{"product_id":"goodman-gzv6sa4810-capea6030c3-gcvm971005cn-ahri-215487361","title":"Goodman | 4 Ton | 16.2 SEER2 | R-32 | Dual Fuel System | GZV6SA4810 | CAPEA6030C3 | GCVM971005CN | 21\" Cabinet Width | Upflow\/Downflow Coil | 100,000 BTU\/h | Downflow\/Horizontal | Modulating | Variable-Speed ECM | Furnace | Communicating","description":"\u003cdiv style=\"font-family:Arial,sans-serif;max-width:960px;margin:0 auto;\"\u003e\n\u003cp\u003eThis Goodman Dual Fuel System combines the GZV6SA4810 variable-speed inverter-driven heat pump condenser with the GCVM971005CN gas furnace and CAPEA6030C3 evaporator coil, delivering 16.2 SEER2 efficiency when cooling and 97.0% AFUE gas heating performance. AHRI Certified under Certificate No. 215487361, this matched R-32 system provides year-round comfort through automatic heat source switching — the heat pump handles moderate temperatures while the gas furnace takes over during extreme cold for maximum economy.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Side-Discharge Heat Pump Condenser (208-230\/1\/60)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030C3\u003c\/strong\u003e — Goodman Cased Upflow\/Downflow R-32 Evaporator Coil with Internal EEV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCVM971005CN\u003c\/strong\u003e — Goodman 100,000 BTU\/h 97% AFUE Modulating Variable-Speed ECM Downflow\/Horizontal Gas Furnace\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #2b579a;padding:16px 20px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#2b579a;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e R-32 systems operating in dual fuel mode require precise changeover point calibration. The GZV6SA4810's EEV and variable-speed compressor demand verified subcooling at the service valve (9±1°F per manufacturer spec) — rushing this step with non-communicating thermostats can cause short-cycling at the switchover temperature.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e After commissioning, run both heating modes through a full cycle and verify the fossil fuel kit (AFE18-60A) changeover relay timing. Confirm the defrost board lockout settings match the furnace two-stage timing to prevent nuisance fault codes 6-12 months into the first heating season.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge set with R-32 pressure tables and verify superheat\/subcooling with a thermocouple-equipped meter. The EEV auto-controls superheat, but subcooling at the liquid service valve must be manually verified during the final charge procedure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 (GWP 675) requires EPA Section 608 certification for handling. Verify local code compliance for the furnace venting configuration — 80% AFUE units require Category I venting while 96-97% AFUE condensing furnaces require Category IV PVC venting per the latest edition of NFPA 54\/ANSI Z223.1.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling:\u003c\/strong\u003e 16.2 SEER2 rating reduces electricity consumption compared to federal minimum 14.3 SEER2 systems, translating to measurable utility savings over the equipment lifespan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatically switches between heat pump (electric) and gas furnace (97% AFUE) based on outdoor temperature, optimizing fuel costs across all climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Compressor:\u003c\/strong\u003e The swing compressor modulates capacity between partial and full load, maintaining tighter temperature control (±0.5°F) and reducing on\/off cycling that causes temperature swings and increased wear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (GWP 675):\u003c\/strong\u003e Lower Global Warming Potential than R-410A (GWP 2088), reducing the system's direct environmental impact by approximately 68% — consistent with EPA AIM Act and future regulatory requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Quiet-mode operation as low as 45 dBA with high-density compressor sound blanket and digitally commutated fan motor for reduced sound output — suitable for noise-sensitive installations near bedrooms or property lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR Most Efficient 2025 (Cold Climate):\u003c\/strong\u003e Recognized by the EPA as meeting the most rigorous energy efficiency performance levels, qualifying for potential utility rebates and federal tax credits under the Inflation Reduction Act (IRA).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#2b579a;color:#fff;\"\u003e\n\u003cth style=\"padding:10px;text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px;text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e215487361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eSystem Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e4 Ton (48,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eSEER2\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e16.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eEER2\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e8.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e8.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eAFUE\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e97.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutdoor Unit Max Cooling Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e45,500 BTU\/h @ 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutdoor Unit Max Heating Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e45,500 BTU\/h @ 47°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutdoor Unit Max Heating Capacity (Low Temp)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e28,000 BTU\/h @ 5°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutdoor Unit Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutdoor Unit Weight\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e168 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutdoor Unit Electrical\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e208-230\/1\/60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutdoor Unit MCA \/ MOCP\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e31.8A \/ 35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eExpansion Device\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eLiquid Line Size\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eSuction Line Size\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e1-1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eEvaporator Coil Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e21\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eEvaporator Coil Ship Weight\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eEvaporator Coil Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eUpflow\/Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eFurnace Heating Output\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e97,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eGas Valve Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eFurnace Motor\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eFurnace Vent Diameter\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eFurnace Ship Weight\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e146 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eCoil\/Furnace Fit\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eFlush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\" style=\"padding:8px;font-style:italic;font-size:12px;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#2b579a;color:#fff;\"\u003e\n\u003cth style=\"padding:10px;text-align:left;\"\u003eCategory\u003c\/th\u003e\n\u003cth style=\"padding:10px;text-align:left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e675 (vs. R-410A GWP 2088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eEPA 608 Certification Required\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eYes — Section 608 Universal or Type II certification required for refrigerant handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eYes — Certificate No. 215487361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eETL\/UL Listed\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eYes — ETL Listed, UL 60335-2-40 Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eENERGY STAR Certified\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eENERGY STAR Most Efficient 2025 (Cold Climate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eAll Regions (DOE 2023 minimum efficiency standards compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eNOx Emissions (Furnace)\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eStandard Natural Gas — verify local NOx requirements before installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003ePotential eligibility under the Inflation Reduction Act (IRA) — consult a qualified tax professional for current credit amounts and income requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eFlorida Building Code\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eOutdoor unit meets 2023 Florida Building Code unit integrity requirements for hurricane-type winds when properly anchored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOutdoor Unit (GZV6SA4810):\u003c\/strong\u003e Covered under the Goodman GZV6S Limited Warranty. Unregistered: 5-Year Parts Limited Warranty. Registered (within 60 days of installation at goodmanmfg.com): 10-Year Parts Limited Warranty plus 10-Year Unit Replacement Limited Warranty for compressor failure — Daikin will furnish a new equivalent unit if the compressor fails within 10 years. Online registration is not required in California, Florida, or Québec. Warranty coverage durations in Texas and Florida may differ.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEvaporator Coil (CAPEA6030C3):\u003c\/strong\u003e Covered under the Goodman Indoor Coil Limited Warranty. Unregistered: 5-Year Parts Limited Warranty. Registered (within 60 days at goodmanmfg.com): 10-Year Parts Limited Warranty. Online registration is not required in Florida, California, or Québec.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGas Furnace (GCVM971005CN):\u003c\/strong\u003e Covered under the Goodman Furnace Limited Warranty. Unregistered: 20-Year Heat Exchanger Limited Warranty plus 5-Year Parts Limited Warranty. Registered (within 60 days at goodmanmfg.com): Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty. Online registration is not required in Florida, California, or Québec.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884507267392,"sku":"GZV6SA4810-CAPEA6030C3-GCVM971005CN-AHRI-215487361","price":8256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/uutbtbbtbtbtubled.jpg?v=1777727051","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa4810-capea6030c3-gcvm971005cn-ahri-215487361","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}