{"product_id":"goodman-gpch36031","title":"Goodman GPCH36031 Packaged Air Conditioner (5.0 Ton, 13.4 SEER2, R-32, Horizontal discharge, 208\/230V 1-Ph)","description":"\u003cp\u003e\u003cstrong\u003eGPCH36031\u003c\/strong\u003e is a 5.0-ton Goodman GPCH3 R-32 packaged air conditioner built for ducted cooling. Horizontal discharge (packaged AC-only).\u003c\/p\u003e\n\u003cp\u003eA packaged air conditioner combines the compressor, condenser coil, evaporator coil, and blower into a single outdoor cabinet—often installed at ground level or on a rooftop—so you don’t need a separate indoor air handler cabinet inside the building.\u003c\/p\u003e\n\n\u003ch2\u003eAt-a-glance (this exact model)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e5.0 ton (model code 60)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eRated cooling capacity\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e56,000 BTU\/h total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eSensible capacity (temperature drop portion)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e40,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eEfficiency ratings\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e13.4 SEER2 \/ 10.6 EER2 — SEER2 reflects seasonal cooling efficiency and EER2 reflects efficiency at peak conditions; higher numbers mean more cooling per unit of electricity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eRefrigerant\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003eR-32 (charge: 78 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eIndoor airflow (nominal)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e1,675 CFM via 5-speed ECM blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eSound level\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e78 dB (per spec sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSizing \u0026amp; selection guidance\u003c\/h2\u003e\n\u003cp\u003e“Ton” is a nominal sizing label (1 ton ≈ 12,000 BTU\/h). Proper sizing still requires a load calculation (for example, ACCA Manual J\/S or a commercial heat gain analysis). Oversized equipment can short-cycle and under-dehumidify; undersized equipment may struggle on design days.\u003c\/p\u003e\n\u003ch2\u003eWhat the model number tells you\u003c\/h2\u003e\n\u003cp\u003eGoodman packaged unit model numbers encode the nominal size and electrical configuration.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e60\u003c\/strong\u003e = 5 ton nominal size\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3\u003c\/strong\u003e = 13.4 SEER2 efficiency tier in this series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1\u003c\/strong\u003e = 208\/230 V, 1 phase, 60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCore components \u0026amp; performance details\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eCompressor\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003eScroll compressor, two-stage (RLA 27.1, LRA 178.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eCondenser coil\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003eCopper tube \/ aluminum fin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eEvaporator coil\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003eAll-aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eMetering device\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003eTXV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eCondensate drain connection\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e3\/4\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eIndoor blower motor\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003eECM, 3\/4 HP, 5.4 FLA, 5 speeds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eOutdoor fan motor\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e1\/4 HP, 1.4 FLA, 22\" blade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis unit uses R-32 refrigerant (ASHRAE safety class A2L: lower toxicity with mild flammability). Installation and service should follow current local code requirements for A2L refrigerants and be performed by qualified technicians.\u003c\/p\u003e\n\u003ch2\u003eAirflow, ductwork \u0026amp; installation planning\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eDuct openings (supply \/ return)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e14x14 \/ 14x24 (W×H, inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eAirflow configuration\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003eHorizontal discharge (packaged AC-only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor jobs that require electric heat, this series supports field-installed electric heat kits (5–20 kW options are listed for GPCH3). Heat kit selection should match local design loads and available electrical capacity.\u003c\/p\u003e\n\u003ch2\u003eElectrical requirements (verify before installation)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003ePower supply\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e208\/230 V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eMinimum Circuit Ampacity (MCA)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e40.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eMaximum Overcurrent Protection (MOCP)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e60 A (use time-delay fuses or HACR breakers per spec sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eAlways verify final electrical data on the unit’s nameplate and size wiring per the National Electrical Code and local codes. Long wire runs may require larger conductor sizes.