{"product_id":"gzv9sa6010-capea6030d3-gmvm971205dn","title":"Goodman 5 Ton 16 SEER2 R-32 Dual Fuel System | GZV9SA6010 + GMVM971205DN + CAPEA6030D3 | Communicating | 24½\" Cabinet Width | Upflow\/Downflow Coil | 120,000 BTU\/h | Upflow\/Horizontal | Modulating Variable-Speed Communicating ECM Natural Gas Furnace","description":"\u003cdiv class=\"product-description\"\u003e\n\u003cp\u003eThis Goodman 5-Ton Dual Fuel System delivers up to 16.0 SEER2 and 8.5 HSPF2 efficiency ratings using low-GWP R-32 refrigerant.\u003c\/p\u003e\n\u003cp\u003eThe dual fuel configuration pairs the GZV9S variable-speed inverter heat pump with a modulating, 97% AFUE gas furnace, providing automatic switchover between electric heat pump and gas heating for optimized comfort and energy savings in all climate zones.\u003c\/p\u003e\n\u003cp\u003eAHRI Certified (Certificate #: 217989293). ENERGY STAR® Cold Climate Certified.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA6010\u003c\/strong\u003e — Goodman GZV9S 5-Ton Variable-Speed Inverter Driven R-32 Side-Discharge Heat Pump Condenser (Up to 21.0 SEER2 \/ 10.0 HSPF2), 208-230V\/1Ph\/60Hz, 230 lbs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM971205DN\u003c\/strong\u003e — Goodman Modulating 97% AFUE 120,000 BTU\/h Gas Furnace, Variable-Speed Communicating ECM, Upflow\/Horizontal, Natural Gas, Communicating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3\u003c\/strong\u003e — Goodman Upflow\/Downflow Cased Evaporator Coil with Internal EEV, 24½\" Cabinet Width, 21\" Depth, All-Aluminum, R-32 Optimized\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background-color:#f7f7f7; border-left:4px solid #d35400; padding:15px; margin:15px 0;\"\u003e\n\u003ch4\u003ePro-Installer Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Friction:\u003c\/strong\u003e On 5-ton dual fuel systems with R-32, the GZV9S outdoor unit requires ⅞\" to 1⅛\" suction line adapters at the service valve. If the furnace is in a tight closet or alcove, verify that the combined coil-on-furnace stack height clears the ceiling by the code-required service access minimum before committing to the installation position.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Prevention:\u003c\/strong\u003e After evacuation, hold a standing vacuum below 500 microns for a minimum of 10 minutes using a Fieldpiece SVG3 or equivalent digital micron gauge. R-32 is less forgiving of moisture contamination than R-410A; residual moisture in the lineset will form acids that degrade compressor windings within 12–18 months, leading to a nuisance compressor fault code well before the warranty period expires.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Validation:\u003c\/strong\u003e Use a digital torque wrench (e.g., Ritchie Yellow Jacket 60648) calibrated to the flare nut specifications in the GZV9S installation manual. Over- or under-torqued flare connections are the #1 root cause of slow R-32 leaks flagged by the unit's onboard pressure transducer diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Standard:\u003c\/strong\u003e R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE Standard 34. Verify local AHJ adoption of 2024 UMC\/IMC codes for A2L allowances. In California SCAQMD jurisdictions, confirm the furnace NOx rating meets the applicable ng\/J standard before the final inspection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Operation:\u003c\/strong\u003e Up to 16.0 SEER2 \/ 8.5 HSPF2 ratings reduce annual energy consumption compared to standard-efficiency systems, potentially qualifying for federal tax credits and utility rebates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP R-32 Refrigerant:\u003c\/strong\u003e R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088)—reducing the system's direct environmental impact while maintaining thermodynamic performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-Speed Inverter Compressor:\u003c\/strong\u003e The GZV9S swing compressor modulates output to match real-time load conditions, minimizing temperature swings and reducing cycling losses compared to single- or two-stage compressors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Flexibility:\u003c\/strong\u003e Automatic switchover between electric heat pump and gas furnace operation based on outdoor temperature provides optimized heating efficiency across a wide ambient range (-20°F to 70°F for heat pump mode).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Quiet-mode feature offers up to 3 selectable sound levels (as low as 45 dBA) on the outdoor unit, suitable for installations near bedrooms, patios, or property-line-adjacent locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR® Cold Climate Certified:\u003c\/strong\u003e Meets or exceeds ENERGY STAR Cold Climate heat pump criteria, validating heating performance in sub-freezing conditions down to -20°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#333; color:#fff;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd\u003e217989293\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eDual Fuel System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e16.