{"product_id":"goodman-92-afue-single-stage-upflow-horizontal-multi-speed-40k-btu-low-nox-natural-gas-furnace-14-5-wide-gr9s920403an","title":"Goodman 92% AFUE Single Stage Upflow\/Horizontal multi-speed 40k BTU Low NOx Natural Gas furnace (14\" wide) (GR9S920403AN)","description":"\u003ch2\u003e\u003cstrong\u003eGoodman 92% AFUE Single Stage Upflow\/Horizontal multi-speed 40k BTU Low NOx Natural Gas furnace (14\" wide) (GR9S920403AN)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe GR9S920403AN Goodman gas furnace features high-quality construction and efficient operation at a great value. The GR9S920403AN single-stage, 9-speed furnace utilizes Goodman's superior heat exchanger design to provide efficient, reliable heating to your home. If you're looking to cut your energy bills and improve your comfort without breaking the bank, your search stops with the Goodman GR9S920403AN.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eQUICK FACTS\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThis furnace is ideal to heat a smaller house (depending on climate)\u003c\/li\u003e\n\u003cli\u003e40,000 BTU 92% efficient natural gas furnace\u003c\/li\u003e\n\u003cli\u003eRequires plastic\/PVC flue venting\u003c\/li\u003e\n\u003cli\u003eComplies with Clean Air Act New Refrigerant Requirements\u003c\/li\u003e\n\u003cli\u003eCan be used in the upflow or horizontal orientation\u003c\/li\u003e\n\u003cli\u003eCan be converted to an LP furnace with a conversion kit (sold separately)\u003c\/li\u003e\n\u003cli\u003eInnovative design for electrical efficiency, safety, and lower sound output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e40,000 BTU\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe GR9S920403AN Goodman gas furnace is 40,000 BTU's, which is the smallest Goodman furnace size currently available. This BTU count is a measure of the input of the furnace per hour, while the output of this furnace is 36,800 BTU's (40,000 X 92% AFUE) per hour. In ideal climate conditions, this 40,000 BTU furnace is usually used to heat a small house.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e92% Efficiency Rating\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe GR9S920403AN Goodman gas furnace is 92% efficient, which is one of the highest efficiencies for gas furnaces on the market today. This efficiency means that 92% of the gas going into the furnace is used to heat your home, while the remaining 8% is lost to the furnace operation itself. Please note that all furnaces that are 90% efficient and above require plastic\/pvc flue venting, while 80% efficient furnaces require plastic\/PVC flue venting.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSingle Stage Furnace\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe GR9S920403AN Goodman gas furnace is a single stage furnace has only one heat output. Regardless of the indoor temperature, this furnace will burn at 100% output whenever the thermostat calls for it. Like a light switch, this furnace's burner will either be on or off and nothing in between. A single stage furnace is the standard efficient furnace since every time your furnace turns on the furnace uses the same amount of energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eNatural Gas or LP Furnace\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eFrom the factory, the GR9S920403AN runs on natural gas. However all Goodman gas furnaces can be converted to propane using the furnace's corresponding\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/minisplitsystemsdirect.com\/products\/goodman-amana-liquid-propane-lp-conversion-kit-lpm-33\"\u003eLP conversion kit\u003c\/a\u003e, an optional accessory at an additional cost that consists of a replacement set of orifices and springs.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e9-Speed ECM Blower Motor\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eInstead of the last generation PSC blower motor, the GR9S920403AN utilizes a 9-speed ECM motor, which uses less power and provides smarter air circulation. All of this causes an overall increase in the electrical efficiency of your furnace, which saves you money.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eWith installation that follows your state and local codes and with online registration, all Goodman furnaces come with a 10-year parts and lifetime heat exchanger warranty through the manufacturer.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eDurable Hot Surface Igniter\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe hot surface igniter on modern Goodman furnaces are more durable than previous designs, decreasing related issues and lowering maintenance costs. These hot surface ignitors are also more efficient than standing pilot and older HSI designs, saving you even more money.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSelf-Diagnostic Control Board\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Goodman brand has improved technology from years of production experience, allowing for a long-lasting product that rarely has any issues. However, if something does go wrong on the furnace, the control board has a set of sensors that allow it to diagnose basic issues, allowing for easy troubleshooting and to notify the owner if basic maintenance or warranty work is recommended. This increases the overall safety of the unit, for the furnace itself and the occupants of the home where it is installed.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eHeavy Gauge Steel Cabinet\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe heavy-gauge steel cabinet on new Goodman furnaces provide adequate protection to the internal mechanisms of the unit. The cabinet is also more air-tight than previous models, allowing for a quiet, more economical unit due to losing less heat and preventing more sound from exiting the unit.