient temperature sensor is positioned away from direct sunlight, exhaust vents, and radiant heat sources. A sensor reading 5°F too high will cause premature gas furnace engagement, negating heat pump efficiency savings at moderate temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e After brazing the R-32 refrigerant connections, pressure test with dry nitrogen to 600 PSI and hold for 15 minutes. R-32 operates at slightly higher pressures than R-410A, making leak-tight connections critical. Document the standing pressure test result and evacuation micron reading on your commissioning checklist.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e This system uses R-32 (A2L, GWP 675), requiring compliance with ASHRAE 15 charge limits and local mechanical code provisions for mildly flammable refrigerants. EPA Section 608 certification is mandatory for handling R-32. Some jurisdictions may require additional training or certification specific to A2L refrigerants.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Combines 15.2 SEER2 \/ 8.2 HSPF2 heat pump performance with 96% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Airflow Management:\u003c\/strong\u003e The Variable-Speed ECM blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot\/cold spots and lowering operating noise compared to PSC motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Gas Valve:\u003c\/strong\u003e Two-stage gas valve operates at 70% capacity on low fire for most heating demand, reducing temperature swings and gas consumption while reserving full output for the coldest conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified Match:\u003c\/strong\u003e All components are AHRI-certified as a matched system (Certificate #215447283), ensuring rated performance is achieved when installed according to manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance Ratings (AHRI #215447283)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Heating Capacity (HP @ 47°F)\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Furnace Fit\u003c\/td\u003e\n\u003ctd\u003eFlush-Fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA6010\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs \/ 198 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CHPEA4830C3\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eGas Furnace — GDVT961005CN\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28-7\/8\" x 34-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e145 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect Vent (Category IV) — 2\"-3\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eNatural Gas — Standard NOx emissions; verify local air quality district requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotentially eligible — consult IRS guidelines and a qualified tax professional for current 25C\/25D credit requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447283\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star (Heat Pump)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA6010):\u003c\/strong\u003e 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GDVT961005CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRefer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884531646784,"sku":"GZV6SA6010-CHPEA4830C3-GDVT961005CN","price":8643.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-chpea4830d3-grvt961005cn-ahri-215447283","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 Heat Pump + CHPEA4830D3 24-1\/2\" Cabinet Height Horizontal Coil + GRVT961005CN 100,000 BTU Downflow Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447283) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GRVT961005CN 100,000 BTU\/h 96% AFUE gas furnace and the CHPEA4830D3 cased horizontal evaporator coil. Rated at 15.2 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V\/1Ph\/60Hz electrical. Dimensions: 37\" W x 12-5\/8\" D x 39\" H. Equipment Weight: 168 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830D3\u003c\/strong\u003e — 4-Ton R-32 Cased Horizontal Cased Evaporator Coil with EEV expansion device. Horizontal configuration. Cabinet Dimensions: 30\" W x 21\" D x 24-1\/2\" H. Ship Weight: 78 lbs. Aluminum coil construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961005CN\u003c\/strong\u003e — 100,000 BTU\/h Input (96,100 BTU\/h Output) 96% AFUE Two-Stage Natural Gas Gas Furnace. Variable-Speed ECM circulator blower motor. Downflow configuration. Cabinet Dimensions: 21\" W x 28-7\/8\" D x 34-1\/2\" H. Direct Vent (Category IV) venting (2\"-3\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #c62828;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#c62828;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Downflow furnace installations with this 100,000 BTU two-stage gas furnace require careful attention to combustion air routing and condensate management. In tight closet or garage applications, the 21\" cabinet width can create clearance conflicts with the R-32 refrigerant line connections on the CHPEA4830D3 evaporator coil above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e Verify the condensate trap is installed per manufacturer instructions and confirm the drain slope before startup. R-32 systems operating at higher discharge pressures than R-410A predecessors will produce more condensate at peak cooling. A failed drain in a downflow application means water damage to the heat exchanger and burner assembly — the most expensive callback in HVAC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manometer to confirm negative pressure in the combustion chamber during operation. Target -0.02\" to -0.10\" W.C. at the draft inducer outlet. Document this reading on the commissioning report alongside your micron gauge evacuation record (500 microns or below, held for 10 minutes minimum with R-32).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e This system uses R-32 refrigerant (GWP 675), which is classified as A2L (mildly flammable). Ensure compliance with ASHRAE 15 and local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions now require leak detection equipment for A2L installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Combines 15.2 SEER2 \/ 8.2 HSPF2 heat pump performance with 96% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Airflow Management:\u003c\/strong\u003e The Variable-Speed ECM blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot\/cold spots and lowering operating noise compared to PSC motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Gas Valve:\u003c\/strong\u003e Two-stage gas valve operates at 70% capacity on low fire for most heating demand, reducing temperature swings and gas consumption while reserving full output for the coldest conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified Match:\u003c\/strong\u003e All components are AHRI-certified as a matched system (Certificate #215447283), ensuring rated performance is achieved when installed according to manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance Ratings (AHRI #215447283)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Heating Capacity (HP @ 47°F)\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Furnace Fit\u003c\/td\u003e\n\u003ctd\u003e1.75\" Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA6010\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs \/ 198 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CHPEA4830D3\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eGas Furnace — GRVT961005CN\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28-7\/8\" x 34-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e143 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect Vent (Category IV) — 2\"-3\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eNatural Gas — Standard NOx emissions; verify local air quality district requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotentially eligible — consult IRS guidelines and a qualified tax professional for current 25C\/25D credit requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447283\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star (Heat Pump)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA6010):\u003c\/strong\u003e 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT961005CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRefer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884532105536,"sku":"GZV6SA6010-CHPEA4830D3-GRVT961005CN","price":8562.