Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Free Shipping | Call for Best Pricing: 1-800-315-4345

Got a Question? Call Us

Phone Icon 1-800-315-4345

Monday-Saturday 9am-6pm EST

Goodman 2.5 Ton 17.5 SEER2 R-32 Central Heat Pump Split System with Evaporator Coil & Modular Blower [GZV6SA3010 + CAPEA3022B3 + MBVK12BP1X00] 21" Depth Cased Upflow/Downflow Coil, Multi-Positional Modular Blower, Communicating

SKU: GM-GZV6SA3010-CAPEA3022B3-MBVK12BP1X00-216611776
Your Price:
$4,834.00 $6,478.00
You Save: $1,644.00 26%
Checkout Secure

Quantity Remaining:

260 of 300 Sold
Order in the next to get it by

Goodman 2.5 Ton Central Heat Pump Split System with Evaporator Coil & Modular Blower

This AHRI-certified heat pump split system (Certificate #216611776) pairs the Goodman GZV6SA3010 2.5 Ton variable-speed heat pump condenser with the CAPEA3022B3 cased evaporator coil and MBVK12BP1X00 communicating modular blower. Rated at 17.5 SEER2 and 8.5 HSPF2, the system uses R-32 refrigerant (GWP 675) and features variable-speed operation for both the outdoor compressor and the indoor blower motor. This two-piece indoor configuration (separate coil and blower) provides installation flexibility in applications where a one-piece air handler may not fit.

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

System Components

  • GZV6SA3010 — 2.5 Ton Variable-Speed Heat Pump Condenser with R-32 refrigerant, Variable-Speed Swing compressor, and EEV (Electronic Expansion Valve).
  • CAPEA3022B3 — Cased Upflow/Downflow evaporator coil with all-aluminum construction and EEV (Electronic Expansion Valve). Cabinet dimensions: 17½" W × 21" D × 22" H.
  • MBVK12BP1X00 — Multi-Positional communicating modular blower with Variable-Speed ECM motor (½ HP), 1,200 CFM maximum airflow. Cabinet dimensions: 17½" W × 21" D × 26" H. Electrical: 208-230V / 1 Phase / 60 Hz.

Pro-Installer Tip

Technical Friction: The two-piece indoor setup (CAPEA3022B3 coil + MBVK12BP1X00 blower) requires precise alignment between the coil and blower cabinets. Both components share a 21″ depth for consistent ductwork connections, but the coil (17½" wide) and blower (17½" wide) must match in cabinet width to prevent air bypass at the connection point. Ensure the coil sits securely on the blower plenum with no gaps.

Long-Term Prevention: After brazing the R-32 line set, pull the system down to 300 microns and hold a standing vacuum for 20 minutes minimum. R-32 is less forgiving of moisture contamination than R-410A. A proper vacuum prevents acid formation that leads to compressor valve failure and nuisance lockouts 8–12 months post-install.

Expert Validation: Use a digital micron gauge (not an analog compound gauge) to verify the evacuation hold. After startup, verify superheat and subcooling using an R-32–calibrated manifold gauge set. The MBVK blower’s communicating controls will display real-time performance data once commissioned with a compatible Goodman smart thermostat.

Professional Standard: R-32 is classified as A2L (mildly flammable) and requires EPA Section 608 certification for refrigerant handling. For R-32 compatibility with the MBVK12BP1X00, verify that the R-32 integration kit has been installed per the manufacturer’s instructions. Pull all applicable mechanical and electrical permits per local code requirements.