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eEase of Installation\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe value of modern Goodman furnaces doesn't end at efficiency. Today's Goodman furnaces feature many different connection options to reduce installation. The GR9S920403AN model has a more universal design, which consists of its ability to be installed in both an upflow or horizontal configuration. This allows for an easier installation in more locations, from your attic to your basement. The furnace also comes with color-coded low-voltage terminals that allow for a shorter and easier installation time, which decreases installation costs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable id=\"product-attribute-specs-table\" class=\"data table additional-attributes\"\u003e\n\u003ccaption class=\"table-caption\"\u003e\u003c\/caption\u003e\n\u003ctbody data-additional-product-id=\"175601\" class=\"child-product-section\" data-role=\"additional-info\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" colspan=\"2\"\u003eGoodman 92% 40,000 BTU Single Stage Gas Furnace - 14\" Width - Upflow \/ Horizontal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eSKU\u003c\/th\u003e\n\u003ctd data-th=\"SKU\" class=\"col data\"\u003eGR9S920403AN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eWeight (in lbs)\u003c\/th\u003e\n\u003ctd data-th=\"Weight (in lbs)\" class=\"col data\"\u003e106.000000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eAHRI Certificate Number\u003c\/th\u003e\n\u003ctd data-th=\"AHRI Certificate Number\" class=\"col data\"\u003e215224963\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eAirflow Direction\u003c\/th\u003e\n\u003ctd data-th=\"Airflow Direction\" class=\"col data\"\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eExhaust Flue Requirement\u003c\/th\u003e\n\u003ctd data-th=\"Exhaust Flue Requirement\" class=\"col data\"\u003ePlastic \/ PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eBrand\/Manufacturer\u003c\/th\u003e\n\u003ctd data-th=\"Brand\/Manufacturer\" class=\"col data\"\u003eGoodman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eProduct Features\u003c\/th\u003e\n\u003ctd data-th=\"Product Features\" class=\"col data\"\u003eNew Refrigerant Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eFurnace Efficiency \/ AFUE\u003c\/th\u003e\n\u003ctd data-th=\"Furnace Efficiency \/ AFUE\" class=\"col data\"\u003e92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eHeating BTU\u003c\/th\u003e\n\u003ctd data-th=\"Heating BTU\" class=\"col data\"\u003e40,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eBlower Motor\u003c\/th\u003e\n\u003ctd data-th=\"Blower Motor\" class=\"col data\"\u003e9 Speed - ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eMaximum CFM\u003c\/th\u003e\n\u003ctd data-th=\"Maximum CFM\" class=\"col data\"\u003e1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd data-th=\"Configuration\" class=\"col data\"\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eElectrical\u003c\/th\u003e\n\u003ctd data-th=\"Electrical\" class=\"col data\"\u003e115 V. 1 Phase 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eMax Breaker Size\u003c\/th\u003e\n\u003ctd data-th=\"Max Breaker Size\" class=\"col data\"\u003e15 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eMin. Breaker Size\u003c\/th\u003e\n\u003ctd data-th=\"Min. Breaker Size\" class=\"col data\"\u003e9.7 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eBurner Stages\u003c\/th\u003e\n\u003ctd data-th=\"Burner Stages\" class=\"col data\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eFuel Type\u003c\/th\u003e\n\u003ctd data-th=\"Fuel Type\" class=\"col data\"\u003ePropane, Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eHeight\u003c\/th\u003e\n\u003ctd data-th=\"Height\" class=\"col data\"\u003e34.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eWidth\u003c\/th\u003e\n\u003ctd data-th=\"Width\" class=\"col data\"\u003e14\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eDepth\u003c\/th\u003e\n\u003ctd data-th=\"Depth\" class=\"col data\"\u003e28.75\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eWarranty\u003c\/th\u003e\n\u003ctd data-th=\"Warranty\" class=\"col data\"\u003eLifetime Heat Exchanger and 10 Years Parts with Online Registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eResources\u003c\/th\u003e\n\u003ctd data-th=\"Resources\" class=\"col data\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/GR9S96_GD9S96_GR9S92-Install-Manual.pdf\"\u003eGR9S92 Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/GR9S92%20Spec%20Sheet.pdf\"\u003eGR9S92 Specifications Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/GR9S92%20Warranty.pdf\"\u003eGoodman Furnace Warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\nYou will need Adobe® Acrobat® Reader to view PDF documents.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eSafety Information\u003c\/th\u003e\n\u003ctd data-th=\"Safety Information\" class=\"col data\"\u003e\n\u003cdiv class=\"gas-installation\"\u003eThis gas appliance requires a trained technician to install. Improperly connecting gas lines or improperly connecting a gas flue or venting may result in death. By purchasing this item, you are agreeing that you are using a trained technician to install this gas appliance. We will not be responsible for any injury or property damage arising from improper service or service procedures. Whoever installs or services this unit assumes responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install this equipment.\u003c\/div\u003e\n\u003cbr\u003e\u003ca\u003ePROPOSITION 65 WARNING\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51371613421888,"sku":"GR9S920403AN","price":1592.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Goodman-92-AFUE-Single-Stage-Upflow-Horizontal-multi-speed-40k-BTU-Low-NOx-Natural-Gas-furnace-14-wide-GR9S920403AN-GR9S920403AN-Mini-Split-Systems-Direct-42282883875136.jpg?v=1769067637","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-92-afue-single-stage-upflow-horizontal-multi-speed-40k-btu-low-nox-natural-gas-furnace-14-5-wide-gr9s920403an","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}