{"product_id":"goodman-gpcm32431","title":"Goodman GPCM32431 Packaged Air Conditioner (2.0 Ton, 13.4 SEER2, R-32, Multi-position (horizontal or downflow), 208\/230V 1-Ph)","description":"\u003cp\u003e\u003cstrong\u003eGPCM32431\u003c\/strong\u003e is a 2.0-ton Goodman GPCM3 R-32 packaged air conditioner built for ducted cooling. Convertible airflow: horizontal or downflow (packaged AC-only).\u003c\/p\u003e\n\u003cp\u003eA packaged air conditioner combines the compressor, condenser coil, evaporator coil, and blower into a single outdoor cabinet—often installed at ground level or on a rooftop—so you don’t need a separate indoor air handler cabinet inside the building.\u003c\/p\u003e\n\n\u003ch2\u003eAt-a-glance (this exact model)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e2.0 ton (model code 24)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eRated cooling capacity\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e24,000 BTU\/h total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eSensible capacity (temperature drop portion)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e18,480 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eEfficiency ratings\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e13.4 SEER2 \/ 10.6 EER2 — SEER2 reflects seasonal cooling efficiency and EER2 reflects efficiency at peak conditions; higher numbers mean more cooling per unit of electricity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eRefrigerant\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003eR-32 (charge: 63 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eIndoor airflow (nominal)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e800 CFM via 5-speed ECM blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eSound level\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e74 dB (per spec sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSizing \u0026amp; selection guidance\u003c\/h2\u003e\n\u003cp\u003e“Ton” is a nominal sizing label (1 ton ≈ 12,000 BTU\/h). Proper sizing still requires a load calculation (for example, ACCA Manual J\/S or a commercial heat gain analysis). Oversized equipment can short-cycle and under-dehumidify; undersized equipment may struggle on design days.\u003c\/p\u003e\n\u003ch2\u003eWhat the model number tells you\u003c\/h2\u003e\n\u003cp\u003eGoodman packaged unit model numbers encode the nominal size and electrical configuration.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e24\u003c\/strong\u003e = 2 ton nominal size\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3\u003c\/strong\u003e = 13.4 SEER2 efficiency tier in this series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1\u003c\/strong\u003e = 208\/230 V, 1 phase, 60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCore components \u0026amp; performance details\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eCompressor\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003eScroll compressor, single-stage (RLA 10.6, LRA 56.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eCondenser coil\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003eCopper tube \/ aluminum fin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eEvaporator coil\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003eAll-aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eMetering device\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003ePiston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eCondensate drain connection\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e3\/4\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eIndoor blower motor\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003eECM, 1\/2 HP, 3.8 FLA, 5 speeds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eOutdoor fan motor\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e1\/6 HP, 0.95 FLA, 22\" blade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis unit uses R-32 refrigerant (ASHRAE safety class A2L: lower toxicity with mild flammability). Installation and service should follow current local code requirements for A2L refrigerants and be performed by qualified technicians.\u003c\/p\u003e\n\u003ch2\u003eAirflow, ductwork \u0026amp; installation planning\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eDuct openings (supply \/ return)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e16x16 \/ 16x16 (W×H, inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eAirflow configuration\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003eConvertible airflow: horizontal or downflow (packaged AC-only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAn electric heat kit is available as a field-installed option if you need supplemental\/backup heat. Heat kit selection should match local design loads and available electrical capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownflow note:\u003c\/strong\u003e Downflow installs have extra requirements. Per the spec sheet: a Horizontal Duct Cover is required for all downflow installations, and either a Downflow Economizer or a Downflow Conversion Kit is mandatory for all downflow installations.\u003c\/p\u003e\n\u003ch2\u003eElectrical requirements (verify before installation)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003ePower supply\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e208\/230 V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eMinimum Circuit Ampacity (MCA)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e18.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eMaximum Overcurrent Protection (MOCP)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e25 A (use time-delay fuses or HACR breakers per spec sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eAlways verify final electrical data on the unit’s nameplate and size wiring per the National Electrical Code and local codes. Long wire runs may require larger conductor sizes.