Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Free Shipping | Call for Best Pricing: 1-800-315-4345

Got a Question? Call Us

Phone Icon 1-800-315-4345

Monday-Saturday 9am-6pm EST

Goodman 2.5 Ton 17.5 SEER2 R-32 Dual Fuel System | GZV6SA3010 + CAPEA3626C3 + GCVC961005CN | 21" Wide Upflow/Downflow Cased Coil | 100,000 BTU/h Downflow/Horizontal Two-Stage Variable-Speed ECM Natural Gas Furnace | Communicating

SKU: GZV6SA3010-CAPEA3626C3-GCVC961005CN-216611849
Your Price:
$6,923.00 $8,792.00
You Save: $1,869.00 22%
Checkout Secure

Quantity Remaining:

198 of 200 Sold
Order in the next to get it by

Goodman 2.5 Ton 17.5 SEER2 R-32 Dual Fuel System

This AHRI-certified dual fuel system (Certificate #216611849) pairs the Goodman GZV6SA3010 2.5-ton variable-speed inverter-driven R-32 heat pump condenser with the GCVC961005CN 96% AFUE two-stage gas furnace (100,000 BTU/h input) and the CAPEA3626C3 cased upflow/downflow evaporator coil with factory-installed electronic expansion valve (EEV) with ComfortBridge™ communicating technology. Rated at 17.5 SEER2 / 10.0 EER2 / 8.5 HSPF2, this matched system delivers 28,400 BTU/h cooling capacity and 28,800 BTU/h heating capacity at 47°F. The outdoor unit is ENERGY STAR® Cold Climate Certified and operates on low-GWP R-32 refrigerant (GWP: 675).

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

System Components

  • GZV6SA3010 — Goodman 2.5-Ton Variable-Speed Inverter-Driven R-32 Heat Pump Condenser. Side-discharge cabinet with variable-speed swing compressor, digitally commutated fan motor, and EEV (Electronic Expansion Valve). Quiet-mode operation available (as low as 45 dBA).
  • CAPEA3626C3 — Goodman Cased Upflow/Downflow Evaporator Coil with factory-installed electronic expansion valve (EEV). All-aluminum coil optimized for R-32 refrigerant. Cabinet dimensions: 21" W × 21" D × 26" H. 21" depth designed for easier attic access.
  • GCVC961005CN — Goodman 96% AFUE Two-Stage Variable-Speed ECM Gas Furnace. 100,000 BTU/h input capacity with two-stage gas valve that provides low-fire and high-fire operation. Downflow/Horizontal configuration, 21" cabinet width. Natural Gas emissions rated.

🔧 Pro-Installer Tip

The Technical Friction: When installing this dual fuel system with a downflow/horizontal furnace and upflow/downflow coil in a closet or utility room application, verify the combined height of the furnace and coil assembly clears the available vertical space. The 26" coil height stacked with the furnace can challenge tight mechanical rooms, particularly in retrofit applications where the original equipment had a smaller footprint.

Long-Term Prevention: With R-32 refrigerant at 76 oz factory charge, ensure all brazed joints are nitrogen-pressurized during brazing and leak-tested to 500 PSI standing pressure for 20 minutes minimum. R-32 operates at slightly higher pressures than R-410A, and micro-leaks at field connections are the leading cause of nuisance low-charge lockouts within the first 12 months of operation. Pull the system vacuum to 300 microns or below and verify it holds under 500 microns for 15 minutes.

Expert Validation: Use a calibrated digital micron gauge (not a compound gauge) to verify vacuum levels. A digital manifold with R-32 PT tables ensures accurate superheat/subcooling verification at commissioning. The GZV6S outdoor unit targets 76 oz factory charge for 15 ft of ⅜" liquid line — adjust charge per the installation instructions for longer line sets.

Professional Standard: All R-32 installations require EPA Section 608 certification. Verify local mechanical codes for furnace clearance-to-combustibles, particularly in downflow/horizontal configurations where the heat exchanger proximity to flooring materials must meet NFPA 90B standards. Confirm the condensate drain meets local plumbing code requirements for both the evaporator coil and the furnace secondary heat exchanger.

