Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Free Shipping | Call for Best Pricing: 1-800-315-4345

Got a Question? Call Us

Phone Icon 1-800-315-4345

Monday-Saturday 9am-6pm EST

Goodman 2 Ton 18.0 SEER2 R-32 Dual Fuel System | GZV6SA2410 + GDVM970803BN + CAPEA2418B3 | 80,000 BTU Downflow/Horizontal Modulating Variable-Speed ECM 97% AFUE Furnace | 17½" Wide Upflow/Downflow Coil

SKU: GZV6SA2410-GDVM970803BN-CAPEA2418B3
Your Price:
$6,963.00 $9,330.00
You Save: $2,367.00 26%
Checkout Secure

Quantity Remaining:

227 of 300 Sold
Order in the next to get it by

This AHRI-certified Dual Fuel System pairs the Goodman GZV6SA2410 2-ton, 18.0 SEER2, 8.5 HSPF2 variable-speed inverter-driven R-32 heat pump with the GDVM970803BN 97% AFUE modulating gas furnace (80,000 BTU/h input) and the CAPEA2418B3 cased upflow/downflow evaporator coil with factory-installed EEV. This combination delivers efficient all-season comfort: variable-speed heat pump operation for moderate temperatures and automatic switchover to gas furnace heating when outdoor conditions drop below the balance point. AHRI Certified Reference Number: 215488329.

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

System Components

  • GZV6SA2410 — Goodman 2-Ton, 18.0 SEER2 / 8.5 HSPF2, Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser (23,200 BTU/h cooling, 23,200 BTU/h heating at 47°F)
  • GDVM970803BN — Goodman 80,000 BTU/h Input (77,000 BTU/h Output), 97% AFUE, Modulating, Variable-Speed ECM, Downflow/Horizontal Gas Furnace
  • CAPEA2418B3 — Goodman 2 Ton Nominal, Cased Upflow/Downflow, All-Aluminum Evaporator Coil with Factory-Installed EEV (17½" W × 21" D × 18" H)

Pro-Installer Tip

The Technical Friction: Downflow 97% AFUE condensing furnaces require careful condensate routing. In a dual fuel configuration with the GZV6SA2410 heat pump, the heat pump's defrost cycle generates additional condensate that must be managed alongside the furnace condensate drain. Cabinet clearance for the 17½" wide coil on a downflow installation demands precise alignment to prevent air leaks at the coil-to-furnace junction.

The Long-Term Prevention: Apply mastic sealant (not tape) at all coil-to-furnace seams and verify the condensate trap depth is at least 2× the maximum negative static pressure. This prevents nuisance water sensor trips and secondary drain pan overflow during peak cooling 6–12 months post-install.

The Expert Validation: Use a digital manometer to verify total external static pressure stays within the furnace's rated range. Document subcooling at 12±1°F using a calibrated digital refrigerant gauge set per the GZV6S specification sheet.

The Professional Standard: R-32 systems require EPA Section 608 certification for handling. Verify all brazing is performed with nitrogen purge per ACCA/ANSI Quality Installation Standard 5 (QI 5). Confirm local mechanical code compliance for condensing furnace venting with PVC/CPVC, which varies by jurisdiction.

Key Benefits

  • High-Efficiency Performance: 18.0 SEER2 and 8.5 HSPF2 ratings with variable-speed inverter technology reduce energy consumption compared to single-speed systems by running at lower speeds for longer periods, matching output to actual demand.
  • R-32 Refrigerant: GWP of 675 — approximately 68% lower than R-410A (GWP 2,088). Supports 2025 EPA AIM Act HFC phase-down requirements and reduces direct greenhouse gas emission potential.
  • Variable-Speed Operation: The swing compressor adjusts speed continuously rather than cycling on/off, providing tighter temperature control (±0.5°F vs. ±2°F for single-stage), reduced humidity, and lower sound levels (as low as 45 dBA in Quiet Mode).
  • Dual Fuel Flexibility: Automatically switches between heat pump and 80,000 BTU/h gas furnace based on outdoor temperature, optimizing operating cost by using the most efficient heat source for current conditions.
  • Condensing Furnace Efficiency: 97% AFUE captures latent heat from flue gases via a secondary heat exchanger, extracting more usable heat per therm of gas consumed.
  • Communicating System: EEV-equipped indoor components work with the outdoor unit's control board to optimize refrigerant flow and system performance. Compatible with Goodman GTST connected thermostat for advanced diagnostics.
  • Cold Climate Capable: ENERGY STAR Most Efficient 2025 (Cold Climate) certified. Heat pump operates down to -10°F ambient, delivering 14,200 BTU/h at 5°F for reliable heating in harsh conditions.

