{"product_id":"goodman-gzv6sa3010-capea3022c3-gdvm971005cn-dual-fuel-216611823","title":"Goodman 2.5 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV6SA3010 + CAPEA3022C3 + GDVM971005CN | 21\" Depth Upflow\/Downflow Coil | 100,000 BTU Downflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;color:#333;line-height:1.6;max-width:960px;\"\u003e\n\n\u003ch2 style=\"color:#222;margin-bottom:4px;\"\u003eGoodman 2.5 Ton Dual Fuel System\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #216611823) pairs the Goodman GZV6SA3010 2.5-ton variable-speed heat pump with the GDVM971005CN 97% AFUE gas furnace and CAPEA3022C3 cased evaporator coil. Rated at 17.5 SEER2 and 8.5 HSPF2 for the heat pump mode, the system uses R-32 refrigerant (GWP 675) and automatically transitions between electric heat pump and gas furnace operation based on outdoor temperature. This system is not ENERGY STAR® Cold Climate or Most Efficient certified.\u003c\/p\u003e\n\u003cp style=\"background:#eef6ff;padding:10px 14px;border-radius:6px;font-size:0.95em;\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the “Resources (System Manuals and Warranty)” Tab above on this page.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#333;border-bottom:2px solid #e0e0e0;padding-bottom:8px;\"\u003eSystem Components\u003c\/h3\u003e\n\u003cul style=\"line-height:1.8;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3010\u003c\/strong\u003e — 2.5-Ton Variable-Speed Heat Pump Condenser (R-32, 17.5 SEER2 \/ 8.5 HSPF2), 28,400 BTU\/h cooling at 95°F, 28,800 BTU\/h heating at 47°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3022C3\u003c\/strong\u003e — Cased Upflow\/Downflow Evaporator Coil with factory-installed EEV, all-aluminum construction, R-32 optimized, 21\" W x 21\" D x 22\" H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVM971005CN\u003c\/strong\u003e — 100,000 BTU\/h 97% AFUE Downflow\/Horizontal Gas Furnace, Modulating gas valve, Variable-Speed ECM blower motor, 21\" cabinet width, Natural Gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f9f6ee;border-left:4px solid #c27b00;padding:16px 20px;margin:24px 0;border-radius:0 8px 8px 0;\"\u003e\n\u003ch4 style=\"margin:0 0 10px;color:#c27b00;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e In a dual fuel configuration, the GDVM971005CN furnace (Downflow\/Horizontal) paired with the CAPEA3022C3 upflow\/downflow coil requires precise clearance planning. The 21\" coil depth must align with the 21\" furnace cabinet width, and the Flush fit designation means the coil-to-furnace transition must be verified for air leakage at the plenum connection.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e On dual fuel changeover, confirm the outdoor thermostat lockout (balance point) is set correctly for the climate zone. If the heat pump operates below its economic balance point without switching to the 97% AFUE gas furnace, the homeowner faces inflated electric bills and compressor stress. Verify subcooling at the service valve reads 14±1°F per the GZV6S specification—an incorrect charge causes nuisance high-pressure lockouts 6–12 months post-install.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Evacuate to ≤350 microns using a digital micron gauge before releasing the R-32 charge. R-32’s higher operating pressure compared to R-410A demands verified torque on all flare connections using a calibrated torque wrench (per manufacturer torque chart). Confirm gas furnace combustion analysis with a digital analyzer: CO \u0026lt;100 ppm in flue, O₂ between 6–9%.\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable) under ASHRAE 34. Verify compliance with local Mechanical Code amendments for A2L refrigerants, including charge limits in occupied spaces and required leak detection. EPA Section 608 certification is mandatory. Gas furnace installation must comply with local fuel gas codes and the Natural Gas emission requirements for the applicable air quality district.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#333;border-bottom:2px solid #e0e0e0;padding-bottom:8px;\"\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul style=\"line-height:1.8;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Dual Fuel Operation:\u003c\/strong\u003e The 17.5 SEER2 \/ 8.5 HSPF2 heat pump automatically transitions to the 97% AFUE gas furnace when outdoor temperatures drop below the programmable balance point, optimizing energy costs across all seasons.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—68% lower than R-410A (GWP 2,088). This reduces the system’s direct environmental impact while delivering equivalent or improved heat transfer efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S outdoor unit uses a variable-speed swing compressor that modulates capacity to match the actual load, reducing cycling losses and delivering tighter temperature control compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Aluminum Evaporator Coil:\u003c\/strong\u003e The CAPEA3022C3 features an all-aluminum evaporator coil with a factory-installed EEV (Electronic Expansion Valve) for precise refrigerant metering across varying load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed ECM Furnace Blower:\u003c\/strong\u003e The GDVM971005CN furnace uses a variable-speed ecm blower motor with modulating gas valve operation, providing consistent airflow across heating and cooling modes while minimizing electrical