{"product_id":"gzv7sa4810-chpea6030c3-gdvt960804cn-215434457","title":"Goodman | 4 Ton | 16.2 SEER2 | R-32 | Dual Fuel System | GZV7SA4810 | CHPEA6030C3 | GDVT960804CN | 30\" Horizontal Coil | 80,000 BTU Downflow\/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace","description":"\u003cp\u003eThis Goodman 4-Ton Dual Fuel System pairs the GZV7SA4810 variable-speed, inverter-driven R-32 heat pump condenser with the CHPEA6030C3 horizontal evaporator coil and the GDVT960804CN 96% AFUE gas furnace. AHRI certified under #215434457, this matched configuration delivers up to 16.2 SEER2 and 8.5 HSPF2 efficiency ratings.\u003c\/p\u003e\n\u003cp\u003eThe two-stage, variable-speed ecm furnace provides 80,000 BTU\/h input (76,800 BTU\/h output) for reliable supplemental heating when outdoor temperatures drop below the heat pump balance point.\u003c\/p\u003e\n\u003cp\u003eThis system is ENERGY STAR® Most Efficient certified and qualifies as a Cold Climate Heat Pump.\u003c\/p\u003e\n\u003cp\u003eR-32 refrigerant offers a 67.5% lower Global Warming Potential (GWP of 675) compared to R-410A (GWP of 2,088), aligning with EPA regulations and the AIM Act phase-down schedule.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV7SA4810\u003c\/strong\u003e — Goodman GZV7S Series 4-Ton Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser. Features variable-speed swing compressor, EEV metering, and communicating capability. Rated up to 46,500 BTU\/h cooling and 47,500 BTU\/h heating at 47°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA6030C3\u003c\/strong\u003e — Goodman CHPEA Series Cased Horizontal Evaporator Coil with factory-installed electronic expansion valve (EEV). All-aluminum coil optimized for R-32 refrigerant. Cabinet width: 30\"; depth: 21\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDVT960804CN\u003c\/strong\u003e — Goodman GDVT Series 96% AFUE Two-Stage, Variable-Speed ECM Gas Furnace. 80,000 BTU\/h input capacity (Natural Gas compliant). Downflow\/Horizontal configuration with 21\" cabinet width.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background-color:#f0f7ff;border-left:4px solid #0066cc;padding:16px;margin:20px 0;\"\u003e\n\u003ch4 style=\"margin-top:0;\"\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e When installing this dual fuel system, the R-32 refrigerant requires careful attention to line set connections. The GZV7SA4810 uses ⅜\" liquid and 1⅛\" suction lines, but the service valves are ⅞\" — you will need ⅞\" to 1⅛\" adapters for suction connections. In attic or closet installations, verify the 30\" coil width clears the available space alongside the 21\" furnace cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e R-32 is mildly flammable (A2L classification), so verify all brazed connections with an electronic leak detector rated for R-32 before commissioning. A thorough leak check at installation prevents nuisance low-charge fault codes 6–12 months down the road, especially in systems with long line sets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e After evacuation, confirm the system holds below 500 microns for a minimum of 10 minutes using a digital micron gauge. The GZV7S units ship with 118 oz of R-32 charge, sized for 15 feet of ⅜\" liquid line — adjust per the installation manual charge procedure for actual line set length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 systems must comply with ASHRAE 34 safety classification standards and EPA Section 608 technician certification requirements. Many jurisdictions also require a mechanical permit for dual fuel installations that connect to gas service. In California SCAQMD areas, verify the furnace model meets applicable low-NOx emission requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 16.2 SEER2 and 8.5 HSPF2 — AHRI-certified matched system efficiency reduces operating costs compared to minimum-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant with GWP of 675 — a 67.5% reduction from R-410A, supporting EPA AIM Act compliance and reducing environmental impact without sacrificing performance.\u003c\/li\u003e\n\u003cli\u003eVariable-speed inverter-driven compressor adjusts capacity continuously to match load, reducing temperature swings, improving dehumidification, and lowering sound levels in part-load conditions.\u003c\/li\u003e\n\u003cli\u003eENERGY STAR® Most Efficient and Cold Climate Heat Pump certified — may qualify for federal tax credits up to $2,000 under the Inflation Reduction Act (IRA) Section 25C for qualifying heat pump systems.\u003c\/li\u003e\n\u003cli\u003eQuiet-mode operation reduces outdoor sound levels to as low as 45 dBA (sound pressure at 3 feet), equivalent to a quiet library environment.