{"product_id":"goodman-gzv6sa3010-chpea3026b3-gcvc960403bn-dual-fuel-215488209","title":"Goodman 2.5 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV6SA3010 + CHPEA3026B3 + GCVC960403BN | 26\" Width Horizontal Coil | 40,000 BTU Downflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace | Communicating","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;color:#333;line-height:1.6;max-width:960px;\"\u003e\n\n\u003ch2 style=\"color:#222;margin-bottom:4px;\"\u003eGoodman 2.5 Ton Dual Fuel System\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215488209) pairs the Goodman GZV6SA3010 2.5-ton variable-speed heat pump with the GCVC960403BN 96% AFUE gas furnace and CHPEA3026B3 cased evaporator coil. Rated at 17.5 SEER2 and 8.5 HSPF2 for the heat pump mode, the system uses R-32 refrigerant (GWP 675) and automatically transitions between electric heat pump and gas furnace operation based on outdoor temperature. This system supports ComfortBridge™ communicating technology, enabling automatic airflow calibration and enhanced diagnostic reporting between the outdoor unit, furnace, and indoor coil. This system is not ENERGY STAR® Cold Climate or Most Efficient certified.\u003c\/p\u003e\n\u003cp style=\"background:#eef6ff;padding:10px 14px;border-radius:6px;font-size:0.95em;\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the “Resources (System Manuals and Warranty)” Tab above on this page.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#333;border-bottom:2px solid #e0e0e0;padding-bottom:8px;\"\u003eSystem Components\u003c\/h3\u003e\n\u003cul style=\"line-height:1.8;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3010\u003c\/strong\u003e — 2.5-Ton Variable-Speed Heat Pump Condenser (R-32, 17.5 SEER2 \/ 8.5 HSPF2), 28,400 BTU\/h cooling at 95°F, 28,800 BTU\/h heating at 47°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA3026B3\u003c\/strong\u003e — Cased Horizontal Evaporator Coil with factory-installed EEV, all-aluminum construction, R-32 optimized, 26\" W x 21\" D x 17½\" H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVC960403BN\u003c\/strong\u003e — 40,000 BTU\/h 96% AFUE Downflow\/Horizontal Gas Furnace, Two-Stage gas valve, Variable-Speed ECM blower motor, 17½\" cabinet width, Natural Gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f9f6ee;border-left:4px solid #c27b00;padding:16px 20px;margin:24px 0;border-radius:0 8px 8px 0;\"\u003e\n\u003ch4 style=\"margin:0 0 10px;color:#c27b00;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e Horizontal coil installations in attic spaces with the CHPEA3026B3 require careful attention to condensate routing. The 26\" width of this horizontal coil demands adequate clearance on both service-access and drain-pan sides, and low-pitch attic rafters can limit the available workspace for brazing the ⅜\" liquid and ⅞\" suction connections.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e Install a secondary float switch on the auxiliary drain pan and verify the primary condensate trap has a minimum 2\" water column seal. R-32 systems operate at marginally higher discharge pressures than R-410A, so confirm subcooling at the service valve reads 14±1°F per the manufacturer specification. An incorrect charge will surface as a nuisance high-pressure lockout 6–12 months post-install, typically during the first sustained heat event.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital micron gauge (target ≤350 microns) during evacuation—R-32’s lower GWP of 675 does not exempt it from proper evacuation standards. Verify superheat and subcooling with a calibrated digital manifold rather than analog gauges.\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is an A2L (mildly flammable) refrigerant. Ensure compliance with ASHRAE 34 safety classifications and any local amendments to the Mechanical Code regarding A2L refrigerant charge limits in occupied spaces. EPA Section 608 certification is required for handling.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#333;border-bottom:2px solid #e0e0e0;padding-bottom:8px;\"\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul style=\"line-height:1.8;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Dual Fuel Operation:\u003c\/strong\u003e The 17.5 SEER2 \/ 8.5 HSPF2 heat pump automatically transitions to the 96% AFUE gas furnace when outdoor temperatures drop below the programmable balance point, optimizing energy costs across all seasons.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—68% lower than R-410A (GWP 2,088). This reduces the system’s direct environmental impact while delivering equivalent or improved heat transfer efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S outdoor unit uses a variable-speed swing compressor that modulates capacity to match the actual load, reducing cycling losses and delivering tighter temperature control compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Aluminum Evaporator Coil:\u003c\/strong\u003e The CHPEA3026B3 features an all-aluminum evaporator coil with a factory-installed EEV (Electronic Expansion Valve) for precise refrigerant metering across varying load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed ECM Furnace Blower:\u003c\/strong\u003e The GCVC960403BN furnace uses a variable-speed ecm blower motor with two-stage gas valve operation, providing consistent airflow across heating and cooling modes while minimizing electrical consumption at part load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfortBridge™ Communication:\u003c\/strong\u003e System components communicate digitally for automatic