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eDimensions, clearances \u0026amp; weight\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eCabinet footprint (W×D)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e66\" × 34\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eCabinet height references (A \/ B)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e36\" \/ 38.5\" (chassis size: Large)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eWeight (operating \/ shipping)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e400 \/ 410 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eConstruction, durability \u0026amp; certifications\u003c\/h2\u003e\n\u003ch3\u003eStandard features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e13.4 SEER2 efficiency (2–5 ton sizes)\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient scroll compressor (see model-specific compressor details below)\u003c\/li\u003e\n\u003cli\u003eMulti-speed ECM indoor blower motor (5 speeds)\u003c\/li\u003e\n\u003cli\u003eQuiet horizontal discharge airflow\u003c\/li\u003e\n\u003cli\u003eCopper tube \/ aluminum fin condenser coil\u003c\/li\u003e\n\u003cli\u003eAll-aluminum evaporator coil\u003c\/li\u003e\n\u003cli\u003eTotally enclosed, permanently lubricated condenser fan motor\u003c\/li\u003e\n\u003cli\u003eFully charged system (refrigerant charge listed by model)\u003c\/li\u003e\n\u003cli\u003eField-installed electric heat kit option (5–20 kW options listed for this series)\u003c\/li\u003e\n\u003cli\u003eAHRI Certified; UL Listed\u003c\/li\u003e\n\u003cli\u003eENERGY STAR® certified: No (per manufacturer product page)\u003c\/li\u003e\n\u003cli\u003eComfortBridge™ compatibility: No (per manufacturer product page)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHeavy-gauge galvanized-steel cabinet with architectural gray powder-paint finish\u003c\/li\u003e\n\u003cli\u003eLouvered condenser coil protection\u003c\/li\u003e\n\u003cli\u003eAluminum foil-facing internal insulation reinforced with fiberglass scrim\u003c\/li\u003e\n\u003cli\u003eFully insulated blower compartment with convenient access panels\u003c\/li\u003e\n\u003cli\u003eMeets cabinet air leakage requirements when tested to ASHRAE Standard 193\u003c\/li\u003e\n\u003cli\u003eOne footprint across tonnages\u003c\/li\u003e\n\u003cli\u003eWhen properly anchored, meets 2023 Florida Building Code unit integrity requirements for hurricane-type winds (anchor bracket kits available)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e AHRI Certified and UL Listed (per manufacturer specification sheet). AHRI certification helps verify published performance ratings.\u003c\/p\u003e\n\u003ch2\u003eCommon accessories for this chassis size\u003c\/h2\u003e\n\u003cp\u003eAccessory availability can depend on chassis size (Small vs. Medium\/Large) and the installation configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownflow Economizer (use with PCCP roof curb)\u003c\/strong\u003e: DDNECNJPCHHA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownflow Plenum Kit (use with PCCP roof curb)\u003c\/strong\u003e: PCP101-103\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownflow Plenum Kit (R-8) (use with PCCP roof curb)\u003c\/strong\u003e: PCP101-103 R8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElbow Flashing w\/R-8 Liner\u003c\/strong\u003e: PCEF101-103\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEconomizer Wiring Harness\u003c\/strong\u003e: 0259G00213\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Horizontal Filter Rack\u003c\/strong\u003e: DPHFRA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontal Economizer\u003c\/strong\u003e: DHZECNJPGCHM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInline Fuse Kit\u003c\/strong\u003e: INFKPKG01\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003ePlus 8 more listed accessories for this chassis size in the manufacturer’s spec sheet.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eWhat you’ll typically need in addition to the unit\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProfessional installation (set\/anchor curb or pad, connect supply\/return ductwork, connect condensate drain, connect power and controls).\u003c\/li\u003e\n\u003cli\u003eA compatible thermostat\/control (often supplied separately).\u003c\/li\u003e\n\u003cli\u003eAn outdoor service disconnect and properly sized branch circuit protection (per MOCP).\u003c\/li\u003e\n\u003cli\u003eIf installed on a roof: the correct roof curb and any downflow\/transition pieces required for your duct layout.\u003c\/li\u003e\n\u003cli\u003eFilters and filter rack solutions as required by your installation (manufacturer lists optional filter rack accessories).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\u003cp\u003e10-Year Parts Limited Warranty available with online registration completed within 60 days of installation (registration not required in California, Florida, or Québec; other limitations and exceptions may apply).\u003c\/p\u003e\n\u003ch2\u003eBefore you order (quick checklist)\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm you need an AC-only packaged unit (not a heat pump).\u003c\/li\u003e\n\u003cli\u003eConfirm nominal size: 5.0 ton and rated capacity 56,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003eConfirm installation orientation\/duct configuration: Horizontal discharge (packaged AC-only).\u003c\/li\u003e\n\u003cli\u003eConfirm your electrical service supports the unit’s MCA and MOCP.\u003c\/li\u003e\n\u003cli\u003eIf adding an economizer or downflow setup, confirm the required curb\/duct cover\/relay kits and chassis-specific part numbers.\u003c\/li\u003e\n\u003cli\u003eConfirm local requirements for installing and servicing A2L refrigerants (R-32).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"GPCH36031","offer_id":51549584654656,"sku":"GPCH36031","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/gph-h_gpc-h-toplft-hr__72563.jpg?v=1772501369","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gpch36031","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}