{"product_id":"goodman-gzv6sa2410-grvs800604bu-capea3022c3","title":"Goodman 2 Ton 18.0 SEER2 R-32 Dual Fuel System | GZV6SA2410 + GRVS800604BU + CAPEA3022C3 | 60,000 BTU Upflow\/Horizontal Single-Stage Variable-Speed ECM Ultra Low NOx 80% AFUE Furnace | 21\" Wide Upflow\/Downflow Coil","description":"\u003cdiv style=\"font-family:Arial,sans-serif;line-height:1.6;color:#333;\"\u003e\n\u003cp\u003eThis AHRI-certified Dual Fuel System pairs the Goodman GZV6SA2410 2-ton, 18.0 SEER2, 8.5 HSPF2 variable-speed inverter-driven R-32 heat pump with the GRVS800604BU 80% AFUE single-stage gas furnace (60,000 BTU\/h input) and the CAPEA3022C3 cased upflow\/downflow evaporator coil with factory-installed EEV. This combination delivers efficient all-season comfort: variable-speed heat pump operation for moderate temperatures and automatic switchover to gas furnace heating when outdoor conditions drop below the balance point. AHRI Certified Reference Number: 215487293.\u003c\/p\u003e\n\u003cp style=\"background:#fff3cd;border:1px solid #ffc107;padding:10px;border-radius:4px;\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA2410\u003c\/strong\u003e — Goodman 2-Ton, 18.0 SEER2 \/ 8.5 HSPF2, Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser (23,200 BTU\/h cooling, 23,200 BTU\/h heating at 47°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVS800604BU\u003c\/strong\u003e — Goodman 60,000 BTU\/h Input (48,000 BTU\/h Output), 80% AFUE, Single-Stage, Variable-Speed ECM, Upflow\/Horizontal Gas Furnace (Ultra Low NOx)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3022C3\u003c\/strong\u003e — Goodman 2.5 Ton Nominal, Cased Upflow\/Downflow, All-Aluminum Evaporator Coil with Factory-Installed EEV (21\" W × 21\" D × 22\" H)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7f0;border-left:4px solid #2e7d32;padding:16px;margin:16px 0;\"\u003e\n\u003ch4 style=\"color:#2e7d32;margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e Upflow 80% AFUE furnaces with the GZV6SA2410 heat pump use a conventional metal flue venting arrangement. In tight mechanical closets, the 60,000 BTU furnace's single-wall vent connector requires minimum 6-inch clearance to combustibles — verify this against the coil height (22\") stacked above the furnace before committing to the layout.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Install a combustion air proving switch if the furnace is in a confined space. Check the dual fuel changeover setpoint (typically ~35°F outdoor ambient) to ensure the system doesn't short-cycle between heat pump and gas heat during shoulder-season temperature swings, which causes premature contactor wear.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e After commissioning, verify combustion with a digital combustion analyzer: CO should be below 100 ppm air-free in flue gases, and draft should read –0.02\" WC or more negative at the draft hood. Confirm heat pump subcooling at 12±1°F per GZV6S specs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e EPA Section 608 certification is required for R-32 refrigerant handling. Local building codes may require a single-stage gas valve for this installation — verify with the Authority Having Jurisdiction (AHJ). R-32 has a GWP of 675, roughly 68% lower than R-410A, supporting 2025 AIM Act phase-down targets.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Performance:\u003c\/strong\u003e 18.0 SEER2 and 8.5 HSPF2 ratings with variable-speed inverter technology reduce energy consumption compared to single-speed systems by running at lower speeds for longer periods, matching output to actual demand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant:\u003c\/strong\u003e GWP of 675 — approximately 68% lower than R-410A (GWP 2,088). Supports 2025 EPA AIM Act HFC phase-down requirements and reduces direct greenhouse gas emission potential.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Operation:\u003c\/strong\u003e The swing compressor adjusts speed continuously rather than cycling on\/off, providing tighter temperature control (±0.5°F vs. ±2°F for single-stage), reduced humidity, and lower sound levels (as low as 45 dBA in Quiet Mode).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically switches between heat pump and 60,000 BTU\/h gas furnace based on outdoor temperature, optimizing operating cost by using the most efficient heat source for current conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System:\u003c\/strong\u003e EEV-equipped indoor components work with the outdoor unit's control board to optimize refrigerant flow and system performance. Compatible with Goodman GTST connected thermostat for advanced diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Capable:\u003c\/strong\u003e ENERGY STAR Most Efficient 2025 (Cold Climate) certified. Heat pump operates down to -10°F ambient, delivering 14,200 BTU\/h at 5°F for reliable heating in harsh conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0;\" border=\"1\" cellpadding=\"8\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e0e0e0;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAHRI Certificate Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e215487293\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Capacity (95°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23,200 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Capacity (47°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23,200 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Capacity (5°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14,200 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace AFUE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Unit Dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36⅝\" × 13¾\" × 27⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Unit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEvaporator Coil Dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21\" × 21\" × 22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEvaporator Coil Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51 lbs (shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion Device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Unit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin. Circuit Ampacity (Outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Overcurrent Protection (Outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLiquid Line Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuction Line Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e¾\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFactory Charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e74 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound Level (Quiet Mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAs low as 45 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#fff3cd;font-size:0.9em;\"\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0;\" border=\"1\" cellpadding=\"8\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e0e0e0;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGlobal Warming Potential (GWP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e675 (~68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEPA 608 Certification Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — Section 608 certification required for purchase, handling, and service of R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAHRI Certified\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — AHRI Certificate #215487293\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eETL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eENERGY STAR®\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eENERGY STAR Most Efficient 2025 (Cold Climate Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRegional Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 regional efficiency standards for all U.S. regions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFederal Tax Credit Eligibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem may qualify for federal tax credits under IRS Section 25C for qualifying high-efficiency HVAC equipment — verify current thresholds and requirements with a qualified tax professional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNOx Emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltra Low NOx — Compliant with California South Coast AQMD Rule 1111 (14 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty from Daikin Comfort Technologies. Online registration within 60 days of installation is strongly recommended to obtain extended coverage.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA2410):\u003c\/strong\u003e \u003cem\u003eUnregistered:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eRegistered (within 60 days):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within 10 years, Daikin will furnish a new equivalent replacement unit (one-time). Register at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003ewww.goodmanmfg.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVS800604BU):\u003c\/strong\u003e \u003cem\u003eUnregistered:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty; 5-Year Parts Limited Warranty. \u003cem\u003eRegistered (within 60 days):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (as long as original owner resides in home); 10-Year Unit Replacement Limited Warranty (for heat exchanger failure within 10 years); 10-Year Parts Limited Warranty. Register at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003ewww.goodmanmfg.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3022C3):\u003c\/strong\u003e \u003cem\u003eUnregistered:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eRegistered (within 60 days):\u003c\/em\u003e 10-Year Parts Limited Warranty. Register at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003ewww.goodmanmfg.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;color:#666;\"\u003eWarranty coverage applies to owner-occupied residences. Online registration is not required in California, Florida, or Québec. Duration of coverage in Texas and Florida may differ. Refer to individual component warranty documents for complete terms, limitations, and exclusions.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51881992683840,"sku":"GZV6SA2410-GRVS800604BU-CAPEA3022C3","price":5971.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/GHCYUKCJHVKJtitled.jpg?v=1777345299","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa2410-grvs800604bu-capea3022c3","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}