consumption at part load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#333;border-bottom:2px solid #e0e0e0;padding-bottom:8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;\"\u003eOutdoor Unit (GZV6SA3010)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;\"\u003eEvaporator Coil (CAPEA3022C3)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;\"\u003eGas Furnace (GDVM971005CN)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSEER2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17.5\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eEER2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10.0\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8.5\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eAFUE\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e28,400\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eHeating Capacity @ 47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e28,800\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eHeating Capacity @ 5°F (BTU\/h)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17,300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFurnace Input (BTU\/h)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e100,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eR-32\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eR-32\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eExpansion Device\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eEEV\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eEEV\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e36⅝\" x 13¾\" x 27⅜\"\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e21\" W x 21\" D x 22\" H\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e21\" Cabinet Width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eWeight \/ Ship Weight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e132 \/ 147 lbs\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e— \/ 51 lbs\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRefrigerant Line (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e⅜\" \/ ⅞\"\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFactory Charge\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e76 oz\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eBlower Motor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"4\" style=\"border:1px solid #ddd;padding:10px;font-size:0.9em;color:#666;\"\u003eNote: See “Resources (System Manuals and Warranty)” Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#333;border-bottom:2px solid #e0e0e0;padding-bottom:8px;\"\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;\"\u003eCategory\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e675 (68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCertification required for handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eYes — Certificate #216611823\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eMeets DOE 2023 minimum efficiency standards for all U.S. regions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFurnace NOx Emissions\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eThis system may qualify for federal tax credits under the Inflation Reduction Act (IRA) for high-efficiency HVAC equipment. Consult a qualified tax professional and visit \u003ca href=\"https:\/\/www.goodmanmfg.com\/resources\/tax-credit\"\u003egoodmanmfg.com\/resources\/tax-credit\u003c\/a\u003e for current eligibility requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#333;border-bottom:2px solid #e0e0e0;padding-bottom:8px;\"\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty from Daikin Comfort Technologies. Registration within 60 days of installation is strongly recommended to obtain the full warranty coverage.\u003c\/p\u003e\n\u003cul style=\"line-height:1.8;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3010):\u003c\/strong\u003e Unregistered—5-Year Parts Limited Warranty. Registered (within 60 days at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003egoodmanmfg.com\u003c\/a\u003e)—10-Year Parts Limited Warranty. If the compressor fails within 10 years on a registered unit, Daikin will furnish a new replacement unit (one-time).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3022C3):\u003c\/strong\u003e Unregistered—5-Year Parts Limited Warranty. Registered (within 60 days)—10-Year Parts Limited Warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GDVM971005CN):\u003c\/strong\u003e Unregistered—20-Year Heat Exchanger Limited Warranty plus 5-Year Parts Limited Warranty on all other components. Registered (within 60 days)—Extended Heat Exchanger Limited Warranty (with unit replacement provisions) plus 10-Year Parts Limited Warranty on all other components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;color:#666;\"\u003eWarranty coverage applies to owner-occupied residences installed within the United States, its territories, or Canada. Units must be installed by a qualified HVAC contractor adhering to all applicable codes. Complete warranty terms available at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003egoodmanmfg.com\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51882536468800,"sku":"GZV6SA3010-CAPEA3022C3-GDVM971005CN-216611823","price":7511.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa3010-capea3022c3-gdvm971005cn-dual-fuel-216611823","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}