{"product_id":"gzv7sa4810-ahve60dp0300-215429752","title":"Goodman | 4 Ton | 17.5 SEER2 | R-32 | Central Heat Pump Split System | GZV7SA4810 | AHVE60DP0300 | 24½\" Multi-Positional Air Handler","description":"\u003cp\u003eThis Goodman 4-Ton Central Heat Pump Split System pairs the GZV7SA4810 variable-speed, inverter-driven R-32 heat pump condenser with the AHVE60DP0300 multi-positional air handler. AHRI certified under #215429752, this matched system achieves up to 17.5 SEER2 and 8.8 HSPF2.\u003c\/p\u003e\n\u003cp\u003eThis system is ENERGY STAR® Most Efficient certified and qualifies as a Cold Climate Heat Pump.\u003c\/p\u003e\n\u003cp\u003eR-32 refrigerant offers a 67.5% lower Global Warming Potential (GWP of 675) compared to R-410A (GWP of 2,088), aligning with EPA regulations and the AIM Act phase-down schedule.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA4810\u003c\/strong\u003e — Goodman GZV7S Series 4-Ton Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser. Features variable-speed swing compressor, EEV metering, and communicating capability. Rated up to 46,500 BTU\/h cooling and 47,500 BTU\/h heating at 47°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHVE60DP0300\u003c\/strong\u003e — Goodman AHVE Series Multi-Positional Air Handler with variable-speed ECM blower motor and factory-installed electronic expansion valve (EEV). All-aluminum evaporator coil optimized for R-32. Cabinet width: 24½\"; depth: 21\".\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background-color:#f0f7ff;border-left:4px solid #0066cc;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e The AHVE air handler's 21\" cabinet depth is designed for attic access, but verify ceiling joist spacing accommodates the full footprint before positioning. Route the condensate drain with proper P-trap and slope to prevent standing water in the secondary drain pan.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e Commission the system in communicating mode to enable full variable-speed modulation. Set the correct tonnage and airflow parameters through the connected thermostat — incorrect setup defaults to legacy mode and sacrifices the efficiency gains that justify the SEER2 rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e After evacuation, confirm the system holds below 500 microns for a minimum of 10 minutes using a digital micron gauge. Verify subcooling at the service valve reads 9±1°F per GZV7S specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 installations require EPA Section 608 certification and compliance with ASHRAE 34 A2L safety classifications. Check local mechanical code requirements for refrigerant detector placement in confined spaces.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 17.5 SEER2 and 8.8 HSPF2 — AHRI-certified matched system efficiency reduces operating costs compared to minimum-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant with GWP of 675 — a 67.5% reduction from R-410A, supporting EPA AIM Act compliance and reducing environmental impact without sacrificing performance.\u003c\/li\u003e\n\u003cli\u003eVariable-speed inverter-driven compressor adjusts capacity continuously to match load, reducing temperature swings, improving dehumidification, and lowering sound levels in part-load conditions.\u003c\/li\u003e\n\u003cli\u003eENERGY STAR® Most Efficient and Cold Climate Heat Pump certified — may qualify for federal tax credits up to $2,000 under the Inflation Reduction Act (IRA) Section 25C for qualifying heat pump systems.\u003c\/li\u003e\n\u003cli\u003eQuiet-mode operation reduces outdoor sound levels to as low as 45 dBA (sound pressure at 3 feet), equivalent to a quiet library environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eAHRI-Certified System Ratings\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215429752\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (M1)\u003c\/td\u003e\n\u003ctd\u003e46,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity – High (M1) @ 47°F\u003c\/td\u003e\n\u003ctd\u003e47,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd\u003e29,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eOutdoor Unit — GZV7SA4810\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e37\" × 12⅝\" × 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230\/1\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Overcurrent Protection (MOCP)\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line Size\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line Size\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Rating (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e73\/73 dBA (Sound Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eAir Handler — AHVE60DP0300\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W × D)\u003c\/td\u003e\n\u003ctd\u003e24½\" × 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eMulti-Positional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM (1 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e167 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-size:0.9em;font-style:italic;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eCompliance \u0026amp; Environmental Data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (67.5% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnician certification required for handling R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIM Act Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets HFC phase-down requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR®\u003c\/td\u003e\n\u003ctd\u003eMost Efficient \/ Cold Climate Heat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eMay qualify for up to $2,000 federal tax credit under IRA Section 25C for heat pump systems meeting CEE highest efficiency tier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 regional efficiency standards for all U.S. regions. Verify local mechanical permit and refrigerant detection requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV7SA4810):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered online at goodmanmfg.com within 60 days of installation: 10-Year Registered Parts Limited Warranty plus 10-Year Unit Replacement Limited Warranty for compressor failure (one-time replacement of entire unit). Registration required in most states. Warranty applies to owner-occupied residences only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Handler (AHVE60DP0300):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Registered Parts Limited Warranty for all parts. Applies to owner-occupied residential installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegistration Deadline:\u003c\/strong\u003e Online registration must be completed within 60 days of installation at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003ewww.goodmanmfg.com\u003c\/a\u003e. Registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e All warranty coverage requires installation by a licensed HVAC contractor adhering to federal, state, and local codes. Warranty does not cover units installed in non-owner-occupied residences or commercial properties. Units ordered online must be installed by a qualifying dealer.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658770612544,"sku":"GZV7SA4810-AHVE60DP0300-215429752","price":6880.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/BMitled.jpg?v=1777641264","url":"https:\/\/minisplitsystemsdirect.com\/products\/gzv7sa4810-ahve60dp0300-215429752","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}