{"product_id":"gzv6sa1810-capea3022b3-gmvm970603bn","title":"Goodman 1.5 Ton 19 SEER2 R-32 Dual Fuel System | GZV6SA1810A | CAPEA3022B3 | GMVM970603BN | Communicating 21\" Upflow\/Downflow Coil | 60,000 BTU Upflow\/Horizontal Modulating Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman Dual Fuel System pairs the GZV6SA1810A variable-speed inverter-driven heat pump condenser with the CAPEA3022B3 evaporator coil and the GMVM970603BN 97% AFUE gas furnace for comprehensive year-round heating and cooling. Rated at 19 SEER2 and 8.8 HSPF2 for the heat pump side, and 60,000 BTU input on the furnace, this 1.5-ton R-32 system delivers efficient performance in both moderate and extreme cold conditions. The dual fuel design automatically switches between electric heat pump operation and gas furnace heating based on outdoor temperatures, optimizing energy costs throughout the season. AHRI Certificate Number: 215488167. This is a communicating system, designed for seamless integration with the Goodman GTST connected thermostat and other Goodman communicating equipment for enhanced diagnostics and precise comfort control.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA1810A\u003c\/strong\u003e — Goodman 1.5-Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (19 SEER2 \/ 8.8 HSPF2 \/ 12 EER2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA3022B3\u003c\/strong\u003e — Goodman Cased Upflow\/Downflow Evaporator Coil with Internal EEV (17½\" W x 21\" D x 22\" H, All-Aluminum, R-32 Optimized)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM970603BN\u003c\/strong\u003e — Goodman 97% AFUE 60,000 BTU Upflow\/Horizontal Modulating Gas Furnace with Variable-Speed ECM Motor, Natural Gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background-color:#f0f7fb; border-left:4px solid #2196F3; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e The GZV6SA1810A's 36⅝\" width and side-discharge design means the condenser pad placement must account for both the discharge airflow clearance and the refrigerant line routing to the indoor coil. At 1.5 tons, the ¾\" suction line and ⅜\" liquid line are smaller than typical 2-ton-and-up systems — do not oversize line sets, as this causes oil return issues on the variable-speed compressor at low capacity stages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After completing the final charge procedure per the installation manual (factory charge is for 15' of ⅜\" liquid line), verify subcooling at 10±1°F and confirm the EEV in the indoor coil is cycling correctly through the communicating control board. A stuck or slow-responding EEV on initial startup will manifest as poor heating performance during the first cold snap, typically 4–8 months after a summer installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital micron gauge to verify system evacuation to below 500 microns before charging — R-32's lower GWP does not reduce the importance of proper evacuation. The system's inverter drive board is sensitive to moisture contamination. Confirm the switchover temperature for dual fuel operation is programmed in the thermostat to optimize between heat pump COP and furnace gas cost in your region.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 refrigerant requires EPA Section 608 certification for handling. While R-32 has a lower GWP (675) compared to R-410A (2088), it is classified as A2L (mildly flammable) and requires compliance with ASHRAE 15 and local mechanical codes for charge limits in occupied spaces. Verify all flare connections with a calibrated torque wrench per the manufacturer's specified torque values.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency R-32 Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675, approximately 68% lower than R-410A (GWP 2088), reducing the system's direct environmental impact while maintaining equivalent cooling and heating performance at 19 SEER2 \/ 8.8 HSPF2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Compressor:\u003c\/strong\u003e The swing compressor in the GZV6SA1810A modulates capacity from minimum to maximum output, reducing temperature swings, improving humidity control, and lowering energy consumption compared to single-speed or two-stage systems during partial-load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation with Quiet Mode:\u003c\/strong\u003e Normal operating sound level of 61 dBA, with a three-level Quiet Mode that can reduce sound output to as low as 40 dBA — suitable for installations near bedrooms, patios, or property lines with noise ordinance concerns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Capability:\u003c\/strong\u003e ENERGY STAR® Cold Climate certified, the GZV6SA1810A operates in heating mode down to -10°F ambient, providing 13,000 BTU\/h at 5°F outdoor temperature for reliable heat pump operation in northern climates without auxiliary heat dependency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Cost Optimization:\u003c\/strong\u003e Automatically transitions between heat pump operation (higher COP at moderate temperatures) and gas furnace heating (more economical at extreme cold) based on a field-adjustable switchover temperature, delivering the lowest combined operating cost across the full heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModulating Gas Furnace Technology:\u003c\/strong\u003e The 97% AFUE furnace features a modulating gas valve that adjusts flame intensity in fine increments, maximizing fuel efficiency and