\u003c\/li\u003e\n\u003cli\u003eDual fuel switchover provides gas furnace backup heating (80,000 BTU\/h input at 96% AFUE) when outdoor temperatures drop below the heat pump economic balance point, optimizing operating cost in cold climates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eAHRI-Certified System Ratings\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e215434457\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (M1)\u003c\/td\u003e\n\u003ctd\u003e45,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity – High (M1) @ 47°F\u003c\/td\u003e\n\u003ctd\u003e46,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd\u003e29,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eOutdoor Unit — GZV7SA4810\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e37\" × 12⅝\" × 39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e179 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230\/1\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Overcurrent Protection (MOCP)\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e118 oz R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line Size\u003c\/td\u003e\n\u003ctd\u003e⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line Size\u003c\/td\u003e\n\u003ctd\u003e1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Rating (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e73\/73 dBA (Sound Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eEvaporator Coil — CHPEA6030C3\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Dimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e30\" × 21\" × 24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eGas Furnace — GDVT960804CN\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capacity\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e76,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Valve\u003c\/td\u003e\n\u003ctd\u003eTwo-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width × Depth × Height\u003c\/td\u003e\n\u003ctd\u003e21\" × 28⅞\" × 34½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Type \/ Diameter\u003c\/td\u003e\n\u003ctd\u003eDirect Vent (PVC) \/ 2\" - 3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissions\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-size:0.9em;font-style:italic;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#e8e8e8;text-align:center;\"\u003eCompliance \u0026amp; Environmental Data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (67.5% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eTechnician certification required for handling R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIM Act Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets HFC phase-down requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR®\u003c\/td\u003e\n\u003ctd\u003eMost Efficient \/ Cold Climate Heat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eMay qualify for up to $2,000 federal tax credit under IRA Section 25C for heat pump systems meeting CEE highest efficiency tier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 regional efficiency standards for all U.S. regions. Verify local mechanical permit and refrigerant detection requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard Natural Gas — verify local air quality district requirements before installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit (GZV7SA4810):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered online at goodmanmfg.com within 60 days of installation: 10-Year Registered Parts Limited Warranty plus 10-Year Unit Replacement Limited Warranty for compressor failure (one-time replacement of entire unit). Registration required in most states. Warranty applies to owner-occupied residences only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator Coil (CHPEA6030C3):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Registered Parts Limited Warranty. Applies to owner-occupied residential installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Furnace (GDVT960804CN):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty for all parts and 20-Year Heat Exchanger Limited Warranty (unregistered). When registered within 60 days: 10-Year Registered Parts Limited Warranty for all parts, plus extended heat exchanger coverage for the life of the original registered owner (up to applicable limits). Applies to owner-occupied residential installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegistration Deadline:\u003c\/strong\u003e Online registration must be completed within 60 days of installation at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003ewww.goodmanmfg.com\u003c\/a\u003e. Registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e All warranty coverage requires installation by a licensed HVAC contractor adhering to federal, state, and local codes. Warranty does not cover units installed in non-owner-occupied residences or commercial properties. Units ordered online must be installed by a qualifying dealer.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51658769596736,"sku":"GZV7SA4810-CHPEA6030C3-GDVT960804CN-215434457","price":8509.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/THRTHTFHFJJd.jpg?v=1777341651","url":"https:\/\/minisplitsystemsdirect.com\/products\/gzv7sa4810-chpea6030c3-gdvt960804cn-215434457","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}