{"product_id":"verdant-vx3-wireless-energy-management-thermostat-kit-with-built-in-occupancy-detection-rib-relay-included-vx3-tw-w-lit","title":"Verdant VX3 Wireless Energy Management Thermostat Kit with built-in Occupancy Detection (RIB Relay Included) - VX3-TW-W-LIT","description":"\u003ch3\u003e\u003cstrong\u003eVerdant VX3 Wireless Energy Management Thermostat Kit with built-in Occupancy Detection (RIB Relay Included) - VX3-TW-W-LIT\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Verdant VX3-TW-W-LIT thermostat delivers unprecedented energy savings without compromising guest comfort.\u003c\/p\u003e\n\u003cp\u003eNew energy efficient building codes have raised the energy performance standards required of commercial buildings.\u003c\/p\u003e\n\u003cp\u003eCalifornia’s Title 24 (Part 6) building code as well as other state building codes founded upon IECC 2015 or 2018 energy efficiency codes have now mandated occupancy-based control of heating and air-conditioning, lighting, outside air dampers, and\/or receptacles.\u003c\/p\u003e\n\u003cp\u003eThe Verdant VX3-TW-W-LIT thermostat reduces HVAC runtime by dynamically setting back temperature in empty rooms, without disturbing the comfort of occupants.\u003c\/p\u003e\n\u003cp\u003eThe thermostat can also power a lighting circuit by using an external relay that receives the thermostat’s occupied\/unoccupied signal.\u003c\/p\u003e\n\u003cp\u003eThe occupancy-based thermostat solution includes a dry contact switch on port J9 of the HVAC controller (see diagram in the photos) that closes when occupancy is detected by the onboard sensor or any other remote wireless occupancy sensor.\u003c\/p\u003e\n\u003cp\u003eWhen occupancy is detected, the dry contact J9 (activated by positioning a jumper in port J10) will close and allow a 24VAC transformer to energize the coil of an external relay R1 installed to control the lighting circuit.\u003c\/p\u003e\n\u003cp\u003eIn the absence of occupancy detection, after a configurable amount of time, the J9 switch will open and interrupt the flow of power to the lighting relay.\u003c\/p\u003e\n\u003cp\u003eThe Verdant thermostat and Verdant HVAC Controller communicate wirelessly for a simple and effortless installation. The Verdant HVAC Controller connects to the HVAC unit using a standard wire harness.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eRequires a network access license for each thermostat (Part Number: XMF) and one “Online Connection Kit” (Part Number: ZX-OL-U). Additional fees apply.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eIn jurisdictions where building code mandate any of the undermentioned measures, additional software licenses (Part Number: XMF) and one (1) Online Connection Kit are required. Additional fees apply.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn the case of a mini split or VRF unit, please contact Mini Split Systems Direct for the applicable part number.\u003c\/p\u003e\n\u003cp\u003eVerdant’s combined solution offers building owners a cost effective energy management system that can be deployed with minimal accessories, and little to no extra labor, making it simple to install.\u003c\/p\u003e\n\u003cp\u003eThe VX3-TW-W-LIT thermostat facilitates building-code compliance by addressing the following requirements:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIECC 2015\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1. C405.2.4.3 Specific application controls for sleeping units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIECC 2018\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1. C.403.7.6 Automatic Control of HVAC system serving guestrooms integrally.\u003c\/p\u003e\n\u003cp\u003e2. C405.2.4.2 Specific application controls for sleeping units\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTitle 24 Part 6\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1. Section 130.1(c)8 Shut-off controls for Hotel\/Motel guestrooms.\u003c\/p\u003e\n\u003cp\u003e2. Section 120.2(e) Shut-off and Reset Controls for Space-conditioning Systems\u003c\/p\u003e\n\u003cp\u003e3. Section 130.5(d) Circuit Controls for 120V Receptacles and Controlled Receptacles.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEasy to use Thermostat\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eUnparalleled Energy Savings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eAux output for occupancy-based control of external devices (i.e. lights, receptacles, outside air dampers)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eFacilitates compliance with energy efficiency codes such as Title 24, and IECC 2015\/2018.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eOnline management capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical HVAC Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePTAC with Electric Heat\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eFCU 2-Pipe, 2 Fan, with Electric Heat\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eHeat Pump, 2 Fan, with Electric Heat\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eVRF Systems (Part # VX3-RSW-W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003ePTHP with Electric Heat\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eFCU 4-Pipe, 3 Fan\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eWSHP, 2 Fan, with Electric Heat\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMini Splits (Part # VX3-RSW-W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eThermostat Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eVerdant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eVX3-TW-W-LIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eCase