{"product_id":"gzv9sa361c-ahve60dp0300","title":"Goodman 3 Ton 19.0 SEER2 R-32 | Central Heat Pump Split System | GZV9SA361C + AHVE60DP0300 | 24½\" Cabinet Width | Multi-Positional Air Handler","description":"\u003cdiv style=\"margin-bottom:20px;\"\u003e\n\u003cp\u003eThis Goodman 3-Ton Central Heat Pump Split System pairs the \u003cstrong\u003eGZV9SA361C\u003c\/strong\u003e variable-speed, inverter-driven R-32 heat pump condenser with the \u003cstrong\u003eAHVE60DP0300\u003c\/strong\u003e Multi-Positional Variable-Speed Air Handler with internal EEV. This AHRI-certified combination (Certificate #216699912) achieves up to \u003cstrong\u003e19.0 SEER2\u003c\/strong\u003e \/ \u003cstrong\u003e9.2 HSPF2\u003c\/strong\u003e \/ \u003cstrong\u003e11.7 EER2\u003c\/strong\u003e, qualifying for ENERGY STAR® Most Efficient 2025 and Cold Climate Heat Pump (ccHP) designation. The system operates on low-GWP R-32 refrigerant (GWP: 675), supporting the EPA AIM Act phasedown requirements and potentially qualifying for federal energy efficiency tax credits under IRS Section 25C.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv style=\"margin-bottom:20px;\"\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA361C (GZV9SA361C*)\u003c\/strong\u003e — 3-Ton Variable-Speed, Inverter-Driven, Side-Discharge R-32 Heat Pump Condenser with dual variable-speed swing compressors, EEV metering, quiet-mode capability (as low as 45 dBA), and hot gas base pan defrost down to 5°F. 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHVE60DP0300\u003c\/strong\u003e — Multi-Positional Variable-Speed Air Handler, Multi-Positional configuration, 24½\"W x 21\"D, 1 HP VS-ECM blower motor. Variable-speed ECM blower, SmartFrame™ cabinet, internal EEV, and 21\" depth for attic access. 115V operational voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cdiv style=\"background:#f8f9fa; border-left:4px solid #1a73e8; padding:16px; margin:20px 0;\"\u003e\n\u003ch3\u003e⚙ Pro-Installer Tip\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e[Technical Friction]\u003c\/strong\u003e The AHVE air handler's 21\" depth is designed for attic and closet access, but vertical installations with 24½\" cabinet width require verifying the return-air plenum clearance before setting the unit. The internal EEV eliminates a separate TXV\/piston at the coil, but the communicating wire connection between the GZV9S condenser and AHVE air handler must be run as a dedicated 2-wire (not shared with other low-voltage circuits) for proper inverter communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e[Long-Term Prevention]\u003c\/strong\u003e After startup, run the system for at least 15 minutes in cooling mode and verify subcooling at 11±1°F. The AHVE's variable-speed ECM blower will auto-adjust airflow, but confirm static pressure across the air handler stays below 0.5\" w.c. to prevent blower ramp-up noise and premature motor wear. A clogged filter in the first year is the #1 cause of \"noisy system\" callbacks on variable-speed air handlers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e[Expert Validation]\u003c\/strong\u003e Use an R-32-compatible digital manifold and verify the AHVE's built-in R-32 sensor is operational during commissioning (LED status on control board). A calibrated flow hood at each supply register confirms the system is delivering rated CFM—critical for achieving the rated 19.0 SEER2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e[Professional Standard]\u003c\/strong\u003e EPA Section 608 certification is required for R-32 handling. The AHVE cabinet meets ASHRAE 193 air leakage standards (\u0026lt;2.0% at 1.0\" w.c.), but field-installed ductwork connections must be sealed with UL 181-rated mastic to maintain system efficiency and comply with IECC 2021 duct leakage requirements.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv style=\"margin-bottom:20px;\"\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Certification:\u003c\/strong\u003e The GZV9S operates down to -20°F ambient, providing reliable heat pump heating in extreme cold without solely relying on auxiliary heat, reducing energy consumption in northern climates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The swing compressor modulates capacity from approximately 25% to 100% (and boost mode), maintaining tighter temperature control (±0.5°F) and reducing on\/off cycling compared to single-stage or two-stage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S features three selectable quiet-mode levels with sound output as low as 45 dBA in quiet mode—comparable to a quiet library. Standard cooling mode measures approximately 59 dBA @ 5 ft (1 reflective surface).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential of 675, approximately 68% lower than R-410A (GWP 2,088). This reduces the system's direct environmental impact while also improving thermodynamic efficiency due to R-32's higher volumetric capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Air Handler with EEV:\u003c\/strong\u003e The AHVE air handler includes a factory-installed electronic expansion valve optimized for R-32, variable-speed ECM blower for dehumidification control, and SmartFrame™ cabinet with \u0026lt;2% air leakage per ASHRAE 193.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21\" Cabinet Depth:\u003c\/strong\u003e The AHVE's 21\" depth fits through standard attic access openings without requiring cabinet disassembly, reducing installation time and material cost in retrofit applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cdiv style=\"margin-bottom:20px;\"\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #ddd;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"padding:8px; border:1px solid #ddd; text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:8px; border:1px solid #ddd; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAHRI Certificate #\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e216699912\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eSystem Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCentral Heat Pump Split System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e3 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eSEER2\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e19.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eEER2\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e11.