{"product_id":"aciq-extreme-series-5-ton-17-5-seer2-high-efficiency-heat-pump-split-system-r454b-inverter-multi-positional","title":"ACiQ Extreme+ Series 5 Ton 17.5 SEER2 High Efficiency Heat Pump Split System - R454B Inverter - Multi-Positional","description":"\u003ch3\u003e\n\u003cstrong\u003eACiQ Extreme+ Series 5 Ton 17.5 SEER2 High Efficiency Heat Pump Split System - R454B Inverter - Multi-Positional\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eACiQ's Extreme+ heat pump systems provide a level of comfort that is rivaled by none - a high-performance, self-adjusting, mini-split-style inverter condenser matched to a communicating air handler that will attach seamlessly to your existing ductwork for easy installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete all-electric heating and cooling system\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePre-charged with R454B refrigerant\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHigh efficiency inverter technology reduces energy bills\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCan be installed in upflow, downflow, or horizontal applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eWell-suited for large homes in various climates\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHyper heat to provide efficient heat down to -22°F\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHow is it different from other heat pumps?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTraditional heat pumps rely on expensive heat strips below 30°F\u003c\/li\u003e\n\u003cli\u003eACiQ Extreme+ heat pumps save up to 75% in temps below 30°F\u003c\/li\u003e\n\u003cli\u003eExtreme+ heat pump systems provide the best possible performance regardless of climate\u003c\/li\u003e\n\u003cli\u003eVariable BTU inverter ramps up and down to match demand\u003c\/li\u003e\n\u003cli\u003eSmart system with soft startups to maximize efficiency\u003c\/li\u003e\n\u003cli\u003eOK to size for heat - will not short cycle during cooling\u003c\/li\u003e\n\u003cli\u003eExtreme Heat technology keeps you warm to -22°F and beyond\u003c\/li\u003e\n\u003cli\u003eSlim-fit air handler provides more flexibility in installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cstrong\u003eACiQ 5 Ton 16 SEER2 High Efficiency Heat Pump Condenser - R454B Inverter\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/inverterdblcondenser-extremeseries-r454b-800x800_cdddb7f0-a2ea-4bd5-b6be-2656abe18e0a.jpg?v=1745366572\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInverter -\u003c\/strong\u003e The ACiQ-60-HPD 5 ton Extreme series central inverter heat pump utilizes inverter technology to convert AC power to DC, allowing the compressor inside your condenser to speed up and slow down. This allows the system to self-adjust BTU output based on demand. As the weather changes, so will your system output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLearning Condenser -\u003c\/strong\u003e Equipped with advanced sensors, this condenser monitors indoor and outdoor air temperature, duct pressure, refrigerant temperature, and overall performance. During the initial startup, it enters a learning mode that optimizes future operations for maximum efficiency by collecting and storing data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdaptive Sizing -\u003c\/strong\u003e With its self-adjusting inverter design, the ACiQ-60-HPD can be sized based on your heating needs. Standard heat pumps may cause discomfort during summer when sized for heat, but this unit automatically adjusts to function like a smaller unit, ensuring ideal cooling performance without excess humidity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Heat Technology -\u003c\/strong\u003e \"Extreme Heat\" means extended temperature range heating all the way down to -22°F. Traditional heat pumps cannot produce significant heat below about 30°F outside temperature. Below that threshold, they rely on expensive backup electric heat. The ACiQ-60-HPD uses the inverter to vary the refrigerant flow, allowing for maximum heat extraction during extreme cold temperatures. The backup electric heat supplements the heat pump, and only takes over below -22°F. The heat pump gives 100% at 0°F, and still gives 80% at -22°F, saving you up to 75% on cold weather heating bills.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eQuick Facts:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVariable BTU output based on demand: 12,000-54,000 BTU for cooling, 12,000-56,000 for heating\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant\u003c\/li\u003e\n\u003cli\u003eInverter heat pump system for ducted applications\u003c\/li\u003e\n\u003cli\u003eEfficient cooling from -22°F to 122°F outdoor temperatures\u003c\/li\u003e\n\u003cli\u003eEfficient heating from -22°F to 75°F outdoor temperatures\u003c\/li\u003e\n\u003cli\u003eDurable gold fin condenser coil coating for longevity\u003c\/li\u003e\n\u003cli\u003eQuiet operation, even under high workloads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003e5 Ton, 16 SEER2\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eBoasting an efficiency rating of 16 SEER2, the ACiQ-60-HPD provides versatile comfort across a range of climates by providing reliable comfort with a variable output that eliminates short cycling for lasting efficiency.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eExtreme Heat Base Pan Heater Technology\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/1202791852265065.V79GalzXsiYvC06BbKUX_height640_2.png?v=1745400189\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach ACiQ condenser has integrated Extreme Heat technology to maximize heat performance in extreme cold weather. Extended heat pump performance (HyperHeat) harnesses the power of inverter condenser with outdoor temp sensing, variable refrigerant flow and variable condenser fan speed to maximize heat extraction all the way down to -22\u0026amp;deg;F. Plus, every Extreme Heat ACiQ condenser includes a base pan heater to keep ice from collecting on the condenser coil during heat pump operation.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eQuality Construction\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/aciq-quality-construction_481ba85c-45cf-4833-9e5e-761bf5008274.jpg?v=1745400214\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eState-of-the-Art manufacturing is behind every ACiQ product, resulting in quiet, effective operation over a long service life. Most models have low ambient heating and cooling.