Key Benefits

  • 17.5 SEER2 / 8.5 HSPF2 Efficiency: The variable-speed heat pump condenser and communicating modular blower work together to deliver high-efficiency cooling and heating across a wide range of outdoor conditions.
  • R-32 Low-GWP Refrigerant: R-32 has a Global Warming Potential of 675 — 68% lower than R-410A (GWP 2,088) — meeting current EPA AIM Act phase-down requirements while maintaining strong thermodynamic performance.
  • Variable-Speed Operation: Both the outdoor Variable-Speed Swing compressor and the indoor Variable-Speed ECM blower motor modulate output to match the actual load. This reduces temperature swings, improves humidity control, and lowers operating sound during part-load conditions.
  • All-Aluminum Evaporator Coil: The CAPEA3022B3 uses all-aluminum coil construction that resists galvanic corrosion, eliminating the copper-aluminum interface that causes formicary corrosion and premature coil failure in humid environments.
  • Modular Installation Flexibility: The separate coil-and-blower configuration allows installation in spaces that cannot accommodate a one-piece air handler. The 21″ cabinet depth on both components fits standard attic access openings.
  • Communicating Controls: The MBVK12BP1X00 features integrated ComfortBridge™ communicating technology for optimized airflow management, automatic fault diagnostics, and seamless integration with the outdoor heat pump unit.

Technical Specifications

Specification Value
System Ratings (AHRI Certificate #216611776)
SEER2 17.5
EER2 10.0
HSPF2 8.5
Cooling Capacity 28,400 BTU/h
Heating Capacity @ 47°F 28,800 BTU/h
Heating Capacity @ 17°F 18,000 BTU/h
Outdoor Unit — GZV6SA3010
Compressor Variable-Speed Swing
Refrigerant / Factory Charge R-32 / 76 oz
Dimensions (W×D×H) 36⅝" × 13¾" × 27⅜"
Shipping Weight 147 lbs
Electrical 208-230V / 1 Phase / 60 Hz
MCA / MOCP 22.4A / 25A
Line Connections (Liquid / Suction) ⅜" / ⅞"
Evaporator Coil — CAPEA3022B3
Coil Configuration Cased Upflow/Downflow
Cabinet Dimensions (W×D×H) 17½" × 21" × 22"
Expansion Device EEV (Electronic Expansion Valve)
Coil Material All-Aluminum
Modular Blower — MBVK12BP1X00
Configuration Multi-Positional
Motor Variable-Speed ECM (½ HP)
Maximum Airflow 1,200 CFM
Cabinet Dimensions (W×D×H) 17½" × 21" × 26"
Shipping Weight 67 lbs
Electrical 208-230V / 1 Phase / 60 Hz
MCA / MOCP 4.9A / 15A
Communicating Yes
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.

Compliance & Environmental Data

Category Details
Refrigerant Type R-32 (Difluoromethane)
Global Warming Potential (GWP) 675 (68% lower than R-410A)
ASHRAE Safety Classification A2L (Lower Flammability)
EPA Section 608 Certification required for handling R-32 refrigerant
AHRI Certified Yes — Certificate #216611776
ENERGY STAR® Certified Yes
Regional Compliance Meets DOE 2023 minimum efficiency standards for all U.S. regions
Federal Tax Credit Eligibility This system may qualify for federal tax credits under the Inflation Reduction Act (IRA) for high-efficiency HVAC equipment. Consult a qualified tax professional for eligibility based on your specific installation.

Warranty & Registration

Each component in this system carries its own manufacturer warranty from Daikin Comfort Technologies. Registration within 60 days of installation is strongly recommended to obtain the full warranty coverage.

  • Outdoor Heat Pump (GZV6SA3010): Unregistered—5-Year Parts Limited Warranty. Registered (within 60 days at goodmanmfg.com)—10-Year Parts Limited Warranty. If the compressor fails within 10 years on a registered unit, Daikin will furnish a new replacement unit (one-time).
  • Evaporator Coil (CAPEA3022B3): Unregistered—5-Year Parts Limited Warranty. Registered (within 60 days)—10-Year Parts Limited Warranty.
  • Modular Blower (MBVK12BP1X00): Unregistered—5-Year Parts Limited Warranty. Registered (within 60 days at goodmanmfg.com)—10-Year Parts Limited Warranty.

Warranty coverage applies to owner-occupied residences installed within the United States, its territories, or Canada. Units must be installed by a qualified HVAC contractor adhering to all applicable codes. Complete warranty terms available at goodmanmfg.com.