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFUE (Furnace)\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (A2L, Low-GWP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Model\u003c\/td\u003e\n\u003ctd\u003eGZV9SA6010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Unit Weight\u003c\/td\u003e\n\u003ctd\u003e230 lbs (Ship: 265 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Electrical\u003c\/td\u003e\n\u003ctd\u003e208-230\/1, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor MCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e34.4A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cooling Capacity (95°F)\u003c\/td\u003e\n\u003ctd\u003e54,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (47°F)\u003c\/td\u003e\n\u003ctd\u003e54,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Heating Capacity (5°F)\u003c\/td\u003e\n\u003ctd\u003e47,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Device\u003c\/td\u003e\n\u003ctd\u003eEEV (Electronic Expansion Valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line \/ Suction Line\u003c\/td\u003e\n\u003ctd\u003e⅜\" \/ 1⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Refrigerant Charge\u003c\/td\u003e\n\u003ctd\u003e162 oz. (for 15 ft of ⅜\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Model\u003c\/td\u003e\n\u003ctd\u003eGMVM971205DN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Input\u003c\/td\u003e\n\u003ctd\u003e120,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace AFUE\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Stage \/ Motor\u003c\/td\u003e\n\u003ctd\u003eModulating \/ Variable-Speed Communicating ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx \/ Gas Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Heating Output (M1)\u003c\/td\u003e\n\u003ctd\u003e53,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator Coil Model\u003c\/td\u003e\n\u003ctd\u003eCAPEA6030D3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configuration\u003c\/td\u003e\n\u003ctd\u003eUpflow\/Downflow (Cased)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Cabinet Dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24½\" x 21\" x 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Ship Weight\u003c\/td\u003e\n\u003ctd\u003e78 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eCommunicating (ComfortNet \/ ComfortBridge compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"font-style:italic; font-size:0.9em;\"\u003eNote: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#333; color:#fff;\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR-32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant GWP\u003c\/td\u003e\n\u003ctd\u003e675 (vs. R-410A at 2,088 — 68% reduction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASHRAE Safety Classification\u003c\/td\u003e\n\u003ctd\u003eA2L (Lower Flammability, Lower Toxicity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Section 608\u003c\/td\u003e\n\u003ctd\u003eUniversal Certification required for refrigerant handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eUL 60335-2-40 compliant; ASHRAE Standard 15 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd\u003eYes (Certificate #217989293)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENERGY STAR®\u003c\/td\u003e\n\u003ctd\u003eCold Climate Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETL Listed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegional Compliance\u003c\/td\u003e\n\u003ctd\u003eAll U.S. regions; verify local AHJ A2L refrigerant code adoption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Tax Credit Eligibility\u003c\/td\u003e\n\u003ctd\u003eMay qualify under 25C\/25D residential energy efficiency tax credits (consult a tax professional for current eligibility requirements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace NOx Emissions\u003c\/td\u003e\n\u003ctd\u003eStandard emissions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty \u0026amp; Registration\u003c\/h3\u003e\n\u003cp\u003eEach component in this system carries its own manufacturer warranty. Online registration at \u003ca href=\"https:\/\/www.goodmanmfg.com\"\u003ewww.goodmanmfg.com\u003c\/a\u003e must be completed within 60 days of the installation date to receive the full registered warranty coverage. Below are the warranty terms per component:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGZV9SA6010 (Heat Pump Condenser):\u003c\/strong\u003e 5-Year Initial Term Parts Limited Warranty (unregistered). When registered within 60 days: 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty (if compressor fails during first 10 years, Daikin will furnish a new equivalent unit, one time). One-time Compressor Replacement coverage available for years 11–99 through an ASURE Extend Service Plan. Registration is not required in California, Florida, or Québec. Warranty coverage duration may differ in Texas and Florida.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMVM971205DN (Gas Furnace):\u003c\/strong\u003e When registered within 60 days: Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty. 99-Year Heat Exchanger Limited Warranty may apply per model. Unregistered: 5-Year Parts Limited Warranty. Registration is not required in California, Florida, or Québec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAPEA6030D3 (Evaporator Coil):\u003c\/strong\u003e When registered within 60 days: 10-Year Parts Limited Warranty. Unregistered: 5-Year Parts Limited Warranty. Registration is not required in California, Florida, or Québec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eImportant: Warranty applies to owner-occupied residences. Different warranty terms apply to non-owner-occupied residences and commercial installations. Warranty does not cover labor, refrigerant, freight, or consequential damages. See official warranty documents for complete terms, limitations, and exclusions.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":51657832530240,"sku":"GZV9SA6010-CAPEA6030D3-GMVM971205DN","price":11611.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/yjtyjgjghjgjgyjjd_1.jpg?v=1777340281","url":"https:\/\/minisplitsystemsdirect.com\/products\/gzv9sa6010-capea6030d3-gmvm971205dn","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}