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eHighest Efficiency\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/compressor_1_1.png?v=1745400241\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eACiQ saves you money up front, but also over time by reducing energy bills. Every ACiQ condenser features a variable inverter twin rotary compressor, lowering wear and increasing performance. Compare specs against other brands in the same price category, and you will agree, ACiQ is the best value.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eLonger life, longer warranty\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/aciq-longer-warranty_1.png?v=1745400254\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIntelligent design goes into every element of ACiQ’s manufacturing ensuring flawless performance for years. Low friction, variable inverter twin rotary compressors give bulletproof reliability. Register equipment at ACiQ.com to extend warranty protection to 7 years parts, 12 years compressor.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eSelf Cleaning Condenser\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cstyle\u003e.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }\u003c\/style\u003e\n\u003cdiv class=\"embed-container\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/iMcIRhT79vA\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp\u003eACiQ condensers stay clean and efficient with self-cleaning technology built right in. At the end of each cycle, the fan reverses direction and blows air out the back of the unit — helping remove leaves, dirt, and debris before buildup can begin.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cstrong\u003eACiQ 5 Ton Extreme+ Ducted Air Handler - R454B\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/ExtremePlus_Inv_AirHandler-Front-800x800.jpg?v=1745398113\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eRedefining Comfort with Extreme+ Efficiency\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe ACIQ-60-PAH Extreme+ ducted air handler is one of the best multi-positional air handlers on the market today. Featuring a variable speed DC blower, communicating technology, and the best possible performance in any climate, comfort and efficiency levels hit extreme peaks well above the standard maximums from other typical air handlers. Your thermostat communicates with the inverter condenser outside and this air handler inside, telling the system when to self-adjust its BTU output in order to maximize efficiency while providing your desired level of comfort.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e5 ton high efficiency central ducted air handler\u003c\/li\u003e\n\u003cli\u003eCompatible with any 24v thermostat\u003c\/li\u003e\n\u003cli\u003eVariable speed DC blower\u003c\/li\u003e\n\u003cli\u003eMulti-positional - Can be installed in upflow, downflow, or horizontal left\/right orientations\u003c\/li\u003e\n\u003cli\u003eSlim-fit cabinet size for easier installation\u003c\/li\u003e\n\u003cli\u003eHigher-performance capabilities leading to better tax credit and rebate eligibility\u003c\/li\u003e\n\u003cli\u003eCompatible with R454B refrigerant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eInstallation and Maintenance\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eInstallation is very similar to installing any replacement air handler. Your technician will make electrical, refrigerant, thermostat, and communication connections as well as connect the air handler to your return and supply ductwork. The ACiQ Extreme+ central ducted air handler is multi-positional (upflow, downflow or horizontal) and utilizes a narrower cabinet than other air handlers, making it a very versatile, easy-to-install air handler. Any 24v thermostat with 2 stages of heating can control the system. Supplemental electric heat kits are available as a backup heat source for the coldest days of the year. If any maintenance is required, the intelligent control board in the air handler displays fault codes in case any part of the system experiences issues.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note -\u003c\/strong\u003e in order to function, this air handler must be installed with a condenser and other installation equipment, available at an additional cost if not already included in this product bundle. To use straight electric heating, an electric heat kit is necessary and is also available at an additional cost.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x ACiQ 5 Ton 16 SEER2 High Efficiency Heat Pump Condenser - R454B Inverter\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e1x ACiQ 5 Ton Extreme+ Ducted Air Handler - R454B\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eHeat Pump Condenser Specifications:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 813.751px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003eACiQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003eACiQ-60-HPD\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 39.1875px;\"\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 39.1875px;\"\u003e25'\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e275.130000\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eReplaces\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003eACiQ-60-HPB\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 39.1875px;\"\u003eProduct Features\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 39.1875px;\"\u003eInverter, Low Ambient Heating, Two Stage Condenser, Variable Speed Condenser\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eCooling BTU\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e55,000 BTU\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eHeating BTU\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e59,000 BTU\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eMaximum CFM\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e1807\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 39.1875px;\"\u003eDecibel Level (dBA)\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 39.1875px;\"\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eElectric Heat\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003eHeat Pump\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 20.5938px;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 20.5938px;\"\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eSEER2\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eCondenser Stages\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003eVariable