Dimensions (Imperial)\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e3.00” x 4.73” x 1.32”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eCase Dimensions (Metric)\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e76mm x 120mm x 34mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eScreen Dimensions (Imperial)\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e1.88” x 0.94”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eScreen Dimensions (Metric)\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e48mm x 24mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e2 “AA” Cell Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eOccupancy Sensor Beam Width\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e±47° (94°)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eWireless Frequency\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e900MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eFCC ID\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eXEYZXWU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eIC\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e8410A-ZXWU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003e\u003cstrong\u003eHVAC Controller Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eVerdant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eVX3-TW-W-LIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eCase Dimensions (Imperial)\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e4.84” x 2.76” x 1.02”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eCase Dimensions (Metric)\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e123mm x 70mm x 26mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eScreen Dimensions (Imperial)\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eScreen Dimensions (Metric)\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e24VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eControl Outputs\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eFan High (GH)\u003c\/li\u003e\n\u003cli\u003eFan Low (GL)\u003c\/li\u003e\n\u003cli\u003eCompressor (Y)\u003c\/li\u003e\n\u003cli\u003eHeat Pump (OB)\u003c\/li\u003e\n\u003cli\u003eHeat (W)\u003c\/li\u003e\n\u003cli\u003eOccupancy Out (Aux)\u003c\/li\u003e\n\u003cli\u003eAux 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eOccupancy Sensor Beam Width\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eWireless Frequency\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e900MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eFCC ID\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eXEY-ZX-LV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eIC\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e8410A-ZXLV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003e\u003cstrong\u003eOccupancy Sensor\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eVerdant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eVX3-TW-W-LIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eCase Dimensions (Imperial)\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e1.82 x 2.4 x 0.74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eCase Dimensions (Metric)\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e46mm x 61mm x 19mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eScreen Dimensions (Imperial)\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eScreen Dimensions (Metric)\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e3V - (2 AAA Batteries - Not Supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eOccupancy Sensor Beam Width\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e±47° (94°)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eWireless Frequency\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e900MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eFCC ID\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003eXEYZ9RF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.701%;\"\u003eIC\u003c\/td\u003e\n\u003ctd style=\"width: 58.299%;\"\u003e8410A-Z9RF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Information and Guides:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/VX3-TW-W-LIT.pdf?v=1700380478\"\u003eSpecifications Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Verdant-Master-Brochure-Hospitality_Sept-2021-4.pdf?v=1700372183\"\u003eVerdant Thermostat Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Hyatt_Place_San_Jose_CA_-_Verdant_Hospitality_Case_Study.pdf?v=1700372268\"\u003eHyatt Place - Verdant Hospitality Case Study\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Great_Wolf_Lodge_Scottsdale_-_Verdant_Hospitality_Case_Study.pdf?v=1700372233\"\u003eGreat Wold Lodge - Verdant Hospitality Case Study\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Verdant","offers":[{"title":"White","offer_id":47354833928512,"sku":"VX3-TW-W-LIT","price":389.0,"currency_code":"USD","in_stock":true},{"title":"Black","offer_id":47354834846016,"sku":"VX3-TB-B-LIT","price":389.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5924\/9984\/files\/Verdant-VX3-Wireless-Energy-Management-Thermostat-Kit-with-built-in-Occupancy-Detection-RIB-Relay-Included-VX3-TW-W-LIT-VX3-TW-W-LIT-VX3-TB-B-LIT-Mini-Split-Systems-Direct-40688592093504.jpg?v=1768993673","url":"https:\/\/minisplitsystemsdirect.com\/products\/verdant-vx3-wireless-energy-management-thermostat-kit-with-built-in-occupancy-detection-rib-relay-included-vx3-tw-w-lit","provider":"Mini Split Systems Direct","version":"1.0","type":"link"}