{"product_id":"goodman-gzv6sa6010-chpea4830d3-grvt801005cx-ahri-215447285","title":"Goodman 5 Ton 15.5 SEER2 R-32 Dual Fuel System | GZV6SA6010 Heat Pump + CHPEA4830D3 24-1\/2\" Cabinet Height Horizontal Coil + GRVT801005CX 100,000 BTU Downflow Two-Stage Variable-Speed ECM Low NOx Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 5 Ton 15.5 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447285) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GRVT801005CX 100,000 BTU\/h 80% AFUE gas furnace and the CHPEA4830D3 cased horizontal evaporator coil. Rated at 15.5 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V\/1Ph\/60Hz electrical. Dimensions: 37\" W x 12-5\/8\" D x 39\" H. Equipment Weight: 168 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830D3\u003c\/strong\u003e — 4-Ton R-32 Cased Horizontal Cased Evaporator Coil with EEV expansion device. Horizontal configuration. Cabinet Dimensions: 30\" W x 21\" D x 24-1\/2\" H. Ship Weight: 78 lbs. Aluminum coil construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT801005CX\u003c\/strong\u003e — 100,000 BTU\/h Input (80,000 BTU\/h Output) 80% AFUE Two-Stage Low NOx Gas Furnace. Variable-Speed ECM circulator blower motor. Downflow configuration. Cabinet Dimensions: 21\" W x 28\" D x 33-3\/8\" H. Category I (Natural Draft \/ Induced Draft) venting (4\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #c62828;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#c62828;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Downflow furnace installations with this 100,000 BTU two-stage gas furnace require careful attention to combustion air routing and condensate management. In tight closet or garage applications, the 21\" cabinet width can create clearance conflicts with the R-32 refrigerant line connections on the CHPEA4830D3 evaporator coil above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e Verify the condensate trap is installed per manufacturer instructions and confirm the drain slope before startup. R-32 systems operating at higher discharge pressures than R-410A predecessors will produce more condensate at peak cooling. A failed drain in a downflow application means water damage to the heat exchanger and burner assembly — the most expensive callback in HVAC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manometer to confirm negative pressure in the combustion chamber during operation. Target -0.02\" to -0.10\" W.C. at the draft inducer outlet. Document this reading on the commissioning report alongside your micron gauge evacuation record (500 microns or below, held for 10 minutes minimum with R-32).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e This system uses R-32 refrigerant (GWP 675), which is classified as A2L (mildly flammable). Ensure compliance with ASHRAE 15 and local mechanical codes for A2L refrigerant charge limits in occupied spaces. Many jurisdictions now require leak detection equipment for A2L installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Combines 15.5 SEER2 \/ 8.2 HSPF2 heat pump performance with 80% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Airflow Management:\u003c\/strong\u003e The Variable-Speed ECM blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot\/cold spots and lowering operating noise compared to PSC motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Gas Valve:\u003c\/strong\u003e Two-stage gas valve operates at 70% capacity on low fire for most heating demand, reducing temperature swings and gas consumption while reserving full output for the coldest conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified Match:\u003c\/strong\u003e All components are AHRI-certified as a matched system (Certificate #215447285), ensuring rated performance is achieved when installed according to manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance Ratings (AHRI #215447285)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e15.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Heating Capacity (HP @ 47°F)\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e100,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Furnace Fit\u003c\/td\u003e\n\u003ctd\u003e1.75\" Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA6010\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs \/ 198 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CHPEA4830D3\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eGas Furnace — GRVT801005CX\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21\" x 28\" x 33-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e124 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eCategory I (Natural Draft \/ Induced Draft) — 4\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eLow NOx — Compliant with California 40 ng\/J standard (not eligible for SCAQMD or SJVAPCD districts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447285\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star (Heat Pump)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA6010):\u003c\/strong\u003e 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA4830D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT801005CX):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRefer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884532662592,"sku":"GZV6SA6010-CHPEA4830D3-GRVT801005CX","price":7807.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa6010-chpea4830d3-grvt801005cx-ahri-215447285","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}