{"product_id":"gzv9sa4810-chpea4830c3-gmvs960805cu","title":"Goodman 4 Ton 16.2 SEER2 R-32 Dual Fuel System | GZV9SA4810 + CHPEA4830C3 + GMVS960805CU | Communicating | 21\" Horizontal Coil | 80,000 BTU Upflow\/Horizontal Single-Stage Variable-Speed ECM Ultra Low NOx Furnace","description":"\u003cp\u003eThis Goodman 4 Ton 16.2 SEER2 Dual Fuel System pairs the GZV9SA4810 variable-speed inverter-driven heat pump condenser with the GMVS960805CU single-stage gas furnace (96% AFUE, 80,000 BTU) and a CHPEA4830C3 evaporator coil for year-round heating and cooling using R-32 refrigerant. The system operates at up to 16.2 SEER2 \/ 10.5 EER2 in cooling and 8.5 HSPF2 in heat pump mode, with gas furnace backup for extreme cold conditions. AHRI Certificate Number: 217989225. Energy Star Cold Climate Certified (heat pump).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810\u003c\/strong\u003e — Goodman 4 Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser (Side Discharge). Max Cooling: 46,000 BTU\/h; Max Heating @47°F: 48,000 BTU\/h. EEV metering, 208-230V \/ 1 Phase \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830C3\u003c\/strong\u003e — Goodman 4 Ton Cased Horizontal Indoor Coil. Horizontal configuration, all-aluminum coil with factory-installed EEV, R-32 sensor. Cabinet: 30\" W x 21\" D x 21\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVS960805CU\u003c\/strong\u003e — Goodman 80,000 BTU 96% AFUE Single-Stage Variable-Speed ECM Gas Furnace. Upflow\/Horizontal configuration, Single-Stage gas valve, Ultra Low NOx. Aluminized-Steel Tubular primary heat exchanger, Stainless-Steel secondary heat exchanger. ComfortBridge™ communicating technology, 115 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7; border-left:4px solid #0056b3; padding:15px; margin:20px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip: Dual Fuel Changeover \u0026amp; Refrigerant Line Adaptation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThe Technical Friction:\u003c\/strong\u003e The GZV9S heat pump uses ⅞\" suction service valves but requires 1⅛\" suction line sets — installers must supply ⅞\" to 1⅛\" adapters at the condenser. Additionally, dual fuel changeover point calibration requires verifying the outdoor thermostat lockout setting matches your climate zone's economic balance point (typically 30–35°F in most regions).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Long-Term Prevention:\u003c\/strong\u003e Verify subcooling at the service valve targets 11±1°F and run a standing-pressure decay test at 300 PSI for a minimum of 30 minutes before releasing R-32 charge. This prevents nuisance low-pressure lockouts and compressor liquid-slugging callbacks during the first heating season when the system transitions between heat pump and gas furnace modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Expert Validation:\u003c\/strong\u003e Use a digital manifold gauge with R-32 pressure-temperature curves (not R-410A charts — R-32 operates at slightly different saturation pressures). Verify subcooling with a calibrated pipe-clamp thermometer at the liquid service valve. CoolCloud™ app commissioning confirms airflow CFM, changeover settings, and fault history remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Professional Standard:\u003c\/strong\u003e R-32 is classified A2L (mildly flammable); EPA Section 608 certification is required for handling. Follow ASHRAE 15 and local mechanical codes for refrigerant charge limits in enclosed spaces. R-32's GWP of 675 (vs. R-410A's 2088) supports current EPA AIM Act phase-down targets and may support IRA\/25C tax credit eligibility for qualifying high-efficiency configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Efficiency:\u003c\/strong\u003e The GZV9S condenser modulates compressor speed to match real-time load, achieving up to 16.2 SEER2 in this configuration — reducing energy consumption compared to fixed-speed systems while maintaining tighter temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heat Pump Performance:\u003c\/strong\u003e With max heating capacity of 48,000 BTU\/h at 47°F and operational down to -20°F ambient, this system qualifies as Energy Star Cold Climate Certified, extending efficient heat pump operation deeper into the heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant (Low GWP):\u003c\/strong\u003e R-32 carries a Global Warming Potential of 675 — approximately 68% lower than R-410A (GWP 2088). This supports EPA AIM Act compliance and may help qualify for IRA\/25C federal tax credits for eligible high-efficiency equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between heat pump and 96% AFUE gas furnace heating at the configured balance point, optimizing energy cost based on outdoor temperature and local utility rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating ComfortBridge™ Technology:\u003c\/strong\u003e The furnace's integrated ComfortBridge™ platform enables commissioning and diagnostics via Bluetooth through the CoolCloud™ app, reducing setup time and enabling remote fault-code retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e The GZV9S outdoor unit operates at 77 dBA in normal cooling mode (4-ton) and offers a selectable Quiet Mode with up to 3 sound levels (as low as 45 dBA for the GZV9S platform), minimizing neighborhood noise impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Heat Exchanger Construction:\u003c\/strong\u003e The furnace features a heavy-duty aluminized-steel tubular primary heat exchanger with a stainless-steel secondary heat exchanger, backed by a Lifetime Heat Exchanger Limited Warranty (with registration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (AHRI Rated)\u003c\/td\u003e\n\u003ctd\u003e45,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — High Heat (Furnace)\u003c\/td\u003e\n\u003ctd\u003e46,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump @47°F\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity — Heat Pump Low\u003c\/td\u003e\n\u003ctd\u003e29,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutdoor Unit — GZV9SA4810\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Inverter-Driven Swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e37\" x 12⅝\" x 56-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208-230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOCP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level (Cooling\/Heating)\u003c\/td\u003e\n\u003ctd\u003e77 \/ 75 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Range (Cool\/Heat)\u003c\/td\u003e\n\u003ctd\u003e0°F to 115°F \/ -20°F to 70°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEvaporator Coil — CHPEA4830C3\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e30\" x 21\" x 21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGas Furnace — GMVS960805CU\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Fire Input\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages \/ Gas Valve\u003c\/td\u003e\n\u003ctd\u003eSingle-Stage \/ Single-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Rating\u003c\/td\u003e\n\u003ctd\u003eUltra Low NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Width\u003c\/td\u003e\n\u003ctd\u003e[NEEDS VERIFICATION]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Diameter\u003c\/td\u003e\n\u003ctd\u003e2\"-3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cem\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/em\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0056b3; color:#fff;\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (HFC, A2L — Mildly Flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — ~68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608 Certification\u003c\/td\u003e\n\u003ctd\u003eRequired for purchase, handling, and recovery of R-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Classification\u003c\/td\u003e\n\u003ctd\u003eA2L per ASHRAE Standard 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 (outdoor unit and indoor components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Code Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets DOE 2023 federal minimum efficiency standards; verify local Title 24 (CA), SCAQMD, or equivalent requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd\u003eCold Climate (Heat Pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIRA \/ 25C Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003ePotential — Consult IRS Form 5695 and EnergyStar.gov for current SEER2\/HSPF2\/AFUE thresholds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA4810 (Heat Pump Condenser):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWGACHPMTSDC. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty; if the compressor fails within the first 10 years, Daikin will furnish a new equivalent replacement unit (one-time unit replacement). Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHPEA4830C3 (Evaporator Coil):\u003c\/strong\u003e Covered under Goodman coil warranty. \u003cem\u003eWithout registration:\u003c\/em\u003e 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVS960805CU (Gas Furnace):\u003c\/strong\u003e Covered under Goodman warranty Part No. PWCFURNUQNTE. \u003cem\u003eWithout registration:\u003c\/em\u003e 20-Year Heat Exchanger Limited Warranty + 5-Year Parts Limited Warranty. \u003cem\u003eWith registration (within 60 days of installation):\u003c\/em\u003e Lifetime Heat Exchanger Limited Warranty (for as long as original owner resides in the home) + 10-Year Unit Replacement Limited Warranty (if heat exchanger fails in first 10 years, Daikin furnishes replacement unit) + 10-Year Parts Limited Warranty. Registration at www.goodmanmfg.com.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Online registration must be completed within 60 days of installation to receive the extended warranty terms described above. Online registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Complete warranty details are available at www.goodmanmfg.com. Labor, refrigerant, freight, and other service costs are not covered.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657835053376,"sku":"GZV9SA4810-CHPEA4830C3-GMVS960805CU","price":11076.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281","url":"https:\/\/minisplitsystemsdirect.com\/products\/gzv9sa4810-chpea4830c3-gmvs960805cu","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}