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-capea6030d3-gdvt961005cn-ahri-215447298","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 Heat Pump + CAPEA6030D3 24-1\/2\" Cabinet Width Upflow\/Downflow Coil + GDVT961005CN 100,000 BTU Downflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447298) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GDVT961005CN 100,000 BTU\/h 96% AFUE gas furnace and the CAPEA6030D3 cased upflow\/downflow evaporator coil. Rated at 15.2 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V\/1Ph\/60Hz electrical. Dimensions: 37\" W x 12-5\/8\" D x 39\" H. Equipment Weight: 168 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — 5-Ton R-32 Cased Upflow\/Downflow Cased Evaporator Coil with EEV expansion device. Upflow\/Downflow configuration. Cabinet Dimensions: 24-1\/2\" W x 21\" D x 30\" H. Ship Weight: 78 lbs. Aluminum coil construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT961005CN\u003c\/strong\u003e — 100,000 BTU\/h Input (96,100 BTU\/h Output) 96% AFUE Two-Stage Natural Gas Gas Furnace. Variable-Speed ECM circulator blower motor. Downflow\/Horizontal configuration. Cabinet Dimensions: 21\" W x 28-7\/8\" D x 34-1\/2\" H. Direct Vent (Category IV) venting (2\"-3\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #c62828;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#c62828;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e The downflow\/horizontal furnace configuration with a horizontal coil requires precise ductwork transitions. The 21\" furnace cabinet mated to the 24-1\/2\" wide CAPEA6030D3 horizontal coil may require adapter plates or field-fabricated transitions, especially in crawlspace or attic installations where access is limited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e In dual fuel mode, the system alternates between heat pump heating and gas furnace heating based on outdoor temperature. Verify the outdoor ambient temperature sensor is positioned away from direct sunlight, exhaust vents, and radiant heat sources. A sensor reading 5°F too high will cause premature gas furnace engagement, negating heat pump efficiency savings at moderate temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e After brazing the R-32 refrigerant connections, pressure test with dry nitrogen to 600 PSI and hold for 15 minutes. R-32 operates at slightly higher pressures than R-410A, making leak-tight connections critical. Document the standing pressure test result and evacuation micron reading on your commissioning checklist.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e This system uses R-32 (A2L, GWP 675), requiring compliance with ASHRAE 15 charge limits and local mechanical code provisions for mildly flammable refrigerants. EPA Section 608 certification is mandatory for handling R-32. Some jurisdictions may require additional training or certification specific to A2L refrigerants.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Combines 15.2 SEER2 \/ 8.2 HSPF2 heat pump performance with 96% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Airflow Management:\u003c\/strong\u003e The Variable-Speed ECM blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot\/cold spots and lowering operating noise compared to PSC motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Gas Valve:\u003c\/strong\u003e Two-stage gas valve operates at 70% capacity on low fire for most heating demand, reducing temperature swings and gas consumption while reserving full output for the coldest conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified Match:\u003c\/strong\u003e All components are AHRI-certified as a matched system (Certificate #215447298), ensuring rated performance is achieved when installed according to manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance Ratings (AHRI #215447298)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Heating Capacity (HP @ 47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Furnace Fit\u003c\/td\u003e\n\u003ctd\u003e1.75\" Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA6010\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs \/ 198 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CAPEA6030D3\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24-1\/2\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eGas Furnace — GDVT961005CN\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28-7\/8\" x 34-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e145 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect Vent (Category IV) — 2\"-3\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eNatural Gas — Standard NOx emissions; verify local air quality district requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotentially eligible — consult IRS guidelines and a qualified tax professional for current 25C\/25D credit requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447298\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star (Heat Pump)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA6010):\u003c\/strong\u003e 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GDVT961005CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRefer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884532367680,"sku":"GZV6SA6010-CAPEA6030D3-GDVT961005CN","price":8779.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-chpea6030d3-gcvm970804cn-ahri-215447278","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 Communicating Heat Pump + CHPEA6030D3 21\" Cabinet Height Horizontal Coil + GCVM970804CN 80,000 BTU Downflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447278) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GCVM970804CN 80,000 BTU\/h 97% AFUE gas furnace and the CHPEA6030D3 cased horizontal evaporator coil. Rated at 15.2 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. This configuration includes ComfortBridge communicating technology for enhanced system diagnostics and performance optimization. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V\/1Ph\/60Hz electrical. Dimensions: 37\" W x 12-5\/8\" D x 39\" H. Equipment Weight: 168 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e — 5-Ton R-32 Cased Horizontal Cased Evaporator Coil with EEV expansion device. Horizontal configuration. Cabinet Dimensions: 30\" W x 21\" D x 21\" H. Ship Weight: 76 lbs. Aluminum coil construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM970804CN\u003c\/strong\u003e — 80,000 BTU\/h Input (77,600 BTU\/h Output) 97% AFUE Modulating Natural Gas Gas Furnace. Variable-Speed ECM (ComfortBridge) circulator blower motor. Downflow\/Horizontal configuration. Cabinet Dimensions: 21\" W x 28-7\/8\" D x 34-1\/2\" H. Direct Vent (Category IV) venting (2\"-3\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #c62828;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#c62828;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e The downflow\/horizontal furnace configuration with a horizontal coil requires precise ductwork transitions. The 21\" furnace cabinet mated to the 30\" wide CHPEA6030D3 horizontal coil may require adapter plates or field-fabricated transitions, especially in crawlspace or attic installations where access is limited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e In dual fuel mode, the system alternates between heat pump heating and gas furnace heating based on outdoor temperature. Verify the outdoor ambient temperature sensor is positioned away from direct sunlight, exhaust vents, and radiant heat sources. A sensor reading 5°F too high will cause premature gas furnace engagement, negating heat pump efficiency savings at moderate temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e After brazing the R-32 refrigerant connections, pressure test with dry nitrogen to 600 PSI and hold for 15 minutes. R-32 operates at slightly higher pressures than R-410A, making leak-tight connections critical. Document the standing pressure test result and evacuation micron reading on your commissioning checklist.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e This system uses R-32 (A2L, GWP 675), requiring compliance with ASHRAE 15 charge limits and local mechanical code provisions for mildly flammable refrigerants. EPA Section 608 certification is mandatory for handling R-32. Some jurisdictions may require additional training or certification specific to A2L refrigerants.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Combines 15.2 SEER2 \/ 8.2 HSPF2 heat pump performance with 97% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Airflow Management:\u003c\/strong\u003e The Variable-Speed ECM (ComfortBridge) blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot\/cold spots and lowering operating noise compared to PSC motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModulating Gas Valve:\u003c\/strong\u003e Modulating gas valve adjusts flame output across a continuous range for maximum comfort and efficiency, eliminating the temperature swings associated with fixed-stage operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified Match:\u003c\/strong\u003e All components are AHRI-certified as a matched system (Certificate #215447278), ensuring rated performance is achieved when installed according to manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance Ratings (AHRI #215447278)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Heating Capacity (HP @ 47°F)\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Furnace Fit\u003c\/td\u003e\n\u003ctd\u003e1.75\" Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA6010\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs \/ 198 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CHPEA6030D3\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eGas Furnace — GCVM970804CN\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28-7\/8\" x 34-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e141 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect Vent (Category IV) — 2\"-3\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eNatural Gas — Standard NOx emissions; verify local air quality district requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotentially eligible — consult IRS guidelines and a qualified tax professional for current 25C\/25D credit requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star (Heat Pump)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA6010):\u003c\/strong\u003e 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GCVM970804CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRefer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884533514560,"sku":"GZV6SA6010-CHPEA6030D3-GCVM970804CN","price":8608.