{"product_id":"goodman-gzv6sa3610-capea3626b3-mbvk12bp1x00-215447183","title":"Goodman 3 Ton 16.6 SEER2 R-32 Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower | GZV6SA3610 + CAPEA3626B3 + MBVK12BP1X00 | 21\" Depth, Upflow\/Downflow Coil","description":"\u003cp\u003eThis Goodman 3-Ton Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower pairs the GZV6SA3610* variable-speed heat pump with the CAPEA3626B3 evaporator coil and MBVK12BP1X00 communicating modular blower. AHRI-certified (Certificate #215447183) at 16.6 SEER2 and 8.5 HSPF2, this configuration uses R-32 low-GWP refrigerant and provides efficient all-electric heating and cooling. The modular blower and coil design offers flexible installation options in both vertical and horizontal orientations.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump Condenser:\u003c\/strong\u003e Goodman GZV6SA3610* — 3-Ton variable-speed inverter-driven R-32 heat pump with swing compressor, EEV metering, and digitally commutated condenser fan motor. Sound power as low as 45 dBA in quiet mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil:\u003c\/strong\u003e Goodman CAPEA3626B3A* — 3-Ton cased Upflow\/Downflow all-aluminum evaporator coil with integrated EEV, factory-installed R-32 sensor, and thermoplastic drain pan with secondary drain connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower:\u003c\/strong\u003e Goodman MBVK12BP1X00AA — 1200-CFM variable-speed ECM communicating modular blower (17-1\/2\") with SmartFrame cabinet, integrated ComfortBridge technology, and built-in dehumidification feature. Compatible with R-32 refrigerant with integration kit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The two-piece coil-and-blower configuration offers installation flexibility, but the coil width must match the blower cabinet width for a proper seal. Mismatched widths create air bypass around the coil face, reducing system capacity and triggering low-superheat fault codes from the outdoor unit's EEV controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After mounting the coil on the blower, verify the drain pan rail alignment and apply foil-faced tape at the coil-to-blower junction seam. Pressure-test the completed assembly with a duct leakage tester — total air leakage should remain below 2% at 1.0\" w.c. per ASHRAE 193. This prevents efficiency loss and condensation issues that often surface 6-8 months after installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Verify the communicating connection between the MBVK blower, the evaporator coil's EEV, and the outdoor unit through the CoolCloud app. Confirm the blower is configured for the correct tonnage setting and that the EEV superheat is auto-controlled, with subcooling reading 15 +\/- 1 deg.F at the outdoor unit's service valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e The R-32 integration kit must be installed on the blower for R-32 compatibility. Verify the R-32 leak sensor on the coil is functional before sealing the access panel. In jurisdictions enforcing ASHRAE 15 or state-level A2L refrigerant handling requirements, ensure the installation meets maximum charge density limits for the occupied space.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Installation Flexibility:\u003c\/strong\u003e The separate coil and blower design allows each component to be positioned independently, accommodating tight mechanical closets, attics, and crawl spaces where a single-piece air handler may not fit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Seasonal Efficiency:\u003c\/strong\u003e 16.6 SEER2 cooling and 8.5 HSPF2 heating ratings maximize energy savings across both seasons, potentially qualifying for federal tax credits and utility rebates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The variable-speed outdoor compressor and communicating ECM blower motor work together to modulate airflow and capacity, delivering consistent temperatures and improved dehumidification at part-load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a 68% lower global warming potential than R-410A and offers higher volumetric cooling capacity, supporting the industry transition under the AIM Act phasedown schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating Integration:\u003c\/strong\u003e The MBVK blower's ComfortBridge technology communicates directly with the outdoor unit and compatible thermostat, enabling automated airflow configuration, tonnage matching, and diagnostic reporting through the CoolCloud app.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance (AHRI Certificate #215447183)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA3610*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @47°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e34,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @17°F (BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 71 dBA (as low as 45 dBA in quiet mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e36-5\/8\" x 13-3\/4\" x 27-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e137 lbs \/ 151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e22.4A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e83 oz (factory charge for 15' line set)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CAPEA3626B3A*\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e17-1\/2\" x 21\" x 26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connections (Liquid \/ Suction)\u003c\/td\u003e\n\u003ctd\u003e5\/16\" or 3\/8\" \/ 3\/4\" or 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e54 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\u003cth colspan=\"2\"\u003eModular Blower — MBVK12BP1X00AA\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional (Vertical \/ Horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003eUp to 1200 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e17-1\/2\" x 21\" x 26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP Variable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e4.9A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e67 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f0f0f0;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane) — A2L (mildly flammable) classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eEPA-certified technician required for refrigerant handling; R-32 requires A2L-rated recovery equipment and leak detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll-region sales designation (Region A); verify local A2L refrigerant installation codes and charge density limits per ASHRAE 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eHeat pump systems meeting efficiency thresholds may qualify for federal tax credits under the Inflation Reduction Act (25C) — consult a qualified tax professional for current eligibility requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAHRI Certified; ETL Listed; ENERGY STAR (when matched with qualifying indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Goodman will furnish a new replacement outdoor unit (one time). Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3626B3A*):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Blower (MBVK12BP1X00AA):\u003c\/strong\u003e 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAll warranties apply to owner-occupied residential installations only. Different terms apply to commercial and rental properties. Labor, refrigerant, freight, and other service costs are not covered. Complete warranty details are available at goodmanmfg.com.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884451725632,"sku":"GZV6SA3610-CAPEA3626B3-MBVK12BP1X00-215447183","price":5157.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/btnfthgytjtyjtyjed.jpg?v=1777798322","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa3610-capea3626b3-mbvk12bp1x00-215447183","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}