Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Free Shipping | Call for Best Pricing: 1-800-315-4345

Got a Question? Call Us

Phone Icon 1-800-315-4345

Monday-Saturday 9am-6pm EST

Goodman 2 Ton 18.0 SEER2 R-32 Dual Fuel System | GZV6SA2410 + GMVC960403BN + CAPEA3022B3 | Communicating | 40,000 BTU Upflow/Horizontal Two-Stage Variable-Speed ECM 96% AFUE Furnace | 17½" Wide Upflow/Downflow Coil

SKU: GZV6SA2410-GMVC960403BN-CAPEA3022B3
Your Price:
$5,703.00 $7,300.00
You Save: $1,597.00 22%
Checkout Secure

Quantity Remaining:

84 of 100 Sold
Order in the next to get it by

This AHRI-certified Dual Fuel System pairs the Goodman GZV6SA2410 2-ton, 18.0 SEER2, 8.5 HSPF2 variable-speed inverter-driven R-32 heat pump with the GMVC960403BN 96% AFUE two-stage gas furnace (40,000 BTU/h input) and the CAPEA3022B3 cased upflow/downflow evaporator coil with factory-installed EEV. This combination delivers efficient all-season comfort: variable-speed heat pump operation for moderate temperatures and automatic switchover to gas furnace heating when outdoor conditions drop below the balance point. AHRI Certified Reference Number: 215488310.

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

System Components

  • GZV6SA2410 — Goodman 2-Ton, 18.0 SEER2 / 8.5 HSPF2, Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser (23,200 BTU/h cooling, 23,200 BTU/h heating at 47°F)
  • GMVC960403BN — Goodman 40,000 BTU/h Input (38,000 BTU/h Output), 96% AFUE, Two-Stage, Variable-Speed ECM, Upflow/Horizontal Gas Furnace
  • CAPEA3022B3 — Goodman 2.5 Ton Nominal, Cased Upflow/Downflow, All-Aluminum Evaporator Coil with Factory-Installed EEV (17½" W × 21" D × 22" H)

Pro-Installer Tip

The Technical Friction: In this dual fuel configuration, the 40,000 BTU two-stage furnace paired with the GZV6SA2410 heat pump requires precise changeover point calibration. The R-32 heat pump's variable-speed compressor provides effective heating down to -10°F, so the balance point where gas heat becomes more economical than electric may be lower than legacy R-410A systems — typically 25–35°F depending on local utility rates.

The Long-Term Prevention: Set the fossil fuel changeover at the calculated economic balance point, not a fixed temperature. Verify the 17½" coil-to-furnace fit is flush with no air bypass gaps. Apply UL 181B mastic at all connections to prevent conditioned air loss, which causes callbacks for uneven temperatures.

The Expert Validation: Use a digital manometer to confirm total external static pressure is within the furnace's rated specification. Verify R-32 charge using subcooling method: target 12±1°F at the outdoor unit service valve. All refrigerant work requires EPA Section 608 certification.

The Professional Standard: The R-32 refrigerant (GWP 675) supports 2025 EPA AIM Act HFC phase-down goals. This system may qualify for federal tax credits under IRS 25C for high-efficiency HVAC — verify current eligibility thresholds. Confirm all gas piping meets NFPA 54 and local mechanical code requirements.

Key Benefits

  • High-Efficiency Performance: 18.0 SEER2 and 8.5 HSPF2 ratings with variable-speed inverter technology reduce energy consumption compared to single-speed systems by running at lower speeds for longer periods, matching output to actual demand.
  • R-32 Refrigerant: GWP of 675 — approximately 68% lower than R-410A (GWP 2,088). Supports 2025 EPA AIM Act HFC phase-down requirements and reduces direct greenhouse gas emission potential.
  • Variable-Speed Operation: The swing compressor adjusts speed continuously rather than cycling on/off, providing tighter temperature control (±0.5°F vs. ±2°F for single-stage), reduced humidity, and lower sound levels (as low as 45 dBA in Quiet Mode).
  • Dual Fuel Flexibility: Automatically switches between heat pump and 40,000 BTU/h gas furnace based on outdoor temperature, optimizing operating cost by using the most efficient heat source for current conditions.
  • Condensing Furnace Efficiency: 96% AFUE captures latent heat from flue gases via a secondary heat exchanger, extracting more usable heat per therm of gas consumed.
  • Communicating System: EEV-equipped indoor components work with the outdoor unit's control board to optimize refrigerant flow and system performance. Compatible with Goodman GTST connected thermostat for advanced diagnostics.
  • Cold Climate Capable: ENERGY STAR Most Efficient 2025 (Cold Climate) certified. Heat pump operates down to -10°F ambient, delivering 14,200 BTU/h at 5°F for reliable heating in harsh conditions.

Technical Specifications

Specification Value
AHRI Certificate Number 215488310
System Type Dual Fuel System
Nominal Capacity 2 Ton
SEER2 18.0
EER2 10.2
HSPF2 8.5
Refrigerant R-32
Cooling Capacity (95°F) 23,200 BTU/h
Heating Capacity (47°F) 23,200 BTU/h
Heating Capacity (5°F) 14,200 BTU/h
Furnace Input 40,000 BTU/h
Furnace Output 38,400 BTU/h
Furnace AFUE 96%
Gas Valve Two-Stage
Outdoor Unit Dimensions (W×D×H) 36⅝" × 13¾" × 27⅜"
Outdoor Unit Weight 122 lbs
Evaporator Coil Dimensions (W×D×H) 17½" × 21" × 22"
Evaporator Coil Weight 48 lbs (shipping)
Expansion Device EEV (Electronic Expansion Valve)
Compressor Type Variable-Speed Swing
Outdoor Unit Voltage 208-230V / 1 Phase / 60 Hz
Min. Circuit Ampacity (Outdoor) 16.8A
Max Overcurrent Protection (Outdoor) 20A
Liquid Line Size ⅜"
Suction Line Size ¾"
Factory Charge 74 oz
Sound Level (Quiet Mode) As low as 45 dBA
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.

Compliance & Environmental Data

Item Detail
Refrigerant Type R-32 (Difluoromethane)
Global Warming Potential (GWP) 675 (~68% lower than R-410A)
EPA 608 Certification Required Yes — Section 608 certification required for purchase, handling, and service of R-32 refrigerant
AHRI Certified Yes — AHRI Certificate #215488310
ETL Listed Yes
ENERGY STAR® ENERGY STAR Most Efficient 2025 (Cold Climate Heat Pump)
Regional Compliance Meets DOE 2023 regional efficiency standards for all U.S. regions
Federal Tax Credit Eligibility System may qualify for federal tax credits under IRS Section 25C for qualifying high-efficiency HVAC equipment — verify current thresholds and requirements with a qualified tax professional

Warranty & Registration

Each component in this system carries its own manufacturer warranty from Daikin Comfort Technologies. Online registration within 60 days of installation is strongly recommended to obtain extended coverage.

  • Outdoor Unit (GZV6SA2410): Unregistered: 5-Year Parts Limited Warranty. Registered (within 60 days): 10-Year Parts Limited Warranty; if the compressor fails within 10 years, Daikin will furnish a new equivalent replacement unit (one-time). Register at www.goodmanmfg.com.
  • Gas Furnace (GMVC960403BN): Unregistered: 20-Year Heat Exchanger Limited Warranty; 5-Year Parts Limited Warranty. Registered (within 60 days): Lifetime Heat Exchanger Limited Warranty (as long as original owner resides in home); 10-Year Unit Replacement Limited Warranty (for heat exchanger failure within 10 years); 10-Year Parts Limited Warranty. Register at www.goodmanmfg.com.
  • Evaporator Coil (CAPEA3022B3): Unregistered: 5-Year Parts Limited Warranty. Registered (within 60 days): 10-Year Parts Limited Warranty. Register at www.goodmanmfg.com.

Warranty coverage applies to owner-occupied residences. Online registration is not required in California, Florida, or Québec. Duration of coverage in Texas and Florida may differ. Refer to individual component warranty documents for complete terms, limitations, and exclusions.