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/uutbtbbtbtbtubled.jpg?v=1777727051"},{"product_id":"goodman-gzv6sa6010-capea6030c3-gcvm970804cn-ahri-215447308","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 Communicating Heat Pump + CAPEA6030C3 21\" Cabinet Width Upflow\/Downflow Coil + GCVM970804CN 80,000 BTU Downflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447308) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GCVM970804CN 80,000 BTU\/h 97% AFUE gas furnace and the CAPEA6030C3 cased upflow\/downflow evaporator coil. Rated at 15.2 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. This configuration includes ComfortBridge communicating technology for enhanced system diagnostics and performance optimization. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V\/1Ph\/60Hz electrical. Dimensions: 37\" W x 12-5\/8\" D x 39\" H. Equipment Weight: 168 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — 5-Ton R-32 Cased Upflow\/Downflow Cased Evaporator Coil with EEV expansion device. Upflow\/Downflow configuration. Cabinet Dimensions: 21\" W x 21\" D x 30\" H. Ship Weight: 75 lbs. Aluminum coil construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM970804CN\u003c\/strong\u003e — 80,000 BTU\/h Input (77,600 BTU\/h Output) 97% AFUE Modulating Natural Gas Gas Furnace. Variable-Speed ECM (ComfortBridge) circulator blower motor. Downflow\/Horizontal configuration. Cabinet Dimensions: 21\" W x 28-7\/8\" D x 34-1\/2\" H. Direct Vent (Category IV) venting (2\"-3\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #c62828;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#c62828;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e The downflow\/horizontal furnace configuration with a horizontal coil requires precise ductwork transitions. The 21\" furnace cabinet mated to the 21\" wide CAPEA6030C3 horizontal coil may require adapter plates or field-fabricated transitions, especially in crawlspace or attic installations where access is limited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e In dual fuel mode, the system alternates between heat pump heating and gas furnace heating based on outdoor temperature. Verify the outdoor ambient temperature sensor is positioned away from direct sunlight, exhaust vents, and radiant heat sources. A sensor reading 5°F too high will cause premature gas furnace engagement, negating heat pump efficiency savings at moderate temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e After brazing the R-32 refrigerant connections, pressure test with dry nitrogen to 600 PSI and hold for 15 minutes. R-32 operates at slightly higher pressures than R-410A, making leak-tight connections critical. Document the standing pressure test result and evacuation micron reading on your commissioning checklist.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e This system uses R-32 (A2L, GWP 675), requiring compliance with ASHRAE 15 charge limits and local mechanical code provisions for mildly flammable refrigerants. EPA Section 608 certification is mandatory for handling R-32. Some jurisdictions may require additional training or certification specific to A2L refrigerants.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Combines 15.2 SEER2 \/ 8.2 HSPF2 heat pump performance with 97% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Airflow Management:\u003c\/strong\u003e The Variable-Speed ECM (ComfortBridge) blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot\/cold spots and lowering operating noise compared to PSC motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModulating Gas Valve:\u003c\/strong\u003e Modulating gas valve adjusts flame output across a continuous range for maximum comfort and efficiency, eliminating the temperature swings associated with fixed-stage operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified Match:\u003c\/strong\u003e All components are AHRI-certified as a matched system (Certificate #215447308), ensuring rated performance is achieved when installed according to manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance Ratings (AHRI #215447308)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Heating Capacity (HP @ 47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Furnace Fit\u003c\/td\u003e\n\u003ctd\u003eFlush-Fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA6010\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs \/ 198 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CAPEA6030C3\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eGas Furnace — GCVM970804CN\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28-7\/8\" x 34-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e141 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect Vent (Category IV) — 2\"-3\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eNatural Gas — Standard NOx emissions; verify local air quality district requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotentially eligible — consult IRS guidelines and a qualified tax professional for current 25C\/25D credit requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star (Heat Pump)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA6010):\u003c\/strong\u003e 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GCVM970804CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRefer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884533612864,"sku":"GZV6SA6010-CAPEA6030C3-GCVM970804CN","price":8710.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/uutbtbbtbtbtubled.jpg?v=1777727051"},{"product_id":"goodman-gzv6sa6010-chpea6030c3-gdvt961005cn-ahri-215447268","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 Heat Pump + CHPEA6030C3 24-1\/2\" Cabinet Height Horizontal Coil + GDVT961005CN 100,000 BTU Downflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447268) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GDVT961005CN 100,000 BTU\/h 96% AFUE gas furnace and the CHPEA6030C3 cased horizontal evaporator coil. Rated at 15.2 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V\/1Ph\/60Hz electrical. Dimensions: 37\" W x 12-5\/8\" D x 39\" H. Equipment Weight: 168 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030C3\u003c\/strong\u003e — 5-Ton R-32 Cased Horizontal Cased Evaporator Coil with EEV expansion device. Horizontal configuration. Cabinet Dimensions: 30\" W x 21\" D x 24-1\/2\" H. Ship Weight: 78 lbs. Aluminum coil construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT961005CN\u003c\/strong\u003e — 100,000 BTU\/h Input (96,100 BTU\/h Output) 96% AFUE Two-Stage Natural Gas Gas Furnace. Variable-Speed ECM circulator blower motor. Downflow\/Horizontal configuration. Cabinet Dimensions: 21\" W x 28-7\/8\" D x 34-1\/2\" H. Direct Vent (Category IV) venting (2\"-3\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #c62828;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#c62828;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e The downflow\/horizontal furnace configuration with a horizontal coil requires precise ductwork transitions. The 21\" furnace cabinet mated to the 30\" wide CHPEA6030C3 horizontal coil may require adapter plates or field-fabricated transitions, especially in crawlspace or attic installations where access is limited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e In dual fuel mode, the system alternates between heat pump heating and gas furnace heating based on outdoor temperature. Verify the outdoor ambient temperature sensor is positioned away from direct sunlight, exhaust vents, and radiant heat sources. A sensor reading 5°F too high will cause premature gas furnace engagement, negating heat pump efficiency savings at moderate temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e After brazing the R-32 refrigerant connections, pressure test with dry nitrogen to 600 PSI and hold for 15 minutes. R-32 operates at slightly higher pressures than R-410A, making leak-tight connections critical. Document the standing pressure test result and evacuation micron reading on your commissioning checklist.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e This system uses R-32 (A2L, GWP 675), requiring compliance with ASHRAE 15 charge limits and local mechanical code provisions for mildly flammable refrigerants. EPA Section 608 certification is mandatory for handling R-32. Some jurisdictions may require additional training or certification specific to A2L refrigerants.