{"product_id":"gzv6sa4210-chpea4830d3-grvt800805dn-215447243","title":"Goodman 3.5 Ton 17 SEER2 R-32 Dual Fuel System | GZV6SA4210 + CHPEA4830D3 + GRVT800805DN | 24½\" Cabinet Height Horizontal Cased Coil | 80,000 BTU\/h Downflow Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis AHRI-certified Goodman 3.5-ton Dual Fuel System (AHRI Ref. #215447243) pairs the GZV6SA4210 variable-speed, inverter-driven R-32 heat pump condenser with the CHPEA4830D3 evaporator coil and the GRVT800805DN 80% AFUE gas furnace. Rated at 17.0 SEER2 and 7.5 HSPF2 for the heat pump portion, this dual fuel configuration automatically switches between electric heat pump operation and gas furnace heating based on outdoor temperature to optimize both comfort and operating cost. The system delivers up to 40,000 BTU\/h in combined heating capacity and uses R-32 refrigerant (GWP 675), a lower-GWP alternative to R-410A that supports evolving EPA regulations.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV6SA4210\u003c\/strong\u003e — Goodman 3.5-Ton Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser (37\"W x 12⅝\"D x 39\"H, 168 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830D3\u003c\/strong\u003e — Goodman Horizontal Cased Evaporator Coil with Electronic Expansion Valve (EEV), All-Aluminum Coil, R-32 Optimized (30\" x 21\" x 24½\", 78 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGRVT800805DN\u003c\/strong\u003e — Goodman 80% AFUE Downflow Two-Stage Gas Furnace, 80,000 BTU\/h Input, Variable-Speed ECM, Natural Gas (24½\" x 28\" x 33⅜\", 129 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"background-color:#f0f7fb;border-left:4px solid #2196F3;padding:15px;margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e Dual fuel systems with R-32 require careful attention to the changeover balance point. The GZV6S variable-speed heat pump operates efficiently down to -10°F ambient, but the switchover to the GRVT800805DN furnace must be programmed based on the regional utility rate crossover — not just outdoor temperature. In communicating mode, only two low-voltage wires run to the outdoor unit, but confirm the indoor coil's EEV wiring harness is properly seated before commissioning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After initial startup, verify subcooling at the service valve reads 8±1°F per the GZV6S specification for this tonnage. Out-of-spec subcooling on day one creates compressor bearing wear that shows up as a warranty call at month 14. Install a field bi-flow filter drier (included) on the liquid line and pull the system to 350 microns or below before releasing the 100 oz factory charge.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 PT charts (Testo 557s or equivalent) to confirm operating pressures. R-32 operates at approximately 15% higher discharge pressures than R-410A — standard gauge sets without updated scales will give misleading readings. Verify superheat is in auto-control mode via the seven-segment LED display on the outdoor unit control board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as A2L (mildly flammable). EPA Section 608 certification is required for handling. Ensure the installation meets the latest edition of ASHRAE 15 and UL 60335-2-40 charge-size limits for the installed space. For California installations with Natural Gas furnaces, confirm SCAQMD district compliance before commissioning the gas furnace portion.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eKey System Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Efficiency:\u003c\/strong\u003e Automatically transitions between the 17.0 SEER2 \/ 7.5 HSPF2 heat pump and the 80% AFUE gas furnace at the programmed balance point, optimizing energy cost across all outdoor conditions from -10°F to 115°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Comfort:\u003c\/strong\u003e The GZV6S inverter-driven swing compressor and the furnace's variable-speed ECM blower work together to deliver precise temperature control and reduced temperature swings compared to single-speed systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower-GWP Refrigerant:\u003c\/strong\u003e R-32 (GWP 675) reduces the system's direct environmental impact by approximately 68% compared to equivalent R-410A systems (GWP 2,088), aligning with EPA AIM Act phase-down requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The outdoor unit features a high-density compressor sound blanket, digitally commutated fan motor, and field-selectable Quiet Mode with up to three sound levels (as low as 45 dBA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Aluminum Indoor Coil:\u003c\/strong\u003e The CHPEA4830D3 evaporator coil features an all-aluminum construction optimized for R-32, eliminating galvanic corrosion between dissimilar metals and improving long-term reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215447243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e3.5 Tons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e7.