{"product_id":"goodman-gzv6sa6010-chpea4830d3-gdvt961205dn-ahri-215447281","title":"Goodman 5 Ton 16.0 SEER2 R-32 Dual Fuel System | GZV6SA6010 Heat Pump + CHPEA4830D3 24-1\/2\" Cabinet Height Horizontal Coil + GDVT961205DN 120,000 BTU Downflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 5 Ton 16.0 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447281) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GDVT961205DN 120,000 BTU\/h 96% AFUE gas furnace and the CHPEA4830D3 cased horizontal evaporator coil. Rated at 16.0 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V\/1Ph\/60Hz electrical. Dimensions: 37\" W x 12-5\/8\" D x 39\" H. Equipment Weight: 168 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830D3\u003c\/strong\u003e — 4-Ton R-32 Cased Horizontal Cased Evaporator Coil with EEV expansion device. Horizontal configuration. Cabinet Dimensions: 30\" W x 21\" D x 24-1\/2\" H. Ship Weight: 78 lbs. Aluminum coil construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT961205DN\u003c\/strong\u003e — 120,000 BTU\/h Input (115,320 BTU\/h Output) 96% AFUE Two-Stage Natural Gas Gas Furnace. Variable-Speed ECM circulator blower motor. Downflow\/Horizontal configuration. Cabinet Dimensions: 24-1\/2\" W x 28-7\/8\" D x 34-1\/2\" H. Direct Vent (Category IV) venting (2\"-3\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #c62828;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#c62828;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e The downflow\/horizontal furnace configuration with a horizontal coil requires precise ductwork transitions. The 24-1\/2\" furnace cabinet mated to the 30\" wide CHPEA4830D3 horizontal coil may require adapter plates or field-fabricated transitions, especially in crawlspace or attic installations where access is limited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e In dual fuel mode, the system alternates between heat pump heating and gas furnace heating based on outdoor temperature. Verify the outdoor ambient temperature sensor is positioned away from direct sunlight, exhaust vents, and radiant heat sources. A sensor reading 5°F too high will cause premature gas furnace engagement, negating heat pump efficiency savings at moderate temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e After brazing the R-32 refrigerant connections, pressure test with dry nitrogen to 600 PSI and hold for 15 minutes. R-32 operates at slightly higher pressures than R-410A, making leak-tight connections critical. Document the standing pressure test result and evacuation micron reading on your commissioning checklist.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e This system uses R-32 (A2L, GWP 675), requiring compliance with ASHRAE 15 charge limits and local mechanical code provisions for mildly flammable refrigerants. EPA Section 608 certification is mandatory for handling R-32. Some jurisdictions may require additional training or certification specific to A2L refrigerants.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Combines 16.0 SEER2 \/ 8.2 HSPF2 heat pump performance with 96% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Airflow Management:\u003c\/strong\u003e The Variable-Speed ECM blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot\/cold spots and lowering operating noise compared to PSC motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Gas Valve:\u003c\/strong\u003e Two-stage gas valve operates at 70% capacity on low fire for most heating demand, reducing temperature swings and gas consumption while reserving full output for the coldest conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified Match:\u003c\/strong\u003e All components are AHRI-certified as a matched system (Certificate #215447281), ensuring rated performance is achieved when installed according to manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance Ratings (AHRI #215447281)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Heating Capacity (HP @ 47°F)\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e120,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Furnace Fit\u003c\/td\u003e\n\u003ctd\u003eFlush-Fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA6010\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs \/ 198 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CHPEA4830D3\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eGas Furnace — GDVT961205DN\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24-1\/2\" x 28-7\/8\" x 34-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e158 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect Vent (Category IV) — 2\"-3\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eNatural Gas — Standard NOx emissions; verify local air quality district requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotentially eligible — consult IRS guidelines and a qualified tax professional for current 25C\/25D credit requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447281\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star (Heat Pump)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA6010):\u003c\/strong\u003e 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GDVT961205DN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRefer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884533252416,"sku":"GZV6SA6010-CHPEA4830D3-GDVT961205DN","price":8789.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa6010-chpea4830d3-gdvt961205dn-ahri-215447281","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}