{"product_id":"daikin-dkn-plus-interface-azai6wspdkc","title":"Daikin DKN Plus Interface - AZAI6WSPDKC","description":"\u003ch3\u003e\u003cstrong\u003eDaikin DKN Plus Interface - AZAI6WSPDKC\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe DKN Plus Interface enables the energy-efficient control of Daikin air conditioners by a third-party thermostat or an automation system. With this interface, third-party devices or systems can control the VRV, SkyAir, and Daikin Single\/Multi-Zone indoor units through Cloud API, Modbus, BACnet™ MS\/TP, or thermostat relay contacts. This interface can be commissioned with ease through the DKN Cloud North America (NA) app via Bluetooth Low Energy (BLE).\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Compatibility:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 76px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 31.0219%; height: 19px;\"\u003eIndoor Unit Family\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 38.1388%; height: 19px;\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"width: 29.3796%; height: 19px;\"\u003eType\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 31.0219%; height: 19px;\"\u003eVRV and VRV LIFE\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 38.1388%; height: 19px;\"\u003eCXTQ, FXAQ, FXDQ, FXEQ, FXFQ, FXHQ, FXLQ, FXMQ, FXNQ, FXSQ, FXTQ, FXUQ, FXZQ\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 29.3796%; height: 19px;\"\u003eP1P2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 31.0219%; height: 19px;\"\u003eSkyAir\u003c\/td\u003e\n\u003ctd style=\"width: 38.1388%; height: 19px;\"\u003eFAQ, FBQ, FTQ, FCQ, FHQ\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 29.3796%; height: 19px;\"\u003eP1P2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 31.0219%; height: 19px;\"\u003eSingle-Zone and Multi-Zone\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 38.1388%; height: 19px;\"\u003eFDMQ, FFQ\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 29.3796%; height: 19px;\"\u003eP1P2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0219%;\"\u003eSingle-Zone and Multi-Zone\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 38.1388%;\"\u003eCDXS, CTXS*, FDXS, FTK*, FTKB*, FTX*, FTXB* FTXG, FTXR, FTXS, FVXS, FTXM\u003c\/td\u003e\n\u003ctd style=\"width: 29.3796%;\"\u003eS21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e*FTK_AXVJU, FTKB_AXVJU, FTX_AXVJU, FTXB_AXVJU and CTX_AXVJU units are not compatible.\u003c\/p\u003e\n\u003cp\u003eThe following indoor units do not have the S21 connection and require an additional interface adaptor (ordered separately) to\u003cbr\u003eprovide the S21 connector:\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.3894%;\"\u003e\u003cstrong\u003eIndoor Unit Models\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2416%;\"\u003e\u003cstrong\u003eRequired Interface Adaptor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.3894%;\"\u003eFTX09NMVJU(A), FTX12NMVJU(A), FTX09WVJU9, FTX12WVJU9\u003c\/td\u003e\n\u003ctd style=\"width: 53.2416%;\"\u003eKRP067A41E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.3894%;\"\u003eFTX15NMVJU(A), FTX15WVJU9\u003c\/td\u003e\n\u003ctd style=\"width: 53.2416%;\"\u003eKRP980B2E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.3894%;\"\u003eFTXM09VVJU, FTXM12VVJU, FTXM18VVJU, FTXM24VVJU, FTXM09WVJU9, FTXM12WVJU9, FTXM18WVJU9, FTXM24WVJU9\u003c\/td\u003e\n\u003ctd style=\"width: 53.2416%;\"\u003eKER087A41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eVersatile interface that can integrate with smart thermostat through multiple approaches:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCloud API (Honeywell Home App\/Cloud – Ecobee App\/Cloud – Nest App\/Cloud)\u003c\/li\u003e\n\u003cli\u003eLocal API (integration to Daikin Color Touch (DT4272C) with firmware v4.05 - Premium Mini (D2270C) “Future”\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e3rd party thermostat G\/Y\/W (Fan\/Cool\/Heat) relay control through thermostat wiring\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatically disables thermostat relay logic when cloud API connection detected.\u003c\/li\u003e\n\u003cli\u003eCustom control logic applied to minimize the loss of the indoor unit efficiency when no cloud API, BACnet or Modbus connection detected\u003c\/li\u003e\n\u003cli\u003eCompatible Daikin thermostats: App Stat 250803400 – Value Series (TSTATD1100-2 or TSTATD1152-2) – Premium series (D4271C) – Premium Mini (D2270C) – Color Touch (DT4272C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEasy commissioning with Bluetooth configuration App (DKN Cloud NA App)\u003c\/p\u003e\n\u003cp\u003eIndoor unit control and monitoring points (for integration through cloud, Modbus, and BACnet MS\/TP only)\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/Off – Setpoint - Room temperature - Mode (Auto, Cool, Heat, Fan, Dry) - Fan speed - Louver position - Error code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIndoor unit force off by interlock control through digital input dry contact.\u003c\/p\u003e\n\u003cp\u003eControls auxiliary heater with dry contact as a secondary heat source:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTurn on and off the auxiliary heater based on the differential (configured in App) between the setpoint and the room temperature\u003c\/li\u003e\n\u003cli\u003eEnable\/Disable the auxiliary heater based on outdoor temperature (S21 IDU only)\u003c\/li\u003e\n\u003cli\u003eThe user can enable the emergency heat mode from the DKN App\n\u003cul\u003e\n\u003cli\u003eIf the indoor unit has an error, the user can enable the emergency heater from the app.