Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Free Shipping | Call for Best Pricing: 1-800-315-4345

Got a Question? Call Us

Phone Icon 1-800-315-4345

Monday-Saturday 9am-6pm EST

Goodman | 3 Ton | 16.0 SEER2 | R-32 Refrigerant | Dual Fuel System | GZV6SA3610* + CAPEA3626D3 + GDVM970804CN | 24½" Cabinet Width | Upflow/Downflow | Coil | 80,000 BTU/h | Downflow/Horizontal | Modulating | Variable-Speed ECM | Natural Gas | Furnace

SKU: GM-GZV6SA3610-CAPEA3626D3-GDVM970804CN
Your Price:
$7,696.00
Checkout Secure

Quantity Remaining:

80 of 100 Sold
Order in the next to get it by

This Goodman 3-Ton 16.0 SEER2 Dual Fuel System pairs the GZV6S series variable-speed R-32 heat pump condenser (GZV6SA3610*) with a upflow/downflow evaporator coil (CAPEA3626D3) and a 80,000 BTU/h 97% AFUE downflow/horizontal gas furnace (GDVM970804CN). The system is AHRI certified (Certificate #215488242) and delivers up to 33,600 BTU/h in cooling and 34,600 BTU/h in heating at 47°F. The dual fuel configuration provides electric heat pump efficiency during moderate temperatures and automatically switches to gas heating when outdoor temperatures drop below the balance point, optimizing both energy usage and comfort.

Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.

System Components

  • GZV6SA3610* — Goodman GZV6S Series 3-Ton Variable-Speed R-32 Heat Pump Condenser, Side Discharge, 208-230V/1Ph/60Hz. Features a variable-speed swing compressor, digitally commutated fan motor, EEV metering, high-density compressor sound blanket, and proprietary control algorithmic logic.
  • CAPEA3626D3 — Goodman Upflow/Downflow Cased evaporator coil with Electronic Expansion Valve (EEV). Cabinet dimensions: 24½" W x 21" D x 26" H. All-aluminum coil optimized for R-32 refrigerant. Galvanized steel cabinet with leather grain-embossed finish and thermoplastic drain pan.
  • GDVM970804CN — Goodman Downflow/Horizontal Modulating Variable-Speed ECM gas furnace. 80,000 BTU/h input, 97% AFUE. 21" cabinet width, Natural Gas.

🛠 Pro-Installer Tip

Technical Friction: R-32 dual fuel systems require precise changeover point calibration between the heat pump and gas furnace. With the GZV6S variable-speed compressor ramping at partial loads, setting the balance point too high forces unnecessary gas usage; too low risks the heat pump running in extreme cold beyond its efficient range. Additionally, the R-32 refrigerant operates at approximately 12% higher discharge pressures than R-410A, demanding careful attention to brazing quality on suction and liquid connections.

Long-Term Prevention: After initial commissioning, verify the defrost termination temperature and reversing valve operation under load. A poorly calibrated defrost cycle on R-32 systems can cause liquid slugging to the compressor within the first heating season. Pull a standing vacuum to below 500 microns (target 300) and perform a 10-minute decay test before releasing the R-32 charge—moisture contamination degrades POE oil faster with R-32 than R-410A.

Expert Validation: Use a digital manifold gauge set rated for R-32 pressures (operating pressures can reach 580+ PSIG on the high side in cooling mode). Verify subcooling at the outdoor unit service valve against the factory charge chart, then confirm superheat at the indoor coil. A Fieldpiece SMAN480 or equivalent with R-32 PT charts is recommended for commissioning accuracy.

Professional Standard: R-32 is classified as an A2L (mildly flammable) refrigerant under ASHRAE 34. Per the 2021 UMC and local amendments, installations must comply with charge-size limits based on room volume (typically 6.3 oz/100 ft³ for occupied spaces). Ensure the installation meets all local mechanical code requirements for A2L refrigerants, including proper electrical classification of components in equipment rooms and adequate ventilation per manufacturer installation instructions.

