{"product_id":"goodman-gzv7sa6010-chpea6030d3-grvt961205dn","title":"Goodman 5 Ton 16.0 SEER2 R-32 Dual Fuel System | GZV7SA6010 | CHPEA6030D3 | GRVT961205DN | 21\" Cabinet Depth Horizontal Coil | 120,000 BTU\/h 96.0% AFUE Downflow Natural Gas Two-Stage Furnace","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif; line-height:1.6; color:#333;\"\u003e\n\n\u003ch2 style=\"color:#005a9c;\"\u003eSystem Overview\u003c\/h2\u003e\n\u003cp\u003eThis Goodman 5-Ton Dual Fuel System pairs the GZV7SA6010 variable-speed, inverter-driven R-32 heat pump condenser with the CHPEA6030D3 cased evaporator coil and the GRVT961205DN 96.0% AFUE gas furnace. The system is AHRI certified (Certificate #216835321) and rated at 16.0 SEER2 \/ 9.8 EER2 \/ 8.5 HSPF2, qualifying for the ENERGY STAR Cold Climate Certified designation.\u003c\/p\u003e\n\u003cp\u003eDual fuel operation automatically switches between electric heat pump heating and gas furnace heating based on outdoor temperature, optimizing both comfort and operating cost across a wide range of climate conditions.\u003c\/p\u003e\n\u003cp style=\"font-style:italic; color:#555;\"\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA6010\u003c\/strong\u003e — Goodman 5-Ton Variable-Speed Inverter-Driven R-32 Side-Discharge Heat Pump Condenser (52,000 BTU\/h Cooling \/ 54,000 BTU\/h Heating @ 47°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030D3\u003c\/strong\u003e — Goodman 5-Ton Cased Horizontal Evaporator Coil, Horizontal, 21\" Cabinet Depth, Internal EEV, All-Aluminum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT961205DN\u003c\/strong\u003e — Goodman 120,000 BTU\/h Input 96.0% AFUE Two-Stage Downflow Gas Furnace, Variable-Speed ECM, Natural Gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #005a9c; padding:15px; margin:15px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip: Dual Fuel Changeover and Line Set Considerations\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e On 5-ton dual fuel installations with R-32 refrigerant, the GZV7SA6010 uses front-and-back sealing service valves with ⅞\" suction valve ports but requires 1⅛\" suction line sets. Installers will need to supply ⅞\" to 1⅛\" adapters for suction line connections. Confirm the furnace’s downflow configuration does not conflict with coil orientation or drain routing before committing to ductwork connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Set the dual fuel changeover (balance point) based on local utility rate structures and climate data, not factory defaults. A misconfigured balance point leads to unnecessary gas consumption in mild shoulder seasons or over-reliance on the heat pump at sub-optimal outdoor temperatures, resulting in nuisance high-pressure lockouts after 6–12 months.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e After final charge, use a digital manifold gauge with R-32 pressure-temperature charts to verify 11±1°F subcooling at the service valve. R-32’s higher operating pressures require careful leak testing with an electronic leak detector rated for A2L (mildly flammable) refrigerants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified as A2L (mildly flammable, GWP 675). All installations must comply with EPA Section 608 certification requirements and ASHRAE 15\/34 safety standards. Ensure adequate ventilation in confined installation spaces per local mechanical code and the unit’s installation instructions. The lower GWP of R-32 compared to R-410A supports AIM Act compliance targets.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Technology:\u003c\/strong\u003e The GZV7SA6010 uses a variable-speed swing compressor with inverter drive, modulating capacity from partial load to full output. This reduces short-cycling, lowers sound levels (as low as 45 dBA in Quiet Mode), and improves humidity control compared to single-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR Cold Climate Certified:\u003c\/strong\u003e This system meets the EPA’s stringent Cold Climate Heat Pump criteria, meaning it maintains effective heating capacity at temperatures well below freezing—delivering 46,000 BTU\/h at 5°F and supporting operation down to -10°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Low-GWP Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential of 675, approximately 68% lower than R-410A (GWP 2,088). This supports AIM Act and EPA Phasedown compliance while delivering improved thermodynamic efficiency per pound of refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Expansion Valve (EEV) Metering:\u003c\/strong\u003e Both the outdoor unit and the indoor coil utilize EEV technology for precise superheat and subcooling control across all operating conditions, reducing energy waste at part-load compared to fixed-orifice systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Economy:\u003c\/strong\u003e Automatic switchover between heat pump and gas furnace heating based on outdoor temperature balance point. The heat pump handles moderate-weather heating at higher efficiency, while the 96.0% AFUE furnace takes over during extreme cold when electric resistance supplemental heat would be cost-prohibitive.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating System Architecture:\u003c\/strong\u003e When paired with a Goodman GTST connected thermostat, the system uses two-wire communicating protocol between indoor and outdoor components for coordinated staging, fault diagnostics, and field-selectable boost mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\" border=\"1\" cellpadding=\"8\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005a9c; color:#fff;\"\u003e\n\u003cth style=\"text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e216835321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e9.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32 (Charge: 162 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eee;font-weight:bold;\"\u003eOutdoor Unit — GZV7SA6010\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity\u003c\/td\u003e\n\u003ctd\u003e52,000 BTU\/h @ 95°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity\u003c\/td\u003e\n\u003ctd\u003e54,000 BTU\/h @ 47°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (Low Temp)\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/h @ 5°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\"W x 12⅝\"D x 56⁵⁄₁₆\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e236 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Range (Cooling)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Range (Heating)\u003c\/td\u003e\n\u003ctd\u003e-10°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eee;font-weight:bold;\"\u003eEvaporator Coil — CHPEA6030D3\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Material\u003c\/td\u003e\n\u003ctd\u003eAll-Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eee;font-weight:bold;\"\u003eGas Furnace — GRVT961205DN\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Input\u003c\/td\u003e\n\u003ctd\u003e120,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-style:italic; color:#555;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eCompliance \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\" border=\"1\" cellpadding=\"8\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005a9c; color:#fff;\"\u003e\n\u003cth style=\"text-align:left;\"\u003eRequirement\u003c\/th\u003e\n\u003cth style=\"text-align:left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGWP (Global Warming Potential)\u003c\/td\u003e\n\u003ctd\u003e675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for all technicians handling R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIM Act Compliance\u003c\/td\u003e\n\u003ctd\u003eR-32 supports EPA HFC phasedown targets (GWP well below the 700 threshold for residential AC\/HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR®\u003c\/td\u003e\n\u003ctd\u003eENERGY STAR Cold Climate Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions (A-Rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eSystems meeting the highest efficiency tier (CEE) may qualify for federal tax credits under the Inflation Reduction Act (25C). Verify current requirements at energystar.gov.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#005a9c;\"\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV7SA6010):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty. With online registration within 60 days of installation: 10-Year Unit Replacement Limited Warranty (if compressor fails, entire outdoor unit is replaced, one time) and 10-Year Parts Limited Warranty for the original registered homeowner. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030D3):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty. With online registration within 60 days of installation: 10-Year Parts Limited Warranty for the original registered homeowner. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GRVT961205DN):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (with registration, good for as long as you own your home). 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty with online registration within 60 days of installation. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em; color:#555;\"\u003eWarranty terms vary by state and province. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. Complete warranty details are available at www.goodmanmfg.com. A licensed contractor must install the system for warranty eligibility.\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658782900544,"sku":"GZV7SA6010-CHPEA6030D3-GRVT961205DN","price":10429.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281","url":"https:\/\/minisplitsystemsdirect.com\/products\/goodman-gzv7sa6010-chpea6030d3-grvt961205dn","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}