This Goodman 3-Ton Central Heat Pump Split System with Evaporator Coil & Modular Blower pairs the GZV6SA3610* variable-speed heat pump with the CAPEA3626D3 evaporator coil and MBVK20DP1X00 communicating modular blower. AHRI-certified (Certificate #215447615) at 16.6 SEER2 and 8.5 HSPF2, this configuration uses R-32 low-GWP refrigerant and provides efficient all-electric heating and cooling. The modular blower and coil design offers flexible installation options in both vertical and horizontal orientations.
Note: If you would like to review the manufacturer Product Specifications, Warranty, Brochure, etc., for this system, please refer to the 'Resources (System Manuals and Warranty)' Tab above on this page.
System Components
- Outdoor Heat Pump Condenser: Goodman GZV6SA3610* — 3-Ton variable-speed inverter-driven R-32 heat pump with swing compressor, EEV metering, and digitally commutated condenser fan motor. Sound power as low as 45 dBA in quiet mode.
- Evaporator Coil: Goodman CAPEA3626D3A* — 3-Ton cased Upflow/Downflow all-aluminum evaporator coil with integrated EEV, factory-installed R-32 sensor, and thermoplastic drain pan with secondary drain connection.
- Modular Blower: Goodman MBVK20DP1X00AA — 2000-CFM variable-speed ECM communicating modular blower (24-1/2") with SmartFrame cabinet, integrated ComfortBridge technology, and built-in dehumidification feature. Compatible with R-32 refrigerant with integration kit.
Pro-Installer Tip
The Technical Friction: The two-piece coil-and-blower configuration offers installation flexibility, but the coil width must match the blower cabinet width for a proper seal. Mismatched widths create air bypass around the coil face, reducing system capacity and triggering low-superheat fault codes from the outdoor unit's EEV controller.
The Long-Term Prevention: After mounting the coil on the blower, verify the drain pan rail alignment and apply foil-faced tape at the coil-to-blower junction seam. Pressure-test the completed assembly with a duct leakage tester — total air leakage should remain below 2% at 1.0" w.c. per ASHRAE 193. This prevents efficiency loss and condensation issues that often surface 6-8 months after installation.
The Expert Validation: Verify the communicating connection between the MBVK blower, the evaporator coil's EEV, and the outdoor unit through the CoolCloud app. Confirm the blower is configured for the correct tonnage setting and that the EEV superheat is auto-controlled, with subcooling reading 15 +/- 1 deg.F at the outdoor unit's service valve.
The Professional Standard: The R-32 integration kit must be installed on the blower for R-32 compatibility. Verify the R-32 leak sensor on the coil is functional before sealing the access panel. In jurisdictions enforcing ASHRAE 15 or state-level A2L refrigerant handling requirements, ensure the installation meets maximum charge density limits for the occupied space.
Key System Benefits
- Modular Installation Flexibility: The separate coil and blower design allows each component to be positioned independently, accommodating tight mechanical closets, attics, and crawl spaces where a single-piece air handler may not fit.
- High Seasonal Efficiency: 16.6 SEER2 cooling and 8.5 HSPF2 heating ratings maximize energy savings across both seasons, potentially qualifying for federal tax credits and utility rebates.
- Variable-Speed Comfort: The variable-speed outdoor compressor and communicating ECM blower motor work together to modulate airflow and capacity, delivering consistent temperatures and improved dehumidification at part-load conditions.
- Low-GWP R-32 Refrigerant: R-32 has a 68% lower global warming potential than R-410A and offers higher volumetric cooling capacity, supporting the industry transition under the AIM Act phasedown schedule.
- Communicating Integration: The MBVK blower's ComfortBridge technology communicates directly with the outdoor unit and compatible thermostat, enabling automated airflow configuration, tonnage matching, and diagnostic reporting through the CoolCloud app.
Technical Specifications
| System Performance (AHRI Certificate #215447615) | |
|---|---|
| SEER2 | 16.6 |
| HSPF2 | 8.5 |
| Refrigerant | R-32 |
| Outdoor Unit — GZV6SA3610* | |
| Cooling Capacity (BTU/h) | 34,200 |
| Heating Capacity @47°F (BTU/h) | 34,600 |
| Heating Capacity @17°F (BTU/h) | 20,000 |
| Compressor Type | Variable-Speed Swing |
| Sound Level (Cooling/Heating) | 68 / 71 dBA (as low as 45 dBA in quiet mode) |
| Dimensions (W x D x H) | 36-5/8" x 13-3/4" x 27-3/8" |
| Operating Weight / Ship Weight | 137 lbs / 151 lbs |
| Electrical | 208-230V / 1 Phase / 60 Hz |
| MCA / MOCP | 22.4A / 25A |
| Refrigerant Charge | 83 oz (factory charge for 15' line set) |
| Line Connections (Liquid / Suction) | 3/8" / 7/8" |
| Evaporator Coil — CAPEA3626D3A* | |
| Configuration | Upflow/Downflow (Cased) |
| Cabinet Dimensions (W x D x H) | 24-1/2" x 21" x 26" |
| Expansion Device | EEV (Electronic Expansion Valve) |
| Line Connections (Liquid / Suction) | 5/16" or 3/8" / 3/4" or 7/8" |
| Ship Weight | 62 lbs |
| Modular Blower — MBVK20DP1X00AA | |
| Configuration | Multi-Positional (Vertical / Horizontal) |
| Airflow | Up to 2000 CFM |
| Cabinet Dimensions (W x D x H) | 24-1/2" x 21" x 30" |
| Blower Motor | 3/4 HP Variable-Speed ECM |
| Electrical | 208-230V / 1 Phase / 60 Hz |
| MCA / MOCP | 6.5A / 15A |
| Ship Weight | 86 lbs |
Note: See 'Resources (System Manuals and Warranty)' Tab above for full specifications.
Compliance & Environmental Data
| Category | Details |
|---|---|
| Refrigerant Type | R-32 (Difluoromethane) — A2L (mildly flammable) classification |
| Global Warming Potential (GWP) | 675 (68% lower than R-410A at 2,088) |
| EPA Section 608 Requirements | EPA-certified technician required for refrigerant handling; R-32 requires A2L-rated recovery equipment and leak detection |
| Regional Compliance | All-region sales designation (Region A); verify local A2L refrigerant installation codes and charge density limits per ASHRAE 15 |
| Federal Tax Credit Eligibility | Heat pump systems meeting efficiency thresholds may qualify for federal tax credits under the Inflation Reduction Act (25C) — consult a qualified tax professional for current eligibility requirements |
| Certifications | AHRI Certified; ETL Listed; ENERGY STAR (when matched with qualifying indoor components) |
Warranty & Registration
- Outdoor Heat Pump (GZV6SA3610*): 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. If the compressor fails within the first 10 years in a registered unit, Goodman will furnish a new replacement outdoor unit (one time). Registration not required in California, Florida, or Quebec.
- Evaporator Coil (CAPEA3626D3A*): 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.
- Modular Blower (MBVK20DP1X00AA): 5-Year Initial Term parts warranty. With online registration at goodmanmfg.com within 60 days of installation: 10-Year Registered Additional Term parts warranty. Registration not required in California, Florida, or Quebec.
All warranties apply to owner-occupied residential installations only. Different terms apply to commercial and rental properties. Labor, refrigerant, freight, and other service costs are not covered. Complete warranty details are available at goodmanmfg.com.
Let customers speak for us