{"product_id":"140-000-btu-96-afue-single-stage-multi-positional-aciq-gas-furnace","title":"ACiQ 96% 140,000 BTU Single Stage Gas Furnace - 24.5\" Width - Multi-Positional","description":"\u003ch3\u003e\u003cstrong\u003eACiQ 96% 140,000 BTU Single Stage Gas Furnace - 24.5\" Width - Multi-Positional\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh efficient furnace\u003c\/li\u003e\n\u003cli\u003eCan be installed in uplfow, downflow, or horizontal applications\u003c\/li\u003e\n\u003cli\u003eSingle stage burner\u003c\/li\u003e\n\u003cli\u003eMulti speed electrically controlled blower motor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDesigned to be a high-efficiency furnace, the ACiQ N96MSN1402422A is a money saving unit to provide heating throughout even the coldest months of the year. With its multi-positional design, this unit is a good all-around choice for nearly any application.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eQuick Facts\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e140,000 BTU, 96% AFUE natural gas furnace\u003c\/li\u003e\n\u003cli\u003eGenerally suitable for up to a large house in ideal applications\u003c\/li\u003e\n\u003cli\u003eMulti-positional design - can be installed in the upflow, downflow, or horizontal orientations\u003c\/li\u003e\n\u003cli\u003eSingle stage burner with a multi-speed blower\u003c\/li\u003e\n\u003cli\u003eField-convertible to propane with an optional LP kit\u003c\/li\u003e\n\u003cli\u003eOn board self-diagnostics\u003c\/li\u003e\n\u003cli\u003eEnergy Star certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e140,000 BTU, 96% AFUE\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ACiQ N96MSN1402422A has an input of 140,000 BTU. With an efficiency of 96%, this means that the furnace has an output of 134,400 BTU. The 96% AFUE also means that for the gas going into the furnace, 96% of it is used to heat your home while only 4% is lost out of the flue piping and lost to normal furnace operations. All furnaces at this efficiency (90% and above) requires plastic\/PVC flue venting, and if metal flue venting is required for your installation, an 80% efficient furnace would be needed instead. While this unit uses natural gas as fuel out of the box, we also have an LP conversion kit, available at an additional cost. \u003cstrong\u003ePlease note that this furnace is not Low NOx or Ultra Low NOx compliant and if shipped to California may be subject to a mitigation fee.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eACiQ offers a standard 10 year parts warranty and lifetime (20 year) heat exchanger limited warranty. Please note that in order for these warranties to be upheld, installation following your state and local codes are required, along with timely registration through the manufacturer.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Durability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWith its ability to be installed in any configuration - upflow, downflow, or horizontal - the ACiQ N96MSN1402422A is very versatile in application potential. The unit has a durable outer casing that can withstand wear-and-tear through its entire lifetime, providing the peace of mind that your home will stay comfortable year-round. Please note that this furnace is not intended for use in a mobile home on its own.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 388.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eSKU    \u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003e\n\u003cspan\u003eN96MSN1402422A\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eWeight (in lbs)    \u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003e179.000000\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eAHRI Certificate Number    \u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003e213148528\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eBrand\/Manufacturer    \u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003eACiQ\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eReplaces    \u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003eN95ESN1402422A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 35.6px;\"\u003eEquivalent    \u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 35.6px;\"\u003eCarrier Equivalent: 59SC6A140M24--22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eProduct Features    \u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003eNew Refrigerant Compliant\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eFurnace Efficiency \/ AFUE    \u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003e96%\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eHeating BTU    \u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003e140,000\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eBlower Motor    \u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003eECM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eMaximum CFM    \u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003e2105\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003eUpflow\/Downflow\/Horizontal\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eEnergy Star    \u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003eYes\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eBurner Stages    \u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003eSingle\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eFuel Type    \u003c\/td\u003e\n\u003ctd data-th=\"Fuel Type\" class=\"col data\" style=\"width: 67.2126%; height: 19.6px;\"\u003ePropane, Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003e35\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eWidth    \u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003e24.5\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eDepth    \u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003e29 1\/2\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 32.602%; height: 19.6px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%; height: 19.6px;\"\u003e10 Years with Online Registration\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.602%;\"\u003eResources    \u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACiQ%20N96MS%20Product%20Specifications.pdf\"\u003eACiQ Product Specifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACiQ%20N96MS%20Catalog.pdf\"\u003eACiQ Catalog\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACiQ%20N96MS%20Warranty.pdf\"\u003eACiQ Warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACiQ%20N96MS%20Installation%20Manual.pdf\"\u003eACiQ Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.602%;\"\u003eSafety Information    \u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 67.2126%;\"\u003e\n\u003cp\u003eThis gas appliance requires a trained technician to install. Improperly connecting gas lines or improperly connecting a gas flue or venting may result in death. By purchasing this item, you are agreeing that you are using a trained technician to install this gas appliance. We will not be responsible for any injury or property damage arising from improper service or service procedures. Whoever installs or services this unit assumes responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install this equipment.\u003c\/p\u003e\n\u003cp\u003ePROPOSITION 65 WARNING\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ACiQ","offers":[{"title":"Default Title","offer_id":50640873914688,"sku":"N96MSN1402422A","price":2050.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/ACiQ-96-140-000-BTU-Single-Stage-Gas-Furnace-24-5-Width-Multi-Positional-N96MSN1402422A-Mini-Split-Systems-Direct-40689626349888.jpg?v=1768988030","url":"https:\/\/minisplitsystemsdirect.com\/products\/140-000-btu-96-afue-single-stage-multi-positional-aciq-gas-furnace","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}