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Charge\u003c\/td\u003e\n\u003ctd\u003e100 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background-color:#f2f2f2;\"\u003e\u003cstrong\u003eOutdoor Unit — GZV6SA4210\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity (95°F)\u003c\/td\u003e\n\u003ctd\u003e41,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e40,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e27,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\"W x 12⅝\"D x 39\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight\u003c\/td\u003e\n\u003ctd\u003e168 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e31.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" O.D.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e1⅛\" O.D.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background-color:#f2f2f2;\"\u003e\u003cstrong\u003eIndoor Coil — CHPEA4830D3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eHorizontal, Cased\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Expansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Ship Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background-color:#f2f2f2;\"\u003e\u003cstrong\u003eGas Furnace — GRVT800805DN\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Output (est.)\u003c\/td\u003e\n\u003ctd\u003e64,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissions\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 28\" x 33⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Ship Weight\u003c\/td\u003e\n\u003ctd\u003e129 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Electrical\u003c\/td\u003e\n\u003ctd\u003e115V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#f2f2f2;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (vs. 2,088 for R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eCertification required for handling R-32; subject to AIM Act HFC phase-down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes — Certificate #215447243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll Regions (verify local A2L refrigerant adoption status)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissions Compliance\u003c\/td\u003e\n\u003ctd\u003eStandard NOx — not rated for California SCAQMD districts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit (25C)\u003c\/td\u003e\n\u003ctd\u003eVerify eligibility at energystar.gov — tax credit requirements are subject to change.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eOutdoor Unit (GZV6SA4210) — Heat Pump Condenser:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnregistered:\u003c\/strong\u003e 5-Year Parts Limited Warranty from installation date.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegistered (within 60 days of installation):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty (good for as long as the original registered owner occupies the home, up to 10 years). If the compressor or outdoor unit fails during the registered warranty period, Goodman will furnish a replacement unit at no charge for the unit (labor not included).\u003c\/li\u003e\n\u003cli\u003eRegistration: \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003ewww.goodmanmfg.com\u003c\/a\u003e → Product Registration within 60 days of installation.\u003c\/li\u003e\n\u003cli\u003eOnline registration is not required in California, Florida, or Québec.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEvaporator Coil (CHPEA4830D3):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnregistered:\u003c\/strong\u003e 5-Year Parts Limited Warranty from installation date.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegistered (within 60 days of installation):\u003c\/strong\u003e 10-Year Parts Limited Warranty.\u003c\/li\u003e\n\u003cli\u003eRegistration: \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003ewww.goodmanmfg.com\u003c\/a\u003e → Product Registration within 60 days of installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGas Furnace (GRVT800805DN):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnregistered:\u003c\/strong\u003e 20-Year Heat Exchanger Limited Warranty and 5-Year Parts Limited Warranty from installation date.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegistered (within 60 days of installation):\u003c\/strong\u003e Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns and resides in the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty. If the heat exchanger fails within the first 10 years, Goodman will furnish a complete replacement furnace. The heat exchanger is warranted for years 11–99 after installation for registered owners.\u003c\/li\u003e\n\u003cli\u003eRegistration: \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003ewww.goodmanmfg.com\u003c\/a\u003e → Product Registration within 60 days of installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eImportant: All warranty coverage requires installation by a licensed contractor in an owner-occupied residence. Units ordered online must be installed by a dealer adhering to all applicable codes. Labor, refrigerant, freight, and associated service costs are not covered under any warranty tier. Warranty terms may differ in Texas and Florida. See complete warranty documents for full terms, limitations, and exclusions.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51884460245312,"sku":"GZV6SA4210-CHPEA4830D3-GRVT800805DN","price":6790.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651","url":"https:\/\/minisplitsystemsdirect.com\/products\/gzv6sa4210-chpea4830d3-grvt800805dn-215447243","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}