{"product_id":"goodman-gzv6sa4210-capea4830d3-gmvc800804cx","title":"Goodman | 3.5 Ton | 17.0 SEER2 | R-32 | Dual Fuel System | GZV6SA4210 + CAPEA4830D3 + GMVC800804CX | 24-1\/2\" Cabinet Width | Upflow\/Downflow | Coil | 80,000 BTU | Upflow\/Horizontal | Two-Stage | Variable-Speed ECM | Low NOx | Furnace | Communicating","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eSystem Overview\u003c\/h2\u003e\n\u003cp\u003eThis Goodman 3.5 Ton Dual Fuel System pairs the GZV6SA4210 high-efficiency, variable-speed, inverter-driven R-32 heat pump with the GMVC800804CX 80% AFUE Two-Stage Variable-Speed ECM Low NOx Gas Furnace and CAPEA4830D3 Cased Upflow\/Downflow Evaporator Coil with communicating ComfortBridge™ technology. Rated at 17.0 SEER2 \/ 8.0 HSPF2 for heat pump operation and 80% AFUE for gas heating, this AHRI-certified combination (Certificate #215488264) provides year-round comfort with automatic switchover between electric heat pump and gas furnace operation based on outdoor temperature and energy cost thresholds. The heat pump operates on environmentally responsible R-32 refrigerant (GWP of 675), significantly reducing carbon footprint compared to legacy R-410A systems.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA4210\u003c\/strong\u003e — Goodman GZV6S-Series 3.5 Ton R-32 Inverter-Driven Variable-Speed Heat Pump Condenser (Side Discharge). Rated for 41,000 BTU\/h cooling at 95°F and 40,000 BTU\/h heating at 47°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA4830D3\u003c\/strong\u003e — Goodman Cased Upflow\/Downflow Evaporator Coil with 24-1\/2\" cabinet width, 21\" depth, and 30\" height. All-aluminum 7mm tube construction with EEV compatibility. Ships at 70 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVC800804CX\u003c\/strong\u003e — Goodman 80% AFUE Two-Stage Variable-Speed ECM Low NOx Gas Furnace, 80,000 BTU\/h input \/ 64,000 BTU\/h output. Upflow\/Horizontal installation with 21\" cabinet width. Features durable stainless-steel heat exchanger, SureStart® Silicon Nitride igniter, and self-diagnostic control board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #1a73e8; padding:16px; margin:20px 0;\"\u003e\n\u003ch3 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e In a dual fuel configuration with a 21\"-wide furnace and upflow\/downflow coil, the EEV communication wiring between the GZV6SA4210 outdoor unit and the indoor coil must route through or alongside the furnace cabinet. Misrouted low-voltage wiring near the gas valve solenoid can introduce EMI noise on the communicating bus, causing intermittent fault codes (especially E7 or E8 communication errors) that only appear under heating load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Secure all low-voltage communicating wires at least 2 inches from any high-voltage or gas valve wiring inside the furnace cabinet, using adhesive-backed cable clips rated for plenum spaces. After commissioning, run the system through a full heating-to-cooling switchover cycle while monitoring the CoolCloud™ app for communication stability. This 10-minute validation prevents nuisance service calls 6-12 months post-install when temperature extremes trigger frequent mode changes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use the CoolCloud™ phone application to verify the communicating bus is reading all indoor and outdoor sensor values without dropouts. Confirm subcooling of 8±1°F at the outdoor unit service valve with a calibrated digital manifold gauge set (e.g., Testo 557s or Fieldpiece SMAN4).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 refrigerant is classified as A2L (mildly flammable) under ASHRAE 34. All joints must be leak-tested per EPA Section 608 requirements using an electronic leak detector rated for A2L refrigerants. Verify local jurisdiction has adopted the 2024 UMC\/IMC codes that include A2L provisions before proceeding with installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Automatic switchover between 17.0 SEER2 heat pump operation and 80% AFUE gas heating delivers the lowest operating cost across all climate conditions, selecting whichever fuel source is most economical at any given outdoor temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The inverter-driven compressor modulates capacity from approximately 40% to 100% (and boost mode beyond rated capacity), maintaining tighter temperature control (±0.5°F) while reducing compressor cycling, duct noise, and humidity fluctuations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Environmental Advantage:\u003c\/strong\u003e R-32 refrigerant carries a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). Combined with the higher system efficiency, total equivalent warming impact is substantially reduced over the system's service life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEEV Precision Metering:\u003c\/strong\u003e The Electronic Expansion Valve adjusts superheat in real time based on load conditions, replacing traditional fixed-orifice or TXV metering with fully variable refrigerant flow control for improved seasonal performance and dehumidification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Quiet-mode capability reduces outdoor unit sound levels to as low as 45 dBA through variable fan speed and compressor speed management—equivalent to a quiet residential conversation. Three selectable sound levels accommodate noise-sensitive installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuture-Ready Platform:\u003c\/strong\u003e Communicating architecture supports two-wire connection between indoor and outdoor equipment, simplifying wiring while enabling advanced diagnostics, automatic setup, and firmware-upgradable control logic via CoolCloud™ Bluetooth diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215488264\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel (Heat Pump + Gas Furnace + Evaporator Coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Capacity\u003c\/td\u003e\n\u003ctd\u003e3.5 Ton (42,000 BTU nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Pump Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e41,000 BTU\/h @ 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Pump Heating Capacity\u003c\/td\u003e\n\u003ctd\u003e40,000 BTU\/h @ 47°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Pump Heating Capacity (Low Temp)\u003c\/td\u003e\n\u003ctd\u003e27,400 BTU\/h @ 5°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Output\u003c\/td\u003e\n\u003ctd\u003e64,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight\u003c\/td\u003e\n\u003ctd\u003e185 lbs (shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e24-1\/2\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Weight\u003c\/td\u003e\n\u003ctd\u003e70 lbs (shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Cabinet Width\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical (Outdoor)\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP (Outdoor)\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333; color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (vs. 2,088 for R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eCertified technician required for refrigerant handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions (verify local A2L adoption status)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215488264\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting applicable efficiency thresholds may qualify under 25C\/25D credits. Consult a tax professional and visit goodmanmfg.com\/resources\/tax-credit for current guidance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA4210 (Outdoor Heat Pump):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when registered online at goodmanmfg.com within 60 days of installation. 5-Year Parts Limited Warranty if not registered. One-time Compressor Replacement coverage for years 11–99 is available through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVC800804CX (Gas Furnace):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty, 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when registered online at goodmanmfg.com within 60 days of installation. 5-Year Parts Limited Warranty if not registered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA4830D3 (Evaporator Coil):\u003c\/strong\u003e 10-Year Parts Limited Warranty when registered online at goodmanmfg.com within 60 days of installation. 5-Year Parts Limited Warranty if not registered.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRegistration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida. Refer to the manufacturer's full warranty documentation for complete terms, limitations, and exclusions.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884470370624,"sku":"GZV6SA4210-CAPEA4830D3-GMVC800804CX","price":6557.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Uyjtyjgyjled_4d58a104-1fbe-4730-a790-b1b8f07136f0.jpg?v=1777730060","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa4210-capea4830d3-gmvc800804cx","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}