airflow calibration, real-time fault diagnostics, and optimized staging between the heat pump and gas furnace modes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#333;border-bottom:2px solid #e0e0e0;padding-bottom:8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;\"\u003eOutdoor Unit (GZV6SA3010)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;\"\u003eEvaporator Coil (CHPEA3026B3)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;\"\u003eGas Furnace (GCVC960403BN)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSEER2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17.5\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eEER2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e10.0\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8.5\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eAFUE\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e28,400\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eHeating Capacity @ 47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e28,800\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eHeating Capacity @ 5°F (BTU\/h)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17,300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFurnace Input (BTU\/h)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e40,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eR-32\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eR-32\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eExpansion Device\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eEEV\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eEEV\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e36⅝\" x 13¾\" x 27⅜\"\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e26\" W x 21\" D x 17½\" H\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17½\" Cabinet Width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eWeight \/ Ship Weight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e132 \/ 147 lbs\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e— \/ 63 lbs\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRefrigerant Line (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e⅜\" \/ ⅞\"\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFactory Charge\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e76 oz\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eBlower Motor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"4\" style=\"border:1px solid #ddd;padding:10px;font-size:0.9em;color:#666;\"\u003eNote: See “Resources (System Manuals and Warranty)” Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#333;border-bottom:2px solid #e0e0e0;padding-bottom:8px;\"\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;\"\u003eCategory\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e675 (68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCertification required for handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eYes — Certificate #215488209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eMeets DOE 2023 minimum efficiency standards for all U.S. regions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFurnace NOx Emissions\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eThis system may qualify for federal tax credits under the Inflation Reduction Act (IRA) for high-efficiency HVAC equipment. Consult a qualified tax professional and visit \u003ca href=\"https:\/\/www.goodmanmfg.com\/resources\/tax-credit\"\u003egoodmanmfg.com\/resources\/tax-credit\u003c\/a\u003e for current eligibility requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#333;border-bottom:2px solid #e0e0e0;padding-bottom:8px;\"\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty from Daikin Comfort Technologies. Registration within 60 days of installation is strongly recommended to obtain the full warranty coverage.\u003c\/p\u003e\n\u003cul style=\"line-height:1.8;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3010):\u003c\/strong\u003e Unregistered—5-Year Parts Limited Warranty. Registered (within 60 days at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003egoodmanmfg.com\u003c\/a\u003e)—10-Year Parts Limited Warranty. If the compressor fails within 10 years on a registered unit, Daikin will furnish a new replacement unit (one-time).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA3026B3):\u003c\/strong\u003e Unregistered—5-Year Parts Limited Warranty. Registered (within 60 days)—10-Year Parts Limited Warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GCVC960403BN):\u003c\/strong\u003e Unregistered—20-Year Heat Exchanger Limited Warranty plus 5-Year Parts Limited Warranty on all other components. Registered (within 60 days)—Extended Heat Exchanger Limited Warranty (with unit replacement provisions) plus 10-Year Parts Limited Warranty on all other components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;color:#666;\"\u003eWarranty coverage applies to owner-occupied residences installed within the United States, its territories, or Canada. Units must be installed by a qualified HVAC contractor adhering to all applicable codes. Complete warranty terms available at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003egoodmanmfg.com\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51882531258688,"sku":"GZV6SA3010-CHPEA3026B3-GCVC960403BN-215488209","price":6075.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/gmgmgmgmgmgmg.jpg?v=1777591260","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa3010-chpea3026b3-gcvc960403bn-dual-fuel-215488209","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}