{"product_id":"goodman-gzv6sa2410-capea3022b3-217577960","title":"Goodman | 2 Ton | 15.2 SEER2 | R-32 | Heat Pump Condenser and Evaporator Coil System | GZV6SA2410 + CAPEA3022B3 | 17-1\/2\" Cabinet Width | Upflow\/Downflow | Coil","description":"\u003cdiv class=\"system-intro\"\u003e\n\u003cp\u003eThis Goodman 2 Ton Heat Pump Condenser and Evaporator Coil System pairs the GZV6SA2410 variable-speed inverter-driven R-32 heat pump with the CAPEA3022B3 cased evaporator coil featuring an electronic expansion valve (EEV). The system is AHRI certified (Certificate #217577960) and rated at 15.2 SEER2, 8.0 HSPF2, and 10.0 EER2.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump Condenser:\u003c\/strong\u003e Goodman GZV6SA2410 — 2 Ton, Variable-Speed Inverter-Driven, R-32, Side-Discharge Heat Pump. Rated for 23,200 BTU\/h max cooling and 23,200 BTU\/h max heating at 47°F. Cold Climate ENERGY STAR® Most Efficient certified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil:\u003c\/strong\u003e Goodman CAPEA3022B3 — Upflow\/Downflow, Cased, All-Aluminum Coil with factory-installed Electronic Expansion Valve (EEV). 17-1\/2\" cabinet width, 21\" depth. Optimized for R-32 refrigerant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e The GZV6SA2410 uses R-32 refrigerant with an EEV-equipped indoor coil. The CAPEA3022B3 coil at 21\" depth fits standard attic hatches, but confirm vertical clearance above the coil for the suction line bend radius — R-32 suction pressures run higher than R-410A at the same conditions, so use ACR-rated copper sized per the spec sheet (3\/4\" OD suction for this 2-ton unit).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After brazing with nitrogen purge, evacuate to 350 microns and hold. The EEV in the CAPEA\/CHPEA coil communicates with the outdoor unit's inverter board — a moisture-contaminated system will cause the EEV stepper motor to hunt erratically within 6-12 months, generating nuisance fault codes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital micron gauge to verify deep vacuum. After system startup, confirm the outdoor unit's seven-segment LED shows no active fault codes and verify subcooling reads 12±1°F at the service valve with an R-32 calibrated digital manifold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable) under ASHRAE 34. EPA Section 608 certification is required. Verify local code adoption of UL 60335-2-40. The system ships with 74 oz of R-32 factory charge sized for 15 ft of 3\/8\" liquid line — adjust per the installation instructions for actual lineset length.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerified Efficiency:\u003c\/strong\u003e AHRI-certified 15.2 SEER2 \/ 8.0 HSPF2 \/ 10.0 EER2 ratings ensure consistent, tested performance in both cooling and heating modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Compressor:\u003c\/strong\u003e The swing compressor modulates output to match the actual load, reducing temperature swings and energy consumption compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675, which is approximately 68% lower than R-410A (GWP 2,088), aligning with EPA AIM Act requirements and future refrigerant regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The outdoor unit features a high-density compressor sound blanket, digitally commutated fan motor, and a selectable quiet mode that reduces sound output to as low as 45 dBA — suitable for installations near bedrooms or patios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Aluminum Evaporator Coil:\u003c\/strong\u003e The indoor coil uses an all-aluminum construction with an R-32 sensor designed for the life span of the coil, paired with a factory-installed EEV for precise refrigerant metering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate #\u003c\/td\u003e\n\u003ctd\u003e217577960\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eHeat Pump Condenser and Evaporator Coil System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e2 Ton (24,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e23,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 47°F (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e23,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd\u003e14,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e74 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e36-5\/8\" × 13-3\/4\" × 27-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight\u003c\/td\u003e\n\u003ctd\u003e122 lbs (137 lbs shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical (Outdoor)\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Overcurrent\u003c\/td\u003e\n\u003ctd\u003e16.8A \/ 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e17-1\/2\" × 21\" × 22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Shipping Weight\u003c\/td\u003e\n\u003ctd\u003e48 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088 GWP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnician certification required for refrigerant handling, recovery, and disposal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets EPA AIM Act phasedown requirements; compliant with DOE 2023 efficiency standards (SEER2\/HSPF2 metrics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eCertificate #217577960 — independently tested and verified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR® Status\u003c\/td\u003e\n\u003ctd\u003eMeets ENERGY STAR® criteria when properly matched with qualifying indoor components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eThis configuration may not independently meet IRA tax credit efficiency thresholds. Verify current requirements at energystar.gov or consult a tax professional.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. Online registration at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003ewww.goodmanmfg.com\u003c\/a\u003e must be completed within 60 days of installation to activate the full registered warranty coverage. Registration is not required in California, Florida, or Québec.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA2410):\u003c\/strong\u003e \u003cem\u003eUnregistered:\u003c\/em\u003e 5-year parts limited warranty from the installation date. \u003cem\u003eRegistered (within 60 days):\u003c\/em\u003e 10-year parts limited warranty; if the compressor fails within 10 years, Daikin will furnish a new equivalent unit to replace the entire outdoor unit (one-time replacement). Warranty applies to owner-occupied residences only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3022B3):\u003c\/strong\u003e \u003cem\u003eUnregistered:\u003c\/em\u003e 5-year parts limited warranty from the installation date. \u003cem\u003eRegistered (within 60 days):\u003c\/em\u003e 10-year parts limited warranty. Warranty applies to owner-occupied residences only.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eLabor, refrigerant, freight, and other service costs are not covered under these warranties. Refer to each component's full warranty document for complete terms, conditions, limitations, and exclusions.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51881962832192,"sku":"GZV6SA2410-CAPEA3022B3-217577960","price":3569.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/hgyfyugukd_2.jpg?v=1777799215","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa2410-capea3022b3-217577960","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}