{"product_id":"goodman-gphm53631-packaged-heat-pump","title":"Goodman GPHM53631 (3-Ton) R-32 Packaged Heat Pump – 15.2 SEER2","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e GPHM53631  |  \u003cstrong\u003eType:\u003c\/strong\u003e R-32 packaged heat pump  |  \u003cstrong\u003eNominal size:\u003c\/strong\u003e 3 ton\u003c\/p\u003e\n\u003cp\u003eGoodman GPHM5 is a higher-efficiency R-32 packaged heat pump (all-in-one outdoor unit) built for ducted cooling and heating with horizontal or downflow airflow configurations. It’s designed for applications where the outdoor unit connects directly to supply\/return ductwork. Sizing should be done with a proper load calculation (tonnage is capacity, not a guaranteed square-foot number).\u003c\/p\u003e\n\u003ch3\u003eSpecs at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency ratings:\u003c\/strong\u003e 15.2 SEER2, 11.4 EER2, 6.80 HSPF2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling capacity:\u003c\/strong\u003e 36,000 BTU\/h total \/ 26,640 BTU\/h sensible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating capacity:\u003c\/strong\u003e 35,400 BTU\/h @ 47°F (COP 3.60); 22,000 BTU\/h @ 17°F (COP 2.26)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor:\u003c\/strong\u003e Scroll (Two-stage); RLA 18.37, LRA 126\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor airflow:\u003c\/strong\u003e 1,200 nominal CFM with multi-speed ECM blower (5 speeds); blower FLA 3.8; motor 3\/4 HP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R-32; factory charge 144 oz (A2L \/ mildly flammable—install and service per applicable codes by qualified technicians)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e 1-phase 208-230V, 60 Hz; minimum circuit ampacity (MCA) 22.8; max overcurrent protection (MOP) 35\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound rating:\u003c\/strong\u003e 76 dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (listed):\u003c\/strong\u003e 492 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e AHRI Certified; UL Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCooling details\u003c\/h3\u003e\n\u003cp\u003eProvides 36,000 BTU\/h of total cooling with 26,640 BTU\/h of sensible capacity. EER2 (11.4) is measured at a single test condition, while SEER2 (15.2) represents seasonal efficiency over a range of conditions—use both to compare models and estimate operating costs.\u003c\/p\u003e\n\u003ch3\u003eHeating details\u003c\/h3\u003e\n\u003cp\u003eHeat pump output is listed at two common rating points: 35,400 BTU\/h at 47°F and 22,000 BTU\/h at 17°F. The COP values (47°F: 3.60, 17°F: 2.26) indicate heating efficiency at those points. In colder climates, many installations add a field-installed electric heat kit for auxiliary\/emergency heat.\u003c\/p\u003e\n\u003ch3\u003eAirflow, comfort \u0026amp; filtration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-speed ECM indoor blower helps match airflow to duct design and comfort needs.\u003c\/li\u003e\n\u003cli\u003eConvertible airflow supports horizontal or downflow duct connections (field-configurable).\u003c\/li\u003e\n\u003cli\u003eMetering device: evaporator TXV; condenser TXV.\u003c\/li\u003e\n\u003cli\u003eFiltration approach depends on your installation (internal\/external filter racks are available as accessories).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction \u0026amp; durability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCondenser coil: copper tube\/aluminum fin. Evaporator coil: all-aluminum (2–4 ton models).\u003c\/li\u003e\n\u003cli\u003eLiquid-line filter drier included.\u003c\/li\u003e\n\u003cli\u003eCompressor: high-efficiency two-stage scroll (2.5–5 ton).\u003c\/li\u003e\n\u003cli\u003eHeavy-gauge galvanized-steel cabinet with two-tone Architectural Gray powder-paint finish and foil-faced internal insulation (reinforced with fiberglass scrim).\u003c\/li\u003e\n\u003cli\u003eFully insulated air-handling compartment with access panels and louvered condenser coil protection.\u003c\/li\u003e\n\u003cli\u003eMeets cabinet air leakage requirements when tested to ASHRAE Standard 193; when properly anchored, meets 2023 Florida Building Code unit integrity requirements for hurricane-type winds (anchor bracket kits available).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation planning (verify before ordering)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis size:\u003c\/strong\u003e Large\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit dimensions:\u003c\/strong\u003e W 47 in × D 51 in × Height A 40 in (Height B 42¾ in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuct openings:\u003c\/strong\u003e Supply 16 x 18 (W×H) \/ Return 16 x 18 (W×H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate drain:\u003c\/strong\u003e 3\/4\" NPT female connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownflow installs:\u003c\/strong\u003e manufacturer notes require horizontal duct covers plus either a downflow conversion kit or a downflow economizer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical planning:\u003c\/strong\u003e use MCA\/MOP values for breaker and wire sizing, and always verify against the unit’s nameplate (S\u0026amp;R plate). Use time-delay fuses or HACR-type breakers as required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon add-ons (sold separately)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectric heat kit (field-installed) for auxiliary\/emergency heat\u003c\/li\u003e\n\u003cli\u003eEconomizer options (fresh air \/ ventilation) — varies by chassis\u003c\/li\u003e\n\u003cli\u003eRoof curb and concentric kit options — varies by chassis\u003c\/li\u003e\n\u003cli\u003eFilter rack options (internal downflow or external horizontal)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat’s included:\u003c\/strong\u003e packaged heat pump unit only (factory charged). Thermostat\/controls, ductwork, curb, economizer, and electric heat kit (if needed) are typically purchased separately and installed by a licensed HVAC professional.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"GPHM53631","offer_id":51549633085760,"sku":"GPHM53631","price":5986.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/ha26805-bi-03_1.jpg?v=1772455998","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gphm53631-packaged-heat-pump","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}