This AHRI-certified Goodman 2.5 Ton Central Heat Pump Split System with Evaporator Coil and Modular Blower delivers 17.5 SEER2 and 8.5 HSPF2 efficiency using R-32 refrigerant (GWP 675). The system pairs the GZV6SA3010 variable-speed heat pump condenser with the CAPEA3626D3 upflow/downflow evaporator coil and the MBVK16CP1X00 variable-speed ECM modular blower, verified under AHRI Certificate #216611798. This configuration is Energy Star Cold Climate certified, providing reliable heating performance down to -10°F.
Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.
System Components
- GZV6SA3010 — 2.5 Ton Variable-Speed Inverter-Driven R-32 Side-Discharge Heat Pump Condenser (28,400 BTU/h Cooling / 28,800 BTU/h Heating @ 47°F)
- CAPEA3626D3 — Cased Upflow/Downflow Evaporator Coil with EEV (24½" W × 21" D × 26" H, Upflow/Downflow Configuration)
- MBVK16CP1X00 — Variable-Speed ECM Multi-Positional Modular Blower (21" W × 21" D × 30" H, ¾ HP Motor)
Fit: 1.75" Offset — AHRI Certificate: #216611798
Pro-Installer Tip
Technical Friction: The GZV6S series uses R-32 refrigerant with an EEV on both the outdoor unit and the CAPEA3626D3 indoor coil. During installation, the two-piece modular blower and coil assembly requires precise alignment — a 1.75" Offset fit between the MBVK16CP1X00 blower (21" cabinet) and the CAPEA3626D3 coil (24½" cabinet) demands careful attention to transition fitment and seal integrity to prevent air bypass.
Long-Term Prevention: Pull a deep vacuum to 350 microns or below and hold for 15 minutes before charging. R-32 operates at approximately 12% higher discharge pressures than R-410A, making moisture contamination a more significant concern. Verify subcooling at 14±1°F at the service valve. A properly evacuated system prevents non-condensable gas accumulation that causes high head pressure nuisance calls 6-12 months post-installation.
Expert Validation: Use a digital micron gauge (not a compound gauge) to verify vacuum depth. Confirm subcooling with a digital manifold that compensates for R-32 properties. Verify blower airflow using the onboard CFM indicator — the variable-speed ECM motor should be configured for the matched tonnage in communicating mode.
Professional Standard: R-32 is an A2L mildly flammable refrigerant — ensure all installation practices comply with UL 60335-2-40 and local mechanical code requirements for A2L refrigerant systems. EPA Section 608 certification is required. This system meets 2023 Florida Building Code unit integrity requirements when properly anchored.
Key Benefits
- 17.5 SEER2 / 8.5 HSPF2 Efficiency — Variable-speed inverter compressor modulates capacity from low-stage to full-stage, reducing energy consumption during partial-load conditions that account for the majority of annual runtime hours.
- R-32 Low-GWP Refrigerant (GWP 675) — R-32 has 68% lower global warming potential than R-410A (GWP 2,088), uses approximately 20% less refrigerant charge by weight, and delivers improved thermodynamic efficiency at the same operating conditions.
- Cold Climate Heat Pump Performance — Energy Star Cold Climate certified with continuous heating capacity down to -10°F (17,300 BTU/h @ 5°F), reducing reliance on supplemental electric heat strips in the modular blower.
- Quiet Operation with Three-Level Sound Control — Normal-mode sound rating of 67 dBA (cooling) with field-selectable quiet mode (as low as 45 dBA), well below most municipal nighttime noise ordinances of 55 dBA.
- Variable-Speed ECM Blower Motor — The MBVK16CP1X00 modular blower provides constant CFM across a wide range of static pressures, improving dehumidification control and maintaining consistent comfort in communicating mode.
- All-Aluminum Evaporator Coil with EEV — The CAPEA3626D3 features an all-aluminum coil optimized for R-32 with an integrated electronic expansion valve for precise superheat control across the full modulation range.
Technical Specifications
| AHRI Certificate Number | 216611798 |
| System Type | Central Heat Pump Split System with Evaporator Coil & Modular Blower |
| Nominal Capacity | 2.5 Ton |
| SEER2 / EER2 | 17.5 / 10.0 |
| HSPF2 | 8.5 |
| Cooling Capacity (95°F) | 28,400 BTU/h |
| Heating Capacity (47°F) | 28,800 BTU/h |
| Heating Capacity (5°F) | 17,300 BTU/h |
| Refrigerant / Charge | R-32 / 76 oz |
| Compressor Type | Variable-Speed Swing |
| Expansion Device | EEV (Electronic Expansion Valve) |
| Coil-to-Blower Fit | 1.75" Offset |
| Outdoor Unit — GZV6SA3010 | |
| Outdoor Unit Dimensions (W×D×H) | 36⅝" × 13¾" × 27⅜" |
| Outdoor Unit Weight / Ship Weight | 132 lbs / 147 lbs |
| Electrical | 208-230V / 1 Phase / 60 Hz |
| MCA / MOCP | 22.4A / 25A |
| Sound Level (Cooling / Heating) | 67 dBA / 70 dBA |
| Refrigerant Lines (Liquid / Suction) | ⅜" / ⅞" |
| Evaporator Coil — CAPEA3626D3 | |
| Coil Configuration | Upflow/Downflow, Cased |
| Coil Dimensions (W×D×H) | 24½" × 21" × 26" |
| Coil Ship Weight | 62 lbs |
| Modular Blower — MBVK16CP1X00 | |
| Blower Configuration | Multi-Positional (Horizontal or Vertical) |
| Blower Dimensions (W×D×H) | 21" × 21" × 30" |
| Blower Motor | ¾ HP Variable-Speed ECM |
| Blower Ship Weight | 80 lbs |
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.
Compliance & Environmental Data
| Refrigerant Type | R-32 (Difluoromethane) |
| Global Warming Potential (GWP) | 675 (68% lower than R-410A) |
| ASHRAE Safety Classification | A2L (Lower Flammability) |
| EPA Section 608 Certification | Required for purchase, installation, and service |
| UL Safety Compliance | UL 60335-2-40 (A2L Refrigerant Systems) |
| Energy Star Certified | Yes (Cold Climate) |
| Regional Compliance | Meets DOE 2023 minimum efficiency standards for all U.S. regions |
| Federal Tax Credit Eligibility | This system may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (25C). Consult a qualified tax professional for eligibility based on your specific situation and current IRS guidelines. |
Warranty & Registration
Each component in this system carries its own manufacturer warranty. Online registration must be completed within 60 days of installation to receive the full warranty coverage. Registration is not required in California, Florida, or Québec.
- GZV6SA3010 (Heat Pump Condenser): 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty when registered online within 60 days of installation. Without registration, coverage defaults to a reduced term. One-time Compressor Replacement coverage is available for years 11-99 through an ASURE Extend Service Plan. Duration of coverage may differ in Texas and Florida.
- CAPEA3626D3 (Evaporator Coil): 10-Year Parts Limited Warranty when registered online within 60 days of installation. Without timely registration, a reduced warranty term applies. Duration of coverage may differ in Texas and Florida.
- MBVK16CP1X00 (Modular Blower): 10-Year Parts Limited Warranty when registered online within 60 days of installation. Without timely registration, a reduced warranty term applies. Duration of coverage may differ in Texas and Florida.
Warranty terms are subject to limitations and exclusions. Refer to the manufacturer's complete warranty documents for full details, rights, and obligations. Changes in law, regulations, or technology may affect warranty terms.
Let customers speak for us
What customers think about the store