{"product_id":"goodman-gzv6sa6010-ahve60dp0300","title":"Goodman 5 Ton 16.6 SEER2 R-32 Central Heat Pump Split System | GZV6SA6010 | AHVE60DP0300 | 24½\" Cabinet Width | Multi-Positional | Air Handler","description":"\u003ch2\u003eGoodman 5 Ton 16.6 SEER2 Central Heat Pump Split System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified central heat pump split system (Certificate #215429797) combines the Goodman GZV6SA6010 variable-speed heat pump condenser with the AHVE60DP0300 multi-positional air handler. Using next-generation R-32 refrigerant (GWP 675), this matched system achieves up to 16.6 SEER2 and 8.2 HSPF2 ratings. The outdoor unit provides up to 53,500 BTU\/h in cooling and 54,500 BTU\/h in heat pump heating at 47°F. The variable-speed compressor and VS-ECM air handler motor work together for enhanced humidity control, quieter operation, and consistent comfort across all load conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — Goodman 5 Ton Variable-Speed Side Discharge Heat Pump Condenser (R-32, EEV, 37\" W x 12⅝\" D x 39\" H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHVE60DP0300\u003c\/strong\u003e — Goodman 5 Ton Multi-Positional Variable-Speed Air Handler (24½\" Cabinet Width, 115V \/ 1 Phase \/ 60 Hz)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Air handler installations in tight attic or closet spaces require careful attention to return air clearances. At 58 inches tall, the AHVE60 demands vertical space planning — especially in horizontal configurations where condensate drain routing and filter access become the most common callback triggers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e Install the condensate drain with a proper trap and secondary drain or float switch per local code. A clogged primary drain on a 5-ton system can produce significant water damage in minutes. Pre-install a condensate management accessory kit and slope the primary drain at minimum ¼\" per foot to prevent standing water and biological growth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e After evacuation, verify the system holds below 500 microns for a minimum of 15 minutes using a digital micron gauge — not a compound gauge. With 118 oz of R-32 factory charge plus any field additions for line set length, accurate measurement prevents overcharging that degrades EEV performance and compressor longevity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 systems require copper linesets rated for higher working pressures (minimum 700 PSI burst). Verify all flare connections with a calibrated torque wrench to manufacturer specifications — over-torquing R-32 flares is the leading cause of slow leaks. Confirm local jurisdiction has adopted A2L refrigerant provisions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Cooling \u0026amp; Heating:\u003c\/strong\u003e Up to 16.6 SEER2 \/ 9.0 EER2 \/ 8.2 HSPF2 ratings verified through AHRI certification (#215429797), delivering dependable seasonal performance across varying climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNext-Generation R-32 Refrigerant:\u003c\/strong\u003e R-32 has a GWP of 675, approximately 68% lower than R-410A (GWP 2,088). This translates to reduced environmental impact while maintaining comparable thermodynamic efficiency, and positions the system for long-term regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The GZV6SA6010 uses a variable-speed swing compressor that modulates capacity to match real-time load demands. This reduces energy consumption during part-load conditions, minimizes temperature swings, and improves whole-house humidity control compared to single-speed or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Three-level quiet mode allows sound suppression down to 45 dBA sound pressure at 3 feet. The digitally commutated fan motor and high-density compressor sound blanket further reduce operational noise — a measurable improvement for installations near bedrooms, patios, and property lines subject to local noise ordinances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Electric Heating \u0026amp; Cooling:\u003c\/strong\u003e Eliminates the need for gas infrastructure, simplifying installation and reducing carbon emissions. The variable-speed compressor provides effective heating down to -10°F ambient, covering most residential heating loads without supplemental heat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVS-ECM Air Handler Motor:\u003c\/strong\u003e The variable-speed electronically commutated motor in the air handler adjusts airflow to match system demand, reducing electrical consumption by up to 75% compared to standard PSC motors while maintaining consistent comfort.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215429797\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eCentral Heat Pump Split System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2 Rating\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Rating\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h at 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA6010\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#f2f2f2;\"\u003e\u003cstrong\u003eAir Handler — AHVE60DP0300\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e58\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e1 HP VS-ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e167 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A at 2,088)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Requirements\u003c\/td\u003e\n\u003ctd\u003eCertified technicians required for refrigerant handling; venting prohibition applies per Clean Air Act\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions — meets DOE 2023 minimum efficiency standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #{ahri})\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Cold Climate\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility (25C)\u003c\/td\u003e\n\u003ctd\u003eThis system may qualify for a federal tax credit under IRC Section 25C for energy-efficient home improvements. Consult a qualified tax professional to verify eligibility and current credit amounts based on the installed configuration and applicable tax year requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA6010):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With online registration at goodmanmfg.com within 60 days of installation, coverage extends to 10-Year Registered Additional Term Limited Warranty on all parts. Coverage applies to owner-occupied residential installations only. Registration requirements may not apply in Florida, California, or Québec. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Handler (AHVE60DP0300):\u003c\/strong\u003e 5-Year Initial Term Limited Warranty on all parts. With registration within 60 days at goodmanmfg.com, extends to 10-Year Registered Additional Term Limited Warranty on all parts. Owner-occupied residential installations only. Labor, refrigerant, and freight are not covered.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884538954048,"sku":"GZV6SA6010-AHVE60DP0300","price":6874.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/BMitled.jpg?v=1777641264","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa6010-ahve60dp0300","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}