Technical Specifications

Specification Value
AHRI Certificate Number 215488329
System Type Dual Fuel System
Nominal Capacity 2 Ton
SEER2 18.0
EER2 10.2
HSPF2 8.5
Refrigerant R-32
Cooling Capacity (95°F) 23,200 BTU/h
Heating Capacity (47°F) 23,200 BTU/h
Heating Capacity (5°F) 14,200 BTU/h
Furnace Input 80,000 BTU/h
Furnace Output 77,600 BTU/h
Furnace AFUE 97%
Gas Valve Modulating
Outdoor Unit Dimensions (W×D×H) 36⅝" × 13¾" × 27⅜"
Outdoor Unit Weight 122 lbs
Evaporator Coil Dimensions (W×D×H) 17½" × 21" × 18"
Evaporator Coil Weight 43 lbs (shipping)
Expansion Device EEV (Electronic Expansion Valve)
Compressor Type Variable-Speed Swing
Outdoor Unit Voltage 208-230V / 1 Phase / 60 Hz
Min. Circuit Ampacity (Outdoor) 16.8A
Max Overcurrent Protection (Outdoor) 20A
Liquid Line Size ⅜"
Suction Line Size ¾"
Factory Charge 74 oz
Sound Level (Quiet Mode) As low as 45 dBA
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.

Compliance & Environmental Data

Item Detail
Refrigerant Type R-32 (Difluoromethane)
Global Warming Potential (GWP) 675 (~68% lower than R-410A)
EPA 608 Certification Required Yes — Section 608 certification required for purchase, handling, and service of R-32 refrigerant
AHRI Certified Yes — AHRI Certificate #215488329
ETL Listed Yes
ENERGY STAR® ENERGY STAR Most Efficient 2025 (Cold Climate Heat Pump)
Regional Compliance Meets DOE 2023 regional efficiency standards for all U.S. regions
Federal Tax Credit Eligibility System may qualify for federal tax credits under IRS Section 25C for qualifying high-efficiency HVAC equipment — verify current thresholds and requirements with a qualified tax professional

Warranty & Registration

Each component in this system carries its own manufacturer warranty from Daikin Comfort Technologies. Online registration within 60 days of installation is strongly recommended to obtain extended coverage.

  • Outdoor Unit (GZV6SA2410): Unregistered: 5-Year Parts Limited Warranty. Registered (within 60 days): 10-Year Parts Limited Warranty; if the compressor fails within 10 years, Daikin will furnish a new equivalent replacement unit (one-time). Register at www.goodmanmfg.com.
  • Gas Furnace (GDVM970803BN): Unregistered: 20-Year Heat Exchanger Limited Warranty; 5-Year Parts Limited Warranty. Registered (within 60 days): Lifetime Heat Exchanger Limited Warranty (as long as original owner resides in home); 10-Year Unit Replacement Limited Warranty (for heat exchanger failure within 10 years); 10-Year Parts Limited Warranty. Register at www.goodmanmfg.com.
  • Evaporator Coil (CAPEA2418B3): Unregistered: 5-Year Parts Limited Warranty. Registered (within 60 days): 10-Year Parts Limited Warranty. Register at www.goodmanmfg.com.

Warranty coverage applies to owner-occupied residences. Online registration is not required in California, Florida, or Québec. Duration of coverage in Texas and Florida may differ. Refer to individual component warranty documents for complete terms, limitations, and exclusions.