minimizing temperature fluctuations compared to single-stage or two-stage furnaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Expansion Valve (EEV):\u003c\/strong\u003e The EEV provides continuous, precise refrigerant metering that adjusts in real-time to changing load conditions — a significant upgrade over fixed-orifice pistons or standard TXVs for maintaining optimal system efficiency across the full operating range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAHRI Certificate Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e215488167\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background-color:#e8e8e8;\"\u003eOutdoor Unit — GZV6SA1810A\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e17,100 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 47°F (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e17,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd\u003e13,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e19.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e12.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e12.8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e36⅝\" x 13¾\" x 27⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e122 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e61 \/ 61 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ ¾\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Refrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e74 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background-color:#e8e8e8;\"\u003eEvaporator Coil — CAPEA3022B3\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e17½\" x 21\" x 22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e2.5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e48 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background-color:#e8e8e8;\"\u003eGas Furnace — GMVM970603BN\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Input\u003c\/td\u003e\n\u003ctd\u003e60,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve\u003c\/td\u003e\n\u003ctd\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e17½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissions\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (approximately 68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA 608 Certification Required\u003c\/td\u003e\n\u003ctd\u003eYes — Required for purchase, handling, and servicing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215488167\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR® Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 regional efficiency standards for all U.S. regions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE 15 Compliance\u003c\/td\u003e\n\u003ctd\u003eRequired — Charge limits apply for A2L refrigerant in occupied spaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissions Compliance\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas emissions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eThis system may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a qualified tax professional and visit energystar.gov for current eligibility requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV6SA1810A) Warranty:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUnregistered: 5-Year Parts Limited Warranty\u003c\/li\u003e\n\u003cli\u003eRegistered (within 60 days of installation at goodmanmfg.com): 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty\u003c\/li\u003e\n\u003cli\u003eCompressor: If the compressor fails within the first 10 years (registered unit), Goodman will furnish a new equivalent replacement unit at no charge (one-time)\u003c\/li\u003e\n\u003cli\u003eOptional: One-time compressor replacement coverage for years 11–99 available through an ASURE Extend Service Plan\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CAPEA3022B3) Warranty:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUnregistered: 5-Year Parts Limited Warranty\u003c\/li\u003e\n\u003cli\u003eRegistered (within 60 days of installation at goodmanmfg.com): 10-Year Parts Limited Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GMVM970603BN) Warranty:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUnregistered: 20-Year Heat Exchanger Limited Warranty + 5-Year All Other Parts Limited Warranty\u003c\/li\u003e\n\u003cli\u003eRegistered (within 60 days of installation at goodmanmfg.com): Lifetime Heat Exchanger Limited Warranty (up to 99 years) + 10-Year Parts Limited Warranty + 10-Year Unit Replacement Limited Warranty (heat exchanger failure)\u003c\/li\u003e\n\u003cli\u003eIf the heat exchanger fails within the first 10 years (registered unit), Goodman will furnish a new equivalent replacement unit at no charge (one-time)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Online registration must be completed within 60 days of installation to receive the full extended warranty coverage. Registration is not required in California, Florida, or Québec. Warranty durations in Texas and Florida may differ. All warranties apply to owner-occupied residential installations only. Complete warranty details are available at goodmanmfg.com.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51881936027968,"sku":"GZV6SA1810-CAPEA3022B3-GMVM970603BN","price":6036.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/EFSEJFSUIEJFSEed.jpg?v=1777342779","url":"https:\/\/minisplitsystemsdirect.com\/products\/gzv6sa1810-capea3022b3-gmvm970603bn","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}