{"product_id":"goodman-gzv6sa3610-ahve36cp1300-215429193","title":"Goodman 3 Ton 16.6 SEER2 R-32 Central Heat Pump Split System | GZV6SA3610 + AHVE36CP1300 | 21\" Cabinet Width, Multi-Positional Air Handler","description":"\u003cp\u003eThis Goodman 3-Ton Central Heat Pump Split System combines the GZV6SA3610* variable-speed heat pump condenser with the AHVE36CP1300 variable-speed air handler. AHRI-certified (Certificate #215429193) at 16.6 SEER2 and 8.5 HSPF2, this matched system uses R-32 low-GWP refrigerant and provides both heating and cooling from a single all-electric platform. The air handler features an integrated EEV and communicating variable-speed ECM blower for precise airflow and humidity management.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump Condenser:\u003c\/strong\u003e Goodman GZV6SA3610* — 3-Ton variable-speed inverter-driven R-32 heat pump with swing compressor, EEV metering, and digitally commutated condenser fan motor. Sound power as low as 45 dBA in quiet mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Handler:\u003c\/strong\u003e Goodman AHVE36CP1300A* — 3-Ton Multi-Positional variable-speed ECM air handler (208\/230V) with integrated EEV, all-aluminum evaporator coil, factory-installed R-32 sensor, and SmartFrame cabinet with less than 2% air leakage. 21\" depth for attic access compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The AHVE air handler's 21\" cabinet depth enables attic installations, but the 53-7\/16\" overall height requires careful verification of available vertical clearance, especially under low-pitch rafters. The coil mounting track allows repositioning, but suction and liquid line routing must accommodate the final coil orientation without kinking.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After positioning the air handler, install the condensate drain trap before running the system. The thermoplastic drain pan includes secondary drain connections — always pipe the secondary to a visible location (like over a window) as an overflow indicator. This single step prevents 90% of water-damage callbacks within the first year.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use the CoolCloud app during commissioning to verify the communicating link between the outdoor unit and air handler. Confirm the EEV superheat is auto-controlled and the subcooling at the outdoor service valve reads 15 +\/- 1 deg.F using a digital manifold gauge.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e Verify the return air duct connections meet the ASHRAE 193 cabinet air leakage standard (less than 2% at 1.0\" w.c.). Apply UL-listed mastic sealant at all duct-to-cabinet joints. In jurisdictions requiring Manual J load calculations, confirm the selected tonnage matches the calculated cooling load to avoid oversizing, which degrades dehumidification performance.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Electric Operation:\u003c\/strong\u003e No combustion, no flue venting, and no gas line required — this all-electric heat pump system simplifies installation and eliminates carbon monoxide risk in the conditioned space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Seasonal Efficiency:\u003c\/strong\u003e 16.6 SEER2 cooling and 8.5 HSPF2 heating ratings deliver substantial energy savings over standard-efficiency equipment, potentially qualifying for federal tax credits under the Inflation Reduction Act.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The outdoor inverter compressor and indoor ECM blower motor modulate to match the actual load, reducing temperature swings, improving humidity removal, and lowering sound levels during part-load operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a 68% lower global warming potential than R-410A and provides higher volumetric cooling capacity, supporting compliance with the AIM Act refrigerant phasedown schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated EEV Metering:\u003c\/strong\u003e The factory-installed electronic expansion valve in the air handler provides precise refrigerant flow control across all operating conditions, eliminating the need for field-installed metering devices and piston kits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The outdoor unit operates as low as 45 dBA in quiet mode, and the variable-speed air handler reduces blower noise at part-load by running at lower speeds.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance (AHRI Certificate #215429193)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA3610*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @17°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 71 dBA (as low as 45 dBA in quiet mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e36-5\/8\" x 13-3\/4\" x 27-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e137 lbs \/ 151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e83 oz (factory charge for 15' line set)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eAir Handler — AHVE36CP1300A*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3-Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 53-7\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e3\/4 HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e6.5A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e140 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane) — A2L (mildly flammable) classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eEPA-certified technician required for refrigerant handling; R-32 requires A2L-rated recovery equipment and leak detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll-region sales designation (Region A); verify local A2L refrigerant installation codes and charge density limits per ASHRAE 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eHeat pump systems meeting efficiency thresholds may qualify for federal tax credits under the Inflation Reduction Act (25C) — consult a qualified tax professional for current eligibility requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAHRI Certified; ETL Listed; ENERGY STAR (when matched with qualifying indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Goodman will furnish a new replacement outdoor unit (one time). Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Handler (AHVE36CP1300A*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties apply to owner-occupied residential installations only. Different terms apply to commercial and rental properties. Labor, refrigerant, freight, and other service costs are not covered. Complete warranty details are available at goodmanmfg.com.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884451496256,"sku":"GZV6SA3610-AHVE36CP1300-215429193","price":5452.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/jtyjyjtyjytled.jpg?v=1777777375","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa3610-ahve36cp1300-215429193","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}