{"product_id":"goodman-gzv6sa6010-chpea6030d3-grvm971205dn-ahri-215447276","title":"Goodman 5 Ton 16.0 SEER2 R-32 Dual Fuel System | GZV6SA6010 Heat Pump + CHPEA6030D3 21\" Cabinet Height Horizontal Coil + GRVM971205DN 120,000 BTU Upflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003ch2\u003eGoodman 5 Ton 16.0 SEER2 Dual Fuel System Overview\u003c\/h2\u003e\n\u003cp\u003eThis AHRI-certified dual fuel system (Certificate #215447276) pairs the Goodman GZV6SA6010 5-ton R-32 variable-speed heat pump with the GRVM971205DN 120,000 BTU\/h 97% AFUE gas furnace and the CHPEA6030D3 cased horizontal evaporator coil. Rated at 16.0 SEER2 and 8.2 HSPF2, this matched system delivers efficient year-round comfort by automatically switching between electric heat pump operation and gas furnace heating based on outdoor conditions. Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA6010\u003c\/strong\u003e — 5-Ton R-32 Variable-Speed Inverter-Driven Split System Heat Pump. Side discharge configuration with variable-speed swing compressor, EEV metering, and 118 oz. factory R-32 charge. 208-230V\/1Ph\/60Hz electrical. Dimensions: 37\" W x 12-5\/8\" D x 39\" H. Equipment Weight: 168 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e — 5-Ton R-32 Cased Horizontal Cased Evaporator Coil with EEV expansion device. Horizontal configuration. Cabinet Dimensions: 30\" W x 21\" D x 21\" H. Ship Weight: 76 lbs. Aluminum coil construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVM971205DN\u003c\/strong\u003e — 120,000 BTU\/h Input (115,320 BTU\/h Output) 97% AFUE Modulating Natural Gas Gas Furnace. Variable-Speed ECM circulator blower motor. Upflow\/Horizontal configuration. Cabinet Dimensions: 24-1\/2\" W x 28-7\/8\" D x 34-1\/2\" H. Direct Vent (Category IV) venting (2\"-3\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#f5f5f5;border-left:4px solid #c62828;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;color:#c62828;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e This upflow\/horizontal furnace paired with a cased horizontal coil creates a vertical stack that demands careful measurement of total installed height. The furnace stands 34-1\/2\" tall, and the CHPEA6030D3 adds 21\" — verify ceiling clearance in utility closets before committing to this configuration, especially with the flush-fit coil-to-furnace alignment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e With the modulating gas valve and variable-speed blower, ensure the thermostat or control board is properly configured for dual fuel switchover. Set the heat pump balance point based on regional heating design temperature — typically 35°F-40°F for moderate climates, 25°F-30°F for cold climates. An improperly set balance point results in excessive gas consumption that erases the efficiency gains of the 16.0 SEER2 heat pump.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e After completing the R-32 line set connections, evacuate to 500 microns or below using a digital micron gauge (not an analog compound gauge). Hold the vacuum for 10 minutes minimum with the core tool valve closed. R-32 is less forgiving of moisture contamination than R-410A due to its higher discharge temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 (GWP 675) falls under A2L classification per ASHRAE 34. Verify local code adoption of 2024 UMC or IMC provisions for A2L refrigerants. Installers must hold a valid EPA Section 608 certification and should verify charge limits per ASHRAE 15 based on room volume and ventilation rate of the equipment location.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Combines 16.0 SEER2 \/ 8.2 HSPF2 heat pump performance with 97% AFUE gas furnace backup, automatically selecting the most cost-effective heating source based on outdoor conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675 — approximately 68% lower than R-410A (GWP 2088). R-32 also provides approximately 10% better volumetric cooling capacity, contributing to system efficiency gains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Compressor Technology:\u003c\/strong\u003e The inverter-driven variable-speed swing compressor modulates output from approximately 25% to over 100% capacity, matching the exact thermal load for reduced energy consumption and tighter temperature control (±1°F) compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Airflow Management:\u003c\/strong\u003e The Variable-Speed ECM blower motor provides optimized airflow across heating, cooling, and continuous fan modes, reducing hot\/cold spots and lowering operating noise compared to PSC motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModulating Gas Valve:\u003c\/strong\u003e Modulating gas valve adjusts flame output across a continuous range for maximum comfort and efficiency, eliminating the temperature swings associated with fixed-stage operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified Match:\u003c\/strong\u003e All components are AHRI-certified as a matched system (Certificate #215447276), ensuring rated performance is achieved when installed according to manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eSystem Performance Ratings (AHRI #215447276)\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e8.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Heating Capacity (HP @ 47°F)\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e120,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Furnace Fit\u003c\/td\u003e\n\u003ctd\u003eFlush-Fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eOutdoor Unit — GZV6SA6010\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12-5\/8\" x 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment \/ Ship Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs \/ 198 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e31.8A \/ 37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eEvaporator Coil — CHPEA6030D3\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\u003cth colspan=\"2\"\u003eGas Furnace — GRVM971205DN\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24-1\/2\" x 28-7\/8\" x 34-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e156 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect Vent (Category IV) — 2\"-3\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;margin:16px 0;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#333;color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32 refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eNatural Gas — Standard NOx emissions; verify local air quality district requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotentially eligible — consult IRS guidelines and a qualified tax professional for current 25C\/25D credit requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star (Heat Pump)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. All warranties require online registration at www.goodmanmfg.com within 60 days of installation. Registration is not required in California, Florida, or Québec. Warranty durations may differ in Texas and Florida.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Heat Pump (GZV6SA6010):\u003c\/strong\u003e 10-Year Parts Limited Warranty; 10-Year Unit Replacement Limited Warranty (registered). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Without registration, warranty coverage is limited to 5 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030D3):\u003c\/strong\u003e 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. Coil must be matched with an approved outdoor unit to maintain warranty eligibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVM971205DN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (good for as long as the original homeowner owns the home, registered); 10-Year Unit Replacement Limited Warranty; 10-Year Parts Limited Warranty (registered). Without registration, warranty coverage is limited to 5 years. The heat exchanger warranty is contingent upon proper installation and annual professional maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eRefer to each component's warranty documentation for complete terms, conditions, limitations, and exclusions. Warranty claims require proof of proper installation by a licensed HVAC contractor and evidence of timely registration.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884531351872,"sku":"GZV6SA6010-CHPEA6030D3-GRVM971205DN","price":9210.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv6sa6010-chpea6030d3-grvm971205dn-ahri-215447276","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}