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e9.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMax. Cooling Capacity (95°F)\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e34,200 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMax. Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e34,200 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eExpansion Device\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eElectronic Expansion Valve (EEV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCondenser Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e37\"W x 12⅝\"D x 56 5\/16\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCondenser Weight\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCondenser Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMCA \/ MOCP (Condenser)\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e21.8A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eLiquid Line \/ Suction Line\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e⅜\" \/ ⅞\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eFactory Refrigerant Charge\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e162 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAmbient Operating Range (Cooling)\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e0°F to 115°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAmbient Operating Range (Heating)\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e-20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAir Handler Model\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAHVE60DP0300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAir Handler Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMulti-Positional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAir Handler Cabinet Width\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e24½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAir Handler Depth\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAir Handler Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e115V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eBlower Motor\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e1 HP VS-ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAir Handler Ship Weight\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e167 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCoil-to-Condenser Fit\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eENERGY STAR®\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eENERGY STAR Most Efficient 2025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCold Climate HP\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size:0.9em; color:#666;\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv style=\"margin-bottom:20px;\"\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; border:1px solid #ddd;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"padding:8px; border:1px solid #ddd; text-align:left;\"\u003eCategory\u003c\/th\u003e\n\u003cth style=\"padding:8px; border:1px solid #ddd; text-align:left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eR-32 (Difluoromethane) — A2L (Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e675 (68% lower than R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOzone Depletion Potential (ODP)\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRequired for purchase, handling, and installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eEPA AIM Act Compliance\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCompliant — R-32 is an approved low-GWP alternative under the AIM Act phasedown schedule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUL Safety Standard\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUL 60335-2-40 (A2L refrigerant safety)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAHRI Certification\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAHRI Certified — Certificate #216699912\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eENERGY STAR®\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMost Efficient 2025 — Cold Climate Heat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003ePotentially eligible under IRS Section 25C (up to $2,000) for qualifying heat pump systems meeting CEE highest efficiency tier — verify with tax professional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eVerify local AHJ acceptance of A2L refrigerant equipment. Most jurisdictions adopting 2021+ IMC\/UMC codes permit A2L installations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cdiv style=\"margin-bottom:20px;\"\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eAll warranty terms below require online registration at \u003cstrong\u003ewww.goodmanmfg.com\u003c\/strong\u003e within \u003cstrong\u003e60 days\u003c\/strong\u003e of installation to receive the full Registered Additional Term Warranty. Without registration, coverage defaults to the Initial Term Warranty (5-year parts). Registration is not required in California, Florida, or Québec.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA361C (Heat Pump Condenser):\u003c\/strong\u003e 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty (if compressor fails within the first 10 years of registered ownership, Daikin will furnish an equivalent replacement unit, one time). One-time Compressor Replacement coverage is available for years 11–99 through an ASURE Extend Service Plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHVE60DP0300 (Air Handler):\u003c\/strong\u003e 10-Year Parts Limited Warranty when properly registered. Covers all parts including the variable-speed ECM blower motor, EEV, and factory-installed R-32 sensor that fail under normal use and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:0.9em; color:#666;\"\u003e\u003cem\u003eComplete warranty details are available from your local dealer or at www.goodmanmfg.com. The duration of warranty coverage in Texas and Florida may differ in some cases. Units must be installed by a licensed contractor adhering to all applicable federal, state, and local codes.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657832268096,"sku":"GZV9SA361C-AHVE60DP0300","price":8446.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/SDFSDFSDFSEd_337f2632-9318-430d-83bb-de55d97643e7.jpg?v=1777643113","url":"https:\/\/minisplitsystemsdirect.com\/products\/gzv9sa361c-ahve60dp0300","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}