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Combines 15.2 SEER2 \/ 8.2 HSPF2 heat pump performance with 96% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Airflow Management:\u003c\/strong\u003e The Variable-Speed ECM blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot\/cold spots and lowering operating noise compared to PSC motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Gas Valve:\u003c\/strong\u003e Two-stage gas valve operates at 70% capacity on low fire for most heating demand, reducing temperature swings and gas consumption while reserving full output for the coldest conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified Match:\u003c\/strong\u003e All components are AHRI-certified as a matched system (Certificate #215447268), ensuring rated performance is achieved when installed according to manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance Ratings (AHRI #215447268)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Heating Capacity (HP @ 47°F)\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Furnace Fit\u003c\/td\u003e\n\u003ctd\u003eFlush-Fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA6010\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs \/ 198 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CHPEA6030C3\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eGas Furnace — GDVT961005CN\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28-7\/8\" x 34-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e145 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect Vent (Category IV) — 2\"-3\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eNatural Gas — Standard NOx emissions; verify local air quality district requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotentially eligible — consult IRS guidelines and a qualified tax professional for current 25C\/25D credit requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447268\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star (Heat Pump)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA6010):\u003c\/strong\u003e 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GDVT961005CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRefer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884533776704,"sku":"GZV6SA6010-CHPEA6030C3-GDVT961005CN","price":8659.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-capea6030c3-gdvt961005cn-ahri-215447298","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 Heat Pump + CAPEA6030C3 21\" Cabinet Width Upflow\/Downflow Coil + GDVT961005CN 100,000 BTU Downflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447298) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GDVT961005CN 100,000 BTU\/h 96% AFUE gas furnace and the CAPEA6030C3 cased upflow\/downflow evaporator coil. Rated at 15.2 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V\/1Ph\/60Hz electrical. Dimensions: 37\" W x 12-5\/8\" D x 39\" H. Equipment Weight: 168 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — 5-Ton R-32 Cased Upflow\/Downflow Cased Evaporator Coil with EEV expansion device. Upflow\/Downflow configuration. Cabinet Dimensions: 21\" W x 21\" D x 30\" H. Ship Weight: 75 lbs. Aluminum coil construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT961005CN\u003c\/strong\u003e — 100,000 BTU\/h Input (96,100 BTU\/h Output) 96% AFUE Two-Stage Natural Gas Gas Furnace. Variable-Speed ECM circulator blower motor. Downflow\/Horizontal configuration. Cabinet Dimensions: 21\" W x 28-7\/8\" D x 34-1\/2\" H. Direct Vent (Category IV) venting (2\"-3\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #c62828;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#c62828;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e The downflow\/horizontal furnace configuration with a horizontal coil requires precise ductwork transitions. The 21\" furnace cabinet mated to the 21\" wide CAPEA6030C3 horizontal coil may require adapter plates or field-fabricated transitions, especially in crawlspace or attic installations where access is limited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e In dual fuel mode, the system alternates between heat pump heating and gas furnace heating based on outdoor temperature. Verify the outdoor ambient temperature sensor is positioned away from direct sunlight, exhaust vents, and radiant heat sources. A sensor reading 5°F too high will cause premature gas furnace engagement, negating heat pump efficiency savings at moderate temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e After brazing the R-32 refrigerant connections, pressure test with dry nitrogen to 600 PSI and hold for 15 minutes. R-32 operates at slightly higher pressures than R-410A, making leak-tight connections critical. Document the standing pressure test result and evacuation micron reading on your commissioning checklist.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e This system uses R-32 (A2L, GWP 675), requiring compliance with ASHRAE 15 charge limits and local mechanical code provisions for mildly flammable refrigerants. EPA Section 608 certification is mandatory for handling R-32. Some jurisdictions may require additional training or certification specific to A2L refrigerants.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Combines 15.2 SEER2 \/ 8.2 HSPF2 heat pump performance with 96% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Airflow Management:\u003c\/strong\u003e The Variable-Speed ECM blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot\/cold spots and lowering operating noise compared to PSC motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Gas Valve:\u003c\/strong\u003e Two-stage gas valve operates at 70% capacity on low fire for most heating demand, reducing temperature swings and gas consumption while reserving full output for the coldest conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified Match:\u003c\/strong\u003e All components are AHRI-certified as a matched system (Certificate #215447298), ensuring rated performance is achieved when installed according to manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance Ratings (AHRI #215447298)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Heating Capacity (HP @ 47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Furnace Fit\u003c\/td\u003e\n\u003ctd\u003eFlush-Fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA6010\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs \/ 198 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CAPEA6030C3\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eGas Furnace — GDVT961005CN\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28-7\/8\" x 34-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e145 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect Vent (Category IV) — 2\"-3\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eNatural Gas — Standard NOx emissions; verify local air quality district requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotentially eligible — consult IRS guidelines and a qualified tax professional for current 25C\/25D credit requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447298\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star (Heat Pump)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA6010):\u003c\/strong\u003e 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GDVT961005CN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRefer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884533875008,"sku":"GZV6SA6010-CAPEA6030C3-GDVT961005CN","price":8769.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gcvm970804cn-chpea4830d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GCVM970804CN | CHPEA4830D3 | Communicating | 24½\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Downflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447293) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GCVM970804CN 97% AFUE gas furnace and CHPEA4830D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Downflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830D3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 24½\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447293), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447293\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GCVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA4830D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GCVM970804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884534628672,"sku":"GZV6SA6010-GCVM970804CN-CHPEA4830D3","price":8592.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/uutbtbbtbtbtubled.jpg?v=1777727051"},{"product_id":"goodman-gzv6sa6010-gmvm970804cn-capea6030c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GMVM970804CN | CAPEA6030C3 | Communicating | 21\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU | Upflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447308) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GMVM970804CN 97% AFUE gas furnace and CAPEA6030C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased Evaporator Coil with EEV (21\" W x 21\" D x 30\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.3 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447308), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GMVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVM970804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884534661440,"sku":"GZV6SA6010-GMVM970804CN-CAPEA6030C3","price":8482.