{"product_id":"goodman-gzv6sa4210-capea4830c3-mbvk16cp1x00","title":"Goodman | 3.5 Ton | 17.0 SEER2 | R-32 | Central Heat Pump Split System with Evaporator Coil \u0026 Modular Blower | GZV6SA4210 + CAPEA4830C3 + MBVK16CP1X00 | 21\" Cabinet Width | Upflow\/Downflow | Coil | 21\" Cabinet Width | Multi-Positional | Modular Blower","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eSystem Overview\u003c\/h2\u003e\n\u003cp\u003eThis Goodman 3.5 Ton Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower pairs the GZV6SA4210 high-efficiency, variable-speed, inverter-driven R-32 heat pump with the CAPEA4830C3 Cased Upflow\/Downflow Evaporator Coil and MBVK16CP1X00 Modular Blower. Rated at 17.0 SEER2 and 8.0 HSPF2, this AHRI-certified combination (Certificate #215447228) delivers all-electric heating and cooling. The modular blower provides the air distribution component where no furnace or integrated air handler is used, creating a complete split system with separate, field-matched coil and blower sections. This configuration is optimized for R-32 refrigerant with a GWP of 675.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA4210\u003c\/strong\u003e — Goodman GZV6S-Series 3.5 Ton R-32 Inverter-Driven Variable-Speed Heat Pump Condenser (Side Discharge). Rated for 41,000 BTU\/h cooling at 95°F and 40,000 BTU\/h heating at 47°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA4830C3\u003c\/strong\u003e — Goodman Cased Upflow\/Downflow Evaporator Coil with 21\" cabinet width, 21\" depth, and 30\" height. All-aluminum 7mm tube construction with EEV compatibility. Ships at 68 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMBVK16CP1X00\u003c\/strong\u003e — Goodman MBVK-Series Multi-Positional Modular Blower with 3\/4 HP variable-speed ECM motor. Cabinet dimensions: 21\" W x 21\" D x 30\" H. 208\/230V electrical. Ships at 80 lbs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #1a73e8; padding:16px; margin:20px 0;\"\u003e\n\u003ch3 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e Modular blower-to-coil joints require a precise seal to prevent conditioned air bypass and condensation leaks. The 21\" blower must align flush with the 21\" coil section—any mismatch in cabinet widths requires a factory filler plate kit (Goodman part FPKT01). In high-humidity environments, the coil-to-blower junction is the primary condensation failure point if not properly sealed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Apply the factory-provided gasket (part 0154D20003S) at the coil-blower joint, and verify the drain pan is properly pitched toward the primary drain connection. For horizontal installations in unconditioned attic spaces, install the optional condensate management kit (MBK0002) to address secondary condensation that forms on the blower cabinet exterior during peak cooling. This prevents water staining and mold growth on ceiling drywall below—a common callback 6–12 months post-install.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e After completing all refrigerant connections, verify system subcooling at 8±1°F with a digital manifold gauge set. Use the CoolCloud™ app or GTST thermostat to confirm the communicating bus has established connection between the outdoor unit, coil EEV, and blower motor controller. Verify airflow at the blower outlet with an anemometer or flow hood, targeting 1,400 CFM ±10% for this 3.5-ton system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 refrigerant is classified A2L (mildly flammable) under ASHRAE 34. The R-32 accessory kit (part 0230K00044) is required if the modular blower is not factory-rated for A2L refrigerants. Verify local code adoption of 2024 UMC\/IMC A2L provisions. All R-32 work requires EPA Section 608 certification.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Flexibility:\u003c\/strong\u003e The separate coil + blower configuration allows independent component replacement and sizing, providing installers more flexibility in tight mechanical rooms, closets, or horizontal attic installations where integrated air handlers may not fit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The inverter-driven outdoor compressor and ECM blower motor work together to modulate airflow and refrigerant flow for optimal humidity control, consistent temperatures, and reduced energy consumption during part-load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Environmental Advantage:\u003c\/strong\u003e R-32 refrigerant carries a GWP of 675—approximately 68% lower than R-410A—reducing the carbon footprint of the refrigeration cycle over the entire system service life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Electric Operation:\u003c\/strong\u003e No gas piping, venting, or combustion air requirements simplify permitting and installation while eliminating combustion byproducts from the conditioned space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Outdoor unit quiet-mode reduces sound to as low as 45 dBA with three selectable levels. The variable-speed indoor blower ramps gradually to minimize duct noise and pressure surges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447228\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eCentral Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Capacity\u003c\/td\u003e\n\u003ctd\u003e3.5 Ton (42,000 BTU nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Pump Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e41,000 BTU\/h @ 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Pump Heating Capacity\u003c\/td\u003e\n\u003ctd\u003e40,000 BTU\/h @ 47°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Pump Heating Capacity (Low Temp)\u003c\/td\u003e\n\u003ctd\u003e27,400 BTU\/h @ 5°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight\u003c\/td\u003e\n\u003ctd\u003e185 lbs (shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Weight\u003c\/td\u003e\n\u003ctd\u003e68 lbs (shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Weight\u003c\/td\u003e\n\u003ctd\u003e80 lbs (shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical (Outdoor)\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical (Blower)\u003c\/td\u003e\n\u003ctd\u003e208\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP (Outdoor)\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333; color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (vs. 2,088 for R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eCertified technician required for refrigerant handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions (verify local A2L adoption status)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447228\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify under 25C\/25D credits. Consult a tax professional and visit goodmanmfg.com\/resources\/tax-credit for current guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA4210 (Outdoor Heat Pump):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when registered online at goodmanmfg.com within 60 days of installation. 5-Year Parts Limited Warranty if not registered. One-time Compressor Replacement coverage for years 11–99 is available through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA4830C3 (Evaporator Coil):\u003c\/strong\u003e 10-Year Parts Limited Warranty when registered online at goodmanmfg.com within 60 days of installation. 5-Year Parts Limited Warranty if not registered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMBVK16CP1X00 (Modular Blower):\u003c\/strong\u003e 10-Year Parts Limited Warranty when registered online at goodmanmfg.com within 60 days of installation. 5-Year Parts Limited Warranty if not registered.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRegistration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida. Refer to the manufacturer's full warranty documentation for complete terms, limitations, and exclusions.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884474368320,"sku":"GZV6SA4210-CAPEA4830C3-MBVK16CP1X00","price":5625.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Untitled_a85500c2-4ff9-4614-9c22-0187ce6b0e00.jpg?v=1777630374","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa4210-capea4830c3-mbvk16cp1x00","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}