Goodman GPCM32431 Packaged Air Conditioner (2.0 Ton, 13.4 SEER2, R-32, Multi-position (horizontal or downflow), 208/230V 1-Ph)

SKU: GPCM32431
Your Price:
$0.00
Checkout Secure

Quantity Remaining:

80 of 100 Sold
Order in the next to get it by

GPCM32431 is a 2.0-ton Goodman GPCM3 R-32 packaged air conditioner built for ducted cooling. Convertible airflow: horizontal or downflow (packaged AC-only).

A packaged air conditioner combines the compressor, condenser coil, evaporator coil, and blower into a single outdoor cabinet—often installed at ground level or on a rooftop—so you don’t need a separate indoor air handler cabinet inside the building.

At-a-glance (this exact model)

Nominal size 2.0 ton (model code 24)
Rated cooling capacity 24,000 BTU/h total
Sensible capacity (temperature drop portion) 18,480 BTU/h
Efficiency ratings 13.4 SEER2 / 10.6 EER2 — SEER2 reflects seasonal cooling efficiency and EER2 reflects efficiency at peak conditions; higher numbers mean more cooling per unit of electricity.
Refrigerant R-32 (charge: 63 oz)
Indoor airflow (nominal) 800 CFM via 5-speed ECM blower
Sound level 74 dB (per spec sheet)

Sizing & selection guidance

“Ton” is a nominal sizing label (1 ton ≈ 12,000 BTU/h). Proper sizing still requires a load calculation (for example, ACCA Manual J/S or a commercial heat gain analysis). Oversized equipment can short-cycle and under-dehumidify; undersized equipment may struggle on design days.

What the model number tells you

Goodman packaged unit model numbers encode the nominal size and electrical configuration.

  • 24 = 2 ton nominal size
  • 3 = 13.4 SEER2 efficiency tier in this series
  • 1 = 208/230 V, 1 phase, 60 Hz

Core components & performance details

Compressor Scroll compressor, single-stage (RLA 10.6, LRA 56.5)
Condenser coil Copper tube / aluminum fin
Evaporator coil All-aluminum
Metering device Piston
Condensate drain connection 3/4" NPT
Indoor blower motor ECM, 1/2 HP, 3.8 FLA, 5 speeds
Outdoor fan motor 1/6 HP, 0.95 FLA, 22" blade

This unit uses R-32 refrigerant (ASHRAE safety class A2L: lower toxicity with mild flammability). Installation and service should follow current local code requirements for A2L refrigerants and be performed by qualified technicians.

Airflow, ductwork & installation planning

Duct openings (supply / return) 16x16 / 16x16 (W×H, inches)
Airflow configuration Convertible airflow: horizontal or downflow (packaged AC-only)

An electric heat kit is available as a field-installed option if you need supplemental/backup heat. Heat kit selection should match local design loads and available electrical capacity.

Downflow note: Downflow installs have extra requirements. Per the spec sheet: a Horizontal Duct Cover is required for all downflow installations, and either a Downflow Economizer or a Downflow Conversion Kit is mandatory for all downflow installations.

Electrical requirements (verify before installation)

Power supply 208/230 V, 1 phase, 60 Hz
Minimum Circuit Ampacity (MCA) 18.0 A
Maximum Overcurrent Protection (MOCP) 25 A (use time-delay fuses or HACR breakers per spec sheet)

Always verify final electrical data on the unit’s nameplate and size wiring per the National Electrical Code and local codes. Long wire runs may require larger conductor sizes.

Dimensions, clearances & weight

Cabinet footprint (W×D) 47" × 51"
Cabinet height references (A / B) 32" / 34.75" (chassis size: Medium)
Weight (operating / shipping) 310 / 320 lb

Construction, durability & certifications

Standard features

  • 13.4 SEER2 efficiency (2–5 ton sizes)
  • Energy-efficient scroll compressor (single-stage per model specs)
  • Multi-speed ECM indoor blower motor (5 speeds)
  • Convertible airflow for horizontal or downflow applications
  • Copper tube / aluminum fin condenser coil
  • All-aluminum evaporator coil
  • Field-installed electric heat kit option (heat kit size varies by application)
  • AHRI Certified; UL Listed
  • ENERGY STAR® certified: No (per manufacturer product page)
  • ComfortBridge™ compatibility: No (per manufacturer product page)

Cabinet features

  • Heavy-gauge galvanized-steel cabinet with architectural gray powder-paint finish
  • Aluminum foil-facing internal insulation reinforced with fiberglass scrim
  • Fully insulated blower compartment with convenient access panels
  • Meets cabinet air leakage requirements when tested to ASHRAE Standard 193
  • Louvered condenser coil protection
  • One footprint across tonnages
  • When properly anchored, meets 2023 Florida Building Code unit integrity requirements for hurricane-type winds (anchor bracket kits available)

Certifications: AHRI Certified and UL Listed (per manufacturer specification sheet). AHRI certification helps verify published performance ratings.

Common accessories for this chassis size

Downflow installs have extra requirements. Per the spec sheet: a Horizontal Duct Cover is required for all downflow installations, and either a Downflow Economizer or a Downflow Conversion Kit is mandatory for all downflow installations.

  • Concentric Kit: CDK36
  • Downflow Economizer (mandatory for some downflow installs): GPJMED102
  • Downflow Internal Filter Rack: DDNIFRPCHMM
  • Downflow Manual Damper: PGMDD101/102
  • Downflow Motorized Damper: PGMDMD101/102
  • Downflow Square to Round: SQRPG101/102
  • Downflow Conversion Kit (mandatory for some downflow installs): DWNFLWCONV
  • Economizer Wiring Harness (required for economizer accessories): 0259L00411
  • External Horizontal Filter Rack: DPHFRA
  • Horizontal Duct Cover (required for all downflow installs): 20464501PDGK

Plus 7 more listed accessories for this chassis size in the manufacturer’s spec sheet.

What you’ll typically need in addition to the unit

  • Professional installation (set/anchor curb or pad, connect supply/return ductwork, connect condensate drain, connect power and controls).
  • A compatible thermostat/control (often supplied separately).
  • An outdoor service disconnect and properly sized branch circuit protection (per MOCP).
  • If installed on a roof: the correct roof curb and any downflow/transition pieces required for your duct layout.
  • Filters and filter rack solutions as required by your installation (manufacturer lists optional filter rack accessories).

Warranty

10-Year Parts Limited Warranty available with online registration completed within 60 days of installation (registration not required in California, Florida, or Québec; other limitations and exceptions may apply).

Before you order (quick checklist)

  • Confirm you need an AC-only packaged unit (not a heat pump).
  • Confirm nominal size: 2.0 ton and rated capacity 24,000 BTU/h.
  • Confirm installation orientation/duct configuration: Convertible airflow: horizontal or downflow (packaged AC-only).
  • Confirm your electrical service supports the unit’s MCA and MOCP.
  • If adding an economizer or downflow setup, confirm the required curb/duct cover/relay kits and chassis-specific part numbers.
  • Confirm local requirements for installing and servicing A2L refrigerants (R-32).