{"product_id":"goodman-gzv6sa3610-chpea3626c3-grvt800805cx","title":"Goodman | 3 Ton | 16.6 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CHPEA3626C3 + GRVT800805CX | 26\" Cabinet Width | Horizontal | Coil | 80,000 BTU\/h | Downflow | Two-Stage | Variable-Speed ECM | Low NOx | Furnace","description":"\u003cp\u003eThis Goodman 3-Ton 16.6 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a horizontal evaporator coil (CHPEA3626C3) and a 80,000 BTU\/h 80% AFUE downflow gas furnace (GRVT800805CX). The system is AHRI certified (Certificate #215447199) and delivers up to 33,600 BTU\/h in cooling and 34,600 BTU\/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.\u003c\/p\u003e\n\u003cp\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA3610*\u003c\/strong\u003e — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V\/1Ph\/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA3626C3\u003c\/strong\u003e — Goodman Horizontal Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 26\" W x 21\" D x 21\" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT800805CX\u003c\/strong\u003e — Goodman Downflow Two-Stage Variable-Speed ECM gas furnace. 80,000 BTU\/h input, 80% AFUE. 21\" cabinet width, Low NOx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a73e8;padding:16px;margin:16px 0;border-radius:4px;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#1a73e8;\"\u003e🛠 Pro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz\/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Heating \u0026amp; Cooling:\u003c\/strong\u003e Rated at 16.6 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e33,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e34,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (17°F)\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003eSee manufacturer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight (Shipping)\u003c\/td\u003e\n\u003ctd\u003e151 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Dimensions\u003c\/td\u003e\n\u003ctd\u003e26\" W x 21\" D x 21\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device (Coil)\u003c\/td\u003e\n\u003ctd\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Rating\u003c\/td\u003e\n\u003ctd\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicating System\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Non-Communicating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic;font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#e8e8e8;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable) per ASHRAE 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets federal minimum efficiency standards for all U.S. regions. Low NOx model complies with California SCAQMD Rule 1111 (≤40 NG\/J NOx). Verify local A2L refrigerant code adoption before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA3610*):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA3626C3):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT800805CX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em;font-style:italic;\"\u003eRegistration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884448383296,"sku":"GM-GZV6SA3610-CHPEA3626C3-GRVT800805CX","price":6381.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa3610-chpea3626c3-grvt800805cx","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}