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gmvm970804cn-chpea4830d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GMVM970804CN | CHPEA4830D3 | Communicating | 24½\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447293) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GMVM970804CN 97% AFUE gas furnace and CHPEA4830D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830D3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 24½\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447293), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447293\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GMVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA4830D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVM970804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884534759744,"sku":"GZV6SA6010-GMVM970804CN-CHPEA4830D3","price":8364.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-grvs960805cu-chpea4830c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVS960805CU | CHPEA4830C3 | 21\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Single-Stage | Variable-Speed ECM | Ultra-Low NOx | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447289) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVS960805CU 96% AFUE gas furnace and CHPEA4830C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVS960805CU\u003c\/strong\u003e — Goodman 80,000 BTU\/h 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Ultra-Low NOx)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830C3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 21\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447289), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447289\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVS960805CU\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA4830C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eUltra-Low NOx (≤14 ng\/J) — meets South Coast AQMD Rule 1111 and Bay Area AQMD requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVS960805CU):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884534825280,"sku":"GZV6SA6010-GRVS960805CU-CHPEA4830C3","price":9085.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-grvm970804cn-chpea6030c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVM970804CN | CHPEA6030C3 | 24½\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447278) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVM970804CN 97% AFUE gas furnace and CHPEA6030C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030C3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 24½\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447278), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVM970804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884534923584,"sku":"GZV6SA6010-GRVM970804CN-CHPEA6030C3","price":8657.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-grvm970804cn-chpea6030d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVM970804CN | CHPEA6030D3 | 21\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447278) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVM970804CN 97% AFUE gas furnace and CHPEA6030D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 21\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447278), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVM970804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884535087424,"sku":"GZV6SA6010-GRVM970804CN-CHPEA6030D3","price":8665.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-grvs960805cu-chpea6030d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVS960805CU | CHPEA6030D3 | 21\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Single-Stage | Variable-Speed ECM | Ultra-Low NOx | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447274) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVS960805CU 96% AFUE gas furnace and CHPEA6030D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVS960805CU\u003c\/strong\u003e — Goodman 80,000 BTU\/h 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Ultra-Low NOx)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 21\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447274), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447274\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVS960805CU\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eUltra-Low NOx (≤14 ng\/J) — meets South Coast AQMD Rule 1111 and Bay Area AQMD requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVS960805CU):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884535185728,"sku":"GZV6SA6010-GRVS960805CU-CHPEA6030D3","price":9109.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gmvm970804cn-chpea4830c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GMVM970804CN | CHPEA4830C3 | Communicating | 21\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447293) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GMVM970804CN 97% AFUE gas furnace and CHPEA4830C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830C3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 21\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447293), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447293\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GMVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA4830C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVM970804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884535284032,"sku":"GZV6SA6010-GMVM970804CN-CHPEA4830C3","price":8356.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gcvm970804cn-chpea4830c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GCVM970804CN | CHPEA4830C3 | Communicating | 21\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Downflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447293) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GCVM970804CN 97% AFUE gas furnace and CHPEA4830C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Downflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830C3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 21\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447293), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447293\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GCVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA4830C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GCVM970804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884535382336,"sku":"GZV6SA6010-GCVM970804CN-CHPEA4830C3","price":8584.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/uutbtbbtbtbtubled.jpg?v=1777727051"},{"product_id":"goodman-gzv6sa6010-grvs960805cu-capea6030d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVS960805CU | CAPEA6030D3 | 24½\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU | Upflow\/Horizontal | Single-Stage | Variable-Speed ECM | Ultra-Low NOx | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447304) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVS960805CU 96% AFUE gas furnace and CAPEA6030D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVS960805CU\u003c\/strong\u003e — Goodman 80,000 BTU\/h 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Ultra-Low NOx)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased Evaporator Coil with EEV (24½\" W x 21\" D x 30\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.3 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447304), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVS960805CU\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eUltra-Low NOx (≤14 ng\/J) — meets South Coast AQMD Rule 1111 and Bay Area AQMD requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVS960805CU):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884535447872,"sku":"GZV6SA6010-GRVS960805CU-CAPEA6030D3","price":9221.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gmvs960805cu-chpea6030d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GMVS960805CU | CHPEA6030D3 | Communicating | 21\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Single-Stage | Variable-Speed ECM | Ultra-Low NOx | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447274) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GMVS960805CU 96% AFUE gas furnace and CHPEA6030D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVS960805CU\u003c\/strong\u003e — Goodman 80,000 BTU\/h 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Ultra-Low NOx)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 21\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447274), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447274\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GMVS960805CU\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eUltra-Low NOx (≤14 ng\/J) — meets South Coast AQMD Rule 1111 and Bay Area AQMD requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVS960805CU):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884535677248,"sku":"GZV6SA6010-GMVS960805CU-CHPEA6030D3","price":9026.