Speed\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003eRotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eLiquid Valve Size\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e3\/8\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eSuction Valve Size\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e3\/4\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e208\/230V 1 Phase 60 Hz\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e40 Amps\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eMin. Breaker Size\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e40 Amps\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eTonnage\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e5 Ton\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eBTU\/Tonnage\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e60,000 BTU\/5 Ton\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 39.1875px;\"\u003eMin\/Max Outdoor Temp for Heating\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 39.1875px;\"\u003e-22°F - 75°F\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 39.1875px;\"\u003eMin\/Max Outdoor Temp for Cooling\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 39.1875px;\"\u003e-22°F - 122°F\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 58.7812px;\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 58.7812px;\"\u003e-22°F - 122°F\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e58.3\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e37.5\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 20.5938px;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 20.5938px;\"\u003e16.3\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003e12 Years Compressor and 7 Years Parts with Online Registration\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.1875px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 67.1875px;\"\u003eResources\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 67.1875px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/HPD-EHPD-Install-Manual.pdf\"\u003eHPD Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/HPD-EHPD-Service-Manual.pdf\"\u003eHPD Service Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACiQ-AHD-EHPD-HPD-Nominal-Capacity-Performance-Chart-040825-PDF-1.pdf\"\u003eHPD Heating\/Cooling Performance\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6564%; height: 19.5938px;\"\u003eSafety Information\u003c\/td\u003e\n\u003ctd style=\"width: 76.9759%; height: 19.5938px;\"\u003eProposition 65 Warning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAir Handler Specifications:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 548.626px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003eACiQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003eACiQ-60-PAH\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003e188.050000\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eCooling BTU\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003e54,000 BTU\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eMaximum CFM\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003e1801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 39.1875px;\"\u003eDecibel Level (dBA)\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 39.1875px;\"\u003eUp to 60 Decibels\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 58.7812px;\"\u003eElectric Backup Heat Capabilities (Optional)\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 58.7812px;\"\u003e5 Kilowatts, 8 Kilowatts, 10 Kilowatts, 15 Kilowatts, 20 Kilowatts\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003eMulti-Positional\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eLiquid Line\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003e3\/8\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eSuction Line\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003e3\/4\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003e208\/230V 1 Phase 60 Hz\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003e15 Amps\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eMin. Breaker Size\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003e14.5 \/ 10.0 Amps\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eTonnage\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003e5 Ton\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eBTU\/Tonnage\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003e60,000 BTU\/5 Ton\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eMini Split Type\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003eMulti-Positional\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 39.1875px;\"\u003eZone Compatibility\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 39.1875px;\"\u003eSingle Zone\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eConnection\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003eFlared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003e56\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003e24.5\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003e21.5\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003e12 Years Compressor and 7 Years Parts with Online Registration\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.6183%; height: 19.5938px;\"\u003eResources\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%; height: 19.5938px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/PAH-Install-Manual.pdf\"\u003e\u003cspan style=\"color: #1f2124;\"\u003ePAH Installation Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/PAH-Owners-Manual.pdf\"\u003e\u003cspan style=\"color: #1f2124;\"\u003ePAH Owner's Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/HPD-PAH-5Ton-Submittal.pdf\"\u003e\u003cspan style=\"color: #1f2124;\"\u003e5 Ton HPD \/ PAH Submittal\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.6183%;\"\u003eSafety Information\u003c\/td\u003e\n\u003ctd style=\"width: 77.014%;\"\u003eProposition 65 Warning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ACiQ","offers":[{"title":"Default Title","offer_id":50557137912128,"sku":"ACiQ-60-HPD \/ ACiQ-60-PAH","price":6699.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/ACiQ-Extreme-Series-5-Ton-17-5-SEER2-High-Efficiency-Heat-Pump-Split-System-R454B-Inverter-Multi-Positional-ACiQ-60-HPD-ACiQ-60-PAH-Mini-Split-Systems-Direct-40689531060544.jpg?v=1768988357","url":"https:\/\/minisplitsystemsdirect.com\/products\/aciq-extreme-series-5-ton-17-5-seer2-high-efficiency-heat-pump-split-system-r454b-inverter-multi-positional","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}