{"product_id":"goodman-gzv6sa4210-ahve48dp1300","title":"Goodman | 3.5 Ton | 17.0 SEER2 | R-32 | Central Heat Pump Split System | GZV6SA4210 + AHVE48DP1300 | 24-1\/2\" Cabinet Width | Multi-Position | Air Handler","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eSystem Overview\u003c\/h2\u003e\n\u003cp\u003eThis Goodman 3.5 Ton Central Heat Pump Split System pairs the GZV6SA4210 high-efficiency, variable-speed, inverter-driven R-32 heat pump with the AHVE48DP1300 Multi-Position Air Handler. Rated at 17.0 SEER2 and 8.2 HSPF2, this AHRI-certified combination (Certificate #215429194) delivers all-electric heating and cooling with the air handler providing the indoor blower, evaporator coil, and EEV in a single integrated cabinet. The AHVE-series air handler features a variable-speed ECM blower motor with communicating capability, a 21\" cabinet depth for easier attic access, and all-aluminum evaporator coil construction optimized for R-32 refrigerant.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA4210\u003c\/strong\u003e — Goodman GZV6S-Series 3.5 Ton R-32 Inverter-Driven Variable-Speed Heat Pump Condenser (Side Discharge). Rated for 41,000 BTU\/h cooling at 95°F and 40,000 BTU\/h heating at 47°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHVE48DP1300\u003c\/strong\u003e — Goodman AHVE-Series Multi-Position Variable-Speed Air Handler with internal EEV, 24-1\/2\" cabinet width, 21\" depth. 208-230V\/1Ph\/60Hz electrical. Factory-installed R-32 sensor. 3\/4 HP ECM blower motor. Ships at 150 lbs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #1a73e8; padding:16px; margin:20px 0;\"\u003e\n\u003ch3 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The AHVE air handler's 21\" depth makes it a strong choice for tight attic installations, but the 53-7\/16\" overall height means you need sufficient vertical clearance above the unit for the supply plenum transition. In horizontal attic applications, verify that the truss spacing and attic height accommodate both the air handler dimensions and the required clearances to combustible materials.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e The AHVE's SmartFrame™ cabinet uses screw-less sides and back panels, which reduces condensation points in humid attic environments. However, verify that the foil-faced insulation is fully intact after positioning—even small gaps in the cabinet insulation can create condensation drip points that corrode the drain pan over time. Apply UL-listed aluminum foil tape over any insulation seams disrupted during installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e After completing refrigerant line connections, run the communicating setup procedure through the Goodman GTST connected thermostat or CoolCloud™ app. The system should auto-detect the air handler model and configure airflow tables automatically. Verify the CFM indicator on the air handler reads within ±5% of the target 1,400 CFM (400 CFM\/ton × 3.5 tons) at the design static pressure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 systems with the AHVE air handler include a factory-installed R-32 refrigerant sensor. Confirm the sensor LED indicator shows active status before closing up the equipment closet or attic access. Per UL 60335 2-40, the sensor must remain unobstructed for the life of the system. All R-32 work requires EPA Section 608 certification.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated System Design:\u003c\/strong\u003e The AHVE air handler combines evaporator coil, blower, EEV, and control board in a single matched cabinet, eliminating field-installed coil positioning, separate TXV\/piston kits, and multi-component wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e Both the outdoor compressor and indoor blower operate on variable-speed ECM motors, synchronizing airflow and refrigerant flow for optimal humidity control and consistent room temperatures across all load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Environmental Advantage:\u003c\/strong\u003e R-32 refrigerant carries a GWP of 675—approximately 68% lower than R-410A. The factory-installed R-32 sensor in the air handler provides continuous monitoring per UL 60335 2-40 safety requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAttic-Friendly Dimensions:\u003c\/strong\u003e The 21\" cabinet depth fits standard attic truss spacing, and tool-less filter access simplifies homeowner maintenance. The SmartFrame™ construction with screw-less sides minimizes condensation entry points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating Architecture:\u003c\/strong\u003e Two-wire communicating connection between outdoor unit and air handler enables automatic configuration, real-time performance monitoring, and Bluetooth-accessible diagnostics via CoolCloud™.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Outdoor unit quiet-mode reduces sound to as low as 45 dBA, while the variable-speed indoor blower ramps gradually to avoid the abrupt on\/off noise of single-speed systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215429194\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eCentral Heat Pump Split System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Capacity\u003c\/td\u003e\n\u003ctd\u003e3.5 Ton (42,000 BTU nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Pump Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e41,000 BTU\/h @ 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Pump Heating Capacity\u003c\/td\u003e\n\u003ctd\u003e40,000 BTU\/h @ 47°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Pump Heating Capacity (Low Temp)\u003c\/td\u003e\n\u003ctd\u003e27,400 BTU\/h @ 5°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight\u003c\/td\u003e\n\u003ctd\u003e185 lbs (shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Handler Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e24-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Handler Depth\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Handler Height\u003c\/td\u003e\n\u003ctd\u003e53-7\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Handler Weight\u003c\/td\u003e\n\u003ctd\u003e150 lbs (shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical (Outdoor)\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical (Air Handler)\u003c\/td\u003e\n\u003ctd\u003e208-230V\/1Ph\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP (Outdoor)\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP (Air Handler)\u003c\/td\u003e\n\u003ctd\u003e6.5A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333; color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (vs. 2,088 for R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eCertified technician required for refrigerant handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions (verify local A2L adoption status)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215429194\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify under 25C\/25D credits. Consult a tax professional and visit goodmanmfg.com\/resources\/tax-credit for current guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA4210 (Outdoor Heat Pump):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when registered online at goodmanmfg.com within 60 days of installation. 5-Year Parts Limited Warranty if not registered. One-time Compressor Replacement coverage for years 11–99 is available through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHVE48DP1300 (Air Handler):\u003c\/strong\u003e 10-Year Parts Limited Warranty when registered online at goodmanmfg.com within 60 days of installation. 5-Year Parts Limited Warranty if not registered.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRegistration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida. Refer to the manufacturer's full warranty documentation for complete terms, limitations, and exclusions.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884474106176,"sku":"GZV6SA4210-AHVE48DP1300","price":5866.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/BMitled.jpg?v=1777641264","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa4210-ahve48dp1300","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}