GPCH33031 is a 2.5-ton Goodman GPCH3 R-32 packaged air conditioner built for ducted cooling. Horizontal discharge (packaged AC-only).
A packaged air conditioner combines the compressor, condenser coil, evaporator coil, and blower into a single outdoor cabinet—often installed at ground level or on a rooftop—so you don’t need a separate indoor air handler cabinet inside the building.
At-a-glance (this exact model)
| Nominal size | 2.5 ton (model code 30) |
|---|---|
| Rated cooling capacity | 27,000 BTU/h total |
| Sensible capacity (temperature drop portion) | 20,200 BTU/h |
| Efficiency ratings | 13.4 SEER2 / 10.6 EER2 — SEER2 reflects seasonal cooling efficiency and EER2 reflects efficiency at peak conditions; higher numbers mean more cooling per unit of electricity. |
| Refrigerant | R-32 (charge: 36 oz) |
| Indoor airflow (nominal) | 910 CFM via 5-speed ECM blower |
| Sound level | 74 dB (per spec sheet) |
Sizing & selection guidance
“Ton” is a nominal sizing label (1 ton ≈ 12,000 BTU/h). Proper sizing still requires a load calculation (for example, ACCA Manual J/S or a commercial heat gain analysis). Oversized equipment can short-cycle and under-dehumidify; undersized equipment may struggle on design days.
What the model number tells you
Goodman packaged unit model numbers encode the nominal size and electrical configuration.
- 30 = 2.5 ton nominal size
- 3 = 13.4 SEER2 efficiency tier in this series
- 1 = 208/230 V, 1 phase, 60 Hz
Core components & performance details
| Compressor | Scroll compressor, single-stage (RLA 12.8, LRA 76.0) |
|---|---|
| Condenser coil | Copper tube / aluminum fin |
| Evaporator coil | All-aluminum |
| Metering device | Piston |
| Condensate drain connection | 3/4" NPT |
| Indoor blower motor | ECM, 1/2 HP, 3.8 FLA, 5 speeds |
| Outdoor fan motor | 1/6 HP, 0.95 FLA, 22" blade |
This unit uses R-32 refrigerant (ASHRAE safety class A2L: lower toxicity with mild flammability). Installation and service should follow current local code requirements for A2L refrigerants and be performed by qualified technicians.
Airflow, ductwork & installation planning
| Duct openings (supply / return) | 14x14 / 14x22 (W×H, inches) |
|---|---|
| Airflow configuration | Horizontal discharge (packaged AC-only) |
For jobs that require electric heat, this series supports field-installed electric heat kits (5–20 kW options are listed for GPCH3). Heat kit selection should match local design loads and available electrical capacity.
Electrical requirements (verify before installation)
| Power supply | 208/230 V, 1 phase, 60 Hz |
|---|---|
| Minimum Circuit Ampacity (MCA) | 20.8 A |
| Maximum Overcurrent Protection (MOCP) | 30 A (use time-delay fuses or HACR breakers per spec sheet) |
Always verify final electrical data on the unit’s nameplate and size wiring per the National Electrical Code and local codes. Long wire runs may require larger conductor sizes.
Dimensions, clearances & weight
| Cabinet footprint (W×D) | 66" × 34" |
|---|---|
| Cabinet height references (A / B) | 27.5" / 30" (chassis size: Small) |
| Weight (operating / shipping) | 320 / 330 lb |
Construction, durability & certifications
Standard features
- 13.4 SEER2 efficiency (2–5 ton sizes)
- Energy-efficient scroll compressor (see model-specific compressor details below)
- Multi-speed ECM indoor blower motor (5 speeds)
- Quiet horizontal discharge airflow
- Copper tube / aluminum fin condenser coil
- All-aluminum evaporator coil
- Totally enclosed, permanently lubricated condenser fan motor
- Fully charged system (refrigerant charge listed by model)
- Field-installed electric heat kit option (5–20 kW options listed for this series)
- AHRI Certified; UL Listed
- ENERGY STAR® certified: No (per manufacturer product page)
- ComfortBridge™ compatibility: No (per manufacturer product page)
Cabinet features
- Heavy-gauge galvanized-steel cabinet with architectural gray powder-paint finish
- Louvered condenser coil protection
- Aluminum foil-facing internal insulation reinforced with fiberglass scrim
- Fully insulated blower compartment with convenient access panels
- Meets cabinet air leakage requirements when tested to ASHRAE Standard 193
- One footprint across tonnages
- When properly anchored, meets 2023 Florida Building Code unit integrity requirements for hurricane-type winds (anchor bracket kits available)
Certifications: AHRI Certified and UL Listed (per manufacturer specification sheet). AHRI certification helps verify published performance ratings.
Common accessories for this chassis size
Accessory availability can depend on chassis size (Small vs. Medium/Large) and the installation configuration.
- Downflow Economizer (use with PCCP roof curb): DDNECNJPCHHA
- Downflow Plenum Kit (use with PCCP roof curb): PCP101-103
- Downflow Plenum Kit (R-8) (use with PCCP roof curb): PCP101-103 R8
- Elbow Flashing w/R-8 Liner: PCEF101-103
- Economizer Wiring Harness: 0259G00213
- External Horizontal Filter Rack: DPHFRA
- Horizontal Economizer: DHZECNJPGCHM
- Inline Fuse Kit: INFKPKG01
Plus 8 more listed accessories for this chassis size in the manufacturer’s spec sheet.
What you’ll typically need in addition to the unit
- Professional installation (set/anchor curb or pad, connect supply/return ductwork, connect condensate drain, connect power and controls).
- A compatible thermostat/control (often supplied separately).
- An outdoor service disconnect and properly sized branch circuit protection (per MOCP).
- If installed on a roof: the correct roof curb and any downflow/transition pieces required for your duct layout.
- Filters and filter rack solutions as required by your installation (manufacturer lists optional filter rack accessories).
Warranty
10-Year Parts Limited Warranty available with online registration completed within 60 days of installation (registration not required in California, Florida, or Québec; other limitations and exceptions may apply).
Before you order (quick checklist)
- Confirm you need an AC-only packaged unit (not a heat pump).
- Confirm nominal size: 2.5 ton and rated capacity 27,000 BTU/h.
- Confirm installation orientation/duct configuration: Horizontal discharge (packaged AC-only).
- Confirm your electrical service supports the unit’s MCA and MOCP.
- If adding an economizer or downflow setup, confirm the required curb/duct cover/relay kits and chassis-specific part numbers.
- Confirm local requirements for installing and servicing A2L refrigerants (R-32).