{"product_id":"goodman-gzv6sa4810-capea4830d3-mbvk16cp1x00","title":"Goodman | 4 Ton | 17.0 SEER2 | R-32 | Central Heat Pump Split System with Evaporator Coil \u0026 Modular Blower | GZV6SA4810 | CAPEA4830D3 | MBVK16CP1X00 | 24-1\/2\" Cabinet Width | Upflow\/Downflow Coil | 21\" Cabinet Width | Multi-Positional Modular Blower","description":"\u003cdiv style=\"font-family:Arial,sans-serif;max-width:960px;margin:0 auto;\"\u003e\n\u003cp\u003eThis Goodman Central Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower pairs the GZV6SA4810 variable-speed inverter-driven heat pump with the CAPEA4830D3 evaporator coil and MBVK16CP1X00 communicating modular blower, delivering 17.0 SEER2 cooling and 8.2 HSPF2 heating efficiency. AHRI Certified under Certificate No. 215487308, this all-electric R-32 system uses a two-piece indoor assembly for flexible installation configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Side-Discharge Heat Pump Condenser (208-230\/1\/60)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA4830D3\u003c\/strong\u003e — Goodman Cased Upflow\/Downflow R-32 Evaporator Coil with Internal EEV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMBVK16CP1X00\u003c\/strong\u003e — Goodman Multi-Positional Variable-Speed ECM Communicating Modular Blower (208-230\/1\/60)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #2b579a;padding:16px 20px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#2b579a;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The two-piece indoor assembly (coil + modular blower) requires precise alignment to maintain cabinet air leakage below 2% per ASHRAE 193. Gaps between the coil and blower sections create bypass air that degrades system efficiency and can cause condensation issues in humid climates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Apply foil-faced tape at all seams between the coil section and blower cabinet. Verify drain pan slope direction matches the intended airflow orientation to prevent standing water that leads to biological growth and warranty-voiding corrosion within 12 months.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manometer to measure total external static pressure across the combined indoor assembly. The modular blower's variable-speed ECM compensates for duct resistance, but total ESP readings above 0.5\" W.C. indicate installation issues that will reduce equipment lifespan.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 (GWP 675) requires EPA Section 608 certification for handling. Verify all refrigerant connections at the coil meet manufacturer torque specifications with a calibrated torque wrench — overtightening brass flare fittings on R-32 systems is a leading cause of slow leaks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling:\u003c\/strong\u003e 17.0 SEER2 rating reduces electricity consumption compared to federal minimum 14.3 SEER2 systems, translating to measurable utility savings over the equipment lifespan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Pump Heating Efficiency:\u003c\/strong\u003e 8.2 HSPF2 rating provides efficient electric heating, with 28,000 BTU\/h capacity even at 5°F outdoor temperature for cold-climate performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Compressor:\u003c\/strong\u003e The swing compressor modulates capacity between partial and full load, maintaining tighter temperature control (±0.5°F) and reducing on\/off cycling that causes temperature swings and increased wear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (GWP 675):\u003c\/strong\u003e Lower Global Warming Potential than R-410A (GWP 2088), reducing the system's direct environmental impact by approximately 68% — consistent with EPA AIM Act and future regulatory requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Quiet-mode operation as low as 45 dBA with high-density compressor sound blanket and digitally commutated fan motor for reduced sound output — suitable for noise-sensitive installations near bedrooms or property lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR Most Efficient 2025 (Cold Climate):\u003c\/strong\u003e Recognized by the EPA as meeting the most rigorous energy efficiency performance levels, qualifying for potential utility rebates and federal tax credits under the Inflation Reduction Act (IRA).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#2b579a;color:#fff;\"\u003e\n\u003cth style=\"padding:10px;text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px;text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e215487308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eSystem Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eCentral Heat Pump Split System with Evaporator Coil \u0026amp; Modular Blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e4 Ton (48,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eSEER2\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e17.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eEER2\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutdoor Unit Max Cooling Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e45,500 BTU\/h @ 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutdoor Unit Max Heating Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e45,500 BTU\/h @ 47°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutdoor Unit Max Heating Capacity (Low Temp)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e28,000 BTU\/h @ 5°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutdoor Unit Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutdoor Unit Weight\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e168 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutdoor Unit Electrical\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e208-230\/1\/60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutdoor Unit MCA \/ MOCP\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e31.8A \/ 35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eExpansion Device\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eLiquid Line Size\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eSuction Line Size\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e1-1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eEvaporator Coil Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e24-1\/2\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eEvaporator Coil Ship Weight\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e70 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eEvaporator Coil Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eModular Blower Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eModular Blower Ship Weight\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e80 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eModular Blower Motor\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eVariable-Speed ECM (3\/4 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eModular Blower Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e208-230\/1\/60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eCoil\/Furnace Fit\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e1.75\" overhang\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"padding:8px;font-style:italic;font-size:12px;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#2b579a;color:#fff;\"\u003e\n\u003cth style=\"padding:10px;text-align:left;\"\u003eCategory\u003c\/th\u003e\n\u003cth style=\"padding:10px;text-align:left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e675 (vs. R-410A GWP 2088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eEPA 608 Certification Required\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eYes — Section 608 Universal or Type II certification required for refrigerant handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eYes — Certificate No. 215487308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eETL\/UL Listed\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eYes — ETL Listed, UL 60335-2-40 Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eENERGY STAR Certified\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eENERGY STAR Most Efficient 2025 (Cold Climate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eAll Regions (DOE 2023 minimum efficiency standards compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003ePotential eligibility under the Inflation Reduction Act (IRA) — consult a qualified tax professional for current credit amounts and income requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOutdoor Unit (GZV6SA4810):\u003c\/strong\u003e Covered under the Goodman GZV6S Limited Warranty. Unregistered: 5-Year Parts Limited Warranty. Registered (within 60 days of installation at goodmanmfg.com): 10-Year Parts Limited Warranty plus 10-Year Unit Replacement Limited Warranty for compressor failure — Daikin will furnish a new equivalent unit if the compressor fails within 10 years. Online registration is not required in California, Florida, or Québec. Warranty coverage durations in Texas and Florida may differ.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEvaporator Coil (CAPEA4830D3):\u003c\/strong\u003e Covered under the Goodman Indoor Coil Limited Warranty. Unregistered: 5-Year Parts Limited Warranty. Registered (within 60 days at goodmanmfg.com): 10-Year Parts Limited Warranty. Online registration is not required in Florida, California, or Québec.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModular Blower (MBVK16CP1X00):\u003c\/strong\u003e Covered under the Goodman MBVK Blower and Air Handler Limited Warranty. Unregistered: 5-Year Parts Limited Warranty. Registered (within 60 days at goodmanmfg.com): 10-Year Parts Limited Warranty. Online registration is not required in Florida, California, or Québec.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884509167936,"sku":"GZV6SA4810-CAPEA4830D3-MBVK16CP1X00","price":5942.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Untitled_a85500c2-4ff9-4614-9c22-0187ce6b0e00.jpg?v=1777630374","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa4810-capea4830d3-mbvk16cp1x00","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}