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eDimensions, clearances \u0026amp; weight\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eCabinet footprint (W×D)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e47\" × 51\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eCabinet height references (A \/ B)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e32\" \/ 34.75\" (chassis size: Medium)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:4px 8px; border:1px solid #ddd; background:#f7f7f7;\"\u003eWeight (operating \/ shipping)\u003c\/th\u003e\n\u003ctd style=\"padding:4px 8px; border:1px solid #ddd;\"\u003e310 \/ 320 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eConstruction, durability \u0026amp; certifications\u003c\/h2\u003e\n\u003ch3\u003eStandard features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e13.4 SEER2 efficiency (2–5 ton sizes)\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient scroll compressor (single-stage per model specs)\u003c\/li\u003e\n\u003cli\u003eMulti-speed ECM indoor blower motor (5 speeds)\u003c\/li\u003e\n\u003cli\u003eConvertible airflow for horizontal or downflow applications\u003c\/li\u003e\n\u003cli\u003eCopper tube \/ aluminum fin condenser coil\u003c\/li\u003e\n\u003cli\u003eAll-aluminum evaporator coil\u003c\/li\u003e\n\u003cli\u003eField-installed electric heat kit option (heat kit size varies by application)\u003c\/li\u003e\n\u003cli\u003eAHRI Certified; UL Listed\u003c\/li\u003e\n\u003cli\u003eENERGY STAR® certified: No (per manufacturer product page)\u003c\/li\u003e\n\u003cli\u003eComfortBridge™ compatibility: No (per manufacturer product page)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHeavy-gauge galvanized-steel cabinet with architectural gray powder-paint finish\u003c\/li\u003e\n\u003cli\u003eAluminum foil-facing internal insulation reinforced with fiberglass scrim\u003c\/li\u003e\n\u003cli\u003eFully insulated blower compartment with convenient access panels\u003c\/li\u003e\n\u003cli\u003eMeets cabinet air leakage requirements when tested to ASHRAE Standard 193\u003c\/li\u003e\n\u003cli\u003eLouvered condenser coil protection\u003c\/li\u003e\n\u003cli\u003eOne footprint across tonnages\u003c\/li\u003e\n\u003cli\u003eWhen properly anchored, meets 2023 Florida Building Code unit integrity requirements for hurricane-type winds (anchor bracket kits available)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e AHRI Certified and UL Listed (per manufacturer specification sheet). AHRI certification helps verify published performance ratings.\u003c\/p\u003e\n\u003ch2\u003eCommon accessories for this chassis size\u003c\/h2\u003e\n\u003cp\u003eDownflow installs have extra requirements. Per the spec sheet: a Horizontal Duct Cover is required for all downflow installations, and either a Downflow Economizer or a Downflow Conversion Kit is mandatory for all downflow installations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConcentric Kit\u003c\/strong\u003e: CDK36\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownflow Economizer (mandatory for some downflow installs)\u003c\/strong\u003e: GPJMED102\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownflow Internal Filter Rack\u003c\/strong\u003e: DDNIFRPCHMM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownflow Manual Damper\u003c\/strong\u003e: PGMDD101\/102\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownflow Motorized Damper\u003c\/strong\u003e: PGMDMD101\/102\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownflow Square to Round\u003c\/strong\u003e: SQRPG101\/102\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownflow Conversion Kit (mandatory for some downflow installs)\u003c\/strong\u003e: DWNFLWCONV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEconomizer Wiring Harness (required for economizer accessories)\u003c\/strong\u003e: 0259L00411\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Horizontal Filter Rack\u003c\/strong\u003e: DPHFRA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontal Duct Cover (required for all downflow installs)\u003c\/strong\u003e: 20464501PDGK\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003ePlus 7 more listed accessories for this chassis size in the manufacturer’s spec sheet.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eWhat you’ll typically need in addition to the unit\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProfessional installation (set\/anchor curb or pad, connect supply\/return ductwork, connect condensate drain, connect power and controls).\u003c\/li\u003e\n\u003cli\u003eA compatible thermostat\/control (often supplied separately).\u003c\/li\u003e\n\u003cli\u003eAn outdoor service disconnect and properly sized branch circuit protection (per MOCP).\u003c\/li\u003e\n\u003cli\u003eIf installed on a roof: the correct roof curb and any downflow\/transition pieces required for your duct layout.\u003c\/li\u003e\n\u003cli\u003eFilters and filter rack solutions as required by your installation (manufacturer lists optional filter rack accessories).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\u003cp\u003e10-Year Parts Limited Warranty available with online registration completed within 60 days of installation (registration not required in California, Florida, or Québec; other limitations and exceptions may apply).\u003c\/p\u003e\n\u003ch2\u003eBefore you order (quick checklist)\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm you need an AC-only packaged unit (not a heat pump).\u003c\/li\u003e\n\u003cli\u003eConfirm nominal size: 2.0 ton and rated capacity 24,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003eConfirm installation orientation\/duct configuration: Convertible airflow: horizontal or downflow (packaged AC-only).\u003c\/li\u003e\n\u003cli\u003eConfirm your electrical service supports the unit’s MCA and MOCP.\u003c\/li\u003e\n\u003cli\u003eIf adding an economizer or downflow setup, confirm the required curb\/duct cover\/relay kits and chassis-specific part numbers.\u003c\/li\u003e\n\u003cli\u003eConfirm local requirements for installing and servicing A2L refrigerants (R-32).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"GPCM32431","offer_id":51549584720192,"sku":"GPCM32431","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/ha26805-bi-03_1.jpg?v=1772455998","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gpcm32431","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}