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-grvs960805cu-capea6030c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVS960805CU | CAPEA6030C3 | 21\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU | Upflow\/Horizontal | Single-Stage | Variable-Speed ECM | Ultra-Low NOx | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447304) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVS960805CU 96% AFUE gas furnace and CAPEA6030C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVS960805CU\u003c\/strong\u003e — Goodman 80,000 BTU\/h 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Ultra-Low NOx)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased Evaporator Coil with EEV (21\" W x 21\" D x 30\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.3 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447304), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVS960805CU\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eUltra-Low NOx (≤14 ng\/J) — meets South Coast AQMD Rule 1111 and Bay Area AQMD requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVS960805CU):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884535775552,"sku":"GZV6SA6010-GRVS960805CU-CAPEA6030C3","price":9211.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-grvm970804cn-capea6030d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVM970804CN | CAPEA6030D3 | 24½\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU | Upflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447308) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVM970804CN 97% AFUE gas furnace and CAPEA6030D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased Evaporator Coil with EEV (24½\" W x 21\" D x 30\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.3 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447308), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVM970804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884535841088,"sku":"GZV6SA6010-GRVM970804CN-CAPEA6030D3","price":8777.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gcvm970804cn-capea6030d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GCVM970804CN | CAPEA6030D3 | Communicating | 24½\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU | Downflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447308) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GCVM970804CN 97% AFUE gas furnace and CAPEA6030D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Downflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased Evaporator Coil with EEV (24½\" W x 21\" D x 30\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.3 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447308), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GCVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GCVM970804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884535873856,"sku":"GZV6SA6010-GCVM970804CN-CAPEA6030D3","price":8720.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/uutbtbbtbtbtubled.jpg?v=1777727051"},{"product_id":"goodman-gzv6sa6010-gmvs960805cu-chpea4830c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GMVS960805CU | CHPEA4830C3 | Communicating | 21\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Single-Stage | Variable-Speed ECM | Ultra-Low NOx | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447289) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GMVS960805CU 96% AFUE gas furnace and CHPEA4830C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVS960805CU\u003c\/strong\u003e — Goodman 80,000 BTU\/h 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Ultra-Low NOx)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830C3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 21\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447289), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447289\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GMVS960805CU\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA4830C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eUltra-Low NOx (≤14 ng\/J) — meets South Coast AQMD Rule 1111 and Bay Area AQMD requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVS960805CU):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884536037696,"sku":"GZV6SA6010-GMVS960805CU-CHPEA4830C3","price":9002.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-grvt961005cn-chpea6030c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVT961005CN | CHPEA6030C3 | 24½\" Cabinet Height | Horizontal | Coil | 100,000 BTU | Upflow\/Horizontal | Two-Stage | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447268) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVT961005CN 96% AFUE gas furnace and CHPEA6030C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 100,000 BTU\/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961005CN\u003c\/strong\u003e — Goodman 100,000 BTU\/h 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030C3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 24½\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447268), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447268\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVT961005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e100,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT961005CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884536070464,"sku":"GZV6SA6010-GRVT961005CN-CHPEA6030C3","price":8570.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gmvs960805cu-chpea6030c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GMVS960805CU | CHPEA6030C3 | Communicating | 24½\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Single-Stage | Variable-Speed ECM | Ultra-Low NOx | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447274) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GMVS960805CU 96% AFUE gas furnace and CHPEA6030C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVS960805CU\u003c\/strong\u003e — Goodman 80,000 BTU\/h 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Ultra-Low NOx)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030C3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 24½\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447274), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447274\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GMVS960805CU\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eUltra-Low NOx (≤14 ng\/J) — meets South Coast AQMD Rule 1111 and Bay Area AQMD requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVS960805CU):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884536103232,"sku":"GZV6SA6010-GMVS960805CU-CHPEA6030C3","price":9018.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gmvs960805cu-chpea4830d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GMVS960805CU | CHPEA4830D3 | Communicating | 24½\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Single-Stage | Variable-Speed ECM | Ultra-Low NOx | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447289) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GMVS960805CU 96% AFUE gas furnace and CHPEA4830D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVS960805CU\u003c\/strong\u003e — Goodman 80,000 BTU\/h 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Ultra-Low NOx)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830D3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 24½\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447289), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447289\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GMVS960805CU\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA4830D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eUltra-Low NOx (≤14 ng\/J) — meets South Coast AQMD Rule 1111 and Bay Area AQMD requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVS960805CU):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884536234304,"sku":"GZV6SA6010-GMVS960805CU-CHPEA4830D3","price":9010.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gcvm971005cn-chpea6030d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GCVM971005CN | CHPEA6030D3 | Communicating | 21\" Cabinet Height | Horizontal | Coil | 100,000 BTU | Downflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447277) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GCVM971005CN 97% AFUE gas furnace and CHPEA6030D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 100,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM971005CN\u003c\/strong\u003e — Goodman 100,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Downflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 21\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447277), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GCVM971005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e100,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GCVM971005CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884536332608,"sku":"GZV6SA6010-GCVM971005CN-CHPEA6030D3","price":8749.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/uutbtbbtbtbtubled.jpg?v=1777727051"},{"product_id":"goodman-gzv6sa6010-grvm970804cn-chpea4830d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVM970804CN | CHPEA4830D3 | 24½\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447293) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVM970804CN 97% AFUE gas furnace and CHPEA4830D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830D3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 24½\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447293), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447293\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA4830D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVM970804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884536365376,"sku":"GZV6SA6010-GRVM970804CN-CHPEA4830D3","price":8649.