Key Benefits

  • Dual Fuel Flexibility: System automatically switches between electric heat pump operation and gas furnace heating based on outdoor temperature, optimizing energy costs across all climate conditions.
  • High-Efficiency Ratings: 17.5 SEER2 cooling and 8.5 HSPF2 heating efficiency with 96% AFUE gas furnace backup delivers year-round energy savings compared to standard single-fuel systems.
  • Variable-Speed Operation: The inverter-driven compressor adjusts capacity continuously to match actual load conditions, reducing temperature swings and improving humidity control during partial-load operation.
  • Low-GWP Refrigerant: R-32 refrigerant (GWP: 675) reduces environmental impact by approximately 68% compared to R-410A (GWP: 2,088) while delivering comparable or improved heat transfer efficiency.
  • Quiet Performance: Outdoor unit operates at 67 dBA in cooling and 70 dBA in heating under normal mode, with Quiet Mode reducing sound levels as low as 45 dBA for noise-sensitive installations.
  • Two-Stage Furnace Heating: The two-stage gas valve provides low-fire operation for mild conditions and high-fire for peak demand, improving comfort and reducing fuel consumption.

Technical Specifications

Specification Details
AHRI Certificate Number 216611849
System Type Dual Fuel (Heat Pump + Gas Furnace), Communicating
Nominal Capacity 2.5 Ton (28,400 BTU/h Cooling)
SEER2 / EER2 17.5 / 10.0
HSPF2 8.5
Heating Capacity @ 47°F 28,800 BTU/h
Heating Capacity @ 5°F 17,300 BTU/h
Furnace Input (BTU/h) 100,000 BTU/h
Furnace AFUE 96%
Refrigerant R-32 (Factory Charge: 76 oz)
Compressor Type Variable-Speed Swing
Expansion Device EEV (Electronic Expansion Valve)
Outdoor Unit — GZV6SA3010
Dimensions (W×D×H) 36⅝" × 13¾" × 27⅜"
Equipment Weight / Shipping 132 lbs / 147 lbs
Sound Level (Cooling / Heating) 67 dBA / 70 dBA
Electrical 208-230V / 1 Ph / 60 Hz
MCA / MOCP 22.4A / 25A
Line Connections (Liquid / Suction) ⅜" / ⅞"
Evaporator Coil — CAPEA3626C3
Coil Configuration Cased Upflow/Downflow
Cabinet Dimensions (W×D×H) 21" × 21" × 26"
Expansion Device EEV (Electronic Expansion Valve)
Coil Material All-Aluminum
Gas Furnace — GCVC961005CN
Furnace Configuration Downflow/Horizontal
Gas Valve Two-Stage
Motor Variable-Speed ECM
Cabinet Width 21"
NOx Emissions Natural Gas
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.

Compliance & Environmental Data

Category Details
Refrigerant Type R-32
Global Warming Potential (GWP) 675 (vs. 2,088 for R-410A)
EPA Section 608 Certification Required for all technicians handling R-32 refrigerant
AHRI Certified Yes — Certificate #216611849
ENERGY STAR® Certified ENERGY STAR® Cold Climate Certified
Regional Compliance Meets DOE 2023 minimum efficiency standards nationwide
NOx Emissions (Furnace) Natural Gas
Federal Tax Credit Eligibility This system may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA) — consult a qualified tax advisor for eligibility based on your specific installation

Warranty & Registration

  • Outdoor Unit (GZV6SA3010) — Heat Pump Warranty:
    • Unregistered: 5-Year Parts Limited Warranty.
    • Registered (within 60 days of installation at www.goodmanmfg.com): 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty (compressor failure — one-time replacement of entire outdoor unit).
  • Evaporator Coil (CAPEA3626C3) — Indoor Coil Warranty:
    • Unregistered: 5-Year Parts Limited Warranty.
    • Registered (within 60 days of installation at www.goodmanmfg.com): 10-Year Parts Limited Warranty.
  • Gas Furnace (GCVC961005CN) — Furnace Warranty:
    • Unregistered: 20-Year Heat Exchanger Limited Warranty and 5-Year Parts Limited Warranty.
    • Registered (within 60 days of installation at www.goodmanmfg.com): Lifetime Heat Exchanger Limited Warranty (up to 99 years, one replacement after year 20), 10-Year Parts Limited Warranty, and 10-Year Unit Replacement Limited Warranty.

All warranties apply to original owner-occupied residential installations only. Online registration must be completed within 60 days of installation. Registration not required in California, Florida, or Québec. Warranty duration may differ in Texas and Florida. Refer to complete warranty documents for full terms, limitations, and exclusions.