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIntegration to home automation systems through software drivers\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCrestron\u003c\/li\u003e\n\u003cli\u003eControl4\u003c\/li\u003e\n\u003cli\u003eRTI Control\u003c\/li\u003e\n\u003cli\u003eFibaro\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eModbus RTU and BACnet MS\/TP Integration\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe following points are available:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/fe487e32-0c69-4630-85d2-d2965ab525bb.png?v=1735437899\"\u003e\u003c\/p\u003e\n\u003cp\u003e** The room temperature is writable for P1P2 indoor units only and read only for S21 indoor units.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 593.438px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.4823%; height: 19.5938px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 65.1487%; height: 19.5938px;\"\u003eDaikin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.4823%; height: 19.5938px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 65.1487%; height: 19.5938px;\"\u003eAZAI6WSPDKC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.4823%; height: 19.5938px;\"\u003eDescription\u003c\/td\u003e\n\u003ctd style=\"width: 65.1487%; height: 19.5938px;\"\u003eDKN Plus Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.4823%; height: 19.5938px;\"\u003eMaximum connections\u003c\/td\u003e\n\u003ctd style=\"width: 65.1487%; height: 19.5938px;\"\u003e1 for each S21\/P1P2 indoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.1875px;\"\u003e\n\u003ctd style=\"width: 34.4823%; height: 67.1875px;\"\u003eWiring\u003c\/td\u003e\n\u003ctd style=\"width: 65.1487%; height: 67.1875px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eS21 Wire:\u003c\/strong\u003e 8.2 ft \/ 2.5 m (Included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP1P2 Wire:\u003c\/strong\u003e 8.2 ft \/ 2.5 m (Included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 34.4823%; height: 39.1875px;\"\u003eModbus RTU \/ BACnet MSTP communication baud rate\u003c\/td\u003e\n\u003ctd style=\"width: 65.1487%; height: 39.1875px;\"\u003e9600, 19200, 38400, 57600, 76800, 115200 bps (Default: 38400)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 106.375px;\"\u003e\n\u003ctd style=\"width: 34.4823%; height: 106.375px;\"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"width: 65.1487%; height: 106.375px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor DKN Plus Interface:\u003c\/strong\u003e 12-16VDC from indoor unit PCB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor 3rd party thermostat:\u003c\/strong\u003e 24VAC from external power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.4823%; height: 19.5938px;\"\u003e\n\u003cp\u003eContact Rating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.1487%; height: 19.5938px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital output (Aux. Heat):\u003c\/strong\u003e 1 amp. at 24VAC (Normally Open (NO))\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Input (Force Off):\u003c\/strong\u003e Dry contact (Configurable as NO or NC).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.4823%; height: 19.5938px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 65.1487%; height: 19.5938px;\"\u003e3.62 in x 3.15 in x 1.14 in \/ 92mm x 80 mm x 29 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.4823%; height: 19.5938px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 65.1487%; height: 19.5938px;\"\u003e3.24 oz \/ 92g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.4823%; height: 19.5938px;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd style=\"width: 65.1487%; height: 19.5938px;\"\u003e-4°F to 158°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4823%;\"\u003eOperation temperature\u003c\/td\u003e\n\u003ctd style=\"width: 65.1487%;\"\u003e32°F to 113°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4823%;\"\u003eCompliance\u003c\/td\u003e\n\u003ctd style=\"width: 65.1487%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eEMC with the standard 47 CFR Part 15B (US)\u003c\/li\u003e\n\u003cli\u003eEMC with ICES-003 Issue 6 standard (Canada)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 223.938px;\"\u003e\n\u003ctd style=\"width: 34.4823%; height: 223.938px;\"\u003eResources\u003c\/td\u003e\n\u003ctd style=\"width: 65.1487%; height: 223.938px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/pf-dknplus.pdf?v=1711269417\"\u003eProduct Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/5fd87514-95ff-48ca-ac50-3cc9004d2bfe.pdf?v=1735435855\"\u003eApplication Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/11be4839-69e7-48a6-ae46-221105abd6a6.pdf?v=1735435973\"\u003eDaikin DKN Plus with 3rd Party Thermostat\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/im_azai6wspdkc_en_fr_es_2107.pdf?v=1711269465\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/em_vrv-controls_compressed_44c44b44-3df3-4b3e-bf5b-46619a9cc2f2.pdf?v=1711269648\"\u003eEngineering Manual - VRV Controls\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/om_dkn_modbus.pdf?v=1711269711\"\u003eModbus Integration Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/om_dkn_azai6wspdkc_bacnet.pdf?v=1711269767\"\u003eBACNet integration Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/iom_dkns-2101.pdf?v=1711269862\"\u003eOperation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/sds-azai6wscdka.pdf?v=1711269941\"\u003eSubmittal Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/pwdayqf_9d164cef-1c3a-499b-81d0-0c42283525c3.pdf?v=1711270017\"\u003eWarranty Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"DAIKIN","offers":[{"title":"Default Title","offer_id":48087644700992,"sku":"AZAI6WSPDKC","price":343.33,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Daikin-DKN-Plus-Interface-AZAI6WSPDKC-AZAI6WSPDKC-Mini-Split-Systems-Direct-36619699061056.jpg?v=1768991460","url":"https:\/\/minisplitsystemsdirect.com\/products\/daikin-dkn-plus-interface-azai6wspdkc","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}