{"product_id":"goodman-gzv6sa3010-chpea3026c3-gmvc800604bn-dual-fuel-215488204","title":"Goodman 2.5 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV6SA3010 + CHPEA3026C3 + GMVC800604BN | 26\" Wide 21\" Tall Horizontal Cased Coil | 60,000 BTU\/h Upflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace | Communicating","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 2.5 Ton 17.5 SEER2 R-32 Dual Fuel System\u003c\/h2\u003e\n\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215488204) pairs the Goodman GZV6SA3010 2.5-ton variable-speed inverter-driven R-32 heat pump condenser with the GMVC800604BN 80% AFUE two-stage gas furnace (60,000 BTU\/h input) and the CHPEA3026C3 cased horizontal evaporator coil with factory-installed electronic expansion valve (EEV) with ComfortBridge™ communicating technology. Rated at 17.5 SEER2 \/ 10.0 EER2 \/ 8.5 HSPF2, this matched system delivers 28,400 BTU\/h cooling capacity and 28,800 BTU\/h heating capacity at 47°F. The outdoor unit is ENERGY STAR® Cold Climate Certified and operates on low-GWP R-32 refrigerant (GWP: 675).\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3010\u003c\/strong\u003e — Goodman 2.5-Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser. Side-discharge cabinet with variable-speed swing compressor, digitally commutated fan motor, and EEV (Electronic Expansion Valve). Quiet-mode operation available (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA3026C3\u003c\/strong\u003e — Goodman Cased Horizontal Evaporator Coil with factory-installed electronic expansion valve (EEV). All-aluminum coil optimized for R-32 refrigerant. Cabinet dimensions: 26\" W × 21\" D × 21\" H. 21\" depth designed for easier attic access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVC800604BN\u003c\/strong\u003e — Goodman 80% AFUE Two-Stage Variable-Speed ECM Gas Furnace. 60,000 BTU\/h input capacity with two-stage gas valve that provides low-fire and high-fire operation. Upflow\/Horizontal configuration, 17½\" cabinet width. Natural Gas emissions rated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background-color: #f7f7f7; border-left: 4px solid #1a5276; padding: 15px; margin: 20px 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e🔧 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e When installing this dual fuel system with a upflow\/horizontal furnace and horizontal coil in a attic or closet application, verify the combined height of the furnace and coil assembly clears the available vertical space. The 21\" coil height stacked with the furnace can challenge tight mechanical rooms, particularly in retrofit applications where the original equipment had a smaller footprint.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e With R-32 refrigerant at 76 oz factory charge, ensure all brazed joints are nitrogen-pressurized during brazing and leak-tested to 500 PSI standing pressure for 20 minutes minimum. R-32 operates at slightly higher pressures than R-410A, and micro-leaks at field connections are the leading cause of nuisance low-charge lockouts within the first 12 months of operation. Pull the system vacuum to 300 microns or below and verify it holds under 500 microns for 15 minutes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a calibrated digital micron gauge (not a compound gauge) to verify vacuum levels. A digital manifold with R-32 PT tables ensures accurate superheat\/subcooling verification at commissioning. The GZV6S outdoor unit targets 76 oz factory charge for 15 ft of ⅜\" liquid line — adjust charge per the installation instructions for longer line sets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e All R-32 installations require EPA Section 608 certification. Verify local mechanical codes for furnace clearance-to-combustibles, particularly in upflow\/horizontal configurations where the heat exchanger proximity to flooring materials must meet NFPA 90B standards. Confirm the condensate drain meets local plumbing code requirements for both the evaporator coil and the furnace secondary heat exchanger.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e System automatically switches between electric heat pump operation and gas furnace heating based on outdoor temperature, optimizing energy costs across all climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Ratings:\u003c\/strong\u003e 17.5 SEER2 cooling and 8.5 HSPF2 heating efficiency with 80% AFUE gas furnace backup delivers year-round energy savings compared to standard single-fuel systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Operation:\u003c\/strong\u003e The inverter-driven compressor adjusts capacity continuously to match actual load conditions, reducing temperature swings and improving humidity control during partial-load operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP Refrigerant:\u003c\/strong\u003e R-32 refrigerant (GWP: 675) reduces environmental impact by approximately 68% compared to R-410A (GWP: 2,088) while delivering comparable or improved heat transfer efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Performance:\u003c\/strong\u003e Outdoor unit operates at 67 dBA in cooling and 70 dBA in heating under normal mode, with Quiet Mode reducing sound levels as low as 45 dBA for noise-sensitive installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Furnace Heating:\u003c\/strong\u003e The two-stage gas valve provides low-fire operation for mild conditions and high-fire for peak demand, improving comfort and reducing fuel consumption.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #1a5276; color: #ffffff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215488204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel (Heat Pump + Gas Furnace), Communicating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e2.5 Ton (28,400 BTU\/h Cooling)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e17.5 \/ 10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 47°F\u003c\/td\u003e\n\u003ctd\u003e28,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd\u003e17,300 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e60,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32 (Factory Charge: 76 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background-color: #eee; font-weight: bold;\"\u003eOutdoor Unit — GZV6SA3010\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e36⅝\" × 13¾\" × 27⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight \/ Shipping\u003c\/td\u003e\n\u003ctd\u003e132 lbs \/ 147 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling \/ Heating)\u003c\/td\u003e\n\u003ctd\u003e67 dBA \/ 70 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Ph \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ ⅞\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background-color: #eee; font-weight: bold;\"\u003eEvaporator Coil — CHPEA3026C3\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eCased Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e26\" × 21\" × 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Material\u003c\/td\u003e\n\u003ctd\u003eAll-Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background-color: #eee; font-weight: bold;\"\u003eGas Furnace — GMVC800604BN\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e17½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #1a5276; color: #ffffff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. 2,088 for R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215488204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR® Certified\u003c\/td\u003e\n\u003ctd\u003eENERGY STAR® Cold Climate Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 minimum efficiency standards nationwide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions (Furnace)\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eThis system may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA) — consult a qualified tax advisor for eligibility based on your specific installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA3010) — Heat Pump Warranty:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUnregistered: 5-Year Parts Limited Warranty.\u003c\/li\u003e\n\u003cli\u003eRegistered (within 60 days of installation at www.goodmanmfg.com): 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty (compressor failure — one-time replacement of entire outdoor unit).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA3026C3) — Indoor Coil Warranty:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUnregistered: 5-Year Parts Limited Warranty.\u003c\/li\u003e\n\u003cli\u003eRegistered (within 60 days of installation at www.goodmanmfg.com): 10-Year Parts Limited Warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVC800604BN) — Furnace Warranty:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUnregistered: 20-Year Heat Exchanger Limited Warranty and 5-Year Parts Limited Warranty.\u003c\/li\u003e\n\u003cli\u003eRegistered (within 60 days of installation at www.goodmanmfg.com): Lifetime Heat Exchanger Limited Warranty (up to 99 years, one replacement after year 20), 10-Year Parts Limited Warranty, and 10-Year Unit Replacement Limited Warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties apply to original owner-occupied residential installations only. Online registration must be completed within 60 days of installation. Registration not required in California, Florida, or Québec. Warranty duration may differ in Texas and Florida. Refer to complete warranty documents for full terms, limitations, and exclusions.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51882487185728,"sku":"GZV6SA3010-CHPEA3026C3-GMVC800604BN-215488204","price":5616.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/GHCYUKCJHVKJtitled.jpg?v=1777345299","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa3010-chpea3026c3-gmvc800604bn-dual-fuel-215488204","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}