{"product_id":"goodman-gzv6sa3010-capea3626b3-mbvk12bp1x00-216611797-hp-coil-blower","title":"Goodman 2.5 Ton 17.5 SEER2 R-32 Central Heat Pump Split System with Evaporator Coil \u0026 Modular Blower - GZV6SA3010 + CAPEA3626B3 + MBVK12BP1X00 - 17½\" Depth Upflow\/Downflow Cased Coil - Multi-Positional Modular Blower","description":"\u003cdiv style=\"font-family:Arial,sans-serif;max-width:960px;margin:0 auto;color:#333;\"\u003e\n\n\u003c!-- SECTION 1: INTRO --\u003e\n\u003cdiv style=\"margin-bottom:24px;\"\u003e\n\u003cp\u003eThis AHRI-certified Goodman 2.5 Ton Central Heat Pump Split System with Evaporator Coil and Modular Blower delivers 17.5 SEER2 and 8.5 HSPF2 efficiency using R-32 refrigerant (GWP 675). The system pairs the GZV6SA3010 variable-speed heat pump condenser with the CAPEA3626B3 upflow\/downflow evaporator coil and the MBVK12BP1X00 variable-speed ECM modular blower, verified under AHRI Certificate #216611797. This configuration is Energy Star Cold Climate certified, providing reliable heating performance down to -10°F.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- SECTION 2: COMPONENTS LIST --\u003e\n\u003cdiv style=\"margin-bottom:24px;\"\u003e\n\u003ch3 style=\"color:#1a1a1a;border-bottom:2px solid #cc0000;padding-bottom:6px;\"\u003eSystem Components\u003c\/h3\u003e\n\u003cul style=\"line-height:1.8;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3010\u003c\/strong\u003e — 2.5 Ton Variable-Speed Inverter-Driven R-32 Side-Discharge Heat Pump Condenser (28,400 BTU\/h Cooling \/ 28,800 BTU\/h Heating @ 47°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626B3\u003c\/strong\u003e — Cased Upflow\/Downflow Evaporator Coil with EEV (17½\" W × 21\" D × 26\" H, Upflow\/Downflow Configuration)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMBVK12BP1X00\u003c\/strong\u003e — Variable-Speed ECM Multi-Positional Modular Blower (17½\" W × 21\" D × 26\" H, ½ HP Motor)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFit:\u003c\/strong\u003e Flush — \u003cstrong\u003eAHRI Certificate:\u003c\/strong\u003e #216611797\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- SECTION 3: PRO-INSTALLER TIP --\u003e\n\u003cdiv style=\"background:#f9f5ee;border-left:4px solid #cc0000;padding:16px 20px;margin-bottom:24px;\"\u003e\n\u003ch3 style=\"color:#cc0000;margin-top:0;\"\u003ePro-Installer Tip\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e The GZV6S series uses R-32 refrigerant with an EEV on both the outdoor unit and the CAPEA3626B3 indoor coil. During installation, the two-piece modular blower and coil assembly requires precise alignment — a Flush fit between the MBVK12BP1X00 blower (17½\" cabinet) and the CAPEA3626B3 coil (17½\" cabinet) demands careful attention to transition fitment and seal integrity to prevent air bypass.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e Pull a deep vacuum to 350 microns or below and hold for 15 minutes before charging. R-32 operates at approximately 12% higher discharge pressures than R-410A, making moisture contamination a more significant concern. Verify subcooling at 14±1°F at the service valve. A properly evacuated system prevents non-condensable gas accumulation that causes high head pressure nuisance calls 6-12 months post-installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital micron gauge (not a compound gauge) to verify vacuum depth. Confirm subcooling with a digital manifold that compensates for R-32 properties. Verify blower airflow using the onboard CFM indicator — the variable-speed ECM motor should be configured for the matched tonnage in communicating mode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is an A2L mildly flammable refrigerant — ensure all installation practices comply with UL 60335-2-40 and local mechanical code requirements for A2L refrigerant systems. EPA Section 608 certification is required. This system meets 2023 Florida Building Code unit integrity requirements when properly anchored.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- SECTION 4: KEY BENEFITS --\u003e\n\u003cdiv style=\"margin-bottom:24px;\"\u003e\n\u003ch3 style=\"color:#1a1a1a;border-bottom:2px solid #cc0000;padding-bottom:6px;\"\u003eKey Benefits\u003c\/h3\u003e\n\u003cul style=\"line-height:1.8;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e17.5 SEER2 \/ 8.5 HSPF2 Efficiency\u003c\/strong\u003e — Variable-speed inverter compressor modulates capacity from low-stage to full-stage, reducing energy consumption during partial-load conditions that account for the majority of annual runtime hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant (GWP 675)\u003c\/strong\u003e — R-32 has 68% lower global warming potential than R-410A (GWP 2,088), uses approximately 20% less refrigerant charge by weight, and delivers improved thermodynamic efficiency at the same operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance\u003c\/strong\u003e — Energy Star Cold Climate certified with continuous heating capacity down to -10°F (17,300 BTU\/h @ 5°F), reducing reliance on supplemental electric heat strips in the modular blower.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation with Three-Level Sound Control\u003c\/strong\u003e — Normal-mode sound rating of 67 dBA (cooling) with field-selectable quiet mode (as low as 45 dBA), well below most municipal nighttime noise ordinances of 55 dBA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed ECM Blower Motor\u003c\/strong\u003e — The MBVK12BP1X00 modular blower provides constant CFM across a wide range of static pressures, improving dehumidification control and maintaining consistent comfort in communicating mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Aluminum Evaporator Coil with EEV\u003c\/strong\u003e — The CAPEA3626B3 features an all-aluminum coil optimized for R-32 with an integrated electronic expansion valve for precise superheat control across the full modulation range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003c!