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-grvt960804cn-chpea6030c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVT960804CN | CHPEA6030C3 | 24½\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Two-Stage | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447269) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVT960804CN 96% AFUE gas furnace and CHPEA6030C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT960804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030C3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 24½\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447269), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447269\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVT960804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT960804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884536430912,"sku":"GZV6SA6010-GRVT960804CN-CHPEA6030C3","price":8316.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gmvm970804cn-capea6030d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GMVM970804CN | CAPEA6030D3 | Communicating | 24½\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU | Upflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447308) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GMVM970804CN 97% AFUE gas furnace and CAPEA6030D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased Evaporator Coil with EEV (24½\" W x 21\" D x 30\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.3 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447308), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GMVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVM970804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884536463680,"sku":"GZV6SA6010-GMVM970804CN-CAPEA6030D3","price":8492.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-grvm970804cn-chpea4830c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVM970804CN | CHPEA4830C3 | 21\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447293) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVM970804CN 97% AFUE gas furnace and CHPEA4830C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830C3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 21\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447293), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447293\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA4830C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVM970804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884536529216,"sku":"GZV6SA6010-GRVM970804CN-CHPEA4830C3","price":8641.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gcvm970804cn-chpea6030c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GCVM970804CN | CHPEA6030C3 | Communicating | 24½\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Downflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447278) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GCVM970804CN 97% AFUE gas furnace and CHPEA6030C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Downflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030C3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 24½\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447278), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GCVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GCVM970804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884536594752,"sku":"GZV6SA6010-GCVM970804CN-CHPEA6030C3","price":8600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/uutbtbbtbtbtubled.jpg?v=1777727051"},{"product_id":"goodman-gzv6sa6010-grvt961005cn-capea6030c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVT961005CN | CAPEA6030C3 | 21\" Cabinet Width | Upflow\/Downflow | Coil | 100,000 BTU | Upflow\/Horizontal | Two-Stage | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447298) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVT961005CN 96% AFUE gas furnace and CAPEA6030C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 100,000 BTU\/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961005CN\u003c\/strong\u003e — Goodman 100,000 BTU\/h 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased Evaporator Coil with EEV (21\" W x 21\" D x 30\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.3 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447298), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447298\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVT961005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e100,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT961005CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884536627520,"sku":"GZV6SA6010-GRVT961005CN-CAPEA6030C3","price":8680.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gmvm971005cn-chpea6030d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GMVM971005CN | CHPEA6030D3 | Communicating | 21\" Cabinet Height | Horizontal | Coil | 100,000 BTU | Upflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447277) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GMVM971005CN 97% AFUE gas furnace and CHPEA6030D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 100,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM971005CN\u003c\/strong\u003e — Goodman 100,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 21\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447277), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GMVM971005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e100,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVM971005CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884536693056,"sku":"GZV6SA6010-GMVM971005CN-CHPEA6030D3","price":8622.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-grvt960804cn-capea6030c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVT960804CN | CAPEA6030C3 | 21\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU | Upflow\/Horizontal | Two-Stage | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447299) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVT960804CN 96% AFUE gas furnace and CAPEA6030C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT960804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased Evaporator Coil with EEV (21\" W x 21\" D x 30\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.3 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447299), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447299\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVT960804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT960804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884536791360,"sku":"GZV6SA6010-GRVT960804CN-CAPEA6030C3","price":8426.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gmvs960805cu-capea6030c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GMVS960805CU | CAPEA6030C3 | Communicating | 21\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU | Upflow\/Horizontal | Single-Stage | Variable-Speed ECM | Ultra-Low NOx | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447304) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GMVS960805CU 96% AFUE gas furnace and CAPEA6030C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVS960805CU\u003c\/strong\u003e — Goodman 80,000 BTU\/h 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Ultra-Low NOx)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased Evaporator Coil with EEV (21\" W x 21\" D x 30\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.3 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447304), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GMVS960805CU\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eUltra-Low NOx (≤14 ng\/J) — meets South Coast AQMD Rule 1111 and Bay Area AQMD requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVS960805CU):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884536856896,"sku":"GZV6SA6010-GMVS960805CU-CAPEA6030C3","price":9128.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-grvm971005cn-chpea6030c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVM971005CN | CHPEA6030C3 | 24½\" Cabinet Height | Horizontal | Coil | 100,000 BTU | Upflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447277) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVM971005CN 97% AFUE gas furnace and CHPEA6030C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 100,000 BTU\/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM971005CN\u003c\/strong\u003e — Goodman 100,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030C3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 24½\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447277), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVM971005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e100,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVM971005CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884536955200,"sku":"GZV6SA6010-GRVM971005CN-CHPEA6030C3","price":8923.