Daikin Aurora Ductless Mini Split 21 SEER2 Heat Pump & AC System

SKU: 2MXTH18AVJU9
Your Price:
$2,981.00 $4,024.35
You Save: $1,043.35 26%
  • FLASH SALE GOING ON NOW! Save An Extra 15% OFF with Code: FLASH15
  • NO SALES TAX OUTSIDE ARIZONA CALIFORNIA FLORIDA MICHIGAN NEW YORK NORTH CAROLINA PENNSYLVANIA TENNESSEE VIRGINIA
  • EASY RETURNS: 30 Days Money Back Guaranteed
  • FREE SHIPPING: Ships in 2 - 3 Business Days
  • FAST DELIVERY: Arrives in 3 - 7 Days
  • HASSLE FREE DELIVERY: Free Liftgate Delivery + Freight Insurance
  • NEED HELP?: Call 1-800-315-4345
  • AUTHORIZED DEALER: Best Products and Equipment from a Reliable and Knowledgeable Source
Checkout Secure

Quantity Remaining:

Only 11 Left in Stock.
Order in the next to get it by

Get Extra 15% Off With Code: FLASH15 - Flash Sale Ends:

Days
Hours
Minutes
Seconds

Daikin AURORA 18,000 BTU (Up to 24,000 BTU) 21 SEER2 Ductless Mini Split Heat Pump and Air Conditioning Inverter Multi-Zone Condenser with Drain Pan Heater - 2MXTH18AVJU9

Daikin's Multi-Zone Systems are ideal for multi-room applications desiring individual room comfort in a space-saving design, with the ability to connect two indoor units to a single outdoor unit. Systems offer energy efficiency levels up to 21 SEER2 and 10 HSPF2 for enhanced home comfort and energy savings. Daikin AURORA Multi-Zone systems offer enhanced capacity in cold ambient conditions. Suitable for both new build and renovation projects, Daikin Multi-Zone Systems are the smart, reliable solution for your home.

Features:

  • Includes drain pan heater
  • Up to 24,000 BTU's - See Combination Capacity Chart here
  • Pre-Charged for 98.4 ft of line set length
  • World-renowned Daikin Inverter Variable Speed compressor technology
  • Designed to deliver enhanced capacity in cold ambient conditions
  • Up to 114% rated heating capacity at 5°F / -15°C and operate efficiently as low as -13°F ambient temperature (See full operating temperature details here)
  • Energy Efficient - UP to 21 SEER2 / 10 HSPF2 / 12 EER2 for ultra-efficient cooling and heating operation and reduced operating costs compared to conventional lower-efficiency systems
  • 2 Zone enhanced Capacity Multi-Zone
  • R-32 Refrigerant Type

Specifications:

Brand
Daikin
Model
2MXTH18AVJU9
Warranty
BTU
18,000 BTU (Up to 24,000 BTU) - See Combination Capacity Chart here
Power Supply
  • Phase: 1
  • Hz, V: 60 Hz, 208 - 230 V
  • MCA: 19.6
  • MOP: 20.0
COP@5°F
W/W: 1.8
EER2 (Btu/W·h)

12.0

SEER2
21.0
HSPF2
10.0
Casing Color
Ivory White
Compressor
  • Type: Hermetically Sealed Swing Type
  • Model: 2Y260BPAX1A
  • Motor Output (W): 2,400 W
Refrigerant Oil
  • Model: FW68DA
  • Charge fl oz (L): 30.4 (0.9)
Refrigerant
  • Type: R-32
  • Charge lbs (kg): 4.9 (2.2)
  • Pre-Charge: Pre-Charged for 98.4 ft of line set length
Airflow Rates
  • Cooling: 2,112 (cfm) / 59.8 (m³/min)
  • Heating: 2,140 (cfm)  / 60.6 (m³/min)
Fan
  • Type: Propeller
  • Motor Output: 150 W
  • Running Current (Cooling / Heating): 0.31 A / 0.33 A
  • Power Consumption (Cooling / Heating): 65.4 W / 67.7 W
Starting Current
17 A
Dimensions (H × W × D)
29-1/2 × 34-1/4 × 12-5/8 inches (750 × 870 × 320 mm)
Packaged Dimensions (H × W × D)
32-1/16 × 40-5/16 × 16 inches (814 × 1,024 × 406 mm)
Weight (Mass)
140 lbs (64 kg)
Gross Weight (Gross Mass)
148 lbs (67 kg)
Sound Pressure Level
  • Cooling: 52 dB(A) 
  • Heating: 54 dB(A) 
Piping
Connection (inches)
  • Liquid: 1/4 x 2
  • Gas: 3/8 x 1, 1/2 x 1
  • Drain: 5/8 inches
Heat Insulation
Both Liquid and Gas Pipes
No. of Wiring Connections
3 for Power Supply, 4 for Interunit Wiring (Including Ground Wiring)
Max. Interunit Piping Length
  • 164 ft (50 mm) (for Total of Each Room)
  • 82 ft (25mm) (for One Room)
Amount of Additional Charge oz/ft(g/m)
0.22 (20) (98-3/8 ft (30 m) or more)
Max. Installation Height Difference
  • 49-1/4 ft (15 mm) (Between Indoor Unit and Outdoor Unit)
  • 24-5/8 ft (7.5 mm) (Between Indoor Units)
Conditions Based on Cooling
  • Indoor ; 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB)
  • Outdoor ; 95°FDB (35°CDB) / 75°FWB (24°CWB)
  • Piping length: 25 ft (7.5 m)
Conditions Based on Heating
  • Indoor ; 70°FDB (21°CDB) / 60°FWB (15.6°CWB)
  • Outdoor ; 47°FDB (8.3°CDB) / 43°FWB (6°CWB)
  • Piping length: 25 ft (7.5 m)