-- SECTION 5: TECHNICAL SPECIFICATIONS TABLE --\u003e\n\u003cdiv style=\"margin-bottom:24px;\"\u003e\n\u003ch3 style=\"color:#1a1a1a;border-bottom:2px solid #cc0000;padding-bottom:6px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e216611797\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eSystem Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eCentral Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e2.5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e17.5 \/ 10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eCooling Capacity (95°F)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e28,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e28,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eHeating Capacity (5°F)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e17,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eRefrigerant \/ Charge\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eR-32 \/ 76 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eExpansion Device\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eCoil-to-Blower Fit\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eFlush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\" colspan=\"2\"\u003eOutdoor Unit — GZV6SA3010\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eOutdoor Unit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e36⅝\" × 13¾\" × 27⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eOutdoor Unit Weight \/ Ship Weight\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e132 lbs \/ 147 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eSound Level (Cooling \/ Heating)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e67 dBA \/ 70 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eRefrigerant Lines (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e⅜\" \/ ⅞\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\" colspan=\"2\"\u003eEvaporator Coil — CAPEA3626B3\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eCoil Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e17½\" × 21\" × 26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eCoil Ship Weight\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e54 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\" colspan=\"2\"\u003eModular Blower — MBVK12BP1X00\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eBlower Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eMulti-Positional (Horizontal or Vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eBlower Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e17½\" × 21\" × 26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eBlower Motor\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e½ HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eBlower Ship Weight\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e67 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size:12px;color:#666;margin-top:8px;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- SECTION 6: COMPLIANCE \u0026 ENVIRONMENT TABLE --\u003e\n\u003cdiv style=\"margin-bottom:24px;\"\u003e\n\u003ch3 style=\"color:#1a1a1a;border-bottom:2px solid #cc0000;padding-bottom:6px;\"\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e675 (68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRequired for purchase, installation, and service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eUL Safety Compliance\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eUL 60335-2-40 (A2L Refrigerant Systems)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eYes (Cold Climate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eMeets DOE 2023 minimum efficiency standards for all U.S. regions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;font-weight:bold;\"\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eThis system may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (25C). Consult a qualified tax professional for eligibility based on your specific situation and current IRS guidelines.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003c!-- SECTION 7: WARRANTY \u0026 REGISTRATION --\u003e\n\u003cdiv style=\"margin-bottom:24px;\"\u003e\n\u003ch3 style=\"color:#1a1a1a;border-bottom:2px solid #cc0000;padding-bottom:6px;\"\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. Online registration must be completed within 60 days of installation to receive the full warranty coverage. Registration is not required in California, Florida, or Québec.\u003c\/p\u003e\n\u003cul style=\"line-height:1.8;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3010 (Heat Pump Condenser):\u003c\/strong\u003e 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty when registered online within 60 days of installation. Without registration, coverage defaults to a reduced term. One-time Compressor Replacement coverage is available for years 11-99 through an ASURE Extend Service Plan. Duration of coverage may differ in Texas and Florida.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3626B3 (Evaporator Coil):\u003c\/strong\u003e 10-Year Parts Limited Warranty when registered online within 60 days of installation. Without timely registration, a reduced warranty term applies. Duration of coverage may differ in Texas and Florida.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMBVK12BP1X00 (Modular Blower):\u003c\/strong\u003e 10-Year Parts Limited Warranty when registered online within 60 days of installation. Without timely registration, a reduced warranty term applies. Duration of coverage may differ in Texas and Florida.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:12px;color:#666;\"\u003eWarranty terms are subject to limitations and exclusions. Refer to the manufacturer's complete warranty documents for full details, rights, and obligations. Changes in law, regulations, or technology may affect warranty terms.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51882635788608,"sku":"GZV6SA3010-CAPEA3626B3-MBVK12BP1X00-216611797","price":4893.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/btnfthgytjtyjtyjed.jpg?v=1777798322","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa3010-capea3626b3-mbvk12bp1x00-216611797-hp-coil-blower","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}