This Goodman 2 Ton Heat Pump Condenser and Evaporator Coil System pairs the GZV6SA2410 variable-speed inverter-driven R-32 heat pump with the CAPEA3022B3 cased evaporator coil featuring an electronic expansion valve (EEV). The system is AHRI certified (Certificate #217577960) and rated at 15.2 SEER2, 8.0 HSPF2, and 10.0 EER2.

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

System Components

  • Outdoor Heat Pump Condenser: Goodman GZV6SA2410 — 2 Ton, Variable-Speed Inverter-Driven, R-32, Side-Discharge Heat Pump. Rated for 23,200 BTU/h max cooling and 23,200 BTU/h max heating at 47°F. Cold Climate ENERGY STAR® Most Efficient certified.
  • Evaporator Coil: Goodman CAPEA3022B3 — Upflow/Downflow, Cased, All-Aluminum Coil with factory-installed Electronic Expansion Valve (EEV). 17-1/2" cabinet width, 21" depth. Optimized for R-32 refrigerant.

Pro-Installer Tip

Technical Friction: The GZV6SA2410 uses R-32 refrigerant with an EEV-equipped indoor coil. The CAPEA3022B3 coil at 21" depth fits standard attic hatches, but confirm vertical clearance above the coil for the suction line bend radius — R-32 suction pressures run higher than R-410A at the same conditions, so use ACR-rated copper sized per the spec sheet (3/4" OD suction for this 2-ton unit).

Long-Term Prevention: After brazing with nitrogen purge, evacuate to 350 microns and hold. The EEV in the CAPEA/CHPEA coil communicates with the outdoor unit's inverter board — a moisture-contaminated system will cause the EEV stepper motor to hunt erratically within 6-12 months, generating nuisance fault codes.

Expert Validation: Use a digital micron gauge to verify deep vacuum. After system startup, confirm the outdoor unit's seven-segment LED shows no active fault codes and verify subcooling reads 12±1°F at the service valve with an R-32 calibrated digital manifold.

Professional Standard: R-32 is classified A2L (mildly flammable) under ASHRAE 34. EPA Section 608 certification is required. Verify local code adoption of UL 60335-2-40. The system ships with 74 oz of R-32 factory charge sized for 15 ft of 3/8" liquid line — adjust per the installation instructions for actual lineset length.

Key System Benefits

  • Verified Efficiency: AHRI-certified 15.2 SEER2 / 8.0 HSPF2 / 10.0 EER2 ratings ensure consistent, tested performance in both cooling and heating modes.
  • Variable-Speed Inverter Compressor: The swing compressor modulates output to match the actual load, reducing temperature swings and energy consumption compared to fixed-speed systems.
  • Low-GWP R-32 Refrigerant: R-32 has a Global Warming Potential (GWP) of 675, which is approximately 68% lower than R-410A (GWP 2,088), aligning with EPA AIM Act requirements and future refrigerant regulations.
  • Quiet Operation: The outdoor unit features a high-density compressor sound blanket, digitally commutated fan motor, and a selectable quiet mode that reduces sound output to as low as 45 dBA — suitable for installations near bedrooms or patios.
  • All-Aluminum Evaporator Coil: The indoor coil uses an all-aluminum construction with an R-32 sensor designed for the life span of the coil, paired with a factory-installed EEV for precise refrigerant metering.

Technical Specifications

Specification Value
AHRI Certificate # 217577960
System Type Heat Pump Condenser and Evaporator Coil System
Nominal Capacity 2 Ton (24,000 BTU/h)
SEER2 15.2
EER2 10.0
HSPF2 8.0
Cooling Capacity (AHRI Rated) 23,000 BTU/h
Heating Capacity @ 47°F (AHRI Rated) 23,000 BTU/h
Heating Capacity @ 5°F 14,400 BTU/h
Refrigerant R-32
Refrigerant Charge 74 oz
Expansion Device Electronic Expansion Valve (EEV)
Compressor Type Variable-Speed Swing
Outdoor Unit Dimensions (W×D×H) 36-5/8" × 13-3/4" × 27-3/8"
Outdoor Unit Weight 122 lbs (137 lbs shipping)
Electrical (Outdoor) 208-230V / 1 Phase / 60 Hz
MCA / Max Overcurrent 16.8A / 20A
Liquid Line / Suction Line 3/8" / 3/4"
Coil Dimensions (W×D×H) 17-1/2" × 21" × 22"
Coil Shipping Weight 48 lbs
Coil Configuration Upflow/Downflow, Cased
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.

Compliance & Environmental Data

Category Details
Refrigerant Type R-32 (Difluoromethane)
Global Warming Potential (GWP) 675 (approximately 68% lower than R-410A at 2,088 GWP)
ASHRAE Safety Classification A2L (Lower Flammability)
EPA Section 608 Technician certification required for refrigerant handling, recovery, and disposal
Regional Compliance Meets EPA AIM Act phasedown requirements; compliant with DOE 2023 efficiency standards (SEER2/HSPF2 metrics)
AHRI Certification Certificate #217577960 — independently tested and verified
ENERGY STAR® Status Meets ENERGY STAR® criteria when properly matched with qualifying indoor components
Tax Credit Eligibility This configuration may not independently meet IRA tax credit efficiency thresholds. Verify current requirements at energystar.gov or consult a tax professional.

Warranty & Registration

Each component in this system carries its own manufacturer warranty. Online registration at www.goodmanmfg.com must be completed within 60 days of installation to activate the full registered warranty coverage. Registration is not required in California, Florida, or Québec.

  • Outdoor Heat Pump (GZV6SA2410): Unregistered: 5-year parts limited warranty from the installation date. Registered (within 60 days): 10-year parts limited warranty; if the compressor fails within 10 years, Daikin will furnish a new equivalent unit to replace the entire outdoor unit (one-time replacement). Warranty applies to owner-occupied residences only.
  • Evaporator Coil (CAPEA3022B3): Unregistered: 5-year parts limited warranty from the installation date. Registered (within 60 days): 10-year parts limited warranty. Warranty applies to owner-occupied residences only.

Labor, refrigerant, freight, and other service costs are not covered under these warranties. Refer to each component's full warranty document for complete terms, conditions, limitations, and exclusions.