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-grvt960804cn-chpea6030d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GRVT960804CN | CHPEA6030D3 | 21\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Two-Stage | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447269) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GRVT960804CN 96% AFUE gas furnace and CHPEA6030D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This system operates in standard (non-communicating) mode.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT960804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 21\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447269), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447269\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVT960804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT960804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884537020736,"sku":"GZV6SA6010-GRVT960804CN-CHPEA6030D3","price":8324.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gmvm970804cn-chpea6030d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GMVM970804CN | CHPEA6030D3 | Communicating | 21\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447278) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GMVM970804CN 97% AFUE gas furnace and CHPEA6030D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 21\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447278), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GMVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVM970804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884537119040,"sku":"GZV6SA6010-GMVM970804CN-CHPEA6030D3","price":8380.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gcvm971005cn-capea6030c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GCVM971005CN | CAPEA6030C3 | Communicating | 21\" Cabinet Width | Upflow\/Downflow | Coil | 100,000 BTU | Downflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447307) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GCVM971005CN 97% AFUE gas furnace and CAPEA6030C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 100,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM971005CN\u003c\/strong\u003e — Goodman 100,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Downflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased Evaporator Coil with EEV (21\" W x 21\" D x 30\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.3 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447307), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447307\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GCVM971005CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e100,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GCVM971005CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884537250112,"sku":"GZV6SA6010-GCVM971005CN-CAPEA6030C3","price":8851.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/uutbtbbtbtbtubled.jpg?v=1777727051"},{"product_id":"goodman-gzv6sa6010-gmvs960805cu-capea6030d3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GMVS960805CU | CAPEA6030D3 | Communicating | 24½\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU | Upflow\/Horizontal | Single-Stage | Variable-Speed ECM | Ultra-Low NOx | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447304) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GMVS960805CU 96% AFUE gas furnace and CAPEA6030D3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVS960805CU\u003c\/strong\u003e — Goodman 80,000 BTU\/h 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Ultra-Low NOx)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased Evaporator Coil with EEV (24½\" W x 21\" D x 30\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.3 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447304), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GMVS960805CU\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CAPEA6030D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eUltra-Low NOx (≤14 ng\/J) — meets South Coast AQMD Rule 1111 and Bay Area AQMD requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVS960805CU):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884537282880,"sku":"GZV6SA6010-GMVS960805CU-CAPEA6030D3","price":9138.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"},{"product_id":"goodman-gzv6sa6010-gmvm970804cn-chpea6030c3","title":"Goodman 5 Ton 15.2 SEER2 R-32 Dual Fuel System | GZV6SA6010 | GMVM970804CN | CHPEA6030C3 | Communicating | 24½\" Cabinet Height | Horizontal | Coil | 80,000 BTU | Upflow\/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace","description":"\u003ch2\u003eGoodman 5 Ton 15.2 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447278) pairs the Goodman GZV6SA6010 variable-speed heat pump condenser with the GMVM970804CN 97% AFUE gas furnace and CHPEA6030C3 evaporator coil. The system uses R-32 refrigerant with a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A — and achieves up to 15.2 SEER2 and 8.2 HSPF2 ratings. The outdoor unit delivers up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F, while the gas furnace provides up to 80,000 BTU\/h input for supplemental and emergency heating. This is a fully communicating system — the outdoor unit, indoor coil, and furnace communicate via two-wire connection for optimized performance and advanced diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM970804CN\u003c\/strong\u003e — Goodman 80,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Gas Furnace (Upflow\/Horizontal, 21\" Cabinet, Natural Gas)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030C3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with EEV (30\" W x 21\" D x 24½\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel changeover calibration between heat pump and gas furnace demands precision. If the balance point is set incorrectly, the system will short-cycle between modes, increasing component wear and creating uneven temperatures — especially in shoulder seasons when outdoor temps hover near the switchover threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e During commissioning, verify the balance point setting matches the regional heating design temperature. On R-32 systems with variable-speed compressors, the heat pump can operate efficiently to lower ambient temperatures than legacy R-410A systems. Setting the balance point 5–10°F lower than traditional defaults can reduce gas consumption by 15–25% over a heating season while keeping the home comfortable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 (up to 750 PSI high-side) and verify subcooling at 9±1°F per manufacturer specification. Confirm communicating mode handshake between the outdoor unit, indoor coil, and thermostat using the onboard 7-segment LED diagnostic display. Document all readings with a timestamped commissioning report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Ensure compliance with local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions adopting the 2024 UMC or IMC now require R-32-rated leak detection in mechanical rooms. Verify EPA Section 608 certification covers A2L handling before charging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 15.2 SEER2 \/ 8.2 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215447278), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Versatility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace heating based on outdoor temperature and balance point settings. This maximizes efficiency by using the heat pump during moderate weather and gas heating only when it is more cost-effective at lower temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Integration:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit, indoor coil, and furnace enables advanced diagnostics, automatic configuration, fault code storage, and optimized staging for maximum comfort and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GMVM970804CN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput BTU\/h\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28⅞\" x 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e2\" - 3\" PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA6030C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility with a qualified tax professional based on installed SEER2\/HSPF2 ratings and current IRS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas (≥40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVM970804CN):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Heat exchanger warranty: if the heat exchanger fails within 10 years (registered), Goodman will furnish a new equivalent unit. The heat exchanger itself is covered for up to 20 years (replacement heat exchanger), and up to 99 years (one-time replacement), when properly registered. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration within 60 days, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884537381184,"sku":"GZV6SA6010-GMVM970804CN-CHPEA6030C3","price":8372.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651"}],"url":"https:\/\/minisplitsystemsdirect.com\/collections\/goodman-5-ton-systems-15-2-seer2.oembed?page=4","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}