Key Benefits

  • High-Efficiency Heating & Cooling: Rated at 16.0 SEER2 and 8.5 HSPF2, this system exceeds federal minimum efficiency standards and can reduce energy consumption compared to standard-efficiency equipment.
  • R-32 Refrigerant (Low GWP): R-32 has a Global Warming Potential (GWP) of 675—approximately 68% lower than R-410A (GWP 2,088). This next-generation refrigerant also delivers improved thermodynamic efficiency and requires less charge per system.
  • Variable-Speed Compressor Technology: The GZV6S swing compressor ramps up and down to match actual heating and cooling loads, reducing energy waste, minimizing temperature swings, and lowering operating sound levels compared to fixed-speed systems.
  • Dual Fuel Flexibility: Automatically transitions between electric heat pump mode and gas furnace heating based on outdoor temperature, optimizing energy costs while maintaining comfort through extreme cold.
  • Quiet Operation: The digitally commutated condenser fan motor and high-density compressor sound blanket help reduce outdoor noise levels, with quiet-mode capability providing up to three different sound levels (as low as 45 dBA).
  • Durable Construction: Heavy-gauge galvanized steel cabinet with custom ivory white powder-paint finish, high-corrosion ZAM® unpainted steel bottom frame, and 500-hour salt-spray tested components designed for long service life in demanding outdoor environments.

Technical Specifications

Specification Value
AHRI Certificate Number 215488242
System Type Dual Fuel System
Nominal Capacity 3 Ton
SEER2 16.0
HSPF2 8.5
Cooling Capacity 33,600 BTU/h
Heating Capacity (47°F) 34,600 BTU/h
Heating Capacity (17°F) 22,400 BTU/h
Refrigerant R-32
Compressor Type Variable-Speed Swing
Outdoor Unit Voltage 208-230V / 1 Phase / 60 Hz
Outdoor Unit Dimensions (W x D x H) See manufacturer specifications
Outdoor Unit Weight (Shipping) 151 lbs
Evaporator Coil Dimensions 24½" W x 21" D x 26" H
Coil Configuration Upflow/Downflow, Cased
Expansion Device (Coil) Electronic Expansion Valve (EEV)
Furnace Input 80,000 BTU/h
Furnace AFUE 97%
Furnace Configuration Downflow/Horizontal
Gas Valve Type Modulating
Blower Motor Variable-Speed ECM
Furnace Cabinet Width 21"
Furnace NOx Rating Natural Gas
Communicating System No (Standard Non-Communicating)
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.

Compliance & Environmental Information

Item Details
Refrigerant Type R-32 (Difluoromethane)
Refrigerant GWP 675 (approximately 68% lower than R-410A)
Refrigerant Classification A2L (Mildly Flammable) per ASHRAE 34
EPA Section 608 Technicians must hold a valid EPA 608 certification to handle R-32 refrigerant. Proper recovery, recycling, and reclamation practices apply.
Regional Compliance Meets federal minimum efficiency standards for all U.S. regions. Verify local A2L refrigerant code adoption before installation.
Tax Credit Eligibility Systems meeting applicable efficiency thresholds may qualify for federal energy efficiency tax credits under the Inflation Reduction Act (IRA). Consult a tax professional and verify current IRS requirements at energystar.gov for the latest eligible product lists.

Warranty & Registration

  • Outdoor Heat Pump (GZV6SA3610*): 10-Year Parts Limited Warranty and 10-Year Unit Replacement Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year coverage on all parts. A one-time compressor replacement is available to the original homeowner for years 11-99 after installation through an ASURE Extend Service Plan.
  • Evaporator Coil (CAPEA3626D3): 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 5-Year parts coverage.
  • Gas Furnace (GDVM970804CN): Lifetime Heat Exchanger Limited Warranty (for as long as the original registered owner owns the home), 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty when properly registered online at www.goodmanmfg.com within 60 days of installation. Without registration, the Initial Term Warranty provides 20-Year Heat Exchanger coverage and 5-Year parts coverage.

Registration is not required in California, Florida, or Québec. The duration of warranty coverage in Texas and Florida may differ. See manufacturer warranty documents for complete terms and exclusions.