This AHRI-certified Dual Fuel System pairs the Goodman GZV6SA2410 2-ton, 18.0 SEER2, 8.5 HSPF2 variable-speed inverter-driven R-32 heat pump with the GRVT800603BN 80% AFUE two-stage gas furnace (60,000 BTU/h input) and the CHPEA2422B3 cased horizontal evaporator coil with factory-installed EEV. This combination delivers efficient all-season comfort: variable-speed heat pump operation for moderate temperatures and automatic switchover to gas furnace heating when outdoor conditions drop below the balance point. AHRI Certified Reference Number: 215487282.
Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.
System Components
- GZV6SA2410 — Goodman 2-Ton, 18.0 SEER2 / 8.5 HSPF2, Variable-Speed Inverter-Driven R-32 Side Discharge Heat Pump Condenser (23,200 BTU/h cooling, 23,200 BTU/h heating at 47°F)
- GRVT800603BN — Goodman 60,000 BTU/h Input (48,000 BTU/h Output), 80% AFUE, Two-Stage, Variable-Speed ECM, Upflow/Horizontal Gas Furnace
- CHPEA2422B3 — Goodman 2 Ton Nominal, Cased Horizontal, All-Aluminum Evaporator Coil with Factory-Installed EEV (22" W × 21" D × 17½" H)
Pro-Installer Tip
The Technical Friction: Upflow 80% AFUE furnaces with the GZV6SA2410 heat pump use a conventional metal flue venting arrangement. In tight mechanical closets, the 60,000 BTU furnace's single-wall vent connector requires minimum 6-inch clearance to combustibles — verify this against the coil height (17½") stacked above the furnace before committing to the layout.
The Long-Term Prevention: Install a combustion air proving switch if the furnace is in a confined space. Check the dual fuel changeover setpoint (typically ~35°F outdoor ambient) to ensure the system doesn't short-cycle between heat pump and gas heat during shoulder-season temperature swings, which causes premature contactor wear.
The Expert Validation: After commissioning, verify combustion with a digital combustion analyzer: CO should be below 100 ppm air-free in flue gases, and draft should read –0.02" WC or more negative at the draft hood. Confirm heat pump subcooling at 12±1°F per GZV6S specs.
The Professional Standard: EPA Section 608 certification is required for R-32 refrigerant handling. Local building codes may require a two-stage gas valve for this installation — verify with the Authority Having Jurisdiction (AHJ). R-32 has a GWP of 675, roughly 68% lower than R-410A, supporting 2025 AIM Act phase-down targets.
Key Benefits
- High-Efficiency Performance: 18.0 SEER2 and 8.5 HSPF2 ratings with variable-speed inverter technology reduce energy consumption compared to single-speed systems by running at lower speeds for longer periods, matching output to actual demand.
- R-32 Refrigerant: GWP of 675 — approximately 68% lower than R-410A (GWP 2,088). Supports 2025 EPA AIM Act HFC phase-down requirements and reduces direct greenhouse gas emission potential.
- Variable-Speed Operation: The swing compressor adjusts speed continuously rather than cycling on/off, providing tighter temperature control (±0.5°F vs. ±2°F for single-stage), reduced humidity, and lower sound levels (as low as 45 dBA in Quiet Mode).
- Dual Fuel Flexibility: Automatically switches between heat pump and 60,000 BTU/h gas furnace based on outdoor temperature, optimizing operating cost by using the most efficient heat source for current conditions.
- Communicating System: EEV-equipped indoor components work with the outdoor unit's control board to optimize refrigerant flow and system performance. Compatible with Goodman GTST connected thermostat for advanced diagnostics.
- Cold Climate Capable: ENERGY STAR Most Efficient 2025 (Cold Climate) certified. Heat pump operates down to -10°F ambient, delivering 14,200 BTU/h at 5°F for reliable heating in harsh conditions.
Technical Specifications
| Specification | Value |
|---|---|
| AHRI Certificate Number | 215487282 |
| System Type | Dual Fuel System |
| Nominal Capacity | 2 Ton |
| SEER2 | 18.0 |
| EER2 | 10.2 |
| HSPF2 | 8.5 |
| Refrigerant | R-32 |
| Cooling Capacity (95°F) | 23,200 BTU/h |
| Heating Capacity (47°F) | 23,200 BTU/h |
| Heating Capacity (5°F) | 14,200 BTU/h |
| Furnace Input | 60,000 BTU/h |
| Furnace Output | 48,000 BTU/h |
| Furnace AFUE | 80% |
| Gas Valve | Two-Stage |
| Outdoor Unit Dimensions (W×D×H) | 36⅝" × 13¾" × 27⅜" |
| Outdoor Unit Weight | 122 lbs |
| Evaporator Coil Dimensions (W×D×H) | 22" × 21" × 17½" |
| Evaporator Coil Weight | 56 lbs (shipping) |
| Expansion Device | EEV (Electronic Expansion Valve) |
| Compressor Type | Variable-Speed Swing |
| Outdoor Unit Voltage | 208-230V / 1 Phase / 60 Hz |
| Min. Circuit Ampacity (Outdoor) | 16.8A |
| Max Overcurrent Protection (Outdoor) | 20A |
| Liquid Line Size | ⅜" |
| Suction Line Size | ¾" |
| Factory Charge | 74 oz |
| Sound Level (Quiet Mode) | As low as 45 dBA |
| Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications. | |
Compliance & Environmental Data
| Item | Detail |
|---|---|
| Refrigerant Type | R-32 (Difluoromethane) |
| Global Warming Potential (GWP) | 675 (~68% lower than R-410A) |
| EPA 608 Certification Required | Yes — Section 608 certification required for purchase, handling, and service of R-32 refrigerant |
| AHRI Certified | Yes — AHRI Certificate #215487282 |
| ETL Listed | Yes |
| ENERGY STAR® | ENERGY STAR Most Efficient 2025 (Cold Climate Heat Pump) |
| Regional Compliance | Meets DOE 2023 regional efficiency standards for all U.S. regions |
| Federal Tax Credit Eligibility | System may qualify for federal tax credits under IRS Section 25C for qualifying high-efficiency HVAC equipment — verify current thresholds and requirements with a qualified tax professional |
Warranty & Registration
Each component in this system carries its own manufacturer warranty from Daikin Comfort Technologies. Online registration within 60 days of installation is strongly recommended to obtain extended coverage.
- Outdoor Unit (GZV6SA2410): Unregistered: 5-Year Parts Limited Warranty. Registered (within 60 days): 10-Year Parts Limited Warranty; if the compressor fails within 10 years, Daikin will furnish a new equivalent replacement unit (one-time). Register at www.goodmanmfg.com.
- Gas Furnace (GRVT800603BN): Unregistered: 20-Year Heat Exchanger Limited Warranty; 5-Year Parts Limited Warranty. Registered (within 60 days): Lifetime Heat Exchanger Limited Warranty (as long as original owner resides in home); 10-Year Unit Replacement Limited Warranty (for heat exchanger failure within 10 years); 10-Year Parts Limited Warranty. Register at www.goodmanmfg.com.
- Evaporator Coil (CHPEA2422B3): Unregistered: 5-Year Parts Limited Warranty. Registered (within 60 days): 10-Year Parts Limited Warranty. Register at www.goodmanmfg.com.
Warranty coverage applies to owner-occupied residences. Online registration is not required in California, Florida, or Québec. Duration of coverage in Texas and Florida may differ. Refer to individual component warranty documents